1、BRITISH STANDARD BS 1054:1975 Specification for Engineers comparators for external measurement UDC 621.753.3:531.713 Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 24 06:00:17 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 1054:1975 This British Standard, having been approved by the Mechanical E

2、ngineering Industry Standards Committee, was published under the authority of the Executive Board on 30 June 1975 BSI 06-1999 First published July 1942 First revision September 1954 Second revision 30 June 1975. The following BSI references relate to the work on this standard: Committee reference ME

3、E/59 Draft for comment 73/33653 DC ISBN 0 580 08804 9 Co-operating organizations The Mechanical Engineering Industry Standards Committee, under whose supervision this British Standard was prepared, consists of representatives from the following Government departments and professional and industrial

4、organizations: Associated Offices Technical CommitteeDepartment of Trade Association of Consulting EngineersElectricity Supply Industry in England and Association of Hydraulic Equipment Wales Manufacturers Ltd.Engineering Equipment Users Association Association of Mining, Electrical andFederation of

5、 Manufacturers of Construction Mechanical EngineersEquipment and Cranes British Compressed Air SocietyInstitution of Gas Engineers British Electrical and Allied ManufacturersInstitution of Heating and Ventilating AssociationEngineers British Gas CorporationInstitution of Mechanical Engineers British

6、 Gear Manufacturers AssociationInstitution of Plant Engineers British Internal Combustion EngineInstitution of Production Engineers* Manufacturers AssociationLondon Transport Executive British Mechanical Engineering ConfederationMachine Tool Trades Association British Pump Manufacturers AssociationM

7、inistry of Defence* British Steel CorporationNational Coal Board British Steel IndustryProcess Plant Association Crown Agents for Oversea Governments andRailway Industry Association of Great Britain AdministrationsRoyal Institute of British Architects Department of Employment (HM FactorySociety of M

8、otor Manufacturers and Inspectorate)Traders Ltd. Department of the EnvironmentTelecommunication Engineering and Department of IndustryManufacturing Association Department of Industry National Engineering Laboratory The Government department and scientific and industrial organization marked with an a

9、sterisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of this British Standard: Department of Industry National PhysicalGauge and Toolmakers Association LaboratoryJoint Equipment Standardization Committee Department of Price

10、s and Consumer Protection British Calibration Services Amendments issued since publication Amd. No.Date of issueComments Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 24 06:00:17 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 1054:1975 BSI 06-1999i Contents Page Co-operating organizationsInside

11、 front cover Forewordii 1Scope1 2Definitions1 3Design features1 4Work table1 5Measuring tip1 6Operating force2 7Pointer2 8Scale2 9Performance3 10Marking3 Figure 1 Deviation from flatness1 Figure 2 Scale2 Table 1 Tolerances on consistency of reading3 Licensed Copy: sheffieldun sheffieldun, na, Fri No

12、v 24 06:00:17 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 1054:1975 ii BSI 06-1999 Foreword This British Standard is one of the series of standards for engineers precision measuring equipment for which metric versions are now being issued. It was first published as BS 1054 in 1942 and revised in 1

13、954. As in the case of earlier editions, this standard is concerned mainly with the accuracy of performance of comparators and touches on features of design only where these are likely to have a direct effect on the accuracy. A British Standard does not purport to include all the necessary provision

14、s of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 3 and a b

15、ack cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 24 06:00:17 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 1054:1975 BS

16、I 06-19991 1 Scope This British Standard specifies requirements for comparators having magnification factors of 250 and over. The type of comparator to which the requirements are primarily intended to apply is an instrument comprising a rigid stand supporting a measuring head over a work table. The

17、measuring head is provided with a measuring tip whose movements are amplified and indicated on a scale in metric units. The means of amplification may be mechanical, electrical, electronic, optical, fluid or pneumatic. 2 Definitions For the purposes of this standard, the following definitions apply.

