1、BRITISH STANDARD BS EN 13836:2006 Gas fired central heating boilers Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1 000 kW The European Standard EN 13836:2006 has the status of a British Standard ICS 91.140.65 ? Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:26:

2、53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 13836:2006 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 September 2006 BSI 2006 ISBN 0 580 49300 8 National foreword This British Standard was published by BSI. It is the UK implementa

3、tion of EN 13836:2006. The UK participation in its preparation was entrusted to Technical Committee GSE/29, Gas-fired central heating boilers (domestic and non-domestic) and domestic gas-fired water heaters. A list of organizations represented on GSE/29 can be obtained on request to its secretary. T

4、his publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffi

5、eldun sheffieldun, na, Mon Oct 30 10:26:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13836 August 2006 ICS 91.140.65 English Version Gas fired central heating boilers - Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1 00

6、0 kW Chaudires de chauffage central utilisant les combustibles gazeux - Chaudires de type B dont le dbit calorifique nominal est suprieur 300 kW mais infrieur ou gal 1 000 kW Heizkessel fr gasfrmige Brennstoffe - Heizkessel des Typs B mit einer Nennwrmebelastung grer als 300 kW aber gleich oder klei

7、ner als 1 000 kW This European Standard was approved by CEN on 20 April 2006. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibl

8、iographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility o

9、f a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy,

10、Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050

11、Brussels 2006 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13836:2006: E Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:26:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13836:2006 (E) 2 Contents Page Foreword.6 1 Sc

12、ope7 2 Normative references8 3 Terms and definitions.9 3.1 Combustible gases .9 3.2 Constituent parts of the boiler.11 3.2.1 Gas supply.11 3.2.2 Combustion circuit12 3.2.3 Adjusting, control and safety devices 13 3.3 Operation of the boiler16 3.3.1 Gas rates16 3.3.2 Outputs.17 3.3.4 Gas combustion 1

13、7 3.3.5 Times18 3.3.10 Locking out19 4 Classification of boilers19 4.1 Gases and categories.19 4.2 Classification according to the mode of evacuation of the combustion products20 4.2.1 General.20 4.2.2 Type B.20 4.3 Classification according to operating conditions).21 4.3.1 Standard boiler21 4.3.2 L

14、ow-temperature boiler 21 4.3.3 Gas condensing boiler).21 4.4 Modular boiler21 5 Constructional requirements.21 5.1 General.21 5.2 Conversion to different gases21 5.3 Materials and method of construction22 5.3.1 General.22 5.3.2 Materials and thicknesses of walls or tubes under water pressure 22 5.3.

15、3 Thermal insulation 32 5.4 Design.33 5.4.1 General.33 5.4.2 Modular boilers33 5.5 Use and servicing33 5.6 Connections to the gas and water pipes34 5.6.1 General.34 5.6.2 Connections to the gas pipe34 5.6.3 Connections to the central heating circuit.34 5.7 Soundness.34 5.7.1 Soundness of the gas cir

16、cuit.34 5.7.2 Soundness of the combustion circuit.34 5.8 Supply of combustion air and the evacuation of the combustion products 35 5.8.1 Control dampers in the air or combustion products circuit.35 5.8.2 Fan35 5.8.3 Air proving .35 5.8.4 Gas/air ratio controls 35 5.8.5 Condensate discharge36 License

17、d Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:26:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13836:2006 (E) 3 5.9 Checking the state of operation 36 5.10 Drainage. 36 5.11 Electrical equipment. 37 5.12 Operational safety in the event of failure of the auxiliary energy 37 5.13 Adjusting, co

18、ntrol and safety devices 37 5.13.1 General. 37 5.13.2 Adjusters and range rating devices 37 5.13.3 Gas circuit 38 5.13.4 Gas pressure regulator. 39 5.13.5 Ignition devices. 40 5.13.6 Flame supervision systems. 40 5.13.7 Thermostats and water temperature limiting devices. 41 5.13.8 Device for monitor

19、ing the evacuation of combustion products 42 5.14 Burners 42 5.15 Pressure test points 42 5.16 Chemical composition of the condensate for low-temperature boilers 43 6 Operational requirements 43 6.1 General. 43 6.2 Soundness. 43 6.2.1 Soundness of the gas circuit. 43 6.2.2 Soundness of the combustio

