1、BRITISH STANDARD BS EN 61300-2-4:1997 IEC 61300-2-4:1995 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-4: Tests Fibre/cable retention The European Standard EN 61300-2-4:1997 has the status of a British Standard ICS 33.180.20 Licensed Copy: sh

2、effieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61300-2-4:1997 This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 Oc

3、tober 1997 BSI 09-1999 ISBN 0 580 28554 5 National foreword This British Standard is the English language version of EN 61300-2-4:1997. It is identical with IEC 61300-2-4:1995. The UK participation in its preparation was entrusted by Technical Committee EPL/86, Fibre optics, to Subcommittee EPL/86/2

4、, Interconnecting devices and passive components, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related inter

5、national and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered

6、as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references Attention is drawn to the fact that CEN and CENELEC Standards normally include an annex which lists normative references to int

7、ernational publications with their corresponding or European publications. The British Standards which implement these international or European publications may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find”

8、facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal ob

9、ligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 4 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on t

10、he inside front cover. Amendments issued since publication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61300-2-4:1997 BSI 09-1999i Contents Page National forewordInside front cover Foreword2 Text of EN 61300-2-

11、43 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ii blank Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61300-2-4 July 1997 I

12、CS 33.180.20 English version Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-4: Tests Fibre/cable retention (IEC 61300-2-4:1995) Dispositifs dinterconnexion et composants passifs fibres optiques Mthodes fondamentales dessais et de mesures Parti

13、e 2-4: Essais Rtention de la fibre ou du cble (CEI 61300-2-4:1995) Lichtwellenleiter Verbindungselemente und passive Bauteile Grundlegende Prf- und Meverfahren Teil 2-4: Prfungen: Zugfestigkeit von Faser oder Kabel (IEC 61300-2-4:1995) This European Standard was approved by CENELEC on 1997-07-01. CE

14、NELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on

15、 application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Sec

16、retariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENEL

17、EC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1997 CENELEC All rights of exploitation in any form and by any means reserved worldwide

18、 for CENELEC members. Ref. No. EN 61300-2-4:1997 E Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 61300-2-4:1997 BSI 09-1999 2 Foreword The text of the International Standard IEC 61300-2-4:1995, prepared by SC 86B, Fibre optic interconne

19、cting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the formal vote and was approved by CENELEC as EN 61300-2-4 on 1997-07-01 without any modification. The following dates were fixed: Endorsement notice The text of the International Standard IEC 61300-2-4:1995 was appr

20、oved by CENELEC as a European Standard without any modification. Contents Page Foreword2 1General3 2Apparatus3 3Procedure3 4Severity4 5Details to be specified4 latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop)

21、 1998-06-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 1998-06-01 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 61300-2-4:1997 BSI 09-19993 1 General 1.1 Scope and object The purpose of

22、 this part of IEC 1300 is to ensure that the captivation or attachment of the fibre/cable to a fibre optic device will withstand tensile loads likely to be applied during normal service. 1.2 General description The specimen is rigidly clamped to a holding fixture and a tensile load is applied to the

23、 fibre/cable. Potential failure modes for this test include, but are not limited to: a) cable jacket damage; b) fibre breakage or damage; c) cable clamp failure; d) cable pull-out; e) loss of optical continuity; f) degradation of optical transmission characteristics; g) excessive movement of the cab

24、le/terminus relative to the device. 2 Apparatus The apparatus consists of the following elements. 2.1 Holding fixture A means to hold the fibre/cable and the device(s) in position for the duration of the test. The holding, method used shall not distort the device under test. Mount the device in a fi

25、xed position using its normal mounting provisions. As an example, wrap the fibre/cable around a mandrel having a diameter which is at least 25 times the diameter of the fibre/cable. Use an adequate number of turns to preclude slippage. The distance between the rearmost portion of the device under te

