1、FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION Subject 80 (180, 443) June 14, 2006 SUMMARY OF TOPICS The following changes in requirements are being proposed: 1. For Preliminary Review Only: Addition of the Requirements for Tank Accessories (UL 80 - PR2839), Revision of the Requiremen

2、ts for the Physical Abuse Tests (UL 80 - PR2868), and Revision of the Requirements for the Hydrostatic Pressure Test (UL 80 - PR2869) 2. For Preliminary Review Only: Revision of the Requirements for Tank Top and Bottom Openings (UL 80 - PR2861) 3. For Preliminary Review Only: Revision of the Require

3、ments for Markings and Instructions (UL 80 - PR4458) 4. For Preliminary Review Only: Addition of the Requirements for Double Bottom Tanks (UL 80 - PR4482) 5. For Preliminary Review Only: Revision of the Requirements for Manufacturing and Production Tests (UL 80 - PR4484) COMMENTS DUE: July 29, 2006

4、Please note that because individual proposals may contain interdependent references or content, some individual proposals have been combined into one proposal item in order to facilitate the process. For your convenience in review, proposed additions to existing requirements are shown underlined and

5、 proposed deletions are shown lined-out. 1. For Preliminary Review Only: Addition of the Requirements for Tank Accessories (UL 80 - PR2839), Revision of the Requirements for the Physical Abuse Tests (UL 80 - PR2868), and Revision of the Requirements for the Hydrostatic Pressure Test (UL 80 - PR2869)

6、 Proposal Presented as Submitted by Mr. R. Riegel, Underwriters Laboratories Inc. RATIONALE The proposed revisions for the addition of Section 5B are intended to clarify the UL 80 Tank Accessories that may optionally be provided with the tank, identifi cation of the specifi c requirements these comp

7、onents must comply with, and minimum sizes to match the intended use of the tank. The proposed revisions are intended to add Physical Abuse Tests to UL 80 prior to conducting the hydrostatic pressure test to ensure the tank design type and accessories can meet expected normal and abnormal conditions

8、 of transport, assembly, installation and use. Also documented in this general Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 09:51:48 MDTNo reproduction or networking permitted without license from

9、IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION section are selection of samples, identifi cation of tests, assembly of accessories, tank placement and test fl uids. The hydrostatic test details were deleted (if too restrictive) or moved to another section. 15B Handle Strengt

10、h This proposed test is intended to evaluate handles or lugs provided with the tank at a 2X safety factor. This test simulates normal tank transportation and is similar to requirements of other oil tank standards (UL 142, ULC S603 a) Upon installation pitch tank longitudinally, toward drain, at leas

11、t 1/4 inch per foot of tank length; b) Vent pipe diameter must be at least equal to fi ll pipe diameter. A signaling device installed in vent pipe shall not reduce venting capacity below that of the fi ll pipe capacity; and c) Consult local authorities before installation of tank. 18.4 The additiona

12、l vent opening for venting of the space between the tank walls of each tank of secondary or interstitial construction shall be permanently marked with the following: Secondary vent do not vent indoors or plug. JUNE 14, 2006SUBJECT 80-8- Copyright Underwriters Laboratories Inc. Provided by IHS under

13、license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 09:51:48 MDTNo reproduction or networking permitted without license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION 18.5 The marking required in 18.3 and 18.4 shall be ink-stamped or pai

14、nt-stenciled on the tank, or printed on an adhesive-backed label. Minimum letter height shall be 3/32 inch (2.4 mm) as measured by characters such as b, 1, or H. A contrasting background shall be provided for legibility. 18.6 An adhesive-backed label used for required markings shall comply with the

15、requirements in the Standard for Marking and Labeling Systems, UL 969, rated for the intended surface and for: a) Outdoor use (at a temperature range of -35C to 60C (-31F to 140F), exposure to water, and ultraviolet light, and b) Exposure to No. 2 Fuel Oil. Exception:An adhesive-backed label which c

16、ontains installation information only need not comply with the requirements for exposure to No. 2 Fuel Oil. 18A Engineering Markings 18A.1 All Tanks 18A.1.1 Each tank nameplate shall be marked with the following manufacturer identifi cation and general information as applicable: Note Words within “q

17、uotes” are the required verbatim markings. a) The manufacturers name, trade name, trademark or other descriptive marking which identifi es the company responsible for the product and factory ID code when manufactured at more than one factory. b) The manufacturing date in standard format (day/month/y

