1、BRITISH STANDARD BS EN 50107-2:2005 Signs and luminous-discharge- tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2: Requirements for earth-leakage and open-circuit protective devices The European Standard EN 50107-2:2005 has the status of

2、 a British Standard ICS 29.140.30 ? Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 50107-2:2005 This British Standard, was published under the authority of the Standards Policy and Strategy Committee on 29 April 2005 BSI 29 April 2005

3、 ISBN 0 580 45944 6 National foreword This British Standard is the official English language version of EN 50107-2:2005. The UK participation in its preparation was entrusted by Technical Committee CPL/34, Lamps and related equipment, to Subcommittee CPL/34/11, Electric signs, which has the responsi

4、bility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “In

5、ternational Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a

6、 British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related internation

7、al and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 20, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last

8、 issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 50107-2 NORME EUROPENNE EUROPISCHE NORM April 2005 CENELEC European Committee for Electrotechnical Standa

9、rdization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50107-2:200

10、5 E ICS 29.140.30 English version Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV Part 2: Requirements for earth-leakage and open-circuit protective devices Installation denseignes et de tubes lumineux dcharge fonct

11、ionnant une tension de sortie vide assigne suprieure 1 kV mais ne dpassant pas 10 kV Partie 2: Prescriptions pour les dispositifs de protection contre les dfauts disolement et contre louverture des circuits secondaires Leuchtrhrengerte und Leuchtrhrenanlagen mit einer Leerlaufspannung ber 1 kV, aber

12、 nicht ber 10 kV Teil 2: Anforderungen an Erdschlussschutz- und Leerlaufschutzeinrichtungen This European Standard was approved by CENELEC on 2005-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the

13、 status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, Ger

14、man). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus,

15、 Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 0

16、6 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50107-2:2005 - 2 - Foreword This European Standard was prepared by CENELEC BTTF 60-2, Electrical discharge lamp installations. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50107-2 on 2005-03-01. The

17、following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2006-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-03-01 _ Licensed Cop

18、y: sheffieldun sheffieldun, na, Mon Nov 06 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI - 3 - EN 50107-2:2005 Contents Page 1 Scope5 2 Normative references5 3 Definitions5 4 General requirements.6 5 Tests.6 6 Classification.7 7 Marking.7 7.1 Items of marking7 7.2 Durability of marking7 7.3 Ad

19、ditional information7 8 Terminals8 9 Provision for protective earthing.8 10 Protection against accidental contact with live parts.8 11 Moisture resistance and insulation of type B devices8 12 Electric strength9 13 Thermal endurance of devices9 13.1 General9 13.2 Tests for type B devices 9 13.3 Tests

20、 for type A or type C devices.9 14 Fault conditions 10 15 Construction10 16 Creepage distances and clearances.10 17 Screws, current-carrying parts and connections10 18 Resistance to heat, fire and tracking10 19 Resistance to corrosion.10 20 Performance10 20.1 Performance requirements for earth-leaka

21、ge protective devices10 20.2 Performance requirements for open-circuit protective devices.11 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50107-2:2005 - 4 - 20.3 Performance requirements common to both types of device11 21 Interchangea

22、bility .12 Annex A (normative) - Testing of the response time of earth-leakage protective devices 13 Annex B (informative) - An example method of measuring the performance of an earth-leakage protective device15 Annex C (normative) - Test of the response time of open-circuit protective devices 17 An

23、nex D (informative) - A method of measuring the performance of an open-circuit protective device.19 Figure B.1 - Typical circuit to measure the performance of an earth-leakage protective device.14 Figure D.1 - Typical circuit to measure the performance of an open-circuit protective device 18 License

24、d Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI - 5 - EN 50107-2:2005 1 Scope This European Standard specifies requirements for earth-leakage and open-circuit protective devices designed to protect circuits for neon tubes operating from transformer

25、s conforming to EN 61050 at voltages exceeding 1 000 V but not exceeding 10 000 V. NOTE 1 Requirements for the installation of earth-leakage and open-circuit protective devices are given in EN 50107-1. NOTE 2 Requirements for earth-leakage and open-circuit protective devices used with inverters and

26、converters are specified in EN 61347-2-10. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amen

27、dments) applies. EN 50107-1:2002, Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV - Part 1: General requirements EN 60529:1991, Degrees of protection provided by enclosures (IP code) (IEC 60529:1989) EN 60598-1:2000

28、, Luminaires - Part 1: General requirements and tests (IEC 60598-1:1999, mod.) EN 61050:1992, Transformers for tubular discharge lamps having a no-load output voltage exceeding 1 kV (generally called neon-transformers) - General and safety requirements (IEC 61050:1991 + corrigendum March 1992, mod.)

