1、a Date: 7 March 2007 Origin: International Latest date for receipt of comments: 15 June 2007 Project no.: 2004/00262 Responsible committee: IST/44 Biometrics Interested committees: Title: Draft ISO/IEC 24713-2 Information technology Biometric Profiles for Interoperability and Data Interchange - Part

2、 2: Physical Access Control for Employees at Airports Supersession information: If this document is published as a standard, the UK implementation of it will supersede NONE and partially supersede NONE . If you are aware of a current national standard which may be affected, please notify the secreta

3、ry (contact details below). WARNING: THIS IS A DRAFT AND MUST NOT BE REGARDED OR USED AS A BRITISH STANDARD. THIS DRAFT IS NOT CURRENT BEYOND 15 June 2007. This draft is issued to allow comments from interested parties; all comments will be given consideration prior to publication. No acknowledgemen

4、t will normally be sent. See overleaf for information on commenting. No copying is allowed, in any form, without prior written permission from BSI except as permitted under the Copyright, Designs and Patent Act 1988 or for circulation within a nominating organization for briefing purposes. Electroni

5、c circulation is limited to dissemination by e-mail within such an organization by committee members. Further copies of this draft may be purchased from BSI Customer Services, Tel: +44(0) 20 8996 9001 or email ordersbsi-. British, International and foreign standards are also available from BSI Custo

6、mer Services. British Standards on CD or Online are available from British Standards Publishing Sales Limited. Tel: 01344 404409 or email bsonlinetechindex.co.uk. Information on the co-operating organizations represented on the committees referenced above may be obtained from the responsible committ

7、ee secretary. Cross-references The British Standards which implement International or European publications referred to in this draft may be found via the British Standards Online Service on the BSI web site http:/www.bsi-. Direct tel: 020 8996 7430 Responsible Committee Secretary: Ms A E B Cassidy

8、(BSI) E-mail: anne.cassidybsi- Draft for Public Comment Head Office 389 Chiswick High Road London W4 4AL Telephone: +44(0)20 8996 9000 Fax: +44(0)20 8996 7001 Form 36 Version 6.1 DPC: 07/30107763 DC Licensed Copy: London South Bank University, London South Bank University, Sat Mar 17 03:57:05 GMT+00

9、:00 2007, Uncontrolled Copy, (c) BSI b Introduction This draft standard is based on international discussions in which the UK has taken an active part. Your comments on this draft are welcome and will assist in the preparation of the consequent standard. If no comments are received to the contrary,

10、then the UK will approve this draft. There is a high probability that this text could be adopted by CENELEC as a reference document for harmonization or as a European Standard. Recipients of this draft are requested to comment on the text bearing in mind this possibility. UK Vote Please indicate whe

11、ther you consider the UK should submit a negative (with reasons) or positive vote on this draft. BSI Committee Responsibilities Whether or not the standard is published in its original (international) form, or as a formal British Standard Implementation, the BSI committees responsibilities are to: -

12、 aid enquirers to understand the text; - present to the responsible international committee any enquiries on interpretation, or proposals for change, and keep UK interests informed; - monitor related International and European developments and promulgate them in the UK. Submission The guidance given

13、 below is intended to ensure that all comments receive efficient and appropriate attention by the responsible BSI committee. Annotated drafts are not acceptable and will be rejected. All comments must be submitted, preferably electronically, to the Responsible Committee Secretary at the address give

14、n on the front cover. Comments should be compatible with Version 6.0 or Version 97 of Microsoft Word for Windows, if possible; otherwise comments in ASCII text format are acceptable. Any comments not submitted electronically should still adhere to these format requirements. All comments submitted sh

15、ould be presented as given in the example below. Further information on submitting comments and how to obtain a blank electronic version of a comment form are available from the BSI web site at:http:/www.bsi- Template for comments and secretariat observations Date: xx/xx/200x Document: ISO/DIS xxxxx

16、 1 2 (3) 4 5 (6) (7) MB Clause No./ Subclause No./ Annex (e.g. 3.1) Paragraph/ Figure/Table/ Note (e.g. Table 1) Type of com- ment Comment (justification for change) by the MB Proposed change by the MB Secretariat observations on each comment submitted 3.1 Definition 1 ed Definition is ambiguous and

17、 needs clarifying. Amend to read . so that the mains connector to which no connection . 6.4 Paragraph 2 te The use of the UV photometer as an alternative cannot be supported as serious problems have been encountered in its use in the UK. Delete reference to UV photometer. Microsoft and MS-DOS are re

