资源描述

《ANSI-ASHRAE-90.1-2004-SI-ERTA-2007(0501).pdf》由会员分享,可在线阅读,更多相关《ANSI-ASHRAE-90.1-2004-SI-ERTA-2007(0501).pdf(6页珍藏版)》请在三一文库上搜索。

1、Page 1 of 6 2007 ASHRAE. All rights reserved. ERRATA SHEET FOR THE FIRST PRINTING OF ANSI/ASHRAE/IESNA STANDARD 90.1-2004 (SI edition) Energy Standard for Buildings Except Low-Rise Residential Buildings May 1, 2007 The corrections listed in this errata sheet apply to the first printing of ANSI/ASHRA

2、E/IESNA Standard 90.1-2004, SI edition, identified as “86248 PC 1/05”on the outside back cover of the standard. Shaded items have been added since the previously published errata sheet dated March 23, 2007 was distributed. More than one errata sheet may be required for a specific document. Please re

3、view the entire list on the ASHRAE website related to the applicable document and download all that apply. NOTICE: ASHRAE now has a list server for Standing Standards Project Committee 90.1 (SSPC 90.1). Interested parties can now subscribe and unsubscribe to the list server and be automatically noti

4、fied via e-mail when activities and information related to the Standard and the Users Manual is available. To sign up for the list server please visit Project Committee List Servers for Standard on the Technology / Standards section of the ASHRAE website at http:/www.ashrae.org/publications/detail/1

5、5620. Page(s) Erratum 15 Section 3.3 Abbreviations and Acronyms. Change CTI from “Cooling Tower Institute” to “Cooling Technology Institute”. 17 Section 5. Building Envelope. In the compliance path figure at the beginning of Section 5 correct the spelling of prescriptive so it reads “5.5 Prescriptiv

6、e Path”. 19 Table 5.5.3.1. Change the title of Table 5.5.3.1 as follows: (Note: Additions are shown in underline and deletions are shown in strikethrough.) Roof U-Factor Multipliers for Exception to 5.5.1.1 5.5.3.1 22 through 30 TABLES 5.5-1 through 5.5-8 Building Envelope Requirements. Add a footno

7、te to the bottom of Tables 5.5-1 through 5.5-8 as follows: “The following definitions apply: ci = continuous insulation (see Section 3.2), NR = no (insulation) requirement.” 24 TABLE 5.5-3 Building Envelope Requirements for Climate Zone 3 (A, B, C). In footnote “b” of Table 5.5-3 change “non-residen

8、tial” to “nonresidential”. 34 P.O. Box 73383, Houston, TX 77273-3383 118 Table B-3 International Climate Zones. Inadvertent omission of the climate zones for New Zealand. Insert the following climate zone numbers as published in Addendum “am” to 90.1-2001: New Zealand Auckland Airport 4 Christchurch

9、 4 Wellington 4 130 Normative Appendix D Climatic Data. At the top of the page delete the second sentence that reads “Table numbers corresponding to the envelope criteria tables in Normative Appendix B are also included.” 153 Table D-2 Canadian Climatic Data. The SI edition of Standard 90.1 incorrec

10、tly included I-P climatic data in Table D-2. See Table D-2 for changes (attached). Table changed to reflect SI units. (Note: Additions are shown in underline and deletions are shown in strikethrough.) 168 Table F-2 Addenda to ANSI/ASHRAE/IESNA Standard 90.1-2001, Approval Dates. In the third and fou

11、rth columns for Addenda q, t, u, y, z, aa, ab, ac, ae, ag, ah, ai, al, and am change the July 1, 2001 date to July 1, 2004 (14 places in each of the two columns). -,-,- Page 4 of 6 2007 ASHRAE. All rights reserved. Table 7.8 Performance Requirements for Water Heating Equipment Equipment Type Size Ca

12、tegory (Input) Subcategory or Rating Condition Performance Required a Test Procedureb 12 kW Resistance75.7 L 20 + 355.9 + 5.3 V SL, W ANSI Z21.10.3 Electric Water Heaters 22.98 kW 14.66 kW and 30.78 kW 61.55 kW 309.75 W/L and 61.55 kW 309.75 W/L and 37.85 78% Et (Q/800 + 110799 + 16.6 V ) SL, W ANSI

13、 Z21.10.3 Hot Water Supply Boilers, Gas and Oil 61.55 kW and 3663.8 kW 309.75 W/L and 37.85 80% Et Hot Water Supply Boilers, Gas 309.75 W/L and 37.85 80% Et (Q/800 + 110799 + 16.6 V ) SL, W Hot Water Supply Boilers, Oil 309.75 W/L and 37.85 78% Et (Q/800 + 110799 + 16.6 V ) SL,W ANSI Z21.10.3 Page 5

14、 of 6 2007 ASHRAE. All rights reserved. Pool Heaters Oil and Gas All 78% Et ASHRAE 146 Heat Pump Pool Heaters All 4.0 COP ASHRAE 146 Unfired Storage Tanks All R-2.2 (none) a Energy factor (EF) and thermal efficiency (Et) are minimum requirements, while standby loss (SL) is maximum W based on a 38.9C

15、 temperature difference between stored water and ambient requirements. In the EF equation, V is the rated volume in gallons liters. In the SL equation, V is the rated volume in gallons liters and Q is the nameplate input rate in W. b Section 12 contains a complete specification, including the year v

16、ersion, of the referenced test procedure. c Instantaneous water heaters with input rates below 58.62 W must comply with these requirements if the water heater is designed to heat water to temperatures 82.2C or higher. -,-,- Page 6 of 6 2007 ASHRAE. All rights reserved. Table D-2 Canadian Climatic Da

17、ta Cooling Design Temperature Heating Design Temperature Dry- Bulb Wet- Bulb Province Latitude Longitude Elev. (m) HDD18 CDD10 99.6% 1.0% 1.0% City Alberta (AB) Calgary International A 51.12 N114.02 W 3533 1076 9,885 5,492 1,167 648 -22 -30 80 27 59 15 Edmonton International A 53.30 N113.58 W 2345 714 11,023 6,124 1,069 594 -28.1 -33 78 26 63 17 Grande Prairie A 55.18 N118.88 W 2185 665 11,240 6,244 1,031 573 -32 -36 78 26 60 16 Lethbridge A 49.63 N112.80 W 3047 928 8,783 4,879 1,730 961 -22 -30 84 29 61 16 -,-,-