BS EN 61557-7-2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. — Equipment for testing, measuring or monitoring of protective measures — Part 7.pdf

上传人:爱问知识人 文档编号:3647918 上传时间:2019-09-19 格式:PDF 页数:12 大小:402.97KB
返回 下载 相关 举报
BS EN 61557-7-2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. — Equipment for testing, measuring or monitoring of protective measures — Part 7.pdf_第1页
第1页 / 共12页
BS EN 61557-7-2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. — Equipment for testing, measuring or monitoring of protective measures — Part 7.pdf_第2页
第2页 / 共12页
BS EN 61557-7-2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. — Equipment for testing, measuring or monitoring of protective measures — Part 7.pdf_第3页
第3页 / 共12页
BS EN 61557-7-2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. — Equipment for testing, measuring or monitoring of protective measures — Part 7.pdf_第4页
第4页 / 共12页
BS EN 61557-7-2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. — Equipment for testing, measuring or monitoring of protective measures — Part 7.pdf_第5页
第5页 / 共12页
亲,该文档总共12页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS EN 61557-7-2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. — Equipment for testing, measuring or monitoring of protective measures — Part 7.pdf》由会员分享,可在线阅读,更多相关《BS EN 61557-7-2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. — Equipment for testing, measuring or monitoring of protective measures — Part 7.pdf(12页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 61557-7:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Part 7: Phase sequence The European Standard EN 61557-7:2007 has the status of a British Standard ICS 17

2、.220.20; 29.080.01; 29.240.01 ? Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 61557-7:2007 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 June 2007 BSI 2007 ISBN 978 0 580 50857 8 Nation

3、al foreword This British Standard was published by BSI. It is the UK implementation of EN 61557-7:2007. It is identical with IEC 61557-7:2007. It supersedes BS EN 61557-7:1997, which will be withdrawn on 1 March 2010. The UK participation in its preparation was entrusted to Technical Committee PEL/8

4、5, Measuring equipment for electrical and electromagnetic quantities. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct appl

5、ication. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. DateComments Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 61557-7 NORME EUROPENNE EUROPISCHE NOR

6、M March 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any me

7、ans reserved worldwide for CENELEC members. Ref. No. EN 61557-7:2007 E ICS 17.220.20; 29.080.01; 29.240.01 Supersedes EN 61557-7:1997 English version Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protecti

8、ve measures - Part 7: Phase sequence (IEC 61557-7:2007) Scurit lectrique dans les rseaux de distribution basse tension de 1 000 V c.a. et 1 500 V c.c. - Dispositifs de contrle, de mesure ou de surveillance de mesures de protection - Partie 7: Ordre de phases (CEI 61557-7:2007) Elektrische Sicherheit

9、 in Niederspannungsnetzen bis AC 1000 V und DC 1500 V - Gerte zum Prfen, Messen oder berwachen von Schutzmanahmen - Teil 7: Drehfeld (IEC 61557-7:2007) This European Standard was approved by CENELEC on 2007-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which st

10、ipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Stan

11、dard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the natio

12、nal electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden

13、, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Foreword The text of document 85/295/FDIS, future edition 2 of IEC 61557-7, prepared by IEC TC 85, Measuring equipment for electrical and electromagnetic quantities, was

14、submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61557-7 on 2007-03-01. This European Standard supersedes EN 61557-7:1997. This standard is to be used in conjunction with EN 61557-1. The following dates were fixed: latest date by which the EN has to be implemented at nati

15、onal level by publication of an identical national standard or by endorsement (dop) 2007-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-03-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC

16、 61557-7:2007 was approved by CENELEC as a European Standard without any modification. _ EN 61557-7:2007 2 Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI CONTENTS 1 Scope.4 2 Normative references4 3 Terms and definitions .4 4 Requirements .4 5 Marking and

