1、2016 learning implement to tube main leaders topic seminar spirit counselling material 2016 learning implement to tube main leaders topic seminar spirit counselling material March 7, XI General Secretary to I province delegation participate in considered and published has important speech, on XXX pr

2、ovince people for China revolution victory and Socialist construction made of contribution give has certainly, on I province past five years implementation focus strategy, and grasp focus industry, economic social development made of results give has certainly, Clarified the demands for development

3、of XXX, referring to both directions, tasks and issues, teaching methods, for the current and future development in Heilongjiang province, is of great practical significance and far-reaching historical significance. March 22 to 24th, provincial held has province tube main leaders topic seminar, prov

4、incial Secretary Wang Xiankui comrade in seminar opening province do has important speech, Wang Xiankui stressed: in-depth learning acquisition General Secretary of speech, is on XXX a political account, we must put learning implement XI General Secretary important speech spirit as major political t

5、ask, adapted and led economic development new normal, insisted to economic construction for Center not shake, implement implementation new development concept, weaknesses, and swagger grams short, and yangchangbuduan, Stimulate the endogenous dynamics, formation effect of EMU, firm implementation of

6、 the five planning, the development of key industries, open Dragon River comprehensive revitalization new journey, struggling to get out of a high quality, efficient, better structure and development road of revitalization of the advantages into full play. March 29 to 30th, the Committee organized a

7、 pipe major thematic seminar of leading cadres prefectural comrade Jia Yumei made an important speech at the opening ceremony. Jia Shuji stressed, full district upper and lower must to effective enhanced learning publicity implement implementation XI General Secretary important speech spirit of poli

8、tical consciously, and thought consciously, and action consciously and mission consciously, put learning XI General Secretary and provincial Secretary Wang Xiankui speech spirit as current primary political task, to more strongly of attitude, and more powerful of measures, and more full of drive pro

9、moted forest transformation development, struggled to out of forest transformation development new, ensure as scheduled achieved full built forest society of target. Today the County for convening this Conference, is to fully implement the arrangements of the provincial, prefectural, and is a major

10、political task. County-wide each of the party members and cadres must earnestly study, deeply understand, enter into the heart, done outside the heart, of the line armed with Jia, Secretary of spirit and mind, practice, work, below, I XX practical study Jia Shujis important speech spirit with you. A

11、wareness, deepen the County, General Secretary重庆电力建设总公司重庆铝业环保搬迁大板锭项目动力车间工程 汽机间A排及山墙施工方案汽机间A排及山墙施工方案一、编制依据混凝土结构工程施工质量验收规范(GB502042002)建筑地基基础工程施工质量验收规范(GB50202-2002)建筑工程施工质量验收统一标准(GB50300-2001)建筑施工扣件式钢管脚手架安全技术规范(JGJ130-2001)电力建设施工质量验收及评定标准(DL/T5210.1-2005)电力建设安全操作规程(DL5009.1-2002)钢筋焊接及验收规范(JGJ18-2003)

12、钢筋机械连接通用技术规程(JGJ107-2010)建筑施工手册(第四版)安全质量环境管理程序文件(E版)施工组织总设计 汽机房施工图 二、工程概况及主要工程量1#机组汽机间A排采用钢筋混凝土排架结构,北侧设有山墙,屋盖采用钢结构。汽机间0.000m相当于绝对高程290.3m,结构高度为35.0m,纵向总共8条轴线(其中1轴至6轴轴线距离12m,6轴至8轴轴线距离9m),总长78m,AB排轴线间距为24m。平面布置简图如下:材料的垂直运输采用布置在固定端及A排外的塔吊完成,并统一堆放在卸料平台(卸料平台布置见脚手架平面图),平面布置图如上。根据施工图,主要实物工程量如下:混凝土550m模板制安3

