BS EN 14343-2005 容积泵 验收性能试验 Rotary positive displacement pumps - Performance tests for acceptance.pdf

上传人:韩长文 文档编号:3643842 上传时间:2019-09-19 格式:PDF 页数:20 大小:152.18KB
返回 下载 相关 举报
BS EN 14343-2005 容积泵 验收性能试验 Rotary positive displacement pumps - Performance tests for acceptance.pdf_第1页
第1页 / 共20页
BS EN 14343-2005 容积泵 验收性能试验 Rotary positive displacement pumps - Performance tests for acceptance.pdf_第2页
第2页 / 共20页
BS EN 14343-2005 容积泵 验收性能试验 Rotary positive displacement pumps - Performance tests for acceptance.pdf_第3页
第3页 / 共20页
BS EN 14343-2005 容积泵 验收性能试验 Rotary positive displacement pumps - Performance tests for acceptance.pdf_第4页
第4页 / 共20页
BS EN 14343-2005 容积泵 验收性能试验 Rotary positive displacement pumps - Performance tests for acceptance.pdf_第5页
第5页 / 共20页
亲,该文档总共20页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS EN 14343-2005 容积泵 验收性能试验 Rotary positive displacement pumps - Performance tests for acceptance.pdf》由会员分享,可在线阅读,更多相关《BS EN 14343-2005 容积泵 验收性能试验 Rotary positive displacement pumps - Performance tests for acceptance.pdf(20页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 14343:2005 Rotary positive displacement pumps Performance tests for acceptance The European Standard EN 14343:2005 has the status of a British Standard ICS 23.080 ? Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Jul 30 11:11:33 BST 2006, Uncontro

2、lled Copy, (c) BSI BS EN 14343:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 17 February 2006 BSI 17 February 2006 ISBN 0 580 46996 4 National foreword This British Standard is the official English language version of EN 14343:2005. Th

3、e UK participation in its preparation was entrusted to Technical Committee MCE/6, Pumps and pump testing, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement interna

4、tional or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purpor

5、t to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee

6、any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 16, an ins

7、ide back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Jul 30 11:11:33 BST 2006, Uncontro

8、lled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14343 December 2005 ICS 23.080 English Version Rotary positive displacement pumps - Performance tests for acceptance Pompes volumtriques rotatives - Essais de performances pour la rception Rotierende Verdrngerpumpen - Leistungsp

9、rfung zur Abnahme This European Standard was approved by CEN on 26 October 2005. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and b

10、ibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibilit

11、y of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Ital

12、y, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brusse

13、ls 2005 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14343:2005: E Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Jul 30 11:11:33 BST 2006, Uncontrolled Copy, (c) BSI EN 14343:2005 (E) 2 Contents pa

14、ge Foreword 3 1Scope.4 2Normative references .4 3Terms and definitions.4 3.1General 4 3.2Types of test4 3.3Test levels5 3.4Other terms5 4Performance requirements.6 5Organisation6 5.1Responsibility for test 6 5.2Test location6 5.3Test date6 5.4Test programme6 6Equipment .7 6.1Test equipment .7 6.2Mea

15、surement equipment8 7Test conditions .9 7.1Test condition variables (TCV).9 7.2Fluctuations.9 8Test procedure10 8.1Pre-run data.10 8.2Operating the pump10 8.3Collection of test data.11 8.4After test11 9Evaluation and test report12 9.1Readings and primary data12 9.2Accuracy12 9.3Acceptance limits13 9

16、.4Evaluation13 9.5Test report.14 Annex A (informative) Example of rotary displacement pump test loop15 Annex B (informative) Priming test .16 Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Jul 30 11:11:33 BST 2006, Uncontrolled Copy, (c) BSI ? EN 14343:2005 (E) 3 Forew

17、ord This European Standard (EN 14343:2005) has been prepared by Technical Committee CEN/TC 197 “ Pumps” , the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by