18、gistered trademarks, and Windows is a trademark of Microsoft Corporation. Licensed Copy: London South Bank University, London South Bank University, Sat Mar 17 03:57:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI ISO/IEC JTC 1/SC 37 N 1997 Secretariat, ISO/IEC JTC 1/SC 37, American National Standards

19、 Institute, 25 West 43rd Street, New York, NY 10036; Telephone: 1 212 642 4932; Facsimile: 1 212 840 2298; Email: lrajchelansi.org 2007-02-28 ISO/IEC JTC 1/SC 37 Biometrics Document Type: Text for FCD ballot Document Title: Text of ISO/IEC FCD 24713-2, Biometric Profiles for Interoperability and Dat

20、a Interchange Part 2: Physical Access Control for Employees at Airports Source: Project Editor Project Number: 37.24713.2 Document Status: As per WG 4 Wellington resolution 4.3, this document is circulated to SC 37 National Bodies for FCD ballot. In particular, National Bodies are requested to submi

21、t comments/contributions on: Text for reference to 19794-9, Vascular Image Data, along with corresponding tables for Annex A Text for reference to 19794-10, Hand Geometry Silhouette Data, along with corresponding tables for Annex A These additional modalities could be included in the standard if the

22、 properly verified information for tables in Annex A is provided. If such information is not provided, these modalities will not be included in this version of the standard. Recipients of this document are invited to submit notification of any relevant patent rights of which they are aware and to pr

23、ovide supporting documentation. Please submit your vote via the online balloting system. Given the short time between this meeting and the June 2007 meeting in Berlin, the results of the FCD ballot will be considered at a Ballot Resolution Meeting to be scheduled In September 2007. In preparation fo

24、r review at BRM meeting of any ballot comments, the Project Editor is instructed to prepare, by 29 July 2007, a summary of comments document, including a proposed Editors disposition of each comment. This Editors document will serve as the basis for discussion at the BRM. Action ID: LB Due Date: 200

25、7-06-29 No. of Pages: 59 Licensed Copy: London South Bank University, London South Bank University, Sat Mar 17 03:57:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI ISO/IEC FCD 24713-2 Date: 2007-02-28 Reference number: ISO/IEC JTC 1/SC 37 N 1997 Supersedes document THIS DOCUMENT IS STILL UNDER STUDY

26、AND SUBJECT TO CHANGE. IT SHOULD NOT BE USED FOR REFERENCE PURPOSES. ISO/IEC JTC 1/SC 37 Biometrics Secretariat: USA (ANSI) Circulated to P- and O-members, and to technical committees and organizations in liaison for: - discussion at - comment by - voting by (P-members only) 2007-06-29 Please return

27、 all votes and comments via the online balloting system. ISO/IEC JTC 1/SC 37 Title: Text of ISO/IEC FCD 24713-2, Biometric Profiles for Interoperability and Data Interchange Part 2: Physical Access Control for Employees at Airports Project: 1.37.24713.2 Introductory note: As per WG 4 Wellington reso

28、lution 4.3, this document is circulated to SC 37 National Bodies for FCD ballot. Recipients of this document are invited to submit notification of any relevant patent rights of which they are aware and to provide supporting documentation. Licensed Copy: London South Bank University, London South Ban

29、k University, Sat Mar 17 03:57:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI i ISO/IEC JTC1 SC37 N 1997 DATE: 2007-02-28 ISO/IEC 1st FCD 24713-2 ISO/IEC JTC1/SC37/WG4 Secretariat: ANSI INFORMATION TECHNOLOGY BIOMETRIC PROFILES FOR INTEROPERABILITY AND DATA INTERCHANGE PHYSICAL ACCESS CONTROL FOR EMP

30、LOYEES AT AIRPORTS Warning This document is not an ISO International Standard. It is distributed for review and comment. It is subject to change without notice and may not be referred to as an International Standard. Recipients of this draft are invited to submit, with their comments, notification o

31、f any relevant patent rights of which they are aware and to provide supporting documentation. Licensed Copy: London South Bank University, London South Bank University, Sat Mar 17 03:57:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI ii Copyright notice To be provided at appropriate time Licensed Copy

32、: London South Bank University, London South Bank University, Sat Mar 17 03:57:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI iii Contents Page 1 Scope 7 2 Conformance. 7 3 Normative references . 7 4 Terms and definitions. 8 5 Environment12 5.1 Employees in the targeted enviornment.12 5.2 Architectur

