1、BRITISH STANDARD BS EN 15207:2006 Tanks for transport of dangerous goods Plug/socket connection and supply characteristics for service equipment in hazardous areas with 24 V nominal supply voltage The European Standard EN 15207:2006 has the status of a British Standard ICS 13.300; 23.020.20 ? Licens

2、ed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 15207:2006 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007 ISBN 978-0-580-49968

3、-5 National foreword This British Standard was published by BSI. It is the UK implementation of EN 15207:2006. The UK participation in its preparation was entrusted to Technical Committee AUE/18, Tanks for the transport of dangerous goods. A list of organizations represented on AUE/18 can be obtaine

4、d on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. Da

5、teComments Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15207 December 2006 ICS 13.300; 23.020.20 English Version Tanks for transport of dangerous goods -

6、 Plug/socket connection and supply characteristics for service equipment in hazardous areas with 24 V nominal supply voltage Citernes destines au transport de matires dangereuses - Prises et embases de raccordement, caractristiques de lalimentation lectrique des quipements de service en atmosphre ex

7、plosible Tanks fr die Befrderung gefhrlicher Gter - Steckvorrichtung und elektrische Kennwerte der Versorgung von Bedienungsausrstungen in explosionsgefhrdeten Bereichen This European Standard was approved by CEN on 11 November 2006. CEN members are bound to comply with the CEN/CENELEC Internal Regu

8、lations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This E

9、uropean Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the n

10、ational standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United

11、Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2006 CENAll rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15207:2006: E

12、Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative references4 3 Terms and definitions .4 4 Power supply characteristics.5 4.1 Service equipment en

13、ergy consumption 5 4.2 Current ratings of supplies.5 4.3 Voltages rating.5 5 Design characteristics 5 5.1 Plug/socket connection 5 5.2 Optional additional connections8 5.3 Ambient operational temperature range .8 6 Tests8 7 Marking.9 7.1 Type plate .9 7.2 Warning sign9 Annex A (informative) Example

14、for wiring10 Bibliography12 Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 3 Foreword This document (EN 15207:2006) has been prepared by Technical Committee CEN/TC 296 “Tanks for transport of

15、 dangerous goods”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2007, and conflicting national standards shall be withdrawn at the latest by June

16、 2007. This European Standard forms part of a coherent standards programme comprising the following standards: EN 13616, Overfill prevention devices for static tanks for liquid petroleum fuels. EN 13922, Tanks for transport of dangerous goods Service equipment for tanks Overfill prevention systems f

17、or liquid fuels. EN 14116, Tanks for transport of dangerous goods Digital interface for the product recognition device. EN 15208, Tanks for transport of dangerous goods Sealed parcel delivery systems Working principles and interface specifications. According to the CEN/CENELEC Internal Regulations,

18、the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Po

19、land, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 4 1 Scope This European Standard specifies the inter

20、operability requirements for the tractor/trailer and/or transport tank/trailer plug/socket for the use in hazardous areas, being: the connection used for the supply Type A and supply Type S electrical power to service equipment; and the supply characteristics for each operating mode. This plug/socke

21、t combination includes provisions for future connections including data transfer. The plug/socket connection is not used for purposes which are specified in other standards for truck trailer connections e.g. ISO 12098 and ISO 7638-1. 2 Normative references The following referenced documents are indi

22、spensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 60079-0, Electrical apparatus for explosive gas atmospheres Part 0: General requirements

23、(IEC 60079-0:2004) EN 60079-7, Electrical apparatus for explosive gas atmospheres Part 7: Increased safety “e“ (IEC 60079-7:2001) EN ISO 8092-2, Road vehicles Connections for on-board electrical wiring harnesses Part 2: Definitions, test methods and general performance requirements (ISO 8092-2:2005)

24、 ISO 4091, Road vehicles Connectors for the electrical connection of towing and towed vehicles Definitions, tests and requirements ISO 8820-1, Road vehicles Fuse-links Part 1: Definitions and general test requirements ISO 8820-3, Road vehicles Fuse-links Part 3: Fuse-links with tabs (blade type) ISO

25、 8820-4, Road vehicles Fuse-links Part 4: Fuse-links with female contacts (type A) and bolt-in contacts (type B) and their test fixtures ISO 12098, Road vehicles Connectors for the electrical connection of towing and towed vehicles 15-pole connector for vehicles with 24 V nominal supply voltage ISO

26、16750-3, Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 3: Mechanical loads 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 supply Type A one that is designed to remain safely active in hazardo

27、us areas (e.g. while the switch for operation in hazardous areas is open) Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 5 3.2 supply Type S one that is designed to be switched off in hazardo

28、us areas 4 Power supply characteristics 4.1 Service equipment energy consumption The consumption of the service equipment shall not exceed 6 Ah for a period of 2 h or 30 Ah for a period of 72 h. NOTE For tractors/tank trucks which have a plug/socket connection according to this European Standard, th

29、e design of the tractor/tank truck should consider this fact e.g. for the design of the battery, generator etc. The consumption of the service equipment is limited according to 4.2 and 4.3. 4.2 Current ratings of supplies The supply Type A and the supply Type S shall be fused with melting fuses of 5

