1、BRITISH STANDARD BS EN 1365-5:2004 Fire resistance tests for loadbearing elements Part 5: Balconies and walkways The European Standard EN 1365-5:2004 has the status of a British Standard ICS 13.220.50 ? Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Uncontrolled Copy

2、, (c) BSI BS EN 1365-5:2004 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 18 November 2004 BSI 18 November 2004 ISBN 0 580 44791 X National foreword This British Standard is the official English language version of EN 1365-5:2004. The UK pa

3、rticipation in its preparation was entrusted by Technical Committee FSH/22, Fire resistance tests, to Subcommittee FSH/22/7, Test procedures for partitions and walls, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary

4、. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue

5、or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the te

6、xt; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front co

7、ver, an inside front cover, the EN title page, pages 2 to 11 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GM

8、T+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1365-5 November 2004 ICS 13.220.50 English version Fire resistance tests for loadbearing elements - Part 5: Balconies and walkways Essais de rsistance au feu des lments porteurs - Partie 5: Balcons et passe

9、relles Feuerwiderstandsprfungen fr tragende Bauteile - Teil 5: Balkone und Laubengnge This European Standard was approved by CEN on 9 July 2004. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a

10、national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version i

11、n any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, F

12、inland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE

13、 FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2004 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1365-5:2004: E Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Uncontrolled Copy

14、, (c) BSI EN 1365-5:2004 (E) 2 Contents page Foreword3 Introduction.4 1 Scope 5 2 Normative references5 3 Terms and definitions .5 4 Test equipment 7 5 Test conditions 7 5.1 Furnace.7 5.2 Loading conditions7 6 Test specimen7 6.1 General7 6.2 Size7 6.3 Number .9 6.4 Design.9 6.4.1 General9 6.4.2 Floo

15、r9 6.5 Exposure.9 6.6 Construction.9 6.7 Verification .9 7 Installation of test specimen 10 7.1 General10 7.2 Loading and restraint10 8 Conditioning.10 9 Application of instrumentation.10 9.1 Furnace thermocouples (plate thermometers).10 9.2 Pressure10 9.3 Deflection10 10 Test procedure.10 11 Perfor

16、mance criteria11 12 Test report11 13 Field of direct application of test results 11 Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1365-5:2004 (E) 3 Foreword This document (EN 1365-5:2004) has been prepared by Technical Committee CEN/TC

17、127 “Fire safety in buildings”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2005, and conflicting national standards shall be withdrawn at the late

18、st by May 2005. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of the Construction Products Directive. EN 1365 Fire resistance tests for loadbearing elements consists of the followin

19、g parts: Part 1: Walls, Part 2: Floors and roofs, Part 3: Beams, Part 4: Columns, Part 5: Balconies and walkways, Part 6: Stairs. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria,

20、 Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffield

21、un, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1365-5:2004 (E) 4 Introduction The purpose of this test is to measure the ability of a representative specimen of a balcony or walkway or a part of those to maintain its loadbearing capacity when exposed to fire according to E

22、N 1363-1. Caution The attention of all persons concerned with managing and carrying out this fire resistance test is drawn to the fact that fire testing can be hazardous and that there is a possibility that toxic and/or harmful smoke and gases can be evolved during the test. Mechanical and operation

23、al hazards can also arise during the construction of the test elements or structures, their testing and disposal of test residues. An assessment of all potential hazards and risks to health should be made and safety precautions should be identified and provided. Written safety instructions should be

24、 issued. Appropriate training should be given to relevant personnel. Laboratory personnel should ensure that they follow written safety instructions at all times. Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1365-5:2004 (E) 5 1 Scope T

25、his Part of EN 1365 specifies a method for determining the fire resistance, in respect with loadbearing capacity and with no separating function, of: balconies exposed to the fire from either outside or inside the building; and walkways exposed to the fire from either outside or inside the building.

26、 This standard is used in conjunction with EN 1363-1. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includi

27、ng any amendments) applies. EN 1363-1:1999, Fire resistance tests Part 1: General requirements. EN 1365-2, Fire resistance tests for loadbearing elements Part 3: Floors and roofs. EN 1365-3, Fire resistance tests for loadbearing elements Part 3: Beams. EN 1365-4, Fire resistance tests for loadbearin

28、g elements Part 4: Columns. EN ISO 13943:2000, Fire safety Vocabulary (ISO 13943:2000). 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1363-1:1999 and EN ISO 13943:2000 and the following apply. 3.1 balcony platform on the inside or outside of the bui

29、lding, usually balustrated, with access from an upper floor window or door. It may be integrated in the building structure or free standing. It may consist of floor, beams, columns, walls, tension bars and balustrades. It does not serve as a separating building element 3.2 walkway raised passage or

30、pass for pedestrian access connecting different sections of a building. It may be inside or outside the building and may be integrated in building structure or free standing. It does not serve as a separating building element 3.3 balcony or walkway floor horizontal loadbearing element 3.4 balustrade

