1、BRITISH STANDARD BS 9210 N007-1:1976 Detail specification for radio frequency connectors (type SMB) Unsealed, soldered, captive contact, 50 7, snap-on couplings Full assessment level UDC 621.37/39:621.315.683 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:32

2、:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 BSI 04-2000 ISBN 0 580 09154 6 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard do

3、es not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 26 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated

4、 in the amendment table on the inside front cover. Amendments issued since publication Amd. No.DateComments Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 BSI 04-2000i Contents Page 1Physic

5、al characteristics2 2Ratings (including limiting conditions of use) and characteristics3 3Related documents4 4Additional information4 5Marking of the connectors and packages4 6Ordering information4 7Control drawings5 8Inspection requirements5 Appendix A Outline drawings17 Appendix B Piercings for me

6、tal panels printed wiring boards and overlap dimensions25 Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ii blank Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:32:56

7、GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 BSI 04-20001 ELECTRONIC COMPONENTS OF ASSESSED QUALITY: DETAIL SPECIFICATION Typical outlines, styles 06-03 and 07-02RADIO FREQUENCY CONNECTOR FULL ASSESSMENT LEVEL TYPE SMB UNSEALED, SOLDERED, CAPTIVE CONTACT 50 7 (SNAP-ON COUPLING) For

8、 other styles and dimensions see Appendix A. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 2 BSI 04-2000 1 Physical characteristics 1.1 1.2 Body finish Gold (Au), Cadmium (Cd), Bright Nick

9、el alloy (Ni-). NOTEGalvanic corrosion may occur when connectors with dissimilar finishes are mated. 1.3 Centre contact finish. Gold (Au). Connector style Description Mass (grams) max. Connector variant Cables BS 2316/(URM no.) 01-02Connector coupler, free, straight3.5matched 02-02Connector fixed, s

10、traight, 4-hole fixing, solder bucket 3.0AB110 AC95 AE109, 116 05-02Connector fixed, single hole mounting, solder bucket 1.5Unmatched 06-03Connector free, straight3.5ZZEquipment wire 07-02Connector fixed, straight, single hole mounting, cable outlet 3.1 08-03Connector free, right angle5.0 10-02Conne

11、ctor fixed, right angle, 4-hole fixing solder bucket 12-02Connector fixed, right angle, single hole mounting, solder bucket 5.0 13-02Connector fixed, straight, printed circuit board mounting 4.0 14-02Connector fixed, right angle, printed circuit board mounting 5.5 18-04Adaptor connector fixed, strai

12、ght, single hole mounting 3.0 18-05Adaptor connector fixed, straight, single hole mounting 5.0 98-12Cover, protective, for connector fixed and connector coupler, free 3.0 99-12Cover, protective, for connector free3.0 Licensed Copy: London South Bank University, London South Bank University, Fri Dec

13、08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 BSI 04-20003 2 Ratings (including limiting conditions of use) and characteristics Nominal characteristic impedance50 7 Matched variantsUnmatched variants Reflection coefficient (and v.s.w.r.) maximumUp to 4 GHz a) Straight ca

14、ble outlet styles0.19 (1.46)Not measured b) Right-angle styles and adaptors, straight0.25 (1.69) c) Solder-bucket stylesNot measured Capacitance (maximum) (solder-bucket styles only)5 pF R.F. shunt resistance (minimum) (solder-bucket styles only)1 M7 at 30 MHz Working voltage (d.c. or a.c. peak) Inn

15、er conductor to shell a) At sea level500 V b) At altitude of 20 km (44 mbara)100 V Proof voltage (d.c. or a.c. peak) a) At sea level1 500 V b) At altitude of 20 km (44 mbar)300 V Current rating (maximum)0.25 A Power ratingb a 1 mbar = 102N/m2= 100 Pa b As power is dependent on frequency and cable ty

16、pe, for information on power rating refer to the manufacturer. Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 4 BSI 04-2000 3 Related documents BS 2011, “Methods for the environmental testi

17、ng of electronic components and electronic equipment”. BS 2316, “Radio-frequency cables”. BS 6000, “Guide to the use of BS 6001. Sampling procedures and tables for inspection by attributes”. BS 6001, “Sampling procedures and tables for inspection by attributes”. BS 9000, “General requirements for el

18、ectronic components of assessed quality”. BS 9210, “Radio frequency connectors of assessed quality: generic data and methods of test”. 4 Additional information (Not for inspection purposes) For piercings for metal panels and overlap dimensions see Appendix B. 5 Marking of the connectors and packages

19、 The marking of the component and package shall be in accordance with 1.1.6 of BS 9210. Assembly and cable mounting instructions shall be included in every individual package of connector piece parts. 6 Ordering information In accordance with the requirements of 1.1.15 of BS 9210, orders for connect

