1、 Reference number ISO 11452-8:2007(E) ISO 2007 INTERNATIONAL STANDARD ISO 11452-8 First edition 2007-07-01 Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 8: Immunity to magnetic fields Vhicules routiers Mthodes dessai dun quipeme

2、nt soumis des perturbations lectriques par rayonnement dnergie lectromagntique en bande troite Partie 8: Mthodes dimmunit aux champs magntiques Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=IHS Employees/1111111001, User=DAWSON, DAVIS Not fo

3、r Resale, 07/03/2007 02:24:43 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 11452-8:2007(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the t

4、ypefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adob

5、e Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unl

6、ikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2007 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electron

7、ic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org

8、Web www.iso.org Published in Switzerland ii ISO 2007 All rights reserved Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=IHS Employees/1111111001, User=DAWSON, DAVIS Not for Resale, 07/03/2007 02:24:43 MDTNo reproduction or networking permitte

9、d without license from IHS -,-,- ISO 11452-8:2007(E) ISO 2007 All rights reserved iii Contents Page Foreword iv 1 Scope . 1 2 Normative references. 1 3 Test conditions . 1 3.1 General. 1 3.2 Frequency step sizes 2 4 Test location 2 5 Test apparatus description and specification . 2 5.1 General. 2 5.

10、2 Field generating device 3 5.3 Current monitor. 4 5.4 Magnetic field intensity monitor 4 5.5 Stimulation and monitoring of the DUT 4 6 Test set-up. 5 6.1 General. 5 6.2 Power supply. 5 6.3 Location of the test harness 5 6.4 Radiating loop method. 5 6.5 Helmholtz coil method 6 7 Test procedure 8 7.1

11、 General. 8 7.2 Test plan 8 7.3 Test method. 9 7.4 Test report . 13 Annex A (informative) Function performance status classification (FPSC) and test severity levels 14 Bibliography. 17 Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=IHS Employ

12、ees/1111111001, User=DAWSON, DAVIS Not for Resale, 07/03/2007 02:24:43 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 11452-8:2007(E) iv ISO 2007 All rights reserved Foreword ISO (the International Organization for Standardization) is a worldwide federation of national

13、 standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. Internationa

14、l organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules

15、given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at lea

16、st 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 11452-8 was prepared by Technical Committee ISO/TC 2

17、2, Road vehicles, Subcommittee SC 3, Electrical and electronic equipment. ISO 11452 consists of the following parts, under the general title Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy: Part 1: General principles and terminology Pa

18、rt 2: Absorber-lined shielded enclosure Part 3: Transverse electromagnetic mode (TEM) cell Part 4: Bulk current injection (BCI) Part 5: Stripline Part 7: Direct radio frequency (RF) power injection Part 8: Immunity to magnetic fields The following parts are under preparation: Part 9: Portable transm

19、itters Part 10: Conducted immunity in the extended audio frequency range Part 11: Radiated immunity test method using a reverberation chamber Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=IHS Employees/1111111001, User=DAWSON, DAVIS Not for

20、Resale, 07/03/2007 02:24:43 MDTNo reproduction or networking permitted without license from IHS -,-,- INTERNATIONAL STANDARD ISO 11452-8:2007(E) ISO 2007 All rights reserved 1 Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy Part 8: Imm

21、unity to magnetic fields 1 Scope This part of ISO 11452 specifies tests for the electromagnetic immunity of electronic components for passenger cars and commercial vehicles, regardless of the propulsion system (e.g. spark-ignition engine, diesel engine, electric motor), to magnetic fields generated

22、by power transmission lines and generating stations and some powerful electrical equipment, such as motors. To perform this test, the device under test (DUT) is exposed to a magnetic disturbance field. The radiating loop method can be applied to small DUTs or to larger DUTs by positioning the coil i

23、n multiple locations. The Helmholtz coil is sometimes used as an alternative method. This technique is limited by the relationship between the size of the DUT and the size of the coils. The electromagnetic disturbances considered in this part of ISO 11452 are limited to continuous narrowband electro

24、magnetic fields. Immunity measurements of complete vehicles can generally only be carried out by the vehicle manufacturer for reasons including the high cost of an absorber-lined shielded enclosure preserving the secrecy of prototypes or the large number of different vehicle models. Consequently, fo

25、r research, development and quality control, a laboratory measuring method is used by the vehicle manufacturer and equipment suppliers to test electronic components. ISO 11452-1 specifies general test conditions, definitions, practical use and basic principles of the test procedure. 2 Normative refe

26、rences The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 11452-1, Road vehicles Component test

27、methods for electrical disturbances from narrowband radiated electromagnetic energy Part 1: General principles and terminology 3 Test conditions 3.1 General The applicable frequency range of this test method is 15 Hz to 150 kHz. Copyright International Organization for Standardization Provided by IH

28、S under license with ISO Licensee=IHS Employees/1111111001, User=DAWSON, DAVIS Not for Resale, 07/03/2007 02:24:43 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 11452-8:2007(E) 2 ISO 2007 All rights reserved The users shall specify the test severity level(s) over the

29、frequency range. Suggested test severity levels are included in Annex A. Standard test conditions are given in ISO 11452-1 for the following: test temperature; supply voltage; dwell time; definition of test severity levels. 3.2 Frequency step sizes The tests shall be conducted at the following frequ

30、encies: 16,67 Hz, 50 Hz, 60 Hz, 150 Hz and 180 Hz and with frequency step sizes (logarithmic or linear) not greater than those specified in Table 1. The step sizes agreed upon by the users of this part of ISO 11452 shall be documented in the test report. Table 1 Maximum frequency steps sizes Frequen

31、cy band kHz Linear steps kHz Logarithmic steps % 0,015 to 0,1 0,01 10 0,1 to 1 0,1 10 1 to 10 1 10 10 to 150 10 10 NOTE The 5th harmonic of 16,67 Hz, 50 Hz and 60 Hz can also be tested. If it appears that the susceptibility thresholds of the DUT are very near to the chosen test level, these frequenc

32、y step sizes should be reduced in the frequency range concerned in order to find the minimum susceptibility thresholds. 4 Test location A shielded room is not required. IMPORTANT The appropriate guidelines (national regulation, ICNIRP3, etc.) shall be followed for the protection of the test personne

33、l. 5 Test apparatus description and specification 5.1 General The test apparatus shall consist of the following: field generating device(s): radiating loop or Helmholtz coil; magnetic field intensity monitor; low frequency (LF) generator; low frequency (LF) amplifier (capable of driving inductive lo

34、ad); Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=IHS Employees/1111111001, User=DAWSON, DAVIS Not for Resale, 07/03/2007 02:24:43 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 11452-8:2007(E) ISO 2007 All ri

35、ghts reserved 3 voltmeter; current monitor; artificial network(s) (AN) (optional, see ISO 11452-4 for characteristics). 5.2 Field generating device 5.2.1 Radiating loop The radiating loop of MIL STD 461E2 is recommended, but any similar coil may be used. The MIL STD 461E coil has the following chara

36、cteristics: diameter: 120 mm number of turns: 20 wire: approx. 2,0 mm (AWG12) The magnetic flux density at a distance of 50 mm from the plane of the loop is given by Equation (1): 5 0 9,5 10BHI = (1) The unperturbed magnetic field at a distance of 50 mm from the plane of the loop is given by Equatio

37、n (2): 75,6HI= (2) The radiating loop should be characterized over the frequency range. Non-linear characteristics shall be considered in determining the calculated current value for the DUT test. 5.2.2 Helmholtz coil Ideally, Helmholtz coils set up a region of uniform magnetic fields. The primary u

38、sage of the coils is to expose the DUT to a uniform magnetic field. The radius of the coils is determined by the size of the DUT. In order to obtain a uniform magnetic field ( 10 %), the relationship between the coils and the DUT should be met, as shown in Figure 3. The uniform field region shown in

39、 Figure 3 should be a minimum of 300 mm 300 mm 300 mm. For a pair of Helmholtz coils spaced one radius apart, the magnetic flux density at the centre of the system is given by Equation (3): 7 0 8,992 10NI BH R = (3) where B is the magnetic flux density, in tesla; N is the number of wire turns on the

40、 coil; R is the coil radius, in metres; I is the coil current, in amperes; H is the magnetic field, in amperes per metre; 0 is the magnetic constant, permeability of the vacuum, in henry per metre. Copyright International Organization for Standardization Provided by IHS under license with ISO Licens

41、ee=IHS Employees/1111111001, User=DAWSON, DAVIS Not for Resale, 07/03/2007 02:24:43 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 11452-8:2007(E) 4 ISO 2007 All rights reserved The unperturbed magnetic field, H, at the centre of the system is given by Equation (4): 0,

42、715 5NI H R = (4) The current-carrying capability and number of turns of the coils should be selected such that the test specification can be met. The coils shall not have a self-resonant frequency at or lower than the upper frequency of 150 kHz. The Helmholtz coil should be characterized over the f

43、requency range. 5.3 Current monitor The current monitor shall ensure that true RMS current measurement is made within the frequency range 15 Hz to 150 kHz, either by using a clamp-on probe or by measuring voltage across a shunt resistor. An oscilloscope, a true RMS a.c. voltmeter or a true RMS a.c.

44、current meter may be used. 5.4 Magnetic field intensity monitor For the radiating loop method, the magnetic field intensity monitor shall be a loop sensor having the following specifications: diameter: 40 mm number of turns: 51 wire: approx. 0,071 mm (7 strand 41 AWG) shielding: electrostatic correc

45、tion factor: see manufacturers data for factor to convert sensor coil voltage to magnetic intensity. The open-circuit voltage, U, measured in volts by means of a high-impedance voltmeter, is induced in the loop sensor and is calculated as shown in Equation (5): 2UfNAB= where f is the frequency, in h

46、ertz; N is the number of wire turns in the coil; A is the cross-sectional area of the coil, in square metres, calculated with the average diameter of the coil; B is the magnetic flux density, in tesla. A typical magnetic field intensity monitor should be capable of measuring a magnetic field intensi

47、ty of at least 1 000 A/m across the frequency range 15 Hz to 150 kHz. 5.5 Stimulation and monitoring of the DUT If required in the test plan, the DUT shall be operated by actuators which have minimum effect on the electromagnetic characteristics, e.g. plastic blocks on the push buttons or pneumatic

48、actuators with plastic tubes. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=IHS Employees/1111111001, User=DAWSON, DAVIS Not for Resale, 07/03/2007 02:24:43 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 11452-8:2007(E) ISO 2007 All rights reserved 5 Connections to equipment monitoring electromagnetic