1、BRITISH STANDARD BS EN 55015:1996 CISPR 15: 1996 Incorporating Amendments Nos. 1 and 2 and Corrigendum No. 1 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment The European Standard EN 55015:1996 with the inclusion of amendments A1:199

2、7 and A2:1999 has the status of a British Standard ICS 29.140.01; 33.100.10 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:14 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 55015:1996 This British Standard, having been prepared under the direction of the Electrotechnical Sector Board

3、, was published under the authority of the Standards Board and comes into effect on 15 November 1996 BSI 01-2001 First published June 1993 Second edition November 1996 The following BSI references relate to the work on this standard: Committee reference GEL/210/6 Draft for comment 92/03067 DC ISBN 0

4、 580 26080 1 Committees responsible for this British Standard The preparation of this British Standard was entrusted by Technical Committee GEL/210, Electromagnetic compatibility, to Subcommittee GEL/210/6, Equipment, lighting fittings and domestic appliances, upon which the following bodies were re

5、presented: Association of Consulting Scientists Association of Control Manufacturers TACMA (BEAMA Ltd.) Association of Manufacturers of Domestic Electrical Appliances BEAMA Ltd. British Combustion Equipment Manufacturers Association British Lighting Association for the Preparation of Standards (BRIT

6、LAPS) British Radio and Electronic Equipment Manufacturers Association British Sign Association British Toy and Hobby Association Coopted members Electrical Installation Equipment Manufacturers Association (BEAMA Ltd.) ERA Technology Ltd. Federation of the Electronics Industry Lighting Industry Fede

7、ration Ltd. Portable Electric Tool Manufacturers Association Radio Society of Great Britain Radiocommunications Agency Amendments issued since publication Amd. No.DateComments 9766December 1997 10550January 2000 Indicated by a sideline 13031 Corrigendum No. 1 January 2001 In national foreword, date

8、of withdrawal of BS EN 55015:1993 corrected to 2000-01-01. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:14 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 55015:1996 BSI 01-2001i Contents Page Committees responsibleInside front cover National forewordii Foreword2 Text of EN 550155 L

9、ist of referencesInside back cover Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:14 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 55015:1996 ii BSI 01-2001 National foreword This British Standard has been prepared by Subcommittee GEL/210/6 and is the English language version of EN

10、55015:1996 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment, including amendments A1:1997 and A2:1999, published by the European Committee for Electrotechnical Standardization (CENELEC). It is identical with CISPR 15:1996 including A

11、mendments 1:1997 and 2:1998, published by the International Electrotechnical Commission (IEC). The foreword of the EN makes reference to the “date of withdrawal” (dow) of the relevant national standard. In this case the relevant national standard is BS EN 55015:1993 as amended by amendments Nos 1:19

12、93 and 2:1998, which will be withdrawn on 2000-01-01. The main technical changes are: limitation of the scope to electromagnetic disturbances only. A standard for immunity requirements for lighting equipment is prepared by IEC Technical Committee 34; full application of the limits to all kinds of li

13、ghting equipment; lamps, luminaires and auxiliaries; introduction of operating conditions for lighting equipment; change of the method of measurement of insertion loss. Annex A and Annex B form an integral part of this standard. Annex C is for information only. A British Standard does not purport to

14、 include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-references Publication referred toCorresponding British Standard IEC 50 (

15、161):1990BS 4727 Glossary of electrotechnical, power, telecommunication, electronics, lighting and colour terms Part 1 Terms common to power, telecommunications and electronics Group 09:1991 Electromagnetic compatibility EN 60155:1995 (IEC 155:1993) BS EN 60155:1995 Glow-starters for fluorescent lam

16、ps EN 60598 series IEC 598 series BS EN 60598 series Luminaires EN 55011:1991 CISPR 11:1990 BS EN 55011:1991 Specification for limits and methods of measurement of radio disturbance characteristics of industrial, scientific and medical (ISM) radio-frequency equipment Summary of pages This document c

17、omprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 42, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Sidelining in this document indicates the most recent changes by am

18、endment. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:14 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 55015 May 1996 + A1 July 1997 + A2 January 1999 ICS 33.100.10Supersedes EN 55015:1993 Descriptors: Radio disturbance, method of mea

19、surement, lighting equipment, luminaire, limit, evaluation, statistics English version Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (includes amendments A1:1997 and A2:1999) (CISPR 15:1996 + A1:1997 + A2:1998) Limites et mthodes

20、de mesure des perturbations radiolectriques produits par les appareils lectriques dclairage et les appareils analogues (inclut les amendements A1:1997 et A2:1999) (CISPR 15:1996 + A1:1997 + A2:1998) Grenzerte und Meverfahren fr Funkstrungen von elektrischen Beleuchtungseinrichtungen und hnlichen Ele

21、ktrogerten (enthlt nderungen A1:1997 und A2:1999) (CISPR 15:1996 + A1:1997 + A2:1998) This European Standard was approved by CENELEC on 1995-11-28. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the statu

22、s of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German).

