BS EN 54-13-2005 Fire detection and fire alarm systems — Part 13 Compatibility assessment of system components.pdf

上传人:来看看 文档编号:3646730 上传时间:2019-09-19 格式:PDF 页数:26 大小:166.41KB
返回 下载 相关 举报
BS EN 54-13-2005 Fire detection and fire alarm systems — Part 13 Compatibility assessment of system components.pdf_第1页
第1页 / 共26页
BS EN 54-13-2005 Fire detection and fire alarm systems — Part 13 Compatibility assessment of system components.pdf_第2页
第2页 / 共26页
BS EN 54-13-2005 Fire detection and fire alarm systems — Part 13 Compatibility assessment of system components.pdf_第3页
第3页 / 共26页
BS EN 54-13-2005 Fire detection and fire alarm systems — Part 13 Compatibility assessment of system components.pdf_第4页
第4页 / 共26页
BS EN 54-13-2005 Fire detection and fire alarm systems — Part 13 Compatibility assessment of system components.pdf_第5页
第5页 / 共26页
亲,该文档总共26页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS EN 54-13-2005 Fire detection and fire alarm systems — Part 13 Compatibility assessment of system components.pdf》由会员分享,可在线阅读,更多相关《BS EN 54-13-2005 Fire detection and fire alarm systems — Part 13 Compatibility assessment of system components.pdf(26页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 54-13:2005 Fire detection and fire alarm systems Part 13: Compatibility assessment of system components The European Standard EN 54-13:2005 has the status of a British Standard ICS 13.220.20 ? Licensed Copy: London South Bank University, London South Bank University, Thu Oct 1

2、9 13:10:47 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 54-13:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 24 June 2005 BSI 24 June 2005 ISBN 0 580 46213 7 National foreword This British Standard is the official English language v

3、ersion of EN 54-13:2005. The UK participation in its preparation was entrusted by Technical Committee FSH/12, Fire Detection and Alarm Systems, to Subcommittee FSH/12/1, Installation and Servicing, which has the responsibility to: A list of organizations represented on this subcommittee can be obtai

4、ned on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “ International Standards Correspondence Index” , or by using the “ Search” facilit

5、y of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations.

6、aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages

7、This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 23 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: London South Bank

8、 University, London South Bank University, Thu Oct 19 13:10:47 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 54-13 May 2005 ICS 13.220.20 English version Fire detection and fire alarm systems - Part 13: Compatibility assessment of system components S

9、ystmes de dtection et dalarme incendie - Partie 13 : valuation de la compatibilit des composants dun systme Brandmeldeanlagen - Teil 13: Bewertung der Kompatibilitt von Systembestandteilen This European Standard was approved by CEN on 28 February 2005. CEN members are bound to comply with the CEN/CE

10、NELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any

11、 CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CE

12、N members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland a

13、nd United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2005 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 54-1

14、3:2005: E Licensed Copy: London South Bank University, London South Bank University, Thu Oct 19 13:10:47 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 54-13:2005 (E) 2 ContentsPage Foreword3 Introduction .4 1Scope.5 2Normative references.5 3Terms, definitions and abbreviations .5 3.1Terms and defini

15、tions 5 4Requirements7 4.1Compliance.7 4.2Basic system requirements.7 4.3Networked systems7 4.4Components8 4.5Transmission path(s) .9 4.6Input and output devices linked to a fire protection system.9 4.7Documentation .10 5Assessment methods and tests11 5.1General requirements.11 5.2General test requi

16、rements .12 5.3Functional test for compatibility .12 5.4Functional test for connectability .15 5.5Electromagnetic compatibility tests16 Annex A (normative) Functions of a FDAS 17 Annex B (informative) Classification of functions of the FDAS18 Annex C (informative) Example methodology for theoretical

17、 analysis20 Licensed Copy: London South Bank University, London South Bank University, Thu Oct 19 13:10:47 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? EN 54-13:2005 (E) 3 Foreword This document (EN 54-13:2005) has been prepared by Technical Committee CEN/TC 72 “ Fire detection and fire alarm system

18、s” , the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2005, and conflicting national standards shall be withdrawn at the latest by May 2007. Accord

19、ing to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, N

20、orway, Poland, Portugal, Slovakia, Spain, Sweden, Switzerland and the United Kingdom. This document has been prepared in co-operation with the CEA (Comit Europen des Assurances) and with EURALARM (Association of European Manufacturers of Fire and Intruder Alarm Systems). EN 54 is published in a seri

21、es of parts. Information on the relationship between this document and other standards of the EN 54 series is given in Annex A of EN 54-1:1996. EN 54-1 provides additional information about the components performing those functions that are listed in Annex A of this document. Licensed Copy: London S

22、outh Bank University, London South Bank University, Thu Oct 19 13:10:47 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? EN 54-13:2005 (E) 4 Introduction The fire detection function is to detect a fire at the earliest practicable moment, and to give signals and indications so that appropriate action can

23、 be taken. The fire alarm function is to give, at least, audible and/or visible signals to the occupants of a building who may be at risk from fire. A fire detection and fire alarm system may combine the functions of detection and alarm in a single system, and typically consists of a number of inter

24、-linked components including automatic fire detectors, manual call points and alarm sounders. These components are connected to control and indicating equipment by means of one or more transmission paths. All system components, including the control and indicating equipment, are also directly or ind

25、irectly connected to a power supply. A fire detection and fire alarm system may also be linked to remote fault and fire alarm monitoring stations, and to fire protection and/or building management systems. However these systems are not considered as part of the fire detection and fire alarm system.

