1、TECHNICAL REPORT IEC 61010-3-020 First edition 1999-04 Safety requirements for electrical equipment for measurement, control, and laboratory use Part 3-020: Conformity verification report for IEC 61010-2-020:1992 Particular requirements for laboratory centrifuges Rgles de scurit pour appareils lectr

2、iques de mesurage, de rgulation et de laboratoire Partie 3-020: Rapport de vrification de la conformit de la CEI 61010-2-020:1992 Prescriptions particulires pour centrifugeuses de laboratoire Reference number IEC 61010-3-020:1999(E) Copyright International Electrotechnical Commission Provided by IHS

3、 under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,-,- Numbering As from 1 January 1997 all IEC publications are issued with a designation in the 60000 series. Consolida

4、ted publications Consolidated versions of some IEC publications including amendments are available. For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2. Va

5、lidity of this publication The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology. Information relating to the date of the reconfirmation of the publication is available in the IEC catalogue. Information on the s

6、ubjects under consideration and work in progress undertaken by the technical committee which has prepared this publication, as well as the list of publications issued, is to be found at the following IEC sources: IEC web site* Catalogue of IEC publications Published yearly with regular updates (On-l

7、ine catalogue)* IEC Bulletin Available both at the IEC web site* and as a printed periodical Terminology, graphical and letter symbols For general terminology, readers are referred to IEC 60050: International Electrotechnical Vocabulary (IEV). For graphical symbols, and letter symbols and signs appr

8、oved by the IEC for general use, readers are referred to publications IEC 60027: Letter symbols to be used in electrical technology, IEC 60417: Graphical symbols for use on equipment. Index, survey and compilation of the single sheets and IEC 60617: Graphical symbols for diagrams. * See web site add

9、ress on title page. Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,-,- TECHNICAL REPORT IEC 61010-

10、3-020 First edition 1999-04 Safety requirements for electrical equipment for measurement, control, and laboratory use Part 3-020: Conformity verification report for IEC 61010-2-020:1992 Particular requirements for laboratory centrifuges Rgles de scurit pour appareils lectriques de mesurage, de rgula

11、tion et de laboratoire Partie 3-020: Rapport de vrification de la conformit de la CEI 61010-2-020:1992 Prescriptions particulires pour centrifugeuses de laboratoire PRICE CODE IEC 1999 Copyright - all rights reserved No part of this publication may be reproduced or utilized in any form or by any mea

12、ns, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission3, rue de Varemb Geneva, Switzerland Telefax: +41 22 919 0300e-mail: inmailiec.ch IEC web site http:/www.iec.ch V For price, see current cata

13、logue Commission Electrotechnique Internationale International Electrotechnical Commission Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networki

14、ng permitted without license from IHS -,-,- 2 61010-3-020 IEC:1999(E) CONTENTS Page FOREWORD .3 Conformity verification report IEC 61010-2-0205 Clause 5Marking and documentation.10 6Protection against electric shock .17 7Protection against mechanical hazards25 8Mechanical resistance to shock, vibrat

15、ion and impact 28 Mechanical resistance to shock and impact (IEC 61010-1 with amendment 2) 9Equipment temperature limits and protection against the spread of fire 28 10Resistance to heat 29 11Resistance to moisture and liquids 30 Protection against hazards from fluids (IEC 61010-1 with amendment 2)

16、12Protection against radiation, including laser sources, and against sonic and ultrasonic pressure .31 13Protection against liberated gases, explosion and implosion and escape of microbiological materials .31 14Components32 15Protection by interlocks .33 16Measuring circuits .33 Annex K Routine test

17、s 33 Tables 1Documents attached to this report .7 2Test equipment list8 3List of components relied on for safety 9 Form A.1 to Form A.37 34 to 70 Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Res

18、ale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,-,- 61010-3-020 IEC:1999(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE Part 3-020: Conformity verification repor

19、t for IEC 61010-2-020:1992, Particular requirements for laboratory centrifuges FOREWORD 1)The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of the IEC is to pro

20、mote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, the IEC publishes International Standards. Their preparation is entrusted to technical committees; any IEC National Committee interest

21、ed in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in accordance w

22、ith conditions determined by agreement between the two organizations. 2)The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interes

23、ted National Committees. 3)The documents produced have the form of recommendations for international use and are published in the form of standards, technical specifications, technical reports or guides and they are accepted by the National Committees in that sense. 4)In order to promote internation

24、al unification, IEC National Committees undertake to apply IEC International Standards transparently to the maximum extent possible in their national and regional standards. Any divergence between the IEC Standard and the corresponding national or regional standard shall be clearly indicated in the

25、latter. 5)The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with one of its standards. 6) Attention is drawn to the possibility that some of the elements of this technical report may be the subject of pate

