1、BRITISH STANDARD Glass in building Insulating glass units Part 5: Evaluation of conformity ICS 81.040.20 ? BS EN 1279-5:2005 +A1:2008 Licensed CopyChinese University of Hong Kong, 13/06/2009 05:07, Uncontrolled Copy, (c) BSI BS EN 1279-5:2005+A1:2008 This British Standard was published under the aut

2、hority of the Standards Policy and Strategy Committee on 13 January 2006 BSI 2009 ISBN 978 0 580 61866 6 National foreword This British Standard is the UK implementation of EN 1279-5:2005+A1:2008. It supersedes BS EN 1279-5:2005 which is withdrawn. The UK participation in its preparation was entrust

3、ed by Technical Committee B/520, Glass and glazing in building, to Subcommittee B/520/2, Glass and glazing in building Insulated glass products. A list of organizations represented on this subcommittee can be obtained on request to its secretary. This publication does not purport to include all the

4、necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard can not confer immunity from legal obligations. Amendments/corrigenda issued since publication Date Comments 31 May 2009Implementation of CEN amendment A1:2008 The start and fini

5、sh of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated by . Licensed CopyChinese University of Hong Kong, 13/06/2009 05:07, Uncontrolled Copy

6、, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1279-5:2005+A1 November 2008 ICS 81.040.20 Supersedes EN 1279-5:2005 English Version Glass in building - Insulating glass units - Part 5: Evaluation of conformity Verre dans la construction - Vitrage isolant - Partie 5: Evaluation de la

7、conformit Glas im Bauwesen - Mehrscheiben-Isolierglas - Teil 5: Konformittsbewertung This European Standard was approved by CEN on 24 March 2005 and includes Amendment 1 approved by CEN on 2 October 2008. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the c

8、onditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in

9、three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies

10、of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPE

11、AN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1279-5:2005+A1:2008: E Licen

12、sed CopyChinese University of Hong Kong, 13/06/2009 05:07, Uncontrolled Copy, (c) BSI EN 1279-5:2005+A1:2008 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative references4 3 Terms and definitions .5 4 Requirements.6 4.1 Product description.6 4.2 Conformity with the definition of insulating glass un

13、its .6 4.3 Determination of the characteristics performances .6 4.4 Durability 10 4.5 Dangerous substances .10 5 Evaluation of conformity.10 5.1 General10 5.2 Initial type testing of the product (see 5.1, 2)11 5.3 Factory production control and inspection of samples in accordance with a prescribed t

14、est plan (5.1, 1) and 2) 13 5.4 Initial inspection of factory and of factory production control (5.1, 1), 2)14 5.5 Continuous surveillance and assessment of the factory production control (5.1, 1c).15 6 Marking and/or labelling .16 6.1 General16 6.2 Product marking 16 6.3 Product characteristics.16

15、6.4 “Characteristics/performance identification paper”16 Annex A (informative) Use of IGUs when subjected to UV and/or in SSG 17 Annex B (informative) Installation of the insulating glass units 18 Annex C (informative) Provisions for voluntary involvement of third party(ies)21 Annex ZA (informative)

16、 Clauses of this European Standard addressing the provisions of EU Construction Products Directive22 Bibliography31 BS EN 1279-5:2005+A1:2008 Licensed CopyChinese University of Hong Kong, 13/06/2009 05:07, Uncontrolled Copy, (c) BSI EN 1279-5:2005+A1:2008 (E) 3 Foreword This document (EN 1279-5:2005

17、+A1:2008) has been prepared by Technical Committee CEN/TC 129 “Glass in building“, the secretariat of which is held by NBN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2009, and conflictin

18、g national standards shall be withdrawn at the latest by May 2009. This document includes Amendment 1 approved by CEN on 2008-10-02. This document supersedes EN 1279-5:2005. The start and finish of text introduced or altered by amendment is indicated in the text by tags ! “. This document has been p

19、repared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. This Part of the European Stan

20、dard does not stand-alone, it is part of one standard with the general title Glass in building - Insulating glass units: Part 1: Generalities, dimensional tolerances and rules for the system description Part 2: Long term test method and requirements for moisture penetration Part 3: Long term test me

21、thod and requirements for gas leakage rate and for gas concentration tolerances Part 4: Methods of test for the physical attributes of edge seals Part 5: Evaluation of conformity Part 6: Factory production control and periodic tests This European Standard contains other aspects of importance of trad

22、e. This European Standard includes a Bibliography. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,

23、Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. BS EN 1279-5:2005+A1:2008 Licensed CopyChinese University of Hong Kong, 13/06/2009 05:07, Uncont

24、rolled Copy, (c) BSI EN 1279-5:2005+A1:2008 (E) 4 1 Scope This European Standard specifies requirements, the evaluation of conformity and the factory production control of insulating glass units for use in buildings. NOTE 1 For glass products with electrical wiring or connections for e.g. alarm or h

25、eating purposes, other directives, e.g. Low Voltage Directive, may apply. The main intended uses of the insulating glass units are installations in windows, doors, curtain walling, roofs and partitions where there exists protection against direct ultraviolet radiation at the edges. NOTE 2 In cases w

26、here there is no protection against direct ultra-violet radiation at the edges, such as structural sealant glazing systems, additional European technical specifications should be followed (e.g. !EN 15434“, !EN 13022-1“). NOTE 3 Units for which the intended use is only artistic and therefore no essen

27、tial requirement is required, are not subject to CE marking and are not part of this European Standard. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the