13、300钢筋制安160t预埋件制安 14t脚手架搭设40000对拉螺杆20t三、施工进度计划主厂房回填至-1.0m且经检测合格后方可进行施工,总工期控制在60个工作日。具体施工工期控制如下:施工段-1m6.52m6.52m 12.55m12.55m 18.35m18.35m 24.08m24.08m 29.02m29.02m 33.20m33.20m 35.0m工期 控制11.0111.0811.0911.1611.1711.2411.2512.0112.0212.0912.1012.1712.1812.25四、施工准备及用材配置4.1施工用水:施工用取水点设在主厂房固定端,上部结构施工时,用直

14、径40毫米的胶管从1轴线处垂直连接到各层楼面,以方便施工时用直径25毫米的橡胶管直接向施工点供水。4.2施工用电:利用现场已有的临时配电设施,在固定端、A排外塔吊基础顶设置两个级配电箱,每层施工时,在A排2轴至3轴线处平台设置一个配电箱,施工用电线路布置负荷按:交流电焊机2台18千瓦、插入式振动器3台1.1千瓦、镝灯4盏3.5千瓦、木工圆盘踞(小型)2台2千瓦计算。混凝土施工设2个移动式电源盘。施工线路按夜间施工时最大负荷:镝灯4盏3.5千瓦+草镝灯(共20千瓦)+交流电焊机2台18千瓦70千瓦考虑。4.3材料条件及准备4.3.1施工正式图到场后7天内提出施工结构1-3层主要材料计划并交材料科

15、备料。4.3.2进场的钢材、焊材、水泥、河砂、碎石等到材料必须附出厂合格证书,现场抽检合格后方能使用。4.3.3钢管脚手架、覆膜板、竹踩板、跳板、密目网、安全网等到周转材料进场根据施工计划及时进场,并统一整齐堆放于规划区域内。根据施工现场实际情况,主要施工机具需用如下表:主要施工机械统计表序号名 称数 量序号名 称数 量1钢筋弯曲机2台6钢筋切断机2台2钢筋套丝机1台7振动器6台3混凝土搅拌站1套8砼罐车4台4砼泵车2台9塔吊2台5钢筋调直机1台五、人员配置根据施工现场实际情况,人员配置如下表:主要人员配置统计表序号职 务人数序号职 务人数1行 管19浇筑工102技 术110木 工153质 量

16、111架子工154安 全112焊 工35人 事113电 工16材 料114值 勤47库 工115后 勤48钢筋工2016普 工10六、施工方法6.1施工段的划分上部结构按楼层划分施工段,共7个施工段:6.250m、12.550m、18.350m、24.080m、29.200m、33.200m、35.000m层。固定端山墙随A排一起施工。在每层脚手架拆除后,做好上部隔离措施后开始施工。 6.2施工顺序山墙及A排回填 放脚手架控制线 脚手架搭设 柱子钢筋绑扎、埋件安装,梁底模安装 柱子钢筋、埋件验收 柱子模板安装 梁钢筋绑扎、埋件安装 梁侧模安装 板模板铺设、埋件安装 板钢筋绑扎 板顶埋件安装 验

17、收 混凝土浇筑 下一个施工段施工。6.3模板工程梁板柱采用1220mm2440mm15mm光面覆模板。按设计尺寸,先对模板放样,然后在木工加工房分批制作配置好,再运至施工作业点使用。对于悬挑长度L2m的梁,支模时梁起拱高度为梁跨度的2,跨度4m的板支模时跨中起拱0.25L0(跨度)。6.3.1梁、板模板梁板结构划分:轴线 施工段6.25m12.55m18.35m24.08m29.20m33.20m35.00m1轴-1轴300*1000 双梁+100板300*1000 双梁+100板300*1000 双梁 300*1000 双梁 300*1000 双梁 300*900 单梁300*700 单梁2

18、轴-3轴300*1000 双梁+100板300*1000 双梁+100板300*1000 双梁300*1000 双梁300*1000 双梁300*900 单梁300*700 单梁3轴-4轴300*1000 双梁+100板300*1000 双梁+100板300*1000 双梁300*1000 双梁300*1000 双梁300*900 单梁300*700 单梁4轴-5轴HW700*300300*1000 双梁+100板300*1000 双梁300*1000 双梁300*1000 双梁300*900 单梁300*700 单梁5轴-6轴300*1000 双梁+100板300*1000 双梁+100板3

