1、BRITISH STANDARD BS EN 13528-1:2002 Ambient air quality Diffusive samplers for the determination of concentrations of gases and vapours Requirements and test methods Part 1: General requirements The European Standard EN 13528-1:2002 has the status of a British Standard ICS 13.040.20 ? BS EN 13528-1:

2、2002 This British Standard, having been prepared under the direction of the Health and Environment Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 11 October 2002 BSI 11 October 2002 ISBN 0 580 40576 1 National foreword This B

3、ritish Standard is the official English language version of EN 13528-1:2002. The UK participation in its preparation was entrusted by Technical Committee EH/2, Air quality, to Subcommittee EH/2/3, Ambient atmospheres, which has the responsibility to: A list of organizations represented on this subco

4、mmittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the

5、 “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from le

6、gal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK.

7、Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 11 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments EUROPEAN STANDARD

8、 NORME EUROPENNE EUROPISCHE NORM EN 13528-1 September 2002 ICS 13.040.20 English version Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 1: General requirements Qualit de lair - Echantillonneurs par diffusio

9、n pour la dtermination des concentrations des gaz et des vapeurs - Prescriptions et mthodes dessai - Partie 1: Prescriptions gnrales Auenluftqualitt - Passivsammler zur Bestimmung der Konzentrationen von Gasen und Dmpfen - Anforderungen und Prfverfahren - Teil 1: Allgemeine Anforderungen This Europe

10、an Standard was approved by CEN on 21 July 2002. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concer

11、ning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own lan

12、guage and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sw

13、eden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2002 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Member

14、s. Ref. No. EN 13528-1:2002 E EN 13528-1:2002 (E) 2 Contents page Foreword3 Introduction.4 1Scope5 2Normative references5 3Terms and definitions .5 4Assessment regimes.7 5Performance requirements.7 5.1Unambiguity 7 5.2Selectivity8 5.3Data Quality Objectives.8 5.4Composite procedures8 5.5Environmenta

15、l conditions8 5.6Description of measuring procedure.8 5.7Dimension of result8 5.8Quality systems.8 6Test methods .8 7Test report9 Annex A (informative) Assessment of ambient air quality10 Bibliography11 EN 13528-1:2002 (E) 3 Foreword This document (EN 13528-1:2002) has been prepared by Technical Com

16、mittee CEN/TC 264 “Air Quality”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2003, and conflicting national standards shall be withdrawn at the l

17、atest by March 2003. This European Standard is a multi-part standard having the following parts: Part 1 (Ambient Air Quality) General requirements; Part 2 (Ambient Air Quality) Specific requirements and test methods; Part 3 (Ambient Air Quality) Guide to selection, use and maintenance. Annex A is in

18、formative. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Nether

19、lands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. EN 13528-1:2002 (E) 4 Introduction This European Standard specifies requirements and test methods for the determination of performance characteristics of diffusive samplers used for the determination of concentrations of gas

20、es and vapours in ambient atmospheres. With regard to air quality, the objectives fixed in the 5th Action Programme of the European Union are for the effective protection of all people against recognised risks from air pollution and the establishment of permitted concentration levels of air pollutan

21、ts, which should take into account the protection of the environment. These objectives include monitoring of concentrations with regard to standards. Successive programmes of action of the European Union on the protection of the environment have stressed the need to find a balance between the use of

22、 different tools: product standards, emission limits and environmental objectives/standards. The implementation of existing Directives has highlighted the existence of various problems, which are being addressed in the Council Directive on Ambient Air Quality Assessment and Management 1. These inclu

23、de: the different monitoring strategies in comparable situations between and within Member States; the harmonisation of measuring methods; the quality of the measurements which depends on the calibration and quality assurance procedures. Diffusive samplers used to measure air quality have to fulfil

24、some general requirements, which are given in this part of EN 13528. These requirements include unambiguity, selectivity and Data Quality Objectives, including uncertainty. Such general requirements can also be appropriate for other measurement procedures used in the assessment of ambient air qualit

25、y. In addition, diffusive samplers used to measure air quality shall also fulfil some specific requirements in addition to those specified in this part of EN 13528. These specific requirements are given in EN 13528-2. EN 13528-3 gives guidance on the selection, use and maintenance of diffusive sampl

26、ers used to measure ambient air quality. It is the users primary responsibility to choose appropriate procedures or devices that meet the requirements in this European Standard. One way of doing this is to obtain information or confirmation from the manufacturer. Type testing, or more generally, the

27、 assessment of performance criteria of procedures or devices, can be undertaken by the manufacturer, user, test house or research and development laboratory, as is most appropriate. Although this part of EN 13528 specifically addresses ambient air, diffusive sampling is also relevant to the assessme

28、nt of air quality in indoor air. Both pumped and diffusive sampling procedures are considered appropriate for such measurements, depending on circumstances (particularly any requirement for time resolution) 2. prEN 14412 gives guidance on the selection, use and maintenance of diffusive samplers used