28、latest edition of the referenced document (including any amendments) applies. EN 356, Glass in building Security glazing Testing and classification of resistance against manual attack EN 410, Glass in building Determination of luminous and solar characteristics of glazing EN 572-1, Glass in building

29、 Basic soda lime silicate glass products - Part 1: Definitions and general physical and mechanical properties EN 673, Glass in building Determination of thermal transmittance (U value) Calculation method EN 674, Glass in building Determination of thermal transmittance (U value) Guarded hot plate met

30、hod EN 675, Glass in building Determination of thermal transmittance (U value) Heat flow meter method EN 1063, Glass in building Security glazing Testing and classification of resistance against bullet attack EN 1279-1:2004, Glass in building Insulating glass units Part 1: Generalities, dimensional

31、tolerances and rules for the system description EN 1279-2:2002, Glass in building Insulating glass units Part 2: Long term test method and requirements for moisture vapour penetration EN 1279-3:2002, Glass in building Insulating glass units Part 3: Long term test method and requirements for gas leak

32、age rate and for gas concentration tolerances EN 1279-4:2002, Glass in building Insulating glass units Part 4: Methods of test for the physical attributes of edge seals EN 1279-6:2002, Glass in building Insulating glass units Part 6: Factory production control and periodic tests EN 1748-1-1, Glass i

33、n building Special basic products Borosilicate glasses Part 1-1: Definition and general physical and mechanical properties EN 1748-2-1, !Glass in building - Special basic products - Glass ceramics - Part 2-1: Definitions and general physical and mechanical properties“ BS EN 1279-5:2005+A1:2008 Licen

34、sed CopyChinese University of Hong Kong, 13/06/2009 05:07, Uncontrolled Copy, (c) BSI EN 1279-5:2005+A1:2008 (E) 5 EN 1863-1, Glass in building Heat strengthened soda lime silicate glass Part 1: Definition and description EN 12150-1, Glass in building Thermally toughened soda lime silicate safety gl

35、ass Part 1: Definition and description EN 12337-1, Glass in building Chemically strengthened soda lime silicate glass Part 1: Definition and description EN 12600, Glass in building Pendulum test Impact test method and classification for flat glass EN 12758, Glass in building Glazing and airborne sou

36、nd insulation Product descriptions and determination of properties EN 12898, Glass in building Determination of the emissivity !EN 13022-1, Glass in building - Structural sealant glazing - Part 1: Glass products for structural sealant glazing systems for supported and unsupported monolithic and mult

37、iple glazing“ EN 13024-1, Glass in building Thermally toughened borosilicate safety glass Part 1: Definition and description EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using !Deleted text“ data from reaction to fire tests EN 13501-2, Fire cl

38、assification of construction products and building elements Part 2: Classification using !Deleted text“ data from fire resistance tests, excluding ventilation services !EN 13501-5“, Fire classification of construction products and building elements Part 5: Classification using data from external fir

39、e exposure to roof tests EN 13541, Glass in building Security glazing Testing and classification of resistance against explosion pressure EN 14178-1, Glass in building Basic alkaline earth silicate glass products Part 1: Float glass !EN 15434, Glass in building - Product standard for structural and/

40、or ultra-violet resistant sealant (for use with structural sealant glazing and/or insulating glass units with exposed seals)“ !deleted text“ 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 1279-1:2004, EN 1279-2:2002, EN 1279-3:2002, EN 1279-

41、4:2002 and EN 1279-6:2002 and the following apply. 3.1 initial type testing determination of the performance of a product (characteristic, durability), on the basis of either actual tests or other procedures (such as conventional, standardised, tabulated or general accepted values, standardised or r

42、ecognised calculation methods, test reports when made available,), in accordance with this European Standard that demonstrates compliance with this European Standard 3.2 test report document that covers the results of tests undertaken on a representative sample of the product from production or on a

43、 prototype design of the product BS EN 1279-5:2005+A1:2008 Licensed CopyChinese University of Hong Kong, 13/06/2009 05:07, Uncontrolled Copy, (c) BSI EN 1279-5:2005+A1:2008 (E) 6 3.3 product description document that details the relevant parameters, e.g. process conditions, structure, etc, for defin

44、ing a product that complies with the standard. It includes specific references to characteristics that are modified by the production process 3.4 significant change variation in performance beyond the permitted tolerance for the characteristic 4 Requirements 4.1 Product description For conformity pu

45、rposes the insulating glass unit manufacturer is responsible for the preparation and maintenance of the product description. This description shall describe the product and/or product families. Disclosure of the product description shall be at the discretion of the insulating glass unit manufacturer

46、 or his agent except in the case of regulatory requirements. The description shall contain at least a normative part. The description may also contain an informative part, when the manufacturer foresees further development of the product. The normative part of the description shall contain the follo

47、wing minimum information: a reference to EN 1279 Part 1, 2, 3, 4 and 6 and all other standards with which the manufacturer claims compliance; system description. The definition of product families shall be consistent with the normative part of the product description. The substitution of materials s

48、hall maintain the conformity with the product description. The substituting material can be added to the product family and also the product description when compliance has been demonstrated. 4.2 Conformity with the definition of insulating glass units Products shall conform to the definition and fu

49、lfil the requirements of insulating glass units as defined in EN 1279-1. 4.3 Determination of the characteristics performances 4.3.1 Characteristics of glass panes for use in insulating glass units For panes made of glass covered by European specifications generally accepted values, declared values, or calculated values of the characteristics listed in Table 1 shall be used. For panes made of gla

展开阅读全文