26、It is necessary that all the components constituting the fire detection and fire alarm system are compatible or connectable, and that requirements relating to the performance of the overall system are fulfilled. Differentiation is made between components classified as components type 1 and other com

27、ponents classified as components type 2. System requirements are also included for those fire detection and fire alarm systems that are linked to fire protection and/or other systems (e.g. building management systems). Licensed Copy: London South Bank University, London South Bank University, Thu Oc

28、t 19 13:10:47 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? EN 54-13:2005 (E) 5 1 Scope This document specifies the requirements for compatibility and connectability assessment of system components that either comply with the requirements of EN 54 or with a manufacturer s specification where there is

29、 no EN 54 standard. This document only includes system requirements when these are necessary for compatibility assessment. This document also specifies requirements for the integrity of the fire detection and fire alarm system when connected to other systems. This document does not specify the manne

30、r in which the system is designed, installed and used in any particular application. This document recognizes that it is not practical to assess the compatibility or connectability of components in all possible configurations. Methods of assessment are specified to reach an acceptable degree of conf

31、idence within pre-determined operational and environmental conditions. This document specifies requirements related to compatibility and connectability assessment methods and tests for the system components. This document is applicable to systems where the components are connected to control and ind

32、icating equipment and where the components are interconnected by electrical wires. For fire detection and fire alarm systems that use other means of interconnection (for example optical fibre or radio frequency links), this document may be used as guidance. NOTE Other European Standards are expected

33、 to cover the requirements of the other systems to which the fire detection and fire alarm system may be connected. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated refe

34、rences, the latest edition of the referenced document (including any amendments) applies. EN 54-1:1996, Fire detection and fire alarm systems Part 1: Introduction EN 54-2:1997, Fire detection and fire alarm systems Part 2: Control and indicating equipment EN 50130-4, Alarm systems Part 4: Electromag

35、netic compatibility Product family standard: Immunity requirements for components of fire, intruder and social alarm systems EN 60068-1, Environmental testing Part 1: General and guidance (IEC 60068-1:1988 + Corrigendum 1998 + A1:1992) 3 Terms, definitions and abbreviations 3.1 Terms and definitions

36、 For the purposes of this document, the terms and definitions given in EN 54-1:1996 and the following apply. 3.1.1 compatibility ability of a component type 1 to operate with control and indicating equipment: Licensed Copy: London South Bank University, London South Bank University, Thu Oct 19 13:10

37、:47 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? EN 54-13:2005 (E) 6 within the limits specified for each component; within the specified limits given by the relevant parts of EN 54 if available, or given by the manufacturer if not available; within specified configurations of systems 3.1.2 componen

38、t type 1 device performing a function for the protection of life and/or property that is required by European or national guidelines or regulations 3.1.3 component type 2 device performing a function for the protection of life and/or property that is not required by European or national guidelines o

39、r regulations EXAMPLE A printer used for listing fire events. 3.1.4 configuration topological arrangement of components connected through transmission paths to control and indicating equipment 3.1.5 connectability ability of component type 2 to operate without jeopardizing the performance of the fir

40、e detection and fire alarm system 3.1.6 control and indicating equipment CIE component of a fire detection and alarm system through which other components may be supplied with power (see EN 54-1) 3.1.7 fire detection and fire alarm system FDAS group of components including a CIE which, when arranged

41、 in (a) specified configuration(s), is capable of detecting and indicating a fire, and giving signals for appropriate action 3.1.8 fire protection system FPS group of devices that in combination are capable of automatically actuating measures to limit the effect of fire EXAMPLE Compartmentation syst

42、ems, smoke control systems and fixed firefighting systems. 3.1.9 hierarchical system networked system in which one control and indicating equipment is designated as the main control and indicating equipment, and in which the main control and indicating equipment is able to: receive signals from and/

43、or transmit signals to the control and indicating equipment of a subsystem; indicate the status of the control and indicating equipment of a subsystem Licensed Copy: London South Bank University, London South Bank University, Thu Oct 19 13:10:47 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ? EN 54-13:

44、2005 (E) 7 3.1.10 input/output device device that is connected to a transmission path of a fire detection and fire alarm system and is used to receive and/or transmit information to, from or within the system 3.1.11 networked system fire detection and fire alarm system in which more than one control

45、 and indicating equipment are interconnected and able to exchange information 3.1.12 subsystem part of a hierarchical system which includes only one control and indicating equipment 3.1.13 transmission path physical connection between the components (external to the housing of the components) used f

46、or the transmission of information and/or power 4 Requirements 4.1 Compliance In order to comply with this standard, the system design and compatibility or connectability of its components shall meet the requirements of this clause. This shall be verified by assessment (5.1) with reference to the re

47、quired documentation (4.7), shall be tested (if necessary) as described in 5.2 to 5.5 and shall meet the requirements of the tests. 4.2 Basic system requirements System requirements can also be stated in national application guidelines (also known as codes of practice). Suppliers of components shall

48、 ensure that they: meet the requirements of this document; meet the requirements of the relevant part of EN 54; meet the requirements of the application guidelines of the countries where the components are intended to be placed on the market. 4.2.1 The FDAS under consideration shall carry out fire d

49、etection functions identified in Annex A. All the different system configurations intended to be used shall be mentioned within the supplier documentation. 4.2.2 If a function of a FDAS is shared with any other system, it shall not jeopardize the FDAS. Shared functions shall meet the most onerous requirements of the relevant specifications. 4.2.3 If a non-FDAS function is performed by a component of a FDAS, thi

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1