18、 2.1 deviation from flatness the minimum distance between two parallel planes which just envelop the measuring face (see Figure 1) NOTEIt may be necessary to control the maximum slope of the surface deviations with respect to the enclosing planes. 2.2 flatness tolerance the maximum permissible devia

19、tion from flatness 3 Design features The instrument shall be of rigid construction and first class workmanship throughout. Particular attention should be paid to the rigidity of the vertical post or bracket which carries the measuring head and to the method of supporting the work table. The distance

20、 between the measuring head and work table shall be adjustable to suit workpieces of different sizes within the stated capacity of the instrument. The base shall be of rigid construction and shall be provided with three feet. It should provide facilities for interchanging work tables. The measuring

21、head shall be provided with a coarse adjustment for the accommodation of work within the capacity of the instrument. This coarse adjustment shall be smooth in operation and be provided with means of preventing free falling movement of the measuring head in the unclamped position. Means shall also be

22、 provided for finely adjusting the relative position of the measuring head to the work table and for clamping this fine adjustment in such a way as to ensure that the setting is maintained within one tenth of a division of the scale. The mechanism within the measuring head shall be provided with eff

23、ective means of preventing damage to it in the event of the measuring tip being raised abnormally or suddenly released. 4 Work table The work table shall be made of steel or of an alternative material of comparable wearing properties, for example, of granite or of steel with tungsten carbide inserts

24、, with or without grooves. Steel work tables shall be hardened over the working surface to not less than HV850 (Rockwell C63) and, after hardening, shall be suitably heat treated to give stability. The surface of the work table shall be finished by lapping and shall be flat to within the following t

25、olerances. The tolerances specified for flatness shall apply to the full working surface when the work table is 75 mm in diameter or smaller and to any area 75 mm in diameter for larger work tables. Any deviation from flatness shall be such as to give a convex configuration (see Figure 1). The lower

26、 surface of the work table, where it is a working surface, shall be parallel to the upper surface to within 0.01 mm per 25 mm. 5 Measuring tip The measuring tip shall be of hardened steel having a hardness of not less than HV850 or shall be of an alternative material of comparable wearing properties

27、. The face of the measuring tip shall normally be rounded; a minimum radius of 8 mm is recommended. For comparators having a magnification factor of 600 or less:0.001 mm For comparators having a magnification factor of over 600 and up to 10 000:0.0005 mm For comparators having a magnification factor

28、 greater than 10 000:0.0003 mm Figure 1 Deviation from flatness Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 24 06:00:17 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 1054:1975 2 BSI 06-1999 If a flat face is fitted, means shall be provided whereby the user is able to adjust the face of the t

29、ip so that the required degree of parallelism can be obtained between the tip and the surface of the work table. The measuring tip may be provided with a raising device. 6 Operating force It is recommended that the force applied to the measuring tip to obtain zero reading on the instrument be of the

30、 order of 2 N to 2.5 N. If a measuring force substantially different from this is required, it shall be stated in the purchasers order. The operating force shall be substantially constant throughout the working range; the maximum force shall not be more than 50 % greater than the minimum for instrum

31、ents having magnification factors below 3 000 nor more than 25 % greater than the minimum for instruments having magnifications greater than 3 000. 7 Pointer In dial reading instruments, the pointer shall be rigidly attached to its spindle in such a manner as to ensure that there will be no relative

32、 movement between them when the measuring tip is subject to rapid acceleration or deceleration, as in the event of the measuring tip being suddenly released and its motion being arrested by a fixed stop. The pointer should be provided with a suitable damping device. The thickness of the pointer shou

33、ld be approximately the same as that of the scale marks. The design of the pointer and associated scale shall be such as to reduce to the lowest possible value any errors due to parallax. For instruments having pointers which pass over the scale, the pointer tips should overlap the scale marks by on