33、e.13 5.3 Token13 5.4 Token management system.13 5.5 Command and control system 14 5.6 Command and control administration system 14 5.7 Infrastructure system .14 6 Process 14 6.1 General.15 6.2 Registration.15 6.2.1 Proofing .15 6.2.2 Biometric collection15 6.3 Issuance.15 6.4 Activation to a local a

34、ccess control system 16 6.5 Usage16 6.6 Proofing .17 7 Security Considerations.17 Annex A.19 A.1 General.19 A.2 Relationship between RL and corresponding ICS proformas19 A.3 Profile Specific Implementation Conformance Statement20 A.4 Instruction for completing the ICS proforma.20 A.4.2 Additional In

35、formation20 A.4.3 Exception Information20 A.5 ICS proforma .22 A.6 Interchange Formats.23 A.6.1 Finger Image Data (ISO/IEC 19794-4:2005).23 A.6.2 Finger Minutia Data (ISO/IEC 19794-2:2004) 24 A.6.3 Finger Pattern Spectral Data (ISO/IEC 19794-3:2006) .28 A.6.4 Face Image Data (ISO/IEC19794-5:2005).30

36、 A.6.5 Iris Image Data (ISO/IEC 19794-6:2005) 33 A.6.6 Signature/Sign Time Series Data (ISO/IEC FDIS 19794-7)x 34 A.6.7 Finger Pattern Skeletal Data (ISO/IEC ISO/IEC 19794-8:2006)36 A.6.8 Vascular Image Data (ISO/IEC FDIS 19794-9).40 A.6.9 Hand Geometry Silhouette Data (ISO/IEC FDIS 19794-10)42 A.7

37、Technical Interface Standards.43 A.7.1 BioAPI (ISO/IEC ISO/IEC 19784-1:2006)43 A.7.2 CBEFF (ISO/IEC ISO/IEC 19785-1:2006.49 Annex B.51 Licensed Copy: London South Bank University, London South Bank University, Sat Mar 17 03:57:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI iv Annex C.52 Annex D.55 D.

38、1 Approaches55 D.2 Profiles .55 Licensed Copy: London South Bank University, London South Bank University, Sat Mar 17 03:57:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI v Foreword ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) form t

39、he specialized system for worldwide standardization. National bodies that are members of ISO or IEC participate in the development of International Standards through technical committees established by the respective organization to deal with particular fields of technical activity. ISO and IEC tech

40、nical committees collaborate in fields of mutual interest. Other international organizations, governmental and non- governmental, in liaison with ISO and IEC, also take part in the work. In the field of information technology, ISO and IEC have established a joint technical committee, ISO/IEC JTC 1.

41、International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of the joint technical committee is to prepare International Standards. Draft International Standards adopted by the joint technical committee are circulated to national bodies for

42、 voting. Publication as an International Standard requires approval by at least 75 % of the national bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO and IEC shall not be held responsible for identifying

43、any or all such patent rights. ISO/IEC 24713 was prepared by Technical Committee ISO/TC JTC1, Information Technology, Subcommittee SC 37, Biometrics. ISO/IEC 24713 consists of the following parts, under the general title Biometric Profiles for Interoperability and Data Interchange Part 1: Biometric

44、Reference Architecture; Part 2: Physical Access Control for Employees at Airports; Part 3: Biometrics-Based Verification and Identification of Seafarers. Licensed Copy: London South Bank University, London South Bank University, Sat Mar 17 03:57:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 6 Introd

45、uction This standard is one of a family of international standards being developed by ISO/IEC JTC 1/SC 37 that support interoperability and data interchange among biometrics applications and systems. This family of standards specifies requirements that solve the complexities of applying biometrics t

46、o a wide variety of personal recognition applications, whether such applications operate in an open systems environment or consist of a single, closed system. Biometric data interchange format standards and biometric interface standards are both necessary to achieve full data interchange and interop

47、erability for biometric recognition in an open systems environment. The ISO/IEC JTC 1/SC 37 biometric standards family includes a layered set of standards consisting of biometric data interchange formats and biometric interfaces, as well as biometric profiles that describe the use of these standards

48、 in specific application areas. The biometric data interchange format standards specify biometric data interchange records for different biometric modalities. Parties that agree in advance to exchange biometric data interchange records as specified in a subset of the ISO/IEC JTC 1/SC 37 biometric da

49、ta interchange format standards should be able to perform biometric recognition with each others data. Parties should also be able to perform biometric recognition even without advance agreement on the specific biometric data interchange format standards to be used, provided they have built their systems on the layered ISO/IEC JTC 1/SC 37 family of biometric standards. The biometric interface standards include the Common Bi