19、00*1000 双梁300*1000 双梁300*1000 双梁300*900 单梁300*700 单梁6轴-7轴300*800 双梁+100板300*800 双梁+100板300*800 双梁300*800 双梁300*900 双梁300*800 单梁300*700 单梁7轴-8轴300*800 双梁+100板(8.5m层)300*800 双梁+100板300*800 双梁300*800 双梁300*900 双梁300*800 单梁300*700 单梁 梁、板支撑系统:梁、板的施工方法:梁底用5050木枋固定模板中间及两边,木枋铺设间1根483脚手架管,底部小横杆间距300mm,并在底部设置

20、硬支撑;侧模加固用5050用木枋固定模板中间及两边,木枋之间铺设间距200mm的架管,竖向设置间距300mm架管,侧模中间设置一道M12对拉螺杆,螺杆水平间距600。为消除拆模后对拉螺杆留下的钢筋眼不美观及易生锈的缺陷,每根螺杆均套一根16mm的PVC管,并伸出模板面50mm,以方便将对拉螺杆抽出,对个别不能抽出的,将周围混凝土打成一个小孔,切割进梁内,然后用高标号砂浆补上,用0#特细纱纸将表面打磨平整,并尽量减少色差。梁板模板图如下:(1)对拉螺杆验算混凝土侧压力标准值:F1 =0.22ct012V1/2=0.2224 3.01.21.1531/2=37.86kN/m2F2=cH=241=2

21、4kN/m2;取两者中小值,即F2=24kN/m2。混凝土侧压力设计值:F=241.20.9=25.92kN/m2倾倒混凝土产生的水平荷载:取2 kN/m2,设计值为21.40.9=2.52 kN/m2;则荷载组合为F=25.92+2.52=28.44kN/m2M12拉杆A=762 单根螺杆拉力:N= F0.50.6=8.53 kN单根螺杆应力:=N/A=8.53103/76=112.23205N/2(满足要求)梁侧架管验算:q=0.2*28.44=5.69kN/m,按四跨连续梁计算梁侧架管计算简图弯矩:Mmax=0.107ql2=0.1075.691.21.2=0.88kNm=Mmax/W=

22、0.88*106/(4.49*103)=195.25205N/mm2(满足要求)挠度:挠度计算时计算活荷载及荷载分项系数,梁荷载折算至小横杆上的线荷载为Wmax = 0.634ql4/(100EI)=0.6345.6912003/(100206000107800) =2.33mmw=1/300=1200/300= 4mm(满足要求)(3)梁底小横杆验算序号荷载名称计算式值(kN/m)模板自重标准值0.5(0.3+2+0.05)1.18混凝土自重标准值24(0.31+0.5*0.1)8.4钢筋自重标准值1.5(0.31+0.5*0.1)0.53施工人员及设备荷载1.00.30.3振捣混凝土荷载2

23、.00.30.6则组合荷载为:q=1.2(+)+1.4(+)=1.2(1.18+8.4+0.53)+1.4(0.3+0.6)=13.39kN/m 小横杆间距300mm,立杆横距按650mm计算,小横杆计算简图如下: 梁底小横杆计算简图弯矩:Mmax=0.107ql2=0.10713.390.650.65=0.61kNm=Mmax/W=0.61*106/(4.49*103)=135.8205N/mm2(满足要求)挠度:挠度计算时计算活荷载及荷载分项系数,梁荷载折算至小横杆上的线荷载为q=(+)0.30/0.3=10.11 kN/m= 10.11kN/mWmax = 0.634ql4/(100EI

24、)=0.63410.116503/(100206000107800) =0.52mmw=1/300=650/300= 2.16mm(满足要求)(4)梁底大横杆验算梁两侧大横杆受中间小横杆传递的荷载,验算中间大横杆即可,可以简化为承受均布荷载的三跨连续梁计算,计算简图如下: 梁底大横杆计算简图q=0.513.390.3=2.01kN弯矩:Mmax=0.1ql2=0.12.011.22=0.29kNm= Mmax/W=0.29*106/(4.49*103)=64.46N/mm2fm=205 N/mm2 满足要求挠度:Wmax=0.677ql4/100EI=0.6772.0112004/(10020

