1、BRITISH STANDARD BS 9133:1973 Rules for the preparation of Detail specifications for Single turn low power rotary potentiometers of assessed quality Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9133:1973

2、BSI 02-2000 ISBN 0 580 34370 7 Foreword This British Standard, which has been prepared under the authority of the Telecommunication Industry Standards Committee gives the specific rules for the preparation of detail specifications for single turn low power rotary potentiometers of assessed quality a

3、nd should be read in conjunction with Section 2 of BS 9130 “Potentiometers of assessed quality: Generic data and methods of test”. It has been issued in the United Kingdom, where it is urgently required but if a similar procedure is adopted in other countries changes will be considered for the purpo

4、ses of harmonization. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages Th

5、is document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 5 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since pu

6、blication Amd. No.DateComments Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9133:1973 BSI 02-2000i Contents Page ForewordInside front cover 1Scope1 2Dimensions and outline drawings1 3Ratings and character

7、istics1 4Drying1 5Ordering information1 6Inspection Requirements1 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ii blank Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 0

8、2:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9133:1973 BSI 02-20001 1 Scope This British Standard prescribes those special rules for drafting, which in conjunction with the general rules contained in Section 2 of BS 9130, are required for the preparation of detail specifications for single

9、turn low power rotary potentiometers of assessed quality. 2 Dimensions and outline drawings 2.1 The spindle and bush dimensions shall preferably be chosen from BS 9130. 2.2 Where possible, gauging dimensions shall be indicated upon the outline drawing on the front cover of the detail specification a

10、nd shall normally comprise the following: 1) Depth from mounting face. 2) Diameter. 3) Fixing dimensions. 4) Location of terminations. 5) Spindle and bush dimensions. 2.3 The detail specification shall contain an appendix giving the drawing of the potentiometer with full detail dimensions, where it

11、is not feasible to give this information on the front cover. It shall also identify the normal mounting means. 3 Ratings and characteristics (see 1.1.12 and 2.1.5 of BS 9130) 3.1 The standard values of ratings and characteristics shall be selected in accordance with 1.1.12 of BS 9130, except that th

12、e values of rated dissipation shall be limited to 10 W and below. 3.2 A statement of derating or a derating curve shall be given and shall be as shown in 2.1.5.2 of BS 9130. 3.3 The preferred rating for rotary switches attached to potentiometers is 1 A, 250 V a.c., 40 Hz to 60 Hz. 4 Drying When dryi

13、ng is required, the detail specification shall call for Procedure I of 1.2.4.1 of BS 9130. 5 Ordering information The detail specification shall require that the information listed in 1.1.15 of BS 9130 shall be given when potentiometers are ordered to the specification. 6 Inspection Requirements (se

14、e 2.2 of BS 9130) 6.1 Where a subgroup contains more than one test, the tests shall be carried out in the order given in the schedule. 6.2 Samples submitted to tests which are marked as “(D)” shall not be accepted for release under BS 9000 (see 2.6.5 of BS 9000-1). 6.3 The schedule below shall be ap

15、plicable to each individual style in the full assessment class. InspectionBS 9130 reference and conditions of test Group ATo be applied on a sampling basis lot-by-lot, excepting subgroup A0 Subgroup A4 is not applicable Subgroup A0 Resistance a to c1.2.4.3.2 100 % inspection Subgroup A1 Visual inspe

16、ction Inspection level I, AQL 1.5 % 1.2.2 Subgroup A2Inspection level S-2, AQL 4.0 % Resistance a to b b to c 1.2.4.3.3 1.2.4.3.4 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9133:1973 2 BSI 02-2000 Inspe

17、ctionBS 9130 reference and conditions of test Subgroup A2 (continued) Continuity Rotational noise Switch contact resistance (where appropriate) Voltage proof 1.2.4.2 1.2.4.13 1.2.4.9 1.2.4.10 Method A or B to be specified The test shall be applied to potentiometers and, where applicable, switches Su

18、bgroup A5 CTR information1.1.11Attributes information for subgroup A2 without reference to the individual tests Group B Subgroup B1 Dimensions (gauging) Total mechanical rotation To be applied on a sampling basis lot-by-lot Subgroups B3 to B7 are not applicable Inspection level S-2, AQL 4.0 % 1.2.3.