20、n circuit and correct evacuation of the combustion products. 43 6.2.3 Soundness of the water circuit 43 6.3 Nominal, maximum and minimum heat inputs, and nominal output. 43 6.3.1 Nominal heat input or maximum and minimum heat inputs 43 6.3.2 Adjustment of the heat input by the downstream pressure. 4

21、4 6.3.3 Minimum ignition rate. 44 6.3.4 Nominal output 44 6.3.5 Gas pressure regulator. 44 6.4 Safety of operation 44 6.4.1 Limiting temperatures 44 6.4.2 lgnition Cross-lighting Flame stability 45 6.4.3 Pre-purge . 46 6.5 Adjusting, control and safety devices 47 6.5.1 General. 47 6.5.2 Ignition dev

22、ices. 47 6.5.3 Flame supervision devices 48 6.5.4 Ignition burner and ignition rates 50 6.5.5 Air proving. 50 6.5.6 Gas pressure switches. 51 6.5.7 Control thermostat and safety temperature limiter. 52 6.5.8 Device for monitoring the evacuation of combustion products 52 6.5.9 Condensate discharge bl

23、ockage. 53 6.6 Combustion . 53 6.6.1 Carbon monoxide 53 6.6.2 Other pollutants 53 6.7 Useful efficiencies. 54 6.7.1 Useful efficiency at the nominal heat input 54 6.7.2 Useful efficiency at part load. 54 6.8 Criteria for condensation in the flue. 55 6.9 Resistance of materials to pressure. 55 6.9.1

24、General. 55 6.9.2 Boilers of sheet steel or non-ferrous metals .55 6.9.3 Boilers of cast iron and cast materials. 55 6.10 Hydraulic resistance. 56 6.11 Combustion air and flue dampers. 56 6.12 Condensation in a standard boiler 56 Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:26:53 GMT+00

25、:00 2006, Uncontrolled Copy, (c) BSI EN 13836:2006 (E) 4 7 Test methods.56 7.1 General.56 7.1.1 Characteristics of the reference and limit gases.56 7.1.2 General test conditions 62 7.2 Soundness.66 7.2.1 Soundness of the gas circuit.66 7.2.2 Soundness of the combustion circuit and correct evacuation

26、 of the combustion products .66 7.2.3 Soundness of the water circuit66 7.3 Nominal, maximum and minimum heat inputs and nominal output67 7.3.1 The nominal heat input or the maximum and minimum heat inputs.67 7.3.2 Adjustment of the heat input by the downstream pressure.68 7.3.3 Minimum ignition rate

27、.68 7.3.4 Nominal output68 7.3.5 Gas regulator.68 7.4 Safety of operation69 7.4.1 Limiting temperatures.69 7.4.2 Ignition Cross-lighting Flame stability.69 7.4.3 Pre-purge71 7.5 Adjusting, control and safety devices 72 7.5.1 General.72 7.5.2 Ignition devices .72 7.5.3 Flame supervision device.73 7.5

28、.4 Ignition burner and ignition rates75 7.5.5 Air proving .75 7.5.6 Gas pressure switches.77 7.5.7 Control thermostat and safety temperature limiter .77 7.5.8 Device for monitoring the evacuation of combustion products 79 7.5.9 Condensate discharge blockage.79 7.6 Combustion80 7.6.1 Carbon monoxide8

29、0 7.6.2 Other pollutants.83 7.7 Useful efficiencies.86 7.7.1 Useful efficiency at the nominal heat input86 7.7.2 Useful efficiency at part load .87 7.8 Criteria for condensation in the flue .92 7.8.1 Determination of flue losses92 7.8.2 Minimum temperature of the combustion products93 7.9 Resistance

30、 of materials to pressure .93 7.9.1 General.93 7.9.2 Boilers of sheet steel or non-ferrous metals93 7.9.3 Boilers of cast iron and cast materials.93 7.10 Hydraulic resistance .94 7.11 Combustion air and flue dampers.94 7.12 Condensation in a standard boiler94 8 Marking and instructions95 8.1 Marking