29、 EN 61347-1:2001, Lamp controlgear - Part 1: General and safety requirements (IEC 61347-1:2000) 3 Definitions For the purposes of this European Standard, the definitions given in EN 50107-1 and EN 61347-1 apply, together with the following. NOTE Where the terms “voltage” and “current” are used, they

30、 refer to r.m.s. values unless otherwise stated. 3.1 type A device earth-leakage or open-circuit protective device generally designed to be built into the enclosure of a transformer and not intended to be mounted outside a transformer without special precautions NOTE A type A device normally protect

31、s only the transformer in which it is mounted. 3.2 type B device earth-leakage or open-circuit protective device consisting of one or more separate elements so designed that it can be mounted outside a transformer and housed in an enclosure that provides all necessary protection according to its mar

32、kings NOTE 1 The enclosure may consist of the sign in which the device is mounted; the sign having a protection according to its markings. NOTE 2 The device may protect more than one transformer. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) B

33、SI EN 50107-2:2005 - 6 - 3.3 type C device earth-leakage or open-circuit protective device that forms a non-replaceable part of a transformer and which normally cannot be tested separately from the transformer 3.4 earth-leakage current fault current flowing from a point in the output circuit to eart

34、h 3.5 open-circuit condition discnnection or lamp fault in the output circuit that causes the secondary load current of the transformer feeding the lamp circuit to fall below the respective shut-down current limit 3.6 shut-down current limit secondary load current of a transformer at which an open-c

35、ircuit protective device operates NOTE Although the shut-down current limit is specified in terms of the current flowing in the output circuit, the manufacturer of the device may measure this by other than direct means. Such means might include, e.g. measuring the current reflected into the primary

36、winding of the transformer or measuring a change in circuit power factor. 3.7 sensor device that detects an earth-leakage current or, in the case of an open-circuit protective device, detects when the secondary load current has fallen below the shut-down current limit, and either causes a protective

37、 switch to operate or otherwise causes the output voltage of a transformer to be removed 3.8 protective switch part of an earth-leakage or open-circuit protective device that disconnects the mains supply from a transformer 3.9 response time time from the start of the fault condition until the protec

38、tive device removes the output voltage 3.10 secondary load current current flowing in the output circuit of transformer supplying one or more tubes 4 General requirements EN 61347-1:2001, Clause 4, shall apply, with the words “earth-leakage protective device” or “open- circuit protective device” (as

39、 appropriate) substituted for “lamp controlgear”. 5 Tests 5.1 With the exception of EN 61347-1:2001, Subclause 5.4 (see 5.2), EN 61347-1:2001, Clause 5, shall apply, with the words “earth-leakage protective device” or “open-circuit protective device” (as appropriate) substituted for “lamp controlgea

40、r”. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI - 7 - EN 50107-2:2005 5. 2 The requirements of EN 61347-1:2001, Subclause 5.4, shall be replaced by the following: a) a total of ten devices shall be selected at random for the tests; b) ty

41、pe A devices shall be tested with a representative sample of the associated transformer in which the device is normally mounted; c) type B devices shall be tested with transformers having characteristics at either end of the range specified in accordance with 7.3 h); d) type C devices shall be teste

42、d complete with their associated transformers; e) three devices, taken at random from the batch of ten, shall be tested in accordance with the relevant tests specified in this European Standard. The results shall be assessed as follows: 1) if all three samples pass all the tests, the batch shall be

43、deemed to conform to this European Standard; 2) if two or more samples fail any of the tests, the batch shall be deemed not to conform to this European Standard; 3) if one sample fails any of the tests, the tests shall be repeated on a second batch of three devices; 4) if all three devices from this

44、 second batch pass all the tests, the batch shall be deemed to conform to this European Standard; 5) if any device from this second batch fails any of the tests, the entire batch shall be deemed not to conform to this European Standard. 6 Classification EN 61347-1:2001, Clause 6 shall apply, with th

45、e words “earth-leakage protective device” or “open- circuit protective device” (as appropriate) substituted for “lamp controlgear”. 7 Marking 7.1 Items of marking The following items shall be marked, either: a) on the device itself, in the case of type A or type B devices; or b) on the label attache

46、d to the transformer in which the device is housed, and in the case of type C devices with: 1) the number of this European Standard, i.e. EN 50107-2; 2) the items specified in EN 61347-1:2001, Subclause 7.1 a), b), f), and l), with the words “earth-leakage protective device” or “open-circuit protect

47、ive device” (as appropriate) substituted for “lamp controlgear”. 7.2 Durability of marking The durability of the marking shall conform to the requirements of EN 61347-1:2001, Subclause 7.2. 7.3 Additional information In addition to the items specified in 7.1, the following information, if applicable

48、, shall be given in the manufacturers instructions to be provided with both earth-leakage and open-circuit protective devices: a) the items specified in EN 61347-1:2001, Subclause 7.1 h), i) and k), with the words “earth- leakage protective device” or “open-circuit protective device” (as appropriate

49、) substituted for “lamp controlgear”; Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 50107-2:2005 - 8 - b) the information necessary for the test specified in EN 50107-1:2002, Clause 18, to be carried out; c) the information necessary for the safe installation of the device in accordance with the requirements of EN 50107-1; d) the information necessary for the device to be disabled manually for maint

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1