07-30174053-DC.pdf

上传人:小小飞 文档编号:3726341 上传时间:2019-09-22 格式:PDF 页数:13 大小:70.39KB
返回 下载 相关 举报
07-30174053-DC.pdf_第1页
第1页 / 共13页
07-30174053-DC.pdf_第2页
第2页 / 共13页
07-30174053-DC.pdf_第3页
第3页 / 共13页
07-30174053-DC.pdf_第4页
第4页 / 共13页
07-30174053-DC.pdf_第5页
第5页 / 共13页
亲,该文档总共13页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《07-30174053-DC.pdf》由会员分享,可在线阅读,更多相关《07-30174053-DC.pdf(13页珍藏版)》请在三一文库上搜索。

1、a Date: 20 November 2007 Origin: European Latest date for receipt of comments: 29 February 2008 Project no.: 2007/03075 Responsible committee: EPL/108 Safety of electronic equipment within the field of audio/video, information technology and communication technology Interested committees: Title: Dra

2、ft BS EN 41003 Particular safety requirements for equipment to be connected to telecommunication networks and/or a cable distribution system Supersession information: If this document is published as a standard, the UK implementation of it will supersede BSEN41003 : 1999 and partially supersede. NON

3、E If you are aware of a current national standard which may be affected, please notify the secretary (contact details below). WARNING: THIS IS A DRAFT AND MUST NOT BE REGARDED OR USED AS A BRITISH STANDARD. THIS DRAFT IS NOT CURRENT BEYOND 29 February 2008. This draft is issued to allow comments fro

4、m interested parties; all comments will be given consideration prior to publication. No acknowledgement will normally be sent. See overleaf for information on commenting. No copying is allowed, in any form, without prior written permission from BSI except as permitted under the Copyright, Designs an

5、d Patent Act 1988 or for circulation within a nominating organization for briefing purposes. Electronic circulation is limited to dissemination by e-mail within such an organization by committee members. Further copies of this draft may be purchased from BSI Customer Services, Tel: +44(0) 20 8996 90

6、01 or email ordersbsi-. British, International and foreign standards are also available from BSI Customer Services. Information on the co-operating organizations represented on the committees referenced above may be obtained from the responsible committee secretary. Cross-references The British Stan

7、dards which implement International or European publications referred to in this draft may be found via the British Standards Online Service on the BSI web site http:/www.bsi-. Direct tel: 020 8996 7288 Responsible Committee Secretary: Mr K Stiles (BSI) E-mail: keith.stilesbsi- Draft for Public Comm

8、ent Head Office 389 Chiswick High Road London W4 4AL Telephone: +44(0)20 8996 9000 Fax: +44(0)20 8996 7001 Form 36 Version 7.0 DPC: 07/30174053 DC Licensed Copy: London South Bank University, London South Bank University, Thu Dec 20 02:51:35 GMT+00:00 2007, Uncontrolled Copy, (c) BSI b Introduction

9、This draft standard is based on European discussions in which the UK took an active part. Your comments on this draft are welcome and will assist in the preparation of the consequent British Standard. If no comments are received to the contrary, then the UK will approve this draft and implement it a

10、s a British Standard. Comment is particularly welcome on national legislative or similar deviations that may be necessary. Even if this draft standard is not approved by the UK, if it receives the necessary support in Europe, the UK will be obliged to publish the official English Language text uncha

11、nged as a British Standard and to withdraw any conflicting standard. UK Vote Please indicate whether you consider the UK should submit a negative (with reasons) or positive vote on this draft. Submission The guidance given below is intended to ensure that all comments receive efficient and appropria

12、te attention by the responsible BSI committee. Annotated drafts are not acceptable and will be rejected. All comments must be submitted, preferably electronically, to the Responsible Committee Secretary at the address given on the front cover. Comments should be compatible with Version 6.0 or Versio

13、n 97 of Microsoft Word for Windows, if possible; otherwise comments in ASCII text format are acceptable. Any comments not submitted electronically should still adhere to these format requirements. All comments submitted should be presented as given in the example below. Further information on submit

14、ting comments and how to obtain a blank electronic version of a comment form are available from the BSI web site at: http:/www.bsi- Template for comments and secretariat observations Date: xx/xx/200x Document: ISO/DIS xxxxx 1 2 (3) 4 5 (6) (7) MB Clause No./ Subclause No./ Annex (e.g. 3.1) Paragraph