31、 railing supported by posts or pillars forming a parapet to a balcony or walkway and designed to prevent the user falling over the side NOTE Examples of sections of different type of balconies and walkways are given in Figure 1. Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GMT+00:

32、00 2006, Uncontrolled Copy, (c) BSI EN 1365-5:2004 (E) 6 Key 1 Balcony or walkway floor 2 Column 3 Tension bar 4 Balustrade 5 Handrail 6 Baluster Figure 1 Examples of types of balconies and walkways Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Uncontrolled Copy, (c

33、) BSI EN 1365-5:2004 (E) 7 4 Test equipment The test equipment shall be as specified in EN 1363-1. 5 Test conditions 5.1 Furnace The heating conditions, the furnace atmosphere and loading conditions shall conform to those specified in EN 1363-1. When testing balconies, walkways or their components,

34、a pressure of 20 Pa shall be established at the position 100 mm below the underside of the furnace cover slab. 5.2 Loading conditions The test specimen shall be subjected to loads determined in accordance with EN 1363-1. The determination of the load shall be clearly indicated in the test report. Th

35、e magnitude and the distribution of the load shall be such that the maximum stresses produced in the test specimen are representative of those in practice. 6 Test specimen 6.1 General The test specimen is the complete balcony or walkway, or part of it, chosen to represent the most onerous conditions

36、 of failure. If the fire resistance of a component will not be negatively influenced by the complete system, then the complete balcony or walkway can be represented by a part of the complete system and tests may be carried out on that part according to EN 1365-3 and/or EN 1365-4. 6.2 Size The test s

37、pecimen shall be full size unless the actual size is larger than can be accommodated in the furnace. When the actual size cannot be accommodated in the furnace, the height of the test specimen shall be 3 m and the dimensions (length and width) of a balcony at least 3 m 3 m and of a walkway at least

38、4 m 3 m. Part of the balcony or walkway shall be tested in a way such that the result is representative for the entire construction. A floor shall be tested with a size as specified in EN 1365-3. A column shall be tested with a size as specified in EN 1365-4. A tension member shall be tested as a co

39、lumn with a size as specified in EN 1365-4. A beam shall be tested with a size as specified in EN 1365-3. A balustrade shall be tested with a size as specified in EN 1365-3. NOTE Examples of testing configurations of a whole balcony or part of it are shown in Figure 2. Licensed Copy: sheffieldun she

40、ffieldun, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1365-5:2004 (E) 8 Key 1 Furnace enclosure 2 Loading frame 3 Extension of furnace 4 Test specimen 5 Supporting structure of balcony or walkway (forming enclosure of furnace) 6 Loadbearing column Figure 2 Examples of testi

41、ng a balcony or a walkway Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 1365-5:2004 (E) 9 6.3 Number For a given set of support, restraint, loading and exposure conditions one test specimen shall be tested. 6.4 Design 6.4.1 General The

42、test specimen shall simulate the conditions of the use of balcony or walkway in practice. It shall include all construction details, materials and components (including water proofing and drainage system) and shall be supported as in practice. An example of each type of mechanical joint or connectio

43、n contained within the element for purposes of erection, construction or expansion shall be incorporated in the test construction, even though such joints may in practice occur at greater centres than the relevant dimension of the test specimen. Different jointing systems shall not be included in a

44、single test specimen, unless it can be shown that they will not interfere with the performance of each other. 6.4.2 Floor The distance between the furnace wall or the associated construction and the nearest side of the beam or joist along the free edges shall be representative of the situation in pr

45、actice. For a construction with an exposed length/width greater than 3 m containing beams, the distance of both edge beams to the nearest centre beams may be reduced. In this case additional loading shall be applied on them to produce stress levels equal to those in the other beams. The connections/

46、junctions of the periphery of the floor with the associated construction shall be carried out in accordance with the sponsors instructions. At the free edges of a one-way spanning structure, the peripheral conditions shall allow freedom for deflection. Where in the test configuration the free edges

47、are exposed, where they would not be exposed in practice, these edges shall be sealed with mineral wool and/or other materials according to the sponsor. 6.5 Exposure Heating conditions shall be as specified in EN 1363-1. The test specimen shall be exposed to fire in a manner representative of the wa

48、y it would be exposed in practice. 6.6 Construction The test specimen shall be constructed as described in EN 1363-1. 6.7 Verification Verification of the test specimen shall be carried out as described in EN 1363-1. Licensed Copy: sheffieldun sheffieldun, na, Sun Oct 29 09:35:50 GMT+00:00 2006, Unc

49、ontrolled Copy, (c) BSI EN 1365-5:2004 (E) 10 7 Installation of test specimen 7.1 General The test specimen (a balcony or a walkway, their part or a component) shall be installed in a manner representative of its use in practice. 7.2 Loading and restraint The test specimen representing a balcony or a walkway, or their parts, shall be tested to simulate end use boundary conditions. The magnitude and the distribution of the load shall be such that the maximum stresses p