20、ors and their accessories covered by this specification shall contain the following information. a) The number of this specification i.e. BS 9210 N007. b) Style as in 1.1, e.g. 0102. c) Variant as in 1.1, e.g. AB d) Climatic category, i.e. 55/155/21. e) Body finish, e.g. gold (Au). f) Any additional

21、 information, e.g. fixing hole details, any special marking, or packaging requirements. Example. BS 9210 N007/01 02/AB/55/155/21/Au. Before conditioning After conditioning Contact resistance, maximum5 m710 m7 Outer conductor continuity, maximum2 m75 m7 Insulation resistance, minimum5 G7500 M7 Vibrat

22、ion severity Frequency range10 Hz to 500 Hz Displacement0.75 mmCross over at Acceleration98 m/s2approximately 60 Hz Duration30 min Shock severityNot applicable Bump severity4 000 at 390 m/s2 Climatic category55/155/21 Resistance to test prod damageNot applicable Impact severity (free specimens only)

23、5 impacts at 1 m Engagement and separation forcesEngagement, 60 N maximum Separation, 60 N maximum 8 N minimum Licensed Copy: London South Bank University, London South Bank University, Fri Dec 08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 BSI 04-20005 7 Control drawings

24、 Control drawings, reference BS 9210 N007-2, are available from BSI. NOTENormally required by manufacturers and inspectorates only. 8 Inspection requirements 8.1 Unless otherwise stated in the table of tests the provisions of 8.2, 8.3 and 8.4 of this specification shall apply. 8.2 Contact resistance

25、 and outer conductor continuity for each mated pair shall be measured using the “light current” method specified in 1.2.4.3.3 1) of BS 9210. When testing the outer conductor continuity of panel mounted styles, where the connector shell is electrically connected to a mounting plate (see 1.2.1.1 of BS

26、 9210), the continuity test shall include a measurement between cable braid(s) and the mounting plate. The initial contact resistances for each mated pair of contacts and any outer conductor continuity shall not exceed 2 m7 respectively. Resistances after conditioning shall not exceed 10 m7 and 5 m7

27、 respectively. 8.3 Insulation resistance measurements between inner conductor and shell shall be made at 500 50 V d.c. 8.4 Voltage proof measurements shall be made at 1 500 100 V d.c. or peak a.c. (40 Hz to 60 Hz). There shall be no breakdown or flashover. 8.5 For tests in subgroups C3, C5, D3 (iii)

28、, and D3 (v), involving exposure to the upper temperature category, it is essential that cable having a compatible temperature capability shall be used. 8.6 Due to the nature of the accessories referred to in note 1 of this specification at the end of this table, certain tests are not possible, e.g.

29、 contact resistance tests are not applicable to protective covers styles 98-12 and 99-12 either before or after conditioning. 8.7 Samples submitted to tests which are marked as “(D)” shall not be accepted for release under BS 9000 (see 2.6.5 of BS 9000-1). 8.8 The tests or measurements prescribed in

30、 BS 9210 after environmental conditioning are omitted between the environmental conditionings where these form part of a sequence in accordance with 1.2.6 of BS 9210. The appropriate tests are included at the end of each test sequence. Inspection BS 9210:1971 reference and conditions of test Perform

31、ance requirements GROUP ATo be applied on a sampling basis lot-by-lot. Subgroups A2, A3 and A4 are not applicable Subgroup A0100 % inspection (see note 1 of this specification) Visual examination1.2.2 1)Either on assembled components or on contents of packages As in 1.2.2 1) of BS 9210 Subgroup A1In

32、spection level S-3, AQL 1.5 % (see note 1 of this specification) Visual examination1.2.2 2)Either on assembled components or on contents of packages As in 1.2.2 2) of BS 9210 Subgroup A5 CTR information1.1.11Attributes information for subgroup A1 GROUP BTo be applied on a sampling basis lot-by-lot.

33、Subgroups B3, B5, B6 and B7 are not applicable. (The specimens used for subgroups B1 and B2 may also be used for subgroup B4). Connectors shall be assembled in accordance with the instructions supplied by the manufacturer NOTESSee end of table. Licensed Copy: London South Bank University, London Sou

34、th Bank University, Fri Dec 08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 6 BSI 04-2000 Inspection BS 9210:1971 reference and conditions of test Performance requirements GROUP B (Contd) Subgroup B1Inspection level S-3, AQL 1 % Compatibility-mechanical (assurance) 1.2.5.9