17、 operating instructions5 5.1 Marking .5 5.2 Operating instructions6 6 Tests6 Annex A (normative) Illustrations for mechanical tests8 Figure A.1 Mechanical shock test .8 Figure A.2 Drop test.8 Annex ZA (normative) Normative references to international publications with their corresponding European pu

18、blications9 EN 61557-7:2007 3 Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 000 V a.c. AND 1 500 V d.c. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES Part 7: Phase sequ

19、ence 1 Scope This part of IEC 61557 specifies the requirements for measuring equipment applied to testing the phase sequence in three-phase distribution systems. Indication of the phase sequence may be mechanical, visual and/or audible. This part of IEC 61557 does not apply to ancillary measuring eq

20、uipment for other quantities, for example voltage testers comprising an additional phase sequence indicator. It does not apply to monitoring relays. NOTE Phase lamps are not considered to be voltage testers. 2 Normative references The following referenced documents are indispensable for the applicat

21、ion of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60417, Graphical symbols for use on equipment IEC 61010-3-031, Safety requirements for electrical equipment for me

22、asurement, control, and laboratory use Part 3-031: Conformity verification report for IEC 61010-031:2002 Safety requirements for hand-held probe assemblies for electrical test and measurement IEC 61557-1, Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equip

23、ment for testing, measuring or monitoring of protective measures Part 1: General requirements 3 Terms and definitions For the purposes of this document, the definitions given in IEC 61557-1 apply. 4 Requirements The following requirements as well as those given in IEC 61557-1 shall apply. 4.1 Indica

24、tion shall be unambiguous between 85 % and 110 % of the nominal system voltage or within the range of the nominal voltage and between 95 % and 105 % of the nominal system frequency. 4.2 Indication shall also be unambiguously detectable in the presence of visual or audible interference. EN 61557-7:20

25、07 4 Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 标准分享网 www. b z f x w. c o m 4.3 The measuring equipment shall be suitable for continuous operation. 4.4 Portable measuring equipment shall be housed in an enclosure of insulating material and comply with

26、 double insulation or reinforced insulation (protection class II). 4.5 Portable measuring equipment shall be designed in such a manner that when either one or two measuring leads are connected to earth and the remaining measuring leads are connected to their corresponding phase conductors, the resul

27、ting total current to earth should not exceed 3,5 mA r.m.s. The phase conductors shall be at 110 % of the maximum rated voltage for which the equipment is designed. 4.6 The measuring equipment shall not be damaged nor shall the user be exposed to danger when the measuring equipment is connected to 1

28、20 % of the rated system voltage or to 120 % of its rated maximum voltage range. 4.7 Portable measuring equipment shall be provided with permanently attached leads or with a plug device with live parts not accessible, whether plugged or unplugged (according to IEC 61010-3-031). The following applies

29、 to leads they shall have an outer diameter of at least 3,5 mm; the copper cross-section shall be at least 0,75 mm; they shall be made from individual wires with a diameter 0,07 mm; they shall be provided with double or reinforced insulation. 4.8 Portable measuring equipment, together with their lea

30、ds, shall comply with the mechanical requirements and shall be tested in accordance with 6.3. After these tests: the enclosure of the measuring equipment shall be free from damage; permanently attached leads shall not have become detached from the measuring equipment; live parts of the leads connect

31、ed by means of plugs shall remain inaccessible when they have become unplugged from the measuring equipment; no parts inside the measuring equipment shall have become loose. 4.9 Requirements given in 4.8 need not apply when the phase sequence indicator forms part of multi-purpose measuring equipment

32、, provided that the following conditions are met: live parts of the leads remain inaccessible even when they have become unplugged from the measuring equipment; the measuring equipment shall be suitable for being carried, for example over the shoulder, when measurements are carried out. 5 Marking an

33、d operating instructions 5.1 Marking In addition to the marking in accordance with IEC 61557-1, the following information shall be provided on the measuring equipment. EN 61557-7:2007 5 Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 5.1.1 Symbol for the p