18、ear), quarterly format (quarter/year) or a code that does not repeat in less than 20 years or require production record reference. c) The manufacturers web address and phone number to obtain installation, inspection and maintenance instructions for compliance with 20.1. d) The tank series, model, ca

19、talog number, or equivalent identifi cation, and nominal capacity in gallons. e) The tank basic design type “Primary Tank”, “Secondary Tank” or “Diked Tank”, as appropriate. f) The optional construction type “Double Bottom” when in compliance with Section 6. 18A.1.2 Each tank shall be marked with th

20、e following critical assembly, installation, inspection, and cautionary information on or near the nameplate: a) “IMPORTANT - Assemble and Install per NFPA 31 and Manufacturer Instructions” and a “CAUTION” header followed by the following critical points: 1) “This Tank Is Intended for Stationary Use

21、 Only” 2) “Tilt Tank inch/foot (20.8 mm/meter) Towards Bottom Opening” 3) “Do Not Reduce Vent Capacity Below 1 inch (35 mm) Pipe Size” 4) “Inspect Tank Periodically per Instructions” JUNE 14, 2006SUBJECT 80-9- Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Arm

22、y Northwestern Div./7838506130 Not for Resale, 08/29/2006 09:51:48 MDTNo reproduction or networking permitted without license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION 5) “Remove Accumulated Water From Tank Bottom” 6) “Do Not Transfer Oil from Old Tank Into This Ta

23、nk” b) “CONSULT LOCAL AUTHORITY BEFORE INSTALLING TANK” 18A.2 Primary Containment Tanks 18A.2.1 In addition to all Engineering Markings in accordance with 18A.1, Primary Containment Tanks, Secondary Containment Tanks, or Double Bottom Tanks shall be marked with additional information as appropriate

24、on the nameplate or other location as specifi ed. a) In order to reduce the risk of damage to the tank while conducting leak testing of the tank or piping, “Do Not Exceed 5 psig (34.5 kPa) Test Pressure” unless a specifi c construction has additional damage potential at lower pressures in accordance

25、 with 18A.2.1 (b). b) Constructions where permanent deformation (such as a rectangular) or risk of injury to persons (such as fl at bottom) may occur while leak testing, “Do Not Exceed * psig Test Pressure” (where * = the manufacturer maximum test pressure, but not less than 1.5 psig 10 kPa). 18A.3

26、Secondary Containment Tanks and Double Bottom Tanks 18A.3.1 In addition to all Engineering Markings in accordance with 18A.1 and 18A.2, Secondary Containment and Double Bottom Tanks shall also be marked with additional information as appropriate on the nameplate or other location as specifi ed. a) I

27、dentifi cation of an interstitial space opening that requires venting by “Interstitial Vent” located near the opening. b) Identifi cation of an interstitial space opening that is intended for monitoring by “Interstitial Monitor” or Monitoring Opening located near the opening. 18A.4 Diked Tanks 18A.4

28、.1 In addition to all Engineering Markings in accordance with 18A.1 and 18A.2, Diked Tanks shall also be marked with additional information as appropriate on the nameplate or other location as specifi ed. a) The dike capacity “_ gal Dike Cap” or percent of primary “_ % Dike Cap” located on the namep

29、late next to basic tank type. b) For closed top dikes with venting covers, the statement “Venting Cover - Do Not Obstruct” located on the vent cover. JUNE 14, 2006SUBJECT 80-10- Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 N

30、ot for Resale, 08/29/2006 09:51:48 MDTNo reproduction or networking permitted without license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION 18A.5 Tank Accessories 18A.5.1 In addition to all Engineering Markings in accordance with 18A.1, tanks provided with optional acc

31、essories in accordance with Section 5 shall also be marked with additional information as appropriate on the nameplate or other location as specifi ed. a) Identifi cation of spill container compliant with 5.1 (a) “With Spill Container” located on the nameplate next to basic tank type. b) Identifi ca

32、tion of tank support compliant with 5.1(b) - “With Support” located on the nameplate next to basic tank type 19 Marking Methods 19.1 The required markings shall be on a metal tag in accordance with 19.2 or adhesive labels in accordance with 19.3 affixed to the tank. The markings shall be at least 3/

33、32 inch (2.4 mm) high letters of a color contrasting to the background. The general information nameplate shall be a limited area of the tank shell, separate corrosion resistant metal plate attached to the tank by welding or brazing, or corrosion resistant metal bracket or holder welded or brazed to