25、6000107800) =1.27mm与小横杆计算的跨中最大挠度进行叠加Wmax=1.27+0.52=1.78mml/250=1200/250=2.8mm; 满足要求(5)立杆验算立杆横距300,立杆纵650,立杆节点均采用双扣件8kN,N =13.390.30.5=2.01 kN 8kN 立杆的稳定性:=N/A= 2010/424 =4.73N/mmjf=0.355205=72.77N/mm 满足要求所以梁支模系统承载能力能满足要求(亦可反推求得横杆最大承载能力20.36kN/m组合荷载13.39 kN/m)。6.3.2柱模板短柱已完成一次浇筑,柱顶标高为-0.6m,现取-0. 6m6.25

26、m层,截面尺寸为1600mm*700mm的柱子为例进行计算,柱子净高为5.85m。柱箍采用M16对拉螺杆沿柱高度400mm、柱截面长边400mm、柱截面短边350mm布置。每层柱施工时,其顶面用4根直径14的钢筋内撑撑住模板上口,用于保证柱上口截面准确,便于第二层施工时,柱接头先打毛以保证上下柱的混凝土良好连接,支模时模板与柱脚接触处用双面胶带粘牢,紧密结合不漏缝隙。柱模板加固示意图结构稳定性验算:(1)混凝土侧压力混凝土侧压力标准值:F1 =0.22ct012V1/2=0.2224 3.01.21.1531/2=37.86kN/m2F2=cH=245.85=140.4kN/m2;取两者中小值

27、,即F2=37.86kN/m2。混凝土侧压力设计值:F=37.861.20.9=40.89 kN/m2(2)倾倒混凝土产生的水平荷载根据实际施工情况取2 kN/m2设计值为21.40.9=2.52 kN/m2(3)荷载组合为F=40.89+2.52=43.41 kN/m2(4)对拉螺杆验算M16拉杆A=1442 单根螺杆拉力:N= F0.40.4=6.95 kN单根螺杆应力=N/A=6.95103/144=48.32205N/2(满足要求)(5)长边架管验算柱长边计算简图q= F0.4=43.310.4=17.32 kN/m弯矩验算Mmax=0.10717.320.42=0.297 kNm=M

28、max/W=0.297106/(4.49103)=66.04205N/mm2(满足要求)挠度验算=0.632ql4/100EI=0.63217.324004/(1002.0610510.78104)=0.126400/500=0.8mm(满足要求)(6)短边验算柱短边计算简图Mmax=0.12517.320.352=0.265kNm=Mmax/W=0.265106/(4.49103)=59.06205N/mm2(满足要求)=0.521ql4/100EI=0.52117.323504/(1002.0610510.78104)=0.061350/500=0.7mm(满足要求)6.4钢筋工程6.4.

29、1 钢筋制作 (1) 钢筋加工时,用料单核对钢筋规格,无误后方可进行加工制作。钢筋有严重老锈或其他严重外观问题的不得使用。钢筋进场时的炉号铁牌由专人收集保管,并注明此炉号钢筋用于何构件。钢筋分类按品种、规格、数量、构件名称用小铁丝串树脂布绑在醒目处,以便调用和检查。(2)钢筋弯曲前,对形状复杂的钢筋(如弯起钢筋),根据钢筋料单上标明的尺寸,用石笔将各弯曲点位置划出。划线时应注意:根据不同的弯曲角度扣除弯曲调整值,见下表。其扣法是从相邻两段长度中各扣一半。钢筋弯曲角度3004506009001350钢筋弯曲调整值0.35d0.5d0.85d2d2.5d(3)钢筋施工严格按照设计和规范要求进行施工

