BS EN 14411-2006 Ceramic tiles.pdf

上传人:韩长文 文档编号:3646428 上传时间:2019-09-19 格式:PDF 页数:70 大小:1,016.93KB
返回 下载 相关 举报
BS EN 14411-2006 Ceramic tiles.pdf_第1页
第1页 / 共70页
BS EN 14411-2006 Ceramic tiles.pdf_第2页
第2页 / 共70页
BS EN 14411-2006 Ceramic tiles.pdf_第3页
第3页 / 共70页
BS EN 14411-2006 Ceramic tiles.pdf_第4页
第4页 / 共70页
BS EN 14411-2006 Ceramic tiles.pdf_第5页
第5页 / 共70页
亲,该文档总共70页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS EN 14411-2006 Ceramic tiles.pdf》由会员分享,可在线阅读,更多相关《BS EN 14411-2006 Ceramic tiles.pdf(70页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 14411:2006 Ceramic tiles Definitions, classification, characteristics and marking The European Standard EN 14411:2006 has the status of a British Standard ICS 91.100.25 ? BS EN 14411:2006 This British Standard was published under the authority of the Standards Policy and Strat

2、egy Committee on 30 March 2007 BSI 2007 ISBN 978 0 580 50313 9 National foreword This British Standard was published by BSI. It is the UK implementation of EN 14411:2006. It supersedes BS EN 14411:2003 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee B

3、/539, Ceramic tiles and other rigid tiling. A list of organizations represented on B/539 can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British

4、Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. DateComments 标准分享网 w w w .b z f x w .c o m 免费下载 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14411 December 2006 ICS 91.100.25Supersedes EN 14411:2003 English Version Ceramic tiles - Definiti

5、ons, classification, characteristics and marking Carreaux et dalles cramiques - Dfinitions, classification, caractristiques et marquage Keramische Fliesen und Platten - Begriffe, Klassifizierung, Gtemerkmale und Kennzeichnung This European Standard was approved by CEN on 13 November 2006. CEN member

6、s are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application

7、 to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the sam

8、e status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Sl

9、ovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2006 CENAll rights of exploitation in any form and by any means reserved worldw

10、ide for CEN national Members. Ref. No. EN 14411:2006: E EN 14411:2006 (E) 2 Contents Page Foreword4 1 Scope 5 2 Normative references5 3 Terms and definitions .6 4 Classification8 4.1 Basis of classification.8 4.2 Methods of manufacture.8 4.3 Water absorption (E) groups9 5 Characteristics.9 6 Evaluat

11、ion of conformity.11 6.1 General11 6.2 Initial type testing 11 6.3 Factory production control.11 6.3.1 General11 6.3.2 Equipment 12 6.3.3 Product testing and evaluation12 6.3.4 Inspection and test records12 7 Sampling and basis for acceptance.13 8 Requirements.13 9 Marking and specifications.14 10 O

12、rdering14 Annex A (normative) Extruded ceramic tiles 0,5 10 % Group AIII.31 F.1 Requirements.31 Annex G (normative) Dry-pressed ceramic tiles with low water absorption E 0,5 % Group BIa.34 G.1 Requirements.34 Annex H (normative) Dry-pressed ceramic tiles with low water absorption 0,5 % 10 % Group BI

13、II.46 L.1 Requirements.46 Annex M (normative) Extruded ceramic tiles with low water absorption E 0,5 % Group AIa.49 M.1 Requirements.49 Annex N (informative) Classification of glazed tiles for floors according to their abrasion resistance.52 Annex P (informative) Test methods.53 Annex Q (normative)

14、Additional European requirements on tiles.54 Q.1 General .54 Q.2 Release of cadmium54 Q.3 Release of lead 54 Annex R (informative) Symbols for intended use55 ZA.1 Scope and general.57 ZA.2 Procedures for the attestation of conformity of products61 ZA.2.1 Procedures for the attestation of conformity

15、of flooring61 ZA.2.2 Procedures for the attestation of conformity of wall and ceiling finishes 61 ZA.3 CE marking and labelling62 ZA.3.1 CE marking.62 ZA.3.2 Examples of reference model for the marking and labelling63 ZA.4 EC Declaration of conformity.66 Bibliography67 EN 14411:2006 (E) 4 Foreword T

16、his document (EN 14411:2006) has been prepared by Technical Committee CEN/TC 67 “Ceramic tiles”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2007,

17、 and conflicting national standards shall be withdrawn at the latest by June 2007. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directi