15、/ Figure/Table/ Note (e.g. Table 1) Type of com- ment Comment (justification for change) by the MB Proposed change by the MB Secretariat observations on each comment submitted 3.1 Definition 1 ed Definition is ambiguous and needs clarifying. Amend to read . so that the mains connector to which no co

16、nnection . 6.4 Paragraph 2 te The use of the UV photometer as an alternative cannot be supported as serious problems have been encountered in its use in the UK. Delete reference to UV photometer. Microsoft and MS-DOS are registered trademarks, and Windows is a trademark of Microsoft Corporation. Lic

17、ensed Copy: London South Bank University, London South Bank University, Thu Dec 20 02:51:35 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Draft for vote FINAL DRAFT EUROPEAN STANDARD prEN 41003 NORME EUROPENNE EUROPISCHE NORM November 2007 CENELEC European Committee for Electrotechnical Standardization

18、 Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Project: 15235 Ref. No. prEN 410

19、03:2007 E ICS 33.040.00 Will supersede EN 41003:1998 English version Particular safety requirements for equipment to be connected to telecommunication networks and/or a cable distribution system Rgles particulires de scurit pour les matriels de scurit destins tre relis aux reseaux de tlcommunication

20、s et/ou aux systmes de distribution par cables Besondere Sicherheitsanforderungen an Gerte zum Anschluss an Telekommunikationsnetze und/oder Kabelverteilsysteme This draft European Standard is submitted to CENELEC members for Unique Acceptance Procedure. Deadline for CENELEC: 2008-04-18. It has been

21、 drawn up by CLC/TC 108X. If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. This draft European Standard w

22、as established by CENELEC in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members

23、 are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia,

24、 Spain, Sweden, Switzerland and the United Kingdom. Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without notice and shall not be referred to as a European Standard. Licensed Copy: London South Bank University, London South Ban

25、k University, Thu Dec 20 02:51:35 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Draft for vote prEN 41003:2007 2 Foreword This draft European Standard was prepared by the Technical Committee CENELEC TC 108X, Safety of electronic equipment within the fields of audio/video, information technology and com

26、munication technology. It is submitted to the Unique Acceptance Procedure. This European Standard will supersede EN 41003:1998. The following dates are proposed: latest date by which the existence of the EN has to be announced at national level (doa) dor + 6 months latest date by which the EN has to

27、 be implemented at national level by publication of an identical national standard or by endorsement (dop) dor + 12 months latest date by which the national standards conflicting with the EN have to be withdrawn (dow) dor + 36 months (to be confirmed or modified when voting) The first edition of thi

28、s European Standard was prepared by CENELEC TC 74X, in close cooperation with a number of international organizations, e.g. IEC, ECMA, CEPT, CCITT, ETSI. In 1993 TC 74X was disbanded and responsibility for this European Standard passed to the Technical Committee CENELEC TC 74, Safety and energy effi

29、ciency of information technology equipment. CENELEC TC 74 was disbanded by D112/112 in 2002 and merged with CENELEC TC 92 into new CENELEC TC 108, which was renumbered CENELEC TC 108X by 130 BT. At that time, a standard was needed for uniform application by network operators in Europe when approving

30、 subscribers equipment for attachment to their networks, and for purchasing purposes by network operators. In February 1986 the CENELEC Technical Board formed a working group Telecom Safety which became CENELEC/TC 74X in early 1987. IEC TC 74 established WG7 to amend IEC 60950 for a similar purpose.

31、 ENV 41003 was ratified by the CENELEC Technical Board in March 1988 and subsequently amended and converted into this EN 41003 which was ratified in September 1990. In June 1992 the CENELEC Technical Board approved the reprint of EN 41003, which was technically unchanged from EN 41003:1991 and refer

32、s to EN 60950:1992 wherever possible. The edition of EN 41003:1996 was deemed necessary following the publication of EN 60950:1992/A3:1995 to reflect further convergence of the two standards. The edition of EN 41003:1998 was deemed necessary following the publication of EN 60950:1992/A4:1997, to ref

33、lect further convergence of the two standards. This edition of EN 41003 was deemed necessary following the publication of EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements (IEC 60950-1:2005, modified), to reflect further convergence of the two standards. _ Licensed