34、e fifth to one half of the length of the shortest scale marks. 8 Scale The scale shall normally be graduated in metric units. NOTEIf required by the purchaser, the scale may be graduated in metric and imperial units, in which case the metric units shall predominate. The scale shall consist of black

35、marks on a white ground or such other combination of contrasting colours as will show up with equal clarity so that it can be conveniently read under ordinary workshop lighting conditions. All scale marks shall have a clean sharp outline and be uniform in thickness. The recommended line thickness is

36、 0.2 mm to 0.3 mm. Both fifth and tenth scale intervals shall be indicated by a slightly longer mark. On single range scales, at least every tenth interval shall be numbered and the value of each scale interval shall be clearly marked within the scale area or be numbered at least every tenth interva

37、l and the half scale value shall be clearly marked at the plus and minus ends of the scale. NOTEFor illustrations of the terms “scale mark” and “scale interval”, see Figure 2. On multi-range scales, at least every tenth interval shall be numbered and the value of each scale interval shall be clearly

38、 marked within the scale area using a suitable code to identify scale and scale interval values. Fine subdivision of the scale is deprecated; it is recommended that no scale interval should be less than 1 mm. The zero scale mark should preferably be at the centre of the scale. Scales requiring the z

39、ero position to be other than in the centre position should be the subject of agreement between the purchaser and the manufacturer of the instrument. The relative movement of the pointer and scale should be such as to suggest to the observer the direction of movement of the measuring tip as the work

40、 is passed under it. For example, when the pointer moves over a fixed scale, an increase in the size of the work should be indicated by a movement of the pointer upwards on a vertical scale or to the right on a horizontal scale. If the scale is in the form of an arc above the centre of rotation of t

41、he pointer, a clockwise movement of the pointer should indicate an increase in the work size. Where the scale is in the form of an arc below the centre of rotation of the pointer, an anticlockwise movement of the pointer should indicate an increase in work size. The scale shall be boldly marked with

42、 plus and minus signs to indicate increases and decreases in the size of the measured work. Figure 2 Scale Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 24 06:00:17 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 1054:1975 BSI 06-19993 9 Performance 9.1 Consistency of reading. The consistency of

43、 reading of the comparator shall be examined by carrying out the following series of tests; the permissible errors are stated in Table 1 and are related to the magnification factor. 9.1.1 When the instrument is set to read on a workpiece and the measuring head is gently tapped, the maximum change in

44、 reading shall not exceed one half of the appropriate amount given in Table 1. 9.1.2 When a true cylinder is passed under the measuring tip from the front, from the rear, from the LH side, from the RH side, the maximum difference in reading found shall not exceed one half of the values in Table 1. 9

45、.1.3 The reading obtained when sliding a gauge block under the tip shall not differ from subsequent readings obtained by operating the lifting device by more than the appropriate amount given in Table 1. Table 1 Tolerances on consistency of reading 9.2 Accuracy of scale. The accuracy of the scale of

46、 the instrument shall be tested by taking readings on a suitable series of calibrated gauge blocks, first over the positive half of the scale and then over the negative half of the scale, checking at each major division. No reading shall have an error exceeding 1 % of the reading or the appropriate

47、amount () given in Table 1, whichever is greater. For example, in the case of a comparator having a magnification factor of 1 000, the maximum permissible error over the range 0 to 0.05 mm would be 0.000 5 and, beyond this range, 1 % of the reading. 10 Marking Each instrument shall be marked with th

48、e makers name or recognized trademark and with a serial number. Magnification factor of measuring head Tolerance on reading mm From250 up to and including300 0.002 0 Above300 up to and including400 0.001 5 Above400 up to and including600 0.001 0 Above600 up to and including1 000 0.000 8 Above1 000 u

49、p to and including2 000 0.000 5 Above2 000 up to and including5 000 0.000 3 Above5 000 up to and including 10 000 0.000 1 Above 10 0000.000 05 Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 24 06:00:17 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 1054:1975 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions Briti