26、nt rights. The IEC shall not be held responsible for identifying any or all such patent rights. The main task of IEC technical committees is to prepare International Standards. However, a technical committee may propose the publication of a technical report when it has collected data of a different

27、kind from that which is normally published as an International Standard, for example “state of the art“. Technical reports do not necessarily have to be reviewed until the data they provide are considered to be no longer valid or useful. IEC 61010-3-020, which is a technical report, has been prepare

28、d by IEC technical committee 66: Safety of measuring, control and laboratory equipment. The text of this technical report is based on the following documents: Enquiry draftReport on voting 66/187/CDV66/211/RVC Full information on the voting for the approval of this technical report can be found in t

29、he report on voting indicated in the above table. Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,-

30、,- 4 61010-3-020 IEC:1999(E) This report is a Technical Report and is of a purely informative nature and is therefore by itself not to be regarded as an International Standard. It is for use by testhouses and other users to assist them with determining and recording verification of conformity of the

31、 equipment under test with the requirements of: IEC 61010-2-020:1992 + amendment 1:1996 The protocol for completion of this report is contained in publication IEC 61010-3:1997. The IEC sells read-only PDF files as a general rule. In the present instance, and quite exceptionally, to enable the user t

32、o fill in the forms, a revisable file is included in a pocket affixed to the back cover of this publication. This publication can also be downloaded from the Web as a PDF file. There is, however, at the end of the document, a revisable file containing the forms. Please use the zip/unzip function. Co

33、pyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,-,- 61010-3-020 IEC:1999(E) 5 Conformity Verification

34、 Report IEC 61010-2-020 Safety requirements for electrical equipment for measurement, control and laboratory use: Part 2-020: Particular requirements for laboratory centrifuges (including amendment 1:1996) Report reference No : Compiled by (+ signature): Approved by (+ signature): Date of issue: Tes

35、ting organization.: Address: Testing location: Applicant: Address: Standard :IEC 61010-1:1990 + amendment 1:1992 + amendment 2:1995 IEC 61010-2-020:1993 + amendment 1:1996 Copyright blank test report.:This report has been prepared by IEC TC 66, which retains responsibility for any changes or correct

36、ions required. Test procedure.: Procedure deviation.: Non-standard test method .: Type of item tested :Laboratory Trademark: Model/type reference .: Manufacturer: Rating.: Copy of rating plate: Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Emp

37、loyees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,-,- 6 61010-3-020 IEC:1999(E) Description of equipment function: INSTALLATION/OVERVOLTAGE CATEGORY: POLLUTION DEGREE: Environmental rating:? Standard? Other

38、(specify): Equipment mobility:? Portable? Floorstanding? Fixed ? Built in? Benchmounted? Other (specify): Connection to mains supply:? Permanent? Detachable ? Non detachable? None Operating conditions:? Continuous? Short-time? Intermittent Overall size of the equipment (Length Width Height): Mass of

39、 the equipment (kg): Marked degree of protection to IEC 60529: IP_ _ Accessories and detachable parts included in the evaluation: Options: NOTE “(see form A.X)“ refers to a form appended to the report. Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee

40、=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,-,- 61010-3-020 IEC:1999(E) 7 Table 1 Documents attached to this report Document No.Document description Number of pages Copyright International Elec

41、trotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,-,- 8 61010-3-020 IEC:1999(E) Table 2 Test equipment list Equipment Calibration

42、 date ItemType No. Last1)Due Comments 1) or interval between calibrations. Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted wit

43、hout license from IHS -,-,- Table 3 List of components relied on for safety Unique component reference or location (including drawing reference if required) Application/Function Manufacturer and part number (note 1) RATING (note 2) Licence number, file number or other documentary evidence of accepta

44、nce NOTE 1 List all manufacturers concerned. NOTE 2 Electrical, mechanical, flammability, etc. Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or netw

45、orking permitted without license from IHS -,-,- 10 61010-3-020 IEC:1999(E) Result: P = Pass F = Fail NA = Not Applicable Clause Subclause RequirementResultComments 5Marking and documentation 5.1.1General Required equipment markings are: a) visible: from the exterior or after removing a cover or open

46、ing a door or after removal from a rack or panel b) not put on parts which can be removed by an OPERATOR c) letter symbols (IEC 60027) used d) graphic symbols used (IEC 61010-1, Table 1) 5.1.2Identification Equipment is identified by: manufacturers name or registered trade mark unique production bat

47、ch identification 5.1.3Mains supply Equipment is marked as follows: a) nature of supply: a.c. RATED mains frequency or range of frequencies d.c. with symbol 1 b)RATED supply voltage(s) or range c) maximum RATED power (W or VA) or input current If more than one voltage range: separate values marked o

48、r F values differ by less than 20 % (see Form A.3) Copyright International Electrotechnical Commission Provided by IHS under license with IECLicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/08/2007 23:17:48 MSTNo reproduction or networking permitted without license from IHS -,

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1