30、,钢筋接长采用机械连接。接头需通知监理见证取样,制作好的钢筋须经在试样试拉合格后方可运到现场绑扎。6.4.1 钢筋安装(1)绑扎时达到横平竖直效果,铅丝弯头一律弯向钢筋笼内侧,并均匀悬挂完整的保护层塑料垫块。 (2)墙体插筋在混凝土浇筑完成后,采取植筋方式施工。(3)钢筋绑扎完毕经技术员,技术主管,监理验收后方可进行模板的最后封闭及混凝土浇筑。6.5预埋件工程6.5.1确保预埋件安装的尺寸准确和安装牢固可靠。所有预埋件集中在钳工房制作,所有预埋件均根据设计图纸及标准图集下料、焊接,外形尺寸及焊接强度达到设计要求,预埋件制作完成后,及时标注其型号、规格并分类堆放。预埋件加工时四角钻6孔、安装时用

31、M5螺栓固定在模板上,固定时预埋件边缘要贴双面胶带,保证埋件紧贴模板。6.5.2埋件须采用自动切割机下料,埋件锚筋焊接时尽可能减少变形,可隔点焊且烧焊速度不要过快、避免温度应力过大、过快。对焊接中无法避免造成的变形,在出厂前要加以校正,确保埋件表面平整。6.5.3为保证所有预埋件平面位置与设计图纸相符,做到横平竖直,施工现场先用测量仪器定位轴线,然后用经校验的钢卷尺放样定位。并对所有预埋件在浇筑砼前进行重新复核埋件的数量、规格、位置,做到准确无误后方可浇砼。为保证预埋件与混凝土面的平整,位置准确,符合优质工程目标,并且保证浇筑砼的冲击力不致使埋件脱落。对于侧壁埋件,在安装模板前,先根据设计要求

32、的位置、标高,安装调整好的钢筋上预先把埋件放置好,并根据实际情况,调整埋件的锚脚或与锚脚相碰的钢筋,使埋件的位置准确。埋件表面四周贴双面胶带,与模板面紧贴,防止混凝土浆污梁埋件面。对于面层大埋件,为使混凝土浇灌密实,应在预埋件中间适当开设排气孔。双面胶M5螺栓木模板46孔6.6混凝土工程整个混凝土工程采用搅拌站拌制混凝土、罐车运输、泵车入仓的方法施工,混凝土配置时添加2%的泵送剂。为保证工期,还应添加2%的膨胀剂和2%的早强剂。6.6.1注意事项:1) 浇筑前须用与混凝土同标号砂浆作结合层,厚度50mm。2) 混凝土振捣要密实,注意快插慢拔,振捣上层混凝土时应插入下层混凝土5cm,振捣时间控制

33、在20s30s之间,振动棒不能碰撞钢筋、模板及预埋件。3) 混凝土初凝前应浇筑上一层混凝土。4) 每段浇筑时都浇到模板并与模板上口平齐,表面处理水平,以便施工缝打麻面和冲洗好操作,容易保证施工缝的质量。6.6.2混凝土养护当气温低于10度时只能覆盖浇水湿润, 以保持混凝土表面湿润为准且养护时间不少于7天,该项工作派专人负责。6.6.3施工缝留置及处理根据分段情况,在段与段之间流设水平施工缝。施工缝按规范要求处理,混凝土浇筑后,待达到一定强度后,至少隔24小时再安排石匠对施工缝进行全面打麻面,然后将渣滓全部清理出去,用清水冲洗干净,浇筑时用高标号砂浆接缝。6.6.4砼的成品保护在砼浇筑时,要加强

34、对成品砼的保护,避免造成砼面的二次污染。砼表面在浇筑时造成的污染要及时冲洗、清理干净,先浇筑的部位提前用塑料薄膜包裹严密。浇筑时,浇筑面以上的钢筋、插筋也需用塑料薄膜包裹,防止被污染。6.7脚手架工程脚手架工程采用钢管扣件式脚手架系统,且根据模板体系搭设,材料统一采用48*3型号架管。此次脚手架搭设为5排架,脚手架长度为120m,高度为37.5m;立杆横距依次为1.5m、1.25m、1.25、1.5m,立杆纵距为1.2m,立杆步距1.7m。脚手架系统最终形成一个标准出入通道口、内外双走道、四个吊物平台。通道口位于A轴至1/A轴间;内外侧通道宽度为1500mm,采用1500mm*2000mm竹踩