19、1 1.2.3.3 Subgroup B2 (D)Inspection level S-2, AQL 4.0 % Robustness of terminations Measurement Visual examination Solderability Measurement Visual examination Mechanical endurance (Potentiometers) Final measurements Visual examination Resistance a to c Starting torque, including switch (when fitted

20、) Rotational noise Sealing 1.2.6.1 1.2.6.3.2 1.2.7.1 Tensile Bending Resistance a to c Method 1 or 2 No load 2 500 cycles at 10 17 cycles per min Method A or B to be specified Where a switch is fitted, the functional operation of the switch shall be checked by a suitable method Subgroup B8 CTR infor

21、mation1.1.11Attributes information for subgroup B1 without reference to the individual tests Group C Subgroup C1 Starting torque End-stop torque Thrust and pull Final measurements continuity Resistance a to b (Laws A and B) or Resistance b to c (Law C) Visual examination To be applied on a sampling

22、basis at three monthly intervals. Subgroup C5 is not applicable Sample size 13, Accept 1/Reject 2 1.2.5.1 1.2.5.3 1.2.5.5 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9133:1973 BSI 02-20003 InspectionBS 9

23、130 reference and conditions of test Subgroup C2 Minimum effective resistance and angle of ineffective rotation (where applicable) Resistance law Sample size 13, Accept 1/Reject 2 1.2.4.5 1.2.4.7 Subgroup C3 (D) (i) 7 specimens Sample size 13, Accept 2/Reject 3 Robustness of terminations Measurement

24、s Visual examination Resistance a to c Resistance to soldering heat Measurements Resistance a to c Resistance a to b Resistance b to c 1.2.6.1 1.2.6.3.3 Tensile Bending (ii) 6 specimens Change of temperature Bump Measurements Visual examination Resistance a to c Vibration Measurements Effective cont

25、inuity Visual examination Resistance a to c (iii) Specimens from (i) and (ii) combined Climatic sequence Final measurements Visual inspection Resistance a to c Insulation resistance Switch contact resistance Continuity Starting torque Voltage proof 1.2.6.4 1.2.6.6 1.2.6.5 1.2.6.8Procedure 1 of Test

26、Z/ABDM of BS 2011 Subgroup C4 (D)Sample size 13, Accept 1/Reject 2 Electrical endurance (at 70 C) Final measurements Visual examination Resistance a to c Insulation resistance Rotational noise 1.2.7.41 000 h duration Method A or B to be specified Licensed Copy: London South Bank University, London S

27、outh Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9133:1973 4 BSI 02-2000 InspectionBS 9130: reference and conditions of test Subgroup C6 CTR information1.1.11Attributes information shall be given for subgroups C1, C2, C3 and C4 without reference to the individu

28、al tests Measurements information shall be given for change in resistance in subgroup C4 Group D Subgroup D1 (D) To be applied on a sampling basis at three yearly intervals Sample size 13, Accept 1/1 Reject 2 Damp heat (steady state) Final measurements Isolation voltage Visual examination Resistance

29、 a to c Insulation resistance Starting torque Rotational noise Voltage proof After extended recovery (-/-/21 only) Insulation resistance 1.2.6.9 Method A or B to be specified Subgroup D2 (D)Sample size 13, Accept 1/Reject 2 Electrical endurance (at room temperature) Final measurements Visual examina

30、tion Resistance a to c Insulation resistance 1.2.7.31 000 h duration Subgroup D3 Temperature characteristic of resistance Sample size 13, Accept 1/Reject 2 1.2.4.12 Subgroup D4 Dimensions (detail) Sample size 13, Accept 1/Reject 2 1.2.3.2 Subgroup D5 (D)Sample size 13 (For CTR purposes only) Electri

31、cal endurance (at 70 C) 1.2.7.48 000 h duration Intermediate measurements at 168, 500, 1 000, 2 000 and 4 000 h Subgroup D6 (D)Sample size 13, Accept 2/Reject 3 Mechanical endurance Measurements Visual examination Resistance a to c Resistance a to b b to c Insulation resistance Starting torque Conti

32、nuity 1.2.7.125 000 cycles at 1017 cycles per min Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9133:1973 BSI 02-20005 InspectionBS 9130: reference and conditions of test Subgroup D6 (continued) Thrust/pul

33、l Voltage proof Rotational noise Sealing Mechanical Endurance of a switch (when fitted) 1.2.7.2 Method A or B to be specified Subgroup D7 CTR information1.1.11Attributes information shall be given for subgroups D1, D2, D3, D4 and D6 without reference to the individual tests Measurements information

34、shall be given for the change of resistance in subgroups D1, D5 and D6 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9133:1973 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI

35、 is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards should make

36、sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee respo

37、nsible, the identity of which can be found on the inside front cover. Tel: 020 8996 9000. Fax: 020 8996 7400. BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, inte

38、rnational and foreign standards publications should be addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise

39、 requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and s

40、ervices. Contact the Information Centre. Tel: 020 8996 7111. Fax: 020 8996 7048. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration.

41、 Tel: 020 8996 7002. Fax: 020 8996 7001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced,

42、 stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type o

43、r grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. If permission is granted, the terms may include royalty payments or a licensing agreement. Details and advice can be obtained from the Copyright Manager. Tel: 020 8996 7070. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 02:23:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI