1、BRITISH STANDARD BS EN 13467:2001 Thermal insulating products for building equipment and industrial installations Determination of dimensions, squareness and linearity of preformed pipe insulation The European Standard EN 13467:2001 has the status of a British Standard ICS 91.120.10; 91.100.60 NO CO

2、PYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 13467:2001 This British Standard, having been prepared under the direction of the Engineering Sector Policy and Strategy

3、Committee, was published under the authority of the Standards Policy and Strategy Committee on 09 November 2001 BSI 09 November 2001 ISBN 0 580 38619 8 National foreword This British Standard is the official English language version of EN 13467:2001. This British Standard, together with BS EN 13468:

4、2001, BS EN 13469:2001, BS EN 13470:2001, BS EN 13471:2001 and BS EN 13472:2001, partially supersedes BS 2972:1989. The UK participation in its preparation was entrusted by Technical Committee RHE/9, Thermal insulating materials, to Subcommittee RHE/9/4, Nomenclature and specifications, which has th

5、e responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the

6、section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct applicat

7、ion. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related int

8、ernational and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 12, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document wa

9、s last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13467 September 2001 ICS 91.100.60 English version Thermal insulati

10、ng products for building equipment and industrial installations - Determination of dimensions, squareness and linearity of preformed pipe insulation Produits isolants thermiques pour lquipement du btiment et les installations industrielles - Dtermination des dimensions, de lquerrage et de la linarit

11、 des coquilles isolantes prformes Wrmedmmstoffe fr die Haustechnik und fr betriebstechnische Anlagen - Bestimmung der Mae, der Rechtwinkligkeit und der Linearitt von vorgeformten Rohrdmmstoffen This European Standard was approved by CEN on 18 August 2001. CEN members are bound to comply with the CEN

12、/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to an

13、y CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN

14、 members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMAL

15、ISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2001 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13467:2001 E Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:0

16、0 2006, Uncontrolled Copy, (c) BSI EN 13467:2001 (E) 2 Contents page Foreword.3 1Scope.4 2Normative references.4 3Terms and definitions.4 4Principle .5 5Apparatus.5 6Test specimens8 7Procedure 9 8Calculation and expression of results11 9Accuracy of measurement.12 10Test report12 Tables Table 1 ? Mea

17、surement and calculation of dimensions .11 Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13467:2001 (E) 3 Foreword This European Standard has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, th

18、e secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2002, and conflicting national standards shall be withdrawn at the latest by March 2002. This European

19、Standard is one of a series of standards which specify test methods for determining dimensions and properties of thermal insulating materials and products. It supports a series of product standards for thermal insulating materials and products which derive from the Council Directive of 21 December 1

20、988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products (Directive 89/106/EEC) through the consideration of the essential requirements. This European Standard has been prepared for products used to insulate building equipment

21、 and industrial installations, but it may also be applied to products used in other areas. No existing European Standard is superseded. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential req

22、uirements of EU Directive(s). According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxemb

23、ourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13467:2001 (E) 4 1Scope This European Standard specifies the equipment and procedures for determining

24、the dimensions, squareness and linearity of preformed pipe insulation, supplied in one piece, half sections or segments. It is applicable to thermal insulating products. 2Normative references This European Standard contains no normative references. 3Terms and definitions For the purpose of this Euro

25、pean Standard the following terms and definitions apply (see Figures 1 and 4). 3.1 circumference, C the circular length of the outer surface of the pipe insulation 3.2 outside diameter, Do the linear distance between two opposite points on the outside surface of the pipe insulation measured across t

26、he center 3.3 inside diameter, Di the linear distance between two opposite points on the inside surface of the pipe insulation measured across the center 3.4 length, l the linear dimension measured perpendicularly to the circumference of the pipe insulation 3.5 thickness, d the thickness of the insu

27、lation product measured perpendicularly between the outside and the inside surface of the pipe insulation 3.6 deviation from squareness, v the maximum distance between a product, at its end, from a line which just touches the product and which is perpendicular to its major axis (see Figure 4) 3.7 de

28、viation from linearity, L the maximum distance between a plane reference surface on which the test specimen rests and the outside surface of the pipe insulation Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13467:2001 (E) 5 Dimensions i

29、n millimetres Key 1Flat surface 2Locations for measurements (see 7.2.2.3) Figure 1 - Illustration of the definitions 4Principle Determination of the dimensions, squareness and linearity of a pipe insulation along or at a right angle to its major axis. 5Apparatus 5.1 For circumference, outside and in

30、side diameter and thickness 5.1.1 Metal tape graduated in millimetres for measuring circumference and diameter. Accuracy of reading: diameterat least 1 mm, circumferenceat least 3 mm. 5.1.2 Metal pipe for supporting the insulation with an outside diameter which ensures no deformation of the product

31、5.1.3 Rack for supporting the metal pipe (see Figure 2). 5.1.4 Thickness gauge, capable of applying a load of minimum (0,5 0,05) N to a load distributing plate, diameter 50 mm. The load shall be such that no deformation of the product occurs during measurement. Accuracy of reading at least 0,5 mm. 5

32、.1.5 Conical mandrel graduated in 0,5 mm intervals (see Figure 3). Accuracy of reading at least 0,5 mm. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13467:2001 (E) 6 5.1.6 Caliper Accuracy of reading at least 0,1 mm. 5.2 For length 5.2

33、.1 Metal tape graduated in millimetres. Accuracy of reading at least 1 mm. 5.3 For deviation from squareness 5.3.1 Metal square with limbs at least 500 mm long with a deviation from squareness of not more than 0,1 mm when measured at 500 mm from the corners (see Figure 4). 5.3.2 Metal tape graduated

34、 in millimetres. Accuracy of reading at least 1 mm. 5.4 For deviation from linearity 5.4.1 Flat surface on which the test specimen rests. 5.4.2 Metal tape graduated in millimetres. Accuracy of reading at least 1 mm. 5.4.3 Thickness gauge (wedgeshape), graduated in 0,5 mm (see Figure 5). Accuracy of

35、reading at least 0,5 mm. NOTE For all measured dimensions test equipment which provides the same result with at least the same accuracy may be used. Key 1 Thickness gauge 2 Test specimen 3 Metal pipe 4 Rack 5 Load distribution plate Figure 2 - Example of equipment for thickness measurement with thic

36、kness gauge Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13467:2001 (E) 7 Dimensions in millimetres Figure 3 - Example of conical mandrel Key 1Test specimen Figure 4 - Principle of measurement of deviation from squareness Dimensions in

37、 millimetres Figure 5 - Thickness gauge (wedgeshape) Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13467:2001 (E) 8 6Test specimens 6.1 Dimensions of test specimens The test specimens shall be, wherever possible, the full size pipe insu

38、lation product. The dimensions of the test specimens shall be measured including any surface skins, facings, and/or coatings on both the inner and the outer surfaces. NOTE For the measurement of circumference/outside diameter, inside diameter, and thickness the test specimen may be divided transvers

39、ely or longitudinally into several pieces; minimum dimension is 100 mm. Pipe insulation pieces (half sections or segments) which together form a complete pipe insulation layer, without visual deformation, shall be held in place by adhesive tape to facilitate measurement (see Figure 6). 2 half sectio

40、nssegments Figure 6 - Examples of pipe insulation pieces 6.2 Number of test specimens The number of test specimens shall be as specified in the relevant product standard. If the number is not specified, then at least three test specimens shall be used. NOTE In the absence of a product standard or an

41、y other European technical specification the number of test specimens may be agreed between parties. 6.3 Conditioning of test specimens The test specimens shall be stored for at least 6 h at (23 5) C. In case of dispute they shall be stored at (23 2) C and (50 5) % relative humidity for the time sta

42、ted in the relevant product standard. Licensed Copy: sheffieldun sheffieldun, na, Mon Oct 30 10:06:36 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 13467:2001 (E) 9 7Procedure 7.1 Test conditions The test shall be carried out at (23 5) C. In case of dispute it shall be carried out at (23 2) C and (5

43、0 5) % relative humidity. 7.2 Test procedure 7.2.1 General Determine the thickness, d, of the test specimen and its inside and outside diameter, Di and Do, from one of the following pairs of measurements: a) Outside circumference and inside diameter; b) Inside diameter and outside diameter; c) Insid

44、e diameter and thickness; d) Outside diameter and thickness; e) Outside circumference and thickness. Each set of measurements shall be performed at the same place on the pipe insulation. NOTE 1 The listed options are not equivalent. Only when thickness itself is measured, can an estimate of concentr

45、icity be obtained. NOTE 2 For pipe insulation with large inside diameter and small thickness attention should be paid to the required accuracy. Method c) or d) or e) should be used. Determine the length, l, deviation from squareness, v, and deviation from linearity, L, in accordance with 7.2.3, 7.2.

46、4 and 7.2.5. NOTE 3 Determination of deviation from squareness and deviation from linearity are not relevant for all materials and/or applications. 7.2.2 Circumference - outside diameter, inside diameter, wall thickness The appropriate apparatus, described in clause 5, shall be used for the measurem

47、ents below. During the measurement any longitudinal joints shall be kept close together. The pipe insulation shall not be visibly deformed due to the measuring process. Measure pipe insulation, with a length smaller than or equal to 600 mm, at two locations, either at the ends or 100 mm from each en

48、d. Measure pipe insulation, with a length larger than 600 mm, as above with one extra measurement for each additional 400 mm in length evenly distributed along the length, with a maximum of 5 measurements. NOTE The pipe insulation may be cut into smaller pieces at appropriate locations to facilitate

49、 measurement. The reading accuracy of the measurements shall correspond to the accuracy of the apparatus. 7.2.2.1 Circumference - outside diameter Measure the circumference, C, of the test specimen using a metal tape. Measure the outside diameter, Do, using either a metal tape or a caliper. Each measurement shall consist of two readings at right angles to the longitudinal axis of the test specimen at the selected locations. The readings of the outside diameter shall also be made at right angles to each other. Licens