26、st and the mandrel tangent point shall be no less than 50 times the diameter of the fibre/cable. NOTEThe fixturing should allow the specimen to be connected to an optical source and detector in order to monitor changes in attenuation (if required by the detail specification). 2.2 Force generator An

27、appropriate device or apparatus capable of smoothly applying the specified force at the specified rate. 2.3 Force gauge An appropriate gauge to register the amount of force being exerted between the device under test and the fibre/cable. This equipment may include a device to record the rate of forc

28、e application or the total time the force is applied, or both. 2.4 Alternative apparatus Unless otherwise specified in the detail specification, other apparatus may be used in lieu of a mechanical separation device or force gauge. For example, the required force may be achieved by applying controlle

29、d increments of mass to one of the holding devices while the other holding device remains fixed. 2.5 Timer A device to measure the total time the force is applied, if the apparatus mentioned in 2.3 is not used. 2.6 Other equipment Optical and other examination and measuring equipment shall be availa

30、ble as required by IEC 1300-3-1 and IEC 1300-3-5, as appropriate. Refer to the required procedure for details. 3 Procedure 3.1 Visually examine each specimen in accordance with IEC 1300-3-1 to ensure that the specimens have not been damaged. 3.2 Unless otherwise specified, precondition each prepared

31、 specimen for 4 h at the standard test conditions specified in IEC 1300-1. 3.3 Securely mount the device under test on the holding fixture and place in the test apparatus. 3.4 Perform any initial optical measurement and make any other measurements as required by the detail specification. Unless othe

32、rwise specified in the detail specification, measure the attenuation in accordance with IEC 1300-3-5. 3.5 Activate the test apparatus so that an axial force is gradually exerted between the fibre/cable and the device under test. Apply the load gradually so as to eliminate any impulse or impact loadi

33、ng effect. If automatic equipment is used, it is recommended that the rate of separation of the holding devices be approximately 25 mm/min. Continue loading until the tensile load specified in the detail specification has been reached. 3.6 Maintain the specified load for the specified time period re

34、quired by the detail specification. While the specimen is under load, make observations and perform measurements as required by the detail specification. 3.7 Remove the test load and perform any final optical measurement required by the detail specification. Unless otherwise specified in the detail

35、specification, measure the attenuation in accordance with IEC 1300-3-5. 3.8 Remove the specimen from the test apparatus and visually examine each specimen in accordance with IEC 1300-3-1. Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 61

36、300-2-4:1997 4 BSI 09-1999 4 Severity The severity consists of the magnitude of the tensile load and the time duration it is applied. The severity shall be given in the detail specification. 5 Details to be specified The following details, as applicable, shall be specified in the detail specificatio

37、n: Quantity and description of samples required for test Magnitude, direction, and rate of application of the tensile load Point of application of the tensile load Duration of the load Pre-conditioning procedure Recovery procedure Method of holding Specimen functioning or non-functioning Initial exa

38、minations and measurements and performance requirements Examinations and measurements during test and performance requirements Final examinations and measurements and performance requirements Optical measurement method, if necessary Method of presenting data (for components tested to failure, a Weib

39、ull distribution may be appropriate) Deviations from test procedure Additional pass/fail criteria Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 5blank Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontro

40、lled Copy, (c) BSI BS EN 61300-2-4:1997 IEC 61300-2-4:1995 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is

41、 incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful i

42、f anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: 020 8996 9000. Fax: 020 8996 7400. BSI offers members an individual updating service cal

43、led PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001. In response to orders for internatio

44、nal standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technic

45、al Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: 020 8996 7111. Fax: 020 8996 7048. Subscribing members of BSI are kept up to date with standards developments and rec

46、eive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: 020 8996 7002. Fax: 020 8996 7001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the

47、internationalstandardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI.

48、 This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. If permission is granted, the terms may include royalty payments or a licensing agreement. Details and advice can be obtained from the Copyright Manager. Tel: 020 8996 7070. Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:36:34 GMT+00:00 2006, Uncontrolled Copy, (c) BSI