35、板,竹踩板要用12#铅丝固定在走道上纵向水平杆上。通道外围设置栏杆和挡脚板,栏杆高度为1.2m,挡脚板高度150mm;吊物平台分别2/A至3/A轴、2轴至3轴、4轴至5轴、6轴至7轴间。内外排脚手架内侧挂安全密目网,剪力撑用红白相间警戒色的钢管。6.7.1脚手架搭设顺序脚手架搭设工艺流程为:场地平整、夯实基础承载实验、材料配备定位设置通长脚手板 纵向扫地杆 立杆 横向扫地杆 小横杆 大横杆(搁栅) 剪刀撑 连墙杆 铺竹踩板 扎防护栏杆 扎水平安全网 扎密目网6.7.2脚手架搭设要求 a) 在搭设之前,必须对进场的脚手架杆及配件进行严格的检查,禁止使用规格和质量不合格的架管。b) 严格按照施工设

36、计放线进行铺设垫板,垫板采用50mm厚跳板。搭设时从一个角开始并向两边延伸交圈搭设,应按照定位依次竖立杆,竖立杆时要临时固定,将立杆与纵、横向扫地杆连接固定,扣件扭力矩控制在40-60N.m。然后再搭设第二步纵、横向水平杆,并校正立杆垂直之后予以固定,并按此要求继续向上进行搭设。脚手架搭设接头错缝示意图c) 底部200处加设纵向扫地杆,横向扫地杆在纵向扫地杆的下面,且纵向扫地杆在立杆里侧,其长度不小于3跨。扫地杆必须与立杆连接牢固,扣件扭力矩控制在40-60N.m。d) 钢管脚手架的立杆和水平杆采用对接扣件连接,对接扣件应交错布置,两根相邻纵向水平杆的接头不宜设置在同步或同跨内;不同步或不同跨

37、两个相邻接头在水平方向错开的距离不应小于500mm;各接头中心至最近主节点的距离不宜大于纵距的1/3。e) 剪刀撑的设置:在高度方向每隔6m设置一道水平剪刀撑。剪刀撑斜杆与地面成45 60。的角度,由底到顶连续设置,剪刀撑的连接采用搭接,搭接长度不小于1000,三扎接点长度不小于800。剪刀撑斜杆与横杆、立杆交叉处均连接点不得少于3个。6.7.3走道架计算走道为内外双走道,现取正里面外脚手架(双排)进行计算,(脚手架步距为1.7m,立杆纵距为1.5m,立杆横距为1.2m,内立杆距柱边边450mm)a 荷载计算a)横载的标准值Gk查表得:gk1=0.1225kN/m ,gk2=0.4112 kN

38、/m ,gk3=0.0768 kN/m脚手架高度按38m(实际搭设高度37.5m)计算,则取H=38m,Gk=38(0.1225+0.0768)+1.50.4112=8.190kN取H=19m,Gk=19(0.1225+0.0768)+1.50.4112=4.404kNb)活载的标准值QkQk=1.01.51.8=2.7 kN(查表施工手册得:=1.8kN/m)c)水平风荷载标准值:Wk=0.7UzUsW0根据建筑结构荷载规范(GBJ9)的规定,主厂房位于B类地区,风荷载高度变化系数: Uz=1.0(离地面5m);Uz=1.25(离地面20m)。脚手架状况封闭,风荷载体型系数:Us =1.0=

39、1.01.0=1重庆地区的基本风压:W0=0.4 kN/m2底部截面处:Wk=0.7UzUsW0=0.71.010.4=0.28 kN/m2=1.51.00.28=0.42kN/m19m截面处:Wk =0.71.01.250.40=0.34kN/m2=1.51.00.34=0.51kN/mb 脚手架整体稳定性验算 轴心力设计值N底部截面处: N=1.2(Gk+Qk)=1.2(8.190+2.7)=13.07kN19m截面处: N=1.2(Gk+Qk)=1.2(4.404+2.7)=8.52kN计算风荷载弯矩取跨度为h(步距)的三跨梁的最大支座弯矩:=1.2=1.20.1h2=0.12h2底部截