30、 A according to ISO 8820-1, ISO 8820-3 and ISO 8820-4. 4.3 Voltages rating The voltages rating shall be the nominal 24 V DC. 5 Design characteristics 5.1 Plug/socket connection 5.1.1 General Plug/socket connection according to ISO 12098, ISO 8092-2 and ISO 16750-3. To avoid mismating of this plug/so

31、cket connection with other plug/socket connections according to ISO 12098 or similar plug/socket connections, any insertion force 1 000 N shall not result in an electrical contact. Additional or exceptional requirements according to 5.1.2 to 5.1.5. 5.1.2 Requirements for operation in hazardous areas

32、 Tractor/trailer connection shall fulfil the requirements of equipment category 2, gas group IIC and temperature class T6 under consideration that no connection/disconnection happens in a hazardous area. Operating voltage U 60 V according to EN 60079-7 regarding isolation. The plug/socket connection

33、 shall be designed according to Figure 1 to Figure 3 to prevent accidental disconnection. It shall only be possible to unscrew the screw with a tool. The screw shall be captive and self- locking with a thread dimension M 4 16. All connections except those used by the power supply shall be limited to

34、 a current Ioc 4 A per pin. Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 6 Dimensions in millimetres Key 1 screw Figure 1 Locking mechanism for plug/socket Figure 2 Plug Licensed Copy: Lond

35、on South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 7 NOTE Socket without cover. Figure 3 Socket, fixed installed 5.1.3 Pin use restriction Any pin, except those dedicated to supply Type S, may be energized at any t

36、ime. Certified and non-certified equipment connected to any pin, except those assigned to supply Type A or supply Type S, shall be designed to prevent the current exceeding 4 A (fuse rating) per pin. The compatibility of the equipment using the data transfer pins defined in this European Standard is

37、 the responsibility of the operator. 5.1.4 Keying Keying of plug/socket shall be according to Figure 2 and Figure 3. The colour of the plug and socket shall not be blue. 5.1.5 Pin assignment The number of pins shall be 15. All plug/socket connections according to Table 1 shall have the same pin assi

38、gnment. Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 8 Table 1 Pin assignment Pin number Function 1 Data transfer: a 2 Data transfer: b 3 Data transfer ground 4 Supply Type S, ground 5 Rese

39、rved for future use a 6 Supply Type S, DC +24 V 7 Reserved for future use a 8 Reserved for future use a 9 Supply Type A, DC +24 V 10 Reserved for future use a 11 Reserved for data transfer 12 Reserved for future use a 13 Supply Type A, ground 14 Reserved for future use a 15 Reserved for future use a

40、 a Not connected. 5.2 Optional additional connections 5.2.1 General Optional additional connections shall fulfil the requirements according to 5.1. 5.2.2 Cab socket A cab socket may be fixed mounted or flying lead, see Annex A. 5.3 Ambient operational temperature range The plug/socket connection may

41、 be used in an ambient operational temperature range from 40 C to +60 C. 6 Tests The plug/socket connection shall be tested according to ISO 12098, EN ISO 8092-2 and ISO 16750-3. The test for mismating according to 5.1.1 shall be carried out according to ISO 4091. Licensed Copy: London South Bank Un

42、iversity, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 9 7 Marking 7.1 Type plate Information according to EN 60079-0; reference to this European Standard, i.e. EN 15207. 7.2 Warning sign A warning sign according to EN 60079-7 regardi

43、ng connection/disconnection in hazardous area shall be provided. Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 10 Annex A (informative) Example for wiring Figure A.1 shows the schematic wiri

44、ng to achieve the non-interruptible and interruptible power supply to the service equipment via plug/socket connections. Option 9 shows connection to trailer by extension cable. Option 5 shows connection to service equipment installed in the cabin. The options 5 and 9 are not requested, but if they

45、are used, then it shall be according to the standard. The wiring of all plug/socket connections (7 - 8) shall be the same. Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 11 Key A-D interconne

46、cting cable B tractor/tank truck side C trailer side 1 battery 2 switch, to be broken in hazardous areas 3 current limiting device, sized to protect plug socket connection and battery 4 service equipment on the trailer 5 optional plug/socket connection in the driver cabin 6 service equipment in the

47、driver cabin to be compatible with 4 7 male side of 15 pins plug/socket connection 8 female side of 15 pins plug/socket connection 9 optional plug/socket connection on the trailer 10 to existing 15-pole connector 11 supply Type S 12 supply Type A Figure A.1 Wiring schematic with single line represen

48、tation Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 15207:2006 (E) 12 Bibliography 1 ISO 7638-1, Road vehicles Connectors for the electrical connection of towing and towed vehicles Part 1: Connectors for

49、braking systems and running gear of vehicles with 24 V nominal supply voltage Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI blank Licensed Copy: London South Bank University, London South Bank University, Thu Jan 18 00:54:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 15207:2006 BSI 389 Chiswick High Road London W4 4AL BSI