18、ve(s), see informative Annex ZA, which is an integral part of this document. Test methods for determination of Impact resistance, release of lead and cadmium and small colour differences are now listed but no requirements are specified. This document supersedes EN 14411:2003. According to the CEN/CE

19、NELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Ma

20、lta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. 标准分享网 w w w .b z f x w .c o m 免费下载 EN 14411:2006 (E) 5 1 Scope This European Standard defines and gives terms, specifies requirements and marking criteria for ceramic tiles (produc

21、ed by extrusion and dry-pressing techniques) of the best commercial quality (first quality). Tiles not of first commercial quality are also covered following the provisions of Annex Q. This European Standard does not cover tiles made by other than the normal processes of extrusion or dry- pressing n

22、or decorative accessories or trim (such as edges, corners, skirting, capping, coves, beads, steps, curved tiles and other accessory pieces) or mosaics (i.e. any piece that can fit into a 7 cm 7 cm area, see custom nomenclature). NOTE EN ISO 10545 describes the test procedures required to determine t

23、he product characteristics listed in this European Standard. EN ISO 10545 is divided into parts, each describing a specific test procedure or related matter. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only t

24、he edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12004, Adhesives for tiles Definitions and specifications EN ISO 10545-1, Ceramic tiles Part 1: Sampling and basis for acceptance (ISO 10545-1:1995) EN ISO 10545-2,

25、Ceramic tiles Part 2: Determination of dimensions and surface quality (ISO 10545-2:1995, including Technical Corrigendum 1:1997) EN ISO 10545-3, Ceramic tiles Part 3: Determination of water absorption, apparent porosity, apparent relative density and bulk density (ISO 10545-3:1995, including Technic

26、al Corrigendum 1:1997) EN ISO 10545-4, Ceramic tiles Part 4: Determination of modulus of rupture and breaking strength (ISO 10545-4:1995) EN ISO 10545-5, Ceramic tiles Part 5: Determination of impact resistance by measurement of coefficient of restitution (ISO 10545-5:1996, including Technical Corri

27、gendum 1:1996) EN ISO 10545-6, Ceramic tiles Part 6: Determination of resistance to deep abrasion for unglazed tiles (ISO 10545-6:1995) EN ISO 10545-7, Ceramic tiles Part 7: Determination of resistance to surface abrasion for glazed tiles (ISO 10545-7:1996) EN ISO 10545-8, Ceramic tiles Part 8: Dete

28、rmination of linear thermal expansion (ISO 10545-8:1994) EN ISO 10545-9, Ceramic tiles Part 9: Determination of resistance to thermal shock (ISO 10545-9:1994) EN ISO 10545-10, Ceramic tiles Part 10: Determination of moisture expansion (ISO 10545-10:1995) EN ISO 10545-11, Ceramic tiles Part 11: Deter

29、mination of crazing resistance for glazed tiles (ISO 10545- 11:1994) EN ISO 10545-12, Ceramic tiles Part 12: Determination of frost resistance (ISO 10545-12:1995, including Technical Corrigendum 1:1997) EN ISO 10545-13, Ceramic tiles Part 13: Determination of chemical resistance (ISO 10545-13:1995)

30、EN 14411:2006 (E) 6 EN ISO 10545-14, Ceramic tiles Part 14: Determination of resistance to stains (ISO 10545-14:1995, including Technical Corrigendum 1:1997) EN ISO 10545-15, Ceramic tiles Part 15: Determination of lead and cadmium given off by glazed tiles (ISO 10545-15:1995) EN ISO 10545-16, Ceram

31、ic tiles Part 16: Determination of small colour differences (ISO 10545-16:1999) ISO 1006:1983, Building construction Modular coordination Basic module 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 1006:1983 and the following apply. 3.1 ceramic tile

32、 slab made from clays and/or other inorganic raw materials NOTE 1 Tiles are generally used as coverings for floors and walls. They are usually shaped by extruding (Method A) or dry-pressing (Method B) at room temperature followed by drying and firing at temperatures sufficient to develop the require

33、d properties, but can be formed by other processes. Tiles can be glazed (GL) or unglazed (UGL) and are incombustible and unaffected by light NOTE 2 A fully vitrified (or porcelain) tile is a tile with water absorption lower than 0,5 %. 3.2 glaze vitrified covering 3.3 engobed surface clay-based cove

34、ring with a matt finish which can be permeable or impermeable NOTE A tile with an engobed surface is regarded as an unglazed tile. 3.4 polished surface surface of a glazed or unglazed tile which has been given a glossy finish by mechanical polishing carried out after firing 3.5 extruded tile tile wh