40、面处:=0.120.421.72=0.146kNm19m截面处:=0.120.511.72=0.177kNm材料强度附加分项系数底部截面处:=0.1h2=0.10.421.72=0.121 kNm= 0.121103424/4490=11.43 kN=2.7/8.190=0.33=11.43/8.190=1.40=1.59(1+0.9(0.33+1.40)/(1+0.33+1.40)=1.49 19m截面处:=0.1h2=0.10.511.72=0.147 kNm= 0.147103424/4490=13.88 kN=2.7/4.404=0.61=13.88/4.404=3.15=1.59(1

41、+0.9(0.61+3.15)/(1+0.61+3.15)=1.46确定稳定系数连墙点即与A排短柱相连1700,采用内插法得:=1.53,=h/i=1.531.7/0.01594=163.1,查表得=0.265验算稳定底部截面处:N/(A)+ Mw/W=13.07/(0.265424)+146/4490=0.148fc/(0.9rm)=0.205/(0.91.49)=0.153 (符合要求)19m截面处: N/(A)+ Mw/W=8.52/(0.265424)+177/4490=0.115fc/(0.9rm)=0.205/(0.91.47)=0.155 (符合要求)综上所述,可知脚手架地面处截

42、面,及一半的高度19m处截面,均符合要求。6.7.4吊物平台脚手架搭设及整体承载性能计算吊物平台1500mm12000mm,下设支撑1200mm,假设平台承受最大均布荷载为q,=m/l=0.6/0.9=0.67,Rav=q0.60.6(1-0.672)=0.20q Rb=0.5q0.9(1+0.67)2(0.92+1.72)0.5/1.7=1.42q Rah=q 0.9(1+0.67)2/(21.7)=0.74q扣件验算:1.42q4kN,有q2.81kN/m;应力验算:Mmax=0.125q0.92(1-0.672)2=0.03q=Mmax/W=0.03q/(4.49103)205N/mm2

43、,有q1.51kN/m;挠度验算:=q6009003(40.672+30.673-1)/(242.0610510.78104) =1.3910-3q 900/500=1.8mm,有q1.29kN/m;综上所诉,吊物平台最大均布荷载为1.29kN/m,即最大承重量为1.291.512=23.22kN。七、质量保证措施牢固树立“质量第一、用户之上”,切实贯彻执行“质量重于泰山”和“质量终身负责制”的质量管理方针。质量管理组织机构如下:项目经理项目副经理项目总工程师调试室物货供应部质量部工程质检员工程材料员工程队长工程队技术负责人木工班钢筋班钳工班浇筑班综合班7.1施工现场所有材料应严格定置管理分类

44、堆码整齐,并做好品种、规格、数量和使用状态标识。7.2施工过程中应做好施工隐蔽工程验收记录、材质跟踪记录、施工验收记录、班组自检记录、施工交底记录等施工技术资料。技术负责人负责施工现场的所有技术资料的收集、汇总、整理和检查工作。7.3所有施工用材料进场时必须具有出厂质量证明书并经试验室取样复试合格,方可用于工程施工中。7.4施工前必须组织相关施工人员进行施工方案及安全技术交底,确保所有参加交底人员清除明白并做好交底记录;加强施工过程质量控制力度,切实贯彻落实“三级检查、四级验收制度”;严格杜绝将上道工序的质量隐患带入下道工序中,切实贯彻落实“上道工序不清、下道工序不接”的质量管理方针。7.5确保梁板柱混凝土施工质量7.5.1 作好混凝土浇筑的准备工作。确保施工道路畅通,施工机械工况良好。 7.5.2 加强混凝土施工现场行政、技术值班力度,保证混凝土施工按照施工方案和作业指导书要求连续施工,确保每个施工段梁板柱结构一次成型。 7.5.3 加强施工人员的后勤保障工作,混凝土浇筑施工停歇时间严禁超过45分钟。 7.6 工程质量管理和施工质量控制,必须遵守“事事有章可循,事事有据可查,事事有人负责,事事有人监督”的原则。7.7测量放线必须准确,认真检查,杜