35、 2)See note 1 of this specificationAs in 1.2.5.9 2) of BS 9210 Subgroup B2(D)Inspection level S-3, AQL 4 % Soldering1.2.6.1Soldering iron method Bit size 3 mm Iron size (b) Inner contact for all styles; also mounting spills for styles 13-02 and 14-02 There shall be no damage or loosening of parts In

36、sulation resistance1.2.4.6As in 8.3 of this specificationU 5 G7 Voltage proof1.2.4.7As in 8.4 of this specificationAs in 8.4 of this specification Subgroup B4(D)Inspection level S-3, AQL 4 % Engagement and separation 1.2.5.5See note 1 of this specificationAs in clause 2 of this specification Gauge r

37、etention force1.2.5.2See control drawings BS 9210 N007-2, for details of gauges As in 1.2.5.2 of BS 9210 Subgroup B8 CTR information1.1.11Attributes information for subgroups B1, B2, and B4 GROUP CApplied at three-monthly intervals except when group D tests are due. In addition the issue number of t

38、he manufacturers drawing list shall be checked against that in the qualification approval application or certificate. Specimens used for subgroup C1 may also be used for subgroups C3 and C5. Subgroups C2 and C4 are not applicable Subgroup C1Inspection level S-3, AQL 1 % Outline dimensions and mass 1

39、.2.3.1See note 1 of this specificationAs specified in 1.1 and Appendix A of this specification Subgroup C3(D)Inspection level S-3, AQL 4 % 8.5, 8.8, notes 1 and 2 of this specification apply to tests in this subgroup. Connectors shall be assembled as for group B. NOTESSee end of table. Licensed Copy

40、: London South Bank University, London South Bank University, Fri Dec 08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 BSI 04-20007 Inspection BS 9210:1971 reference and conditions of test Performance requirements Subgroup C3 (Contd) Test prod damageTest not to be applied R

41、apid change of temperature 1.2.6.9 55 C and + 155 C Damp heat, steady state1.2.6.8Severity 40 2 C for 4 days Polarizing voltage 60 5 V d.c. Inner conductor to be positive Working voltage 500 50 V d.c. or a.c. peak As in 1.2.6.8 of BS 9210 Final measurements Contact resistance1.2.4.3As in 8.2 of this

42、 specification (mated connectors not separated) (Not applicable to styles referred to in note 1 of this specification) As in 8.2 of this specification Outer conductor continuity1.2.4.4As in 8.2 of this specification (mated connectors not separated) (Not applicable to styles referred to in note 1 of

43、this specification) As in 8.2 of this specification Subgroup C3(D) Insulation resistance1.2.4.6As in 8.3 of this specification (Not applicable to styles referred to in note 1 of this specification) W 500 M7 Voltage proof1.2.4.7As in 8.4 of this specification Not applicable to styles referred to in n

44、ote 1 of this specification As in 8.4 of this specification Visual inspection1.2.2As in 1.2.2 of BS 9210 Engagement and separation 1.2.5.5Forces as in clause 2 of this specification Subgroup C5(D)Inspection level S-3, AQL 4 % 8.5, 8.8, notes 1 and 2 of this specification apply to tests in this subgr

45、oup. Connectors shall be assembled as for subgroup B Mechanical endurance1.2.7.150 operations at not more than 15/min followed by High temperature endurance 1.2.7.2Severity 155 5 C for 250 h with no electrical load Final measurements Insulation resistance1.2.4.6As in 8.3 of this specification Not ap

46、plicable to styles referred to in note 1 of this specification W 500 M7 Contact resistance1.2.4.3As in 8.2 of this specification Not applicable to styles referred to in note 1 of this specification As in 8.2 of this specification NOTESSee end of table. Licensed Copy: London South Bank University, Lo

47、ndon South Bank University, Fri Dec 08 04:32:56 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS 9210 N007-1:1976 8 BSI 04-2000 Inspection BS 9210:1971 reference and conditions of test Performance requirements Subgroup C5 (Contd) (D) Outer conductor continuity1.2.4.4As in 8.2 of this specification Not

48、applicable to styles referred to in note 1 of this specification As in 8.2 of this specification Voltage proof1.2.4.7As in 8.4 of this specification Not applicable to styles referred to in note 1 of this specification As in 8.4 of this specification Engagement and separation 1.2.5.5To be achievable

49、by hand in the normal manner Subgroup C6 CTR information1.1.11Attributes information for subgroups C3 and C5 GROUP D(D)D3 tests are to be performed at 3 year intervals. In addition the issue number of the manufacturers drawing list shall be checked against that in the qualification approval application or certificate. Subgroups D1 and D2 are not applicable Specimens D3 (i):3 sets of piece parts for each style and variant Accept on one failure The minimum number of specimens (mating pairs) required for each of the remaining subgroups is:

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1