34、 the tank. 19.2 Metal tags shall be corrosion resistant metal at least 0.025 in (0.64 mm) thick provided with embossed, etched, stamped, engraved, punched, or equivalent marking method that penetrates the tag surface. The tag shall be fi xed to the tank or plate by welding or brazing, or secured to

35、a bracket or holder by rivets or tamper resistant screws. Ink stamping or paint stenciling shall be evaluated in accordance with 19.3. 19.3 Adhesive label systems or decal transfers shall comply with the Standard for Marking and Labeling Systems, UL 969; rated for outdoor use (exposure to water, UV

36、light and minimum temperature range of 29C to 60C 20F to 140F) and occasional exposure to oils; and suitable for the intended surface (base metal or paint type). 20 Instructions 20.1 Each tank shall be supplied with instructions in accordance with 20.2 - 20.5 intended to provide proper procedures fo

37、r assembly, installation, and use of the tank. These instructions shall be preceded by the statement “IMPORTANT INFORMATION FOLLOW ALL INSTRUCTIONS” in bold text minimum 1/2 in (12.7 mm) high with at least the following information in text minimum 1/8 in (3.2 mm) high, using any or all of the follow

38、ing methods: a) Shipped with the tank in a protective packing cover b) Shipped with the tank in a protected opening, c) Shipped on the tank as an adhesive label, or d) Available at the manufacturers website. JUNE 14, 2006SUBJECT 80-11- Copyright Underwriters Laboratories Inc. Provided by IHS under l

39、icense with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 09:51:48 MDTNo reproduction or networking permitted without license from IHS -,-,- FOR INTERNAL UL OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION 20.2 Tank manufacturer identifi cation information shall include genera

40、l tank information in 18A.1, and specifi c tank information identical to those applicable in 18A.2 to 18A.5, in addition to basic contact information (company name, address, phone, fax and web) for the tank manufacturer or manufacturers authorized representative. 20.3 General information shall inclu

41、de, but is not limited to, assembly, installation, and use with details for site selection, site preparation, tank handling, support assembly, signal devices, level gauges, fi ll connections, vent connections, supply connections, plus periodic inspection and maintenance recommendations. 20.4 Specifi

42、 c information shall include, but is not limited to, recommended leak test procedures for each tank design with details for conducting the leak test, use of safety devices and cautionary or safety information for expected problems associated with pressure testing, and what to do if leaks are detecte

43、d. 20.5 Recommended Installation Practices The instructions shall also reference recommended installation Codes, such as the Standard for Installation of Oil Burning Equipment, NFPA 31, and recommended inspection and maintenance practices such as NORAs Heating Oil Storage Tank Guide for Inspection a

44、nd maintenance, or other industry equivalents. 4. For Preliminary Review Only: Addition of the Requirements for Double Bottom Tanks (UL 80 - PR4482) Proposal Presented as Submitted by STP 80 Working Group 1 - Double Bottom Tanks RATIONALE This concept was accepted at the last STP 80 meeting. However

45、, additional details were needed and therefore Working Group 1 was formed to address them. One concept that was discussed in detail in the working group was how much area the second bottom should contain on the bottom of the tank. Granby Steel Tanks conducted an autopsy study that showed that 88% of

46、 the leaks on an obround tank occurred on the bottom of the tank within two inches of the centerline. An additional 7% of leaks would be contained if the lower two inches of the head are also double contained. Therefore the working group determined that double containment of the head should be optio

47、nal, as the greatest additional level of safety is obtained simply by double containing the very bottom of the tank. Project Managers Note:To facilitate review, proposals requested under this topic (PR4482) to revise Sections 11 and 12 of the Standard have been merged into Topic 2 of this proposal.

48、Proposals requested under this topic (PR4482) to revise Section 16 of the Standard have been merged into proposed Section 16A in Topic 1 of this proposal. Finally, proposals requested under this topic (PR4482) to revise Section 18 of the Standard have been merged into proposed Section 18A in Topic 3

49、 of this proposal. PROPOSAL 1.1.2 Each tank shall be permitted to be fabricated as a double bottom tank as covered in this Standard. 3.1.8.1 DOUBLE BOTTOM TANK A primary tank with an additional bottom capable of being pressurized and has means for monitoring for leaks in the interstitial space. 6.13 The additional bottom of double bottom