29、 to measure indoor air quality. This part of EN 13528 is similar in content to EN 482:1994 and EN 13528-2 is similar in content to EN 838:1995.The series of standards on the use of diffusive samplers for ambient air has been created in addition to those for workplace air because the underlying Europ

30、ean Directives are different and the consequent definitions and practical applications of the estimation of the uncertainty of measurements are different. EN 13528-1:2002 (E) 5 1 Scope This European Standard specifies general performance requirements for diffusive samplers used for the determination

31、 of the concentration of gases and vapours in ambient air. Such requirements apply to all diffusive samplers, irrespective of the physical nature of the rate controlling process and irrespective of the nature of the sorption process and the analytical determination. This standard applies to all stag

32、es of the measuring procedure, including deployment, transportation and storage of the sample where appropriate. This standard applies to measuring procedures with separate sampling and analysis stages, and also to direct- reading devices. 2 Normative references This European Standard incorporates b

33、y dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Sta

34、ndard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). ENV 13005, Guide to the expression of uncertainty in measurement. EN ISO/IEC 17025, General requirements for the competence of testing

35、 and calibration laboratories (ISO/IEC 17025:1999). ISO 5725:1994, Accuracy (trueness and precision) of measurement methods and results (all parts). 3 Terms and definitions For the purpose of this European Standard the following terms and definitions apply. 3.1 ambient air outdoor air in the troposp

36、here, excluding indoor air and workplaces 3.2 averaging time period of time for which the measuring procedure yields a single value EN 482:1994 3.3 bias difference between the expectation of the test results and an accepted reference value ISO 3534-1:1993 3.4 combined standard uncertainty standard u

37、ncertainty of the result of a measurement when that result is obtained from the values of a number of other quantities, equal to the positive square root of a sum of terms, the terms being the variances or covariances of these other quantities weighted according to how the measurement result varies

38、with changes in these quantities ENV 13005 3.5 desorption efficiency ratio of the mass of analyte desorbed from a sampling device to that applied EN 838:1995 EN 13528-1:2002 (E) 6 3.6 diffusive sampler device which is capable of taking samples of gases or vapours from the atmosphere at a rate contro

39、lled by a physical process such as gaseous diffusion through a static air layer or a porous material and/or permeation through a membrane, but which does not involve the active movement of air through the device NOTE 1 Active normally refers to the pumped movement of air. NOTE 2 This definition diff

40、ers from that in EN 838:1995 by the addition of the words or a porous material. 3.7 expanded uncertainty quantity defining an interval about the result of a measurement that may be expected to encompass a large fraction of the distribution of values that could reasonably be attributed to the measura

41、nd NOTE 1 The fraction may be viewed as the coverage probability or level of confidence of the interval. NOTE 2 To associate a specific level of confidence with the interval defined by the expanded uncertainty requires explicit of implicit assumptions regarding the probability distribution character

42、ised by the measurement result and its combined standard uncertainty. The level of confidence that can be attributed to the interval can be known only to the extent to which such assumptions may be justified. NOTE 3 Expanded uncertainty is termed overall uncertainty in ENV 13005. ENV 13005 3.8 measu

43、ring procedure procedure for sampling and analysing one or more pollutants in ambient air and including storage and transportation of the sample 3.9 repeatability conditions conditions where independent test results are obtained with the same method on identical test items in the same laboratory by

44、the same operator using the same equipment within short intervals of time ISO 3534-1:1993 3.10 reproducibility conditions conditions where test results are obtained with the same method on identical test items in different laboratories with different operators using different equipment ISO 3534-1:19

45、93 3.11 selectivity degree of independence from interferents 3.12 standard uncertainty uncertainty of the result of a measurement expressed as a standard deviation ENV 13005 3.13 uncertainty (of measurement) parameter, associated with the results of a measurement, that characterises the dispersion o

46、f values that could reasonably be attributed to the measurand NOTE 1 The parameter may be, for example, a standard deviation (or given multiple of it), or the half width of an interval having a stated level of confidence. NOTE 2 Uncertainty of measurement comprises, in general, many components. Some

47、 of these components may be evaluated from the statistical distribution of the results of a series of measurements and can be characterised by experimental standard EN 13528-1:2002 (E) 7 deviations. The other components, which can also be characterised by standard deviations, are evaluated from assu

48、med probability distributions based on experience or other information. NOTE 3 It is understood that the result of a measurement is the best estimate of the value of a measurand, and that all components of uncertainty, including those arising from systematic effects, such as components associated wi

49、th corrections and reference standards, contribute to this dispersion ENV 13005. Attention is drawn to the fact that the terms Assessment, Limit Value and Pollutant are defined in Directive 96/62/EC 1. 4 Assessment regimes Different regimes of air quality assessment are possible for the implementation of the Council Directive on Ambient Air Quality Assessment and Management 1, and successive Daughter Directives, in which the measurement requirements are

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1