18、 June 2006, and conflicting national standards shall be withdrawn at the latest by June 2006. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, De

19、nmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: Institute Of Technology Tallaght, Institute of Technology

20、, Sun Jul 30 11:11:33 BST 2006, Uncontrolled Copy, (c) BSI ? EN 14343:2005 (E) 4 1 Scope This European Standard describes specified types of acceptance tests for rotary positive displacement pumps for applications other than fluid power, excluding progressing cavity and peristaltic type pumps. This

21、European Standard applies to the testing of pumps with and without drivers. This European Standard covers a selection of tests to establish a uniform demonstration of the pumps ability to perform satisfactorily. It does not, however, cover all tests that may be needed for particular pump types or ap

22、plications, e.g. tests for hazardous liquids or single shaft multiple pump units. Furthermore, it does not cover any noise and vibration tests, priming tests nor any hydrostatic pressure tests. Some pump types with integral relief valves may require more extensive relief valve tests than described i

23、n this European Standard. For dosing and metering applications, further tests to demonstrate the dosing and metering abilities of the pumps may be necessary. NOTE Extrapolation of test results to non-tested pumps is not described in this European Standard. Such extrapolation could be made for mass-p

24、roduced pumps with reference to pertinent quality assurance methods and standards. 2 Normative references The following referenced documents are indispensable for the application of this European Standard. For dated references, only the edition cited applies. For undated references, the latest editi

25、on of the referenced document (including any amendments) applies. EN 10204, Metallic products Types of inspection documents EN 12723:2000, Liquid pumps General terms for pumps and installations Definitions, quantities, letter symbols and units EN ISO 10012, Measurement management systems Requirement

26、s for measurement processes and measuring equipment (ISO 10012:2003) 3 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 General For the purposes of this European Standard, the terminology, symbols and abbreviations as given in EN 12723:

27、2000 apply. 3.2 Types of test 3.2.1 T1 flow test test to verify that the pump flow is within a specified tolerance 3.2.2 T2 power test test to verify that the input power is within specified tolerances Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Jul 30 11:11:33 BST

28、2006, Uncontrolled Copy, (c) BSI ? EN 14343:2005 (E) 5 3.2.3 T3 inlet pressure test test to verify that the pump operates satisfactorily without cavitation at specified inlet pressure conditions NOTE The inlet pressure test T3 is not designed to establish the limit for cavitation, nor is it intended

29、 to establish the priming characteristics of the pump. Some guidance for priming tests is given in Annex B. Such a test, when required, may be made part of the test programme, but will require separate description of the test procedure and acceptance criteria, adapted to the subject type of pump. 3.

30、2.4 T4 relief valve test test to verify the pressure accumulation of a relief valve and its ability to reseat/close when the pressure is returned to normal 3.3 Test levels 3.3.1 L1 works test manufacturers internal quality assurance test. This test level is a pass/fail test without any formal record

31、ing requirements 3.3.2 L2 standard test manufacturers internal quality assurance test, with traceable records of pertinent test data 3.3.3 L3 order specified test test to verify the performance of a pump or pump unit at specified conditions. Test data are recorded 3.3.4 L4 observed test test to veri

32、fy the pump or pump unit performance at specified conditions. The purchaser is given an opportunity to have a representative present at test. Test data are recorded 3.3.5 L5 witness test test to verify the pump or pump unit performance at specified conditions. The purchaser needs a representative pr

33、esent at test (shall be a hold point). Test data are recorded 3.4 Other terms 3.4.1 test condition variables (TCV) those variables, such as pressure, speed and viscosity, that are directly controlled by the test arrangement and its operation 3.4.2 test result variables (TRV) those variables, such as

34、 flow and power consumption, that are obtained as a result of TCV and reflect the performance of the object under test 3.4.3 accuracy grade set of instrumentation and test equipment accuracy requirements 3.4.4 tolerance class set of tolerance requirements for TRV 3.4.5 pressure accumulation for the