35、ose body is shaped in the plastic state in an extruder, the column obtained being cut into tiles of pre- determined dimension NOTE 1 This European Standard classifies extruded tiles as “precision” or “natural”. The classification is dependent upon the different technical characteristics as listed in

36、 the normative Annexes A to F and R. NOTE 2 Traditional terms used for extruded products are “split tiles” and “quarry tiles”. They commonly indicate double- extruded and single-extruded tiles respectively. The term “quarry tiles” only refers to extruded tiles with a water absorption not exceeding 6

37、 %. NOTE 3 Extruded tiles include the letter A in their designation (see Table 1). 3.6 dry-pressed tile tile formed from a finely milled body mixture and shaped by pressing 标准分享网 w w w .b z f x w .c o m 免费下载 EN 14411:2006 (E) 7 NOTE Dry-pressed tiles include the letter B in their designation (see Ta

38、ble 1) 3.7 spacer lug projection which is located along certain edges of tiles so that when two tiles are placed together, in line, the lugs on adjacent edges separate the tiles by a distance not less than the specified width of the joint NOTE 1 Lugs are positioned so that the joint between the tile

39、s may be filled with grout without the lugs remaining exposed. NOTE 2 Dry-pressed tiles may be made with other spacer lug systems and, in such cases, the manufacturers work size applies. NOTE 3 The use of spacer lugs are illustrated in Figure 2. 3.8 water absorption (symbol E) percentage of water by

40、 mass, measured in accordance with EN ISO 10545-3 3.9 description of sizes see Figures 1 and 2 NOTE These are only defined for rectangular tiles. If the sizes of non-rectangular tiles are required, they are defined by the smallest rectangle into which they will fit. 3.9.1 nominal size size used to d

41、escribe the product 3.9.2 work size (symbol W) size of a tile specified for manufacturing to which the actual size has to conform within specified permissible deviations NOTE This is specified by the dimensions length, width and thickness. 3.9.3 actual size size obtained by measuring the face of the

42、 tile in accordance with EN ISO 10545-2 3.9.4 coordinating size (symbol C) work size plus the joint width 3.9.5 modular size dimensions based on the modules M, and also their multiples or subdivisions, except for tiles with a surface area of less than 9 000 mm2 NOTE See ISO 1006 where 1 M = 100 mm.

43、3.9.6 non-modular size size not based on module M NOTE See ISO 1006 where 1 M = 100 mm. 3.9.7 tolerance difference between the permissible limits EN 14411:2006 (E) 8 3.10 product group ceramic tiles manufactured through a defined process (extrusion or dry pressing) and featuring a specific porosity

44、or water absorption 3.11 family in a product group ceramic tiles manufactured for which the test results of any one product within the family are valid for all other products within the family NOTE Families can be defined in terms of body characteristics (same size and thickness) or surface finish c

45、haracteristics (same glaze and/or decoration composition and properties). 4 Classification 4.1 Basis of classification Ceramic tiles are divided into groups according to their method of manufacture and their water absorption (see 3.8 and Table 1). The groups do not presuppose the usage of the produc

46、ts. Table 1 Classification of ceramic tiles with respect to water absorption and shaping Shaping Group I E 3 % Group IIa 3 % 10 % A Extruded Group AIa E 0,5 % (see Annex M) Group AIb 0,5 % 10 % 5 Characteristics The characteristics for different applications of ceramic tiles are given in Table 2. EN

47、 14411:2006 (E) 10 Table 2 Characteristics required for different applications Characteristics Floors Walls Test Dimensions and surface quality Interior Exterior Interior Exterior Reference Length and width X X X X EN ISO 10545-2 Thickness X X X X EN ISO 10545-2 Straightness of sides X X X X EN ISO

48、10545-2 Rectangularity X X X X EN ISO 10545-2 Surface flatness (curvature and warpage) X X X X EN ISO 10545-2 Surface quality X X X X EN ISO 10545-2 Physical properties Interior Exterior Interior Exterior Reference Water absorption X X X X EN ISO 10545-3 Breaking strength X X X X EN ISO 10545-4 Modu

49、lus of rupture X X X X EN ISO 10545-4 Resistance to deep abrasion unglazed tiles X X EN ISO 10545-6 Resistance to surface abrasion glazed tiles X X EN ISO 10545-7 Linear thermal expansion a X X X X EN ISO 10545-8 Resistance to thermal shock a X X X X EN ISO 10545-9 Resistance to crazing glazed tiles X X X X EN ISO 10545-11 Frost resistance b X X EN ISO 10545-12 Coefficient of friction X X Declare test method used Mois