34、rotection class in accordance with symbol IEC 60417-5172 (2003-02). 5.1.2 Phase sequence. 5.1.3 Designation of the leads L1, L2 and L3 on the equipment and on the leads. 5.2 Operating instructions The operating instructions need not include any statements other than the statements given in IEC 61557

35、-1, except for the equipment mentioned in 4.9. 6 Tests In addition to IEC 61557-1, with the exception of the tests given in 6.1 to 6.3 of that standard, the following tests shall be executed. 6.1 Test of the detectability of the indication in accordance with 4.1 and 4.2. 6.1.1 Tests of the visual di

36、splay are executed under the following conditions (type tests). The display shall be unambiguously discernible from a distance of 500 mm at lighting levels from 30 lx to 1 000 lx. During the measurement, the measuring equipment shall be placed on a matt grey surface. A visual comparison under refere

37、nce conditions with equipment that has successfully passed the test is adequate for a routine test with respect to the visual display. The display on the item under test shall produce a similar or better readability. 6.1.2 The test for the audible indication is executed at a sound level of 75 dB(A)

38、(white noise). The indication shall be unambiguously discernible under these conditions (routine test). 6.2 Proof of compliance with the requirements under 4.5 shall be provided as follows: The phase sequence indicator shall be connected in series with a current measuring instrument on one lead conn

39、ected with earth, and with the interconnected other leads connected with a phase conductor at a voltage of 110 % of its rated voltage or a voltage at the upper limit of its rated voltage range. The magnitude of the current shall not exceed the value under 4.5. This test shall be executed on each con

40、ductor (routine test). 6.3 Test of mechanical requirements (type test) 6.3.1 For the purpose of a mechanical shock test, the item under test shall be suspended as shown in Figure A.1, using a pendulum length of 2 m. The item under test shall be dropped in a pendulum movement with a deflection of 1 m

41、 in height to hit a hard wooden plate 50 mm thick. The test shall be carried out so that each of the sides of the enclosure parallel to the suspension hits the wood once. EN 61557-7:2007 6 Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 标准分享网 www. b z f x

42、w. c o m 6.3.2 The strain relief of permanently attached leads shall be tested by a drop test in accordance with Figure A.2, in the following manner: the item under test shall be suspended so that it is caught with the extended lead after a free drop of 2 m; the item under test shall be dropped thre

43、e times from the suspension point for each of the leads. 6.4 Compliance with the requirements given in 4.6 shall be checked by visual inspection or by measurement (type test). 6.5 Compliance with the requirements given in 4.6 shall be tested by connecting, for a duration of 10 min, the item under te

44、st to a three-phase system at 120 % of the rated system voltage or, in the case of multi-range measuring equipment, at 120 % of all rated voltages (type test). 6.6 Compliance with the requirements given in 4.3 shall be tested by operating the item under test for a duration of 1 h at the rated voltag

45、e or, in the case of multi-range measuring equipment, at all rated voltage values (type test). 6.7 The markings shall be checked in respect of legibility by a visual inspection (type test). 6.8 Compliance with the requirements given in 4.9 shall be tested by visual inspection of the sling and with p

46、robe assemblies plugged and unplugged (type test). 6.9 The compliance with the tests in this clause shall be recorded. EN 61557-7:2007 7 Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Annex A (normative) Illustrations for mechanical tests 2 m 1 m IEC 077/

47、07 Figure A.1 Mechanical shock test B End position after the release of the equipment A 2 m a Original lead b Joint c Extension to 2 m A Initial position where the equipment is held a b c B IEC 078/07 Figure A.2 Drop test _ EN 61557-7:2007 8 Licensed Copy: Wang Bin, na, Fri Sep 14 00:54:42 GMT+00:00

48、 2007, Uncontrolled Copy, (c) BSI 标准分享网 www. b z f x w. c o m Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only t

49、he edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60417 Data- base Graphical symbols for use on equipment - -