35、purpose of this European Standard, pressure accumulation is considered as the difference between the maximum pressure observed during relief valve opening and the specified operating pressure. This value includes the margin between operating pressure and valve setting and the pressure increase by re

36、lief valve characteristic Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Jul 30 11:11:33 BST 2006, Uncontrolled Copy, (c) BSI ? EN 14343:2005 (E) 6 4 Performance requirements The supplier shall identify and specify in writing, prior to the test, the TCV values (test co

37、nditions) together with the corresponding requirement values of TRV (performance results) for each set. He shall also specify test level, accuracy grade and tolerance class relevant to the purpose of the test. NOTE For test levels L3, L4 and L5 the TCV (test condition variables) values should be sel

38、ected to conform as far as practical to the conditions of the order and agreed upon by manufacturer and purchaser. Unless otherwise specified and agreed between purchaser and supplier, the following default values shall apply: test type: T1 Flow test and, for pumps with integral valve or a valve dir

39、ectly attached to the pump body, T4 Relief valve test test level: L2 Standard test accuracy: Grade 2 tolerance: Class 2 5 Organisation 5.1 Responsibility for test The supplier shall be responsible for the appointment of a competent and experienced person to be in charge of the tests. The supplier sh

40、all also be responsible for ensuring compliance with all relevant safety regulations and standards, unless testing is performed at an independent laboratory or at site, when conformity to safety regulations shall be ensured by the party responsible for the test location. 5.2 Test location Unless oth

41、erwise specified, testing shall be carried out at the suppliers works. If so agreed between purchaser and supplier, the testing may be carried out either at an independent test facility or at site. 5.3 Test date The supplier shall determine the date of test. For observed or witness test (level L4 an

42、d L5), a minimum of 10 calendar days notice shall be provided to the purchaser unless otherwise agreed in advance. 5.4 Test programme The test procedure shall be described in a test programme prior to test. For observed test L4 or witness test L5, the test programme shall be made available to the pu

43、rchaser prior to test. The test programme shall include details on scheduling and responsibility for test, test methods and arrangements, performance requirements as per Clause 4 above, verification levels for inlet pressure tests T3, when applicable (see 9.4.2), sequence and timing of actions and o

44、bservations, recording of test data, methods for data corrections (see 7.1), presentation of results etc. Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sun Jul 30 11:11:33 BST 2006, Uncontrolled Copy, (c) BSI ? EN 14343:2005 (E) 7 6 Equipment 6.1 Test equipment 6.1.1 Gene

45、ral The pump under test shall be connected to a suitably dimensioned and rated test loop. Example of a test loop is given in Annex A. The test loop shall conform to the installation instruction given for the test pump. Special attention should be given to the alignment between pump and driver, possi

46、bilities to fill and drain the pump and to access for observation of leakage, vibration or other indications of malfunction. When necessary, an auxiliary loop for conditioning of the liquid, i.e. heating, cooling and/or filtering, shall be provided, see 6.1.3 and 6.1.4. 6.1.2 Test liquid The test li

47、quid shall be a Newtonian liquid of known characteristics selected by the manufacturer. Necessary liquid data, such as viscosity-temperature relationship, shall be available at the test stand, either in tabulated or graphical form, indicating the liquid designation and the date of issue and latest r

48、evision. The amount of test liquid shall be sufficient to allow it to settle in the tank and for this purpose the ratio of liquid volume to pump flow shall exceed 150 s, unless the purpose can be ascertained by other means, like highly efficient filtration and cooling. 6.1.3 Liquid temperature Means

49、 shall be provided to maintain an inlet temperature to the pump during test, constant within 1,5 C. 6.1.4 Liquid cleanliness If necessary, adequate filtration in order to maintain the cleanliness of the liquid within the limits specified for the pump under test shall be provided. 6.1.5 Entrained air For viscous test liquids and when otherwise so required, means shall be provided for separating un-dissolved air and gas f