31、 of the boiler.95 8.1.1 General.95 8.1.2 Data plate .95 8.1.3 Supplementary marking .96 8.1.4 Packaging.97 8.1.5 Warnings on the boiler and on the packaging.98 8.1.6 Other information98 8.2 Instructions98 8.2.1 Technical instructions for the installer.98 8.2.2 Use and maintenance instructions for th

32、e user.99 8.2.3 Conversion instructions.100 8.3 Presentation.100 Annex A (informative) National situations .112 Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:26:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13836:2006 (E) 5 Annex B (informative) Special national conditions. 118 Annex

33、C (informative) A-deviations 119 Annex D (informative) Practical method of calibrating the test rig to enable the heat loss Dp to be determined. 120 Annex E (informative) Main symbols and abbreviations used within this European Standard. 121 Annex F (informative) Compilations of test conditions used

34、 within this European Standard. 122 Annex G (informative) Valving. 125 Annex H (informative) Determination of the heat losses from the test rig of the indirect method and the contributions of the circulating pump of the test rig 128 Annex I (informative) Means of determining the ignition time at ful

35、l rate 129 Annex J (informative) Example of calculation of the weighting factors for a boiler with several rates 130 Annex K (informative) Calculation of conversions of NOx. 132 Annex L (informative) Use of test gases 133 Annex ZA (informative) Clauses of this European Standard addressing essential

36、requirements or provisions of EU Directives . 134 Bibliography . 138 Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:26:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13836:2006 (E) 6 Foreword This European Standard (EN 13836:2006) has been prepared by Technical Committee CEN/TC 109 “Cen

37、tral heating boilers using gaseous fuels”, the secretariat of which is held by NEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2007, and conflicting national standards shall be withd

38、rawn at the latest by February 2007. It was established to deal with aspects related to: safety; rational use of energy; fitness for purpose. Other types of boilers are dealt with in separate standards. This European Standard has been prepared under a mandate given to CEN by the European Commission

39、and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directives 90/396/EEC “Approximation of the laws of Member States concerning gas appliances” and 92/42/EEC “Efficiency requirements for new hot water boilers fired with liquid or

40、 gaseous fuels” see informative Annex ZA, which is an integral part of this European Standard. This standard covers only type testing. Boilers within the scope of this European Standard are typically installed in a room separated from living rooms and provided with appropriate ventilation directly t

41、o the outside. They need not be fitted with a combustion products discharge safety device but appropriate warnings on the packaging and in the instructions should clearly indicate the limit on the use of this type of boiler. It is impractical to use the full range of test gases to EN 437 for type te

42、sting since their availability, for inputs over 300 kW, may present problems for test houses and manufacturers. Informative Annex L gives guidance on the use of gases for tests in order to ensure conformity with EU Directive 90/396/EEC “Approximation of the laws of Member States concerning gas appli

43、ances.” According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, La

44、tvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:26:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13836:2006 (E) 7 1 Scope This European

45、Standard specifies the requirements and test methods concerning, in particular, the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric

46、 burners or fully premixed burners, and are hereafter referred to as “boilers”. This European Standard applies to boilers of type B, as listed in 4.2: that use one or more combustible gases of the three gas families at the pressures stated in Tables 16 and 17; that have a nominal heat input (on the

47、basis of net calorific value) exceeding 300 kW, but not exceeding 1 000 kW, including modular boilers; where the temperature of the heat transfer fluid does not exceed 105 C during normal operation; where the maximum operating pressure in the water circuit does not exceed 6 bar; that can give rise t

48、o condensation under certain circumstances; of the standard and low-temperature types. This European Standard applies to boilers designed for sealed water systems or for open water systems. This European Standard does not contain all the requirements necessary for boilers: intended to be installed i

49、n the open or in living rooms; permanently fitted with more than one flue outlet; where the combustion circuit is sealed with respect to the room where the boiler is installed; of the condensing type; intended to be connected to a common flue having mechanical extraction; fitted with a forced draught burner in accordance with EN 676 (see EN 303-7); producing hot water for domestic purposes. This standard only covers type testing. Matters related to quality