34、 Copy: London South Bank University, London South Bank University, Thu Dec 20 02:51:35 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Draft for vote 3 prEN 41003:2007 Contents Introduction 4 1 Scope. 5 2 Normative references 5 3 Definitions . 6 4 Safety requirements and compliance criteria 6 4.1 Interco

35、nnection of equipment General requirements. 6 4.2 TNV circuits. 6 4.3 Protection against contact with TNV circuits. 7 4.4 Protection of telecommunication network and/or cable distribution network service persons, and users of other equipment connected to the network, from hazards in the equipment 7

36、4.5 Protection of equipment users from overvoltages on telecommunication networks and/or cable distribution systems 7 4.6 Protection of the telecommunication wiring system from overheating. 7 Annex A (informative) Relevant safety standards for the application of this European Standard 8 Annex B (inf

37、ormative) Telecommunication network voltages and signals. 9 Bibliography11 Figure Figure B.1 Current limit curves .16 Licensed Copy: London South Bank University, London South Bank University, Thu Dec 20 02:51:35 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Draft for vote prEN 41003:2007 4 Introductio

38、n This European Standard is needed for products intended to be connected to a telecommunication network and/or a cable distribution system not covered by the scope of EN 60950-1. It is to be used in conjunction with other product safety standards; examples of which are listed in Annex A. Upper level

39、s for telecommunication/cable distribution system signals have been defined. They include also telephone ringing signals which have been defined taking into account voltages commonly used in the different networks. The electrical hazard criteria have been chosen to accord with the IEC TS 60479 serie

40、s. Test levels used for the equipment take account of the possibility that overvoltages may occur on telecommunication and cable distribution networks. Special consideration has been given to equipment parts expected to be held or touched during normal use, e.g. telephone handsets. It is recognised

41、that in high overvoltages risk areas, requirements of this European Standard may not be sufficient; additional protective devices, not covered by this European Standard, may be installed in the communication networks to better meet extreme conditions. For the adoption of this European Standard, the

42、relevant special national conditions and A-deviations apply that are listed in Annexes ZB and ZC of EN 60950-1. Licensed Copy: London South Bank University, London South Bank University, Thu Dec 20 02:51:35 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Draft for vote 5 prEN 41003:2007 1 Scope This Euro

43、pean Standard applies to equipment designed and intended to be connected as a terminal to a TELECOMMUNICATIONS NETWORK and/or a CABLE DISTRIBUTION SYSTEM termination. It does not apply to equipment covered by EN 60950-1. This European Standard specifies the safety requirements of the interface to th

44、e telecommunication network and/or the cable distributions system only and it does not specify any other safety requirements. It applies regardless of ownership or responsibility for installation or maintenance of the equipment, and regardless of the source of power. This European Standard, in accor

45、dance with the principles of safety given in the introduction of EN 60950-1, covers the requirements and compliance criteria under three headings. Protection of equipment users from hazards in the equipment. The user is considered to be protected from hazards in the equipment if the equipment compli

46、es with a relevant safety standard, for example one of those listed in Annex A, but compliance with those standards is not part of this European Standard. Protection of SERVICE PERSONNEL working on a TELECOMMUNICATION NETWORK and/or a CABLE DISTRIBUTION SYSTEM and other users of a TELECOMMUNICATION

47、NETWORK and/or a CABLE DISTRIBUTION SYSTEM, from hazardous conditions on a TELECOMMUNICATION NETWORK and/or a CABLE DISTRIBUTION SYSTEM resulting from the connection of the equipment. Protection of equipment users from voltages on a TELECOMMUNICATION NETWORK and/or a CABLE DISTRIBUTION SYSTEM. Requi

48、rements additional to those specified in this European Standard may be necessary for equipment intended for operation while exposed, for example, to extremes of temperature, to excessive dust, moisture, or vibration, to flammable gases, to corrosive or explosive atmospheres, electromedical applicati

49、ons with physical connections to the patient. The requirements for the following items are not covered by this European Standard: functional reliability of equipment; communication facilities with remote supply using hazardous voltage; protection of equipment, TELECOMMUNICATION NETWORKS and/or CABLE DISTRIBUTION SYSTEMS from damage. 2 Normative references The following referenced documents are indisp

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1