23、A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Denmark, Finland, France, Ge

24、rmany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central S

25、ecretariat: rue de Stassart 35, B-1050 Brussels 1996 Copyright reserved to CENELEC members Ref. No. EN 55015:1996 + A1:1997 + A2:1999 E Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:14 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 55015:1996 BSI 01-2001 2 Foreword The text of document

26、 CISPR/F/186/FDIS + CISPR/F/186A/FDIS, future edition 5 of CISPR 15, prepared by CISPR SC F: Interference relating to household appliances, tools, lighting equipment and similar apparatus was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 55015 on 1995-11-28. This Europ

27、ean Standard supersedes EN 55015:1993. The following dates were fixed: For dimmers and similar electronic switches the terminal voltage disturbance limits of EN 55014:1993 apply until 2000-01-01. Annexes designated “normative” are part of the body of the standard. Annexes designated “informative” ar

28、e given for information only. In this standard, Annex A, Annex B and Annex ZA are normative and Annex C is informative. Annex ZA has been added by CENELEC. Foreword to amendment A1 The text of document CISPR/F/211/FDIS, future amendment 1 to CISPR 15:1996, prepared by CISPR SC F, Interference relati

29、ng to household appliances, tools, lighting equipment and similar apparatus, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to EN 55015:1996 on 1997-07-01. The following dates were fixed: Foreword to amendment A2 The text of document CISPR/F/254/FDIS, futu

30、re amendment 2 to CISPR 15:1996, prepared by CISPR SC F, Interference relating to household appliances, tools, lighting equipment and similar apparatus, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to EN 55015:1996 on 1999-01-01. The following dates were

31、 fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement(dop) 1996-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 2000-01-01 latest date by which the amendment h

32、as to be implemented at national level by publication of an identical national standard or by endorsement(dop) 1998-06-01 latest date by which the national standards conflicting with the amendment have to be withdrawn(dow) 2000-01-01 latest date by which the amendment has to be implemented at nation

33、al level by publication of an identical national standard or by endorsement(dop) 1999-10-01 latest date by which the national standards conflicting with the amendment have to be withdrawn(dow) 2001-10-01 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:14 GMT+00:00 2006, Uncontrolled Cop

34、y, (c) BSI EN 55015:1996 BSI 01-20013 Contents Page Foreword2 1Scope5 2Normative references5 3Definitions5 4Limits5 4.1Frequency ranges5 4.2Insertion loss6 4.3Disturbance voltages6 4.4Radiated electromagnetic disturbances6 4.5Limits at designated frequencies6 5Application of the limits7 5.1General7

35、5.2Designated frequencies7 5.3Indoor luminaires8 5.4Independent auxiliaries exclusively for use with lighting equipment8 5.5Self-ballasted lamps9 5.6Outdoor lighting appliances9 5.7UV and IR radiation appliances10 5.8Transport lighting10 5.9Neon and other advertising signs10 6Operating conditions fo

36、r lighting equipment11 6.1General11 6.2Lighting equipment11 6.3Supply voltage and frequency11 6.4Ambient conditions11 6.5Lamps11 6.6Replaceable starters11 7Method of insertion loss measurement11 7.1Circuits for the measurement of insertion loss11 7.2Measuring arrangement and procedure12 7.3Luminaire

37、12 7.4Measurement procedure12 8Method of measurement of disturbance voltages13 8.1Measuring arrangement and procedure13 8.2Indoor and outdoor luminaires13 8.3Independent light regulating devices14 8.4Independent transformers and convertors for incandescent lamps14 Page 8.5Independent ballasts for fl

38、uorescent and other discharge lamps14 8.6Self-ballasted lamps and semi-luminaires14 8.7UV and IR radiation appliances15 9Method of measurement of radiated electromagnetic disturbances15 9.1Measuring arrangement and procedure15 9.2Indoor and outdoor luminaires15 9.3Independent convertors for incandes

39、cent lamps15 9.4Independent ballasts for fluorescent and other discharge lamps15 9.5Self-ballasted lamps and semi-luminaires16 9.6UV and IR radiation appliances16 9.7Application of CISPR 16-116 10Interpretation of CISPR radio disturbance limits16 10.1 Significance of a CISPR limit16 10.2 Tests16 10.

40、3 Statistical method of evaluation16 10.4 The banning of sales17 Annex A Electrical and constructional requirements for the low-capacitance balance-to-unbalance transformer30 Annex B Magnetic field induced current method35 Annex C Relative sensitivities and conversion factors for large-loop antennas

41、 (LLAs)40 Annex ZA (normative) Normative references to international publications with their corresponding European publications42 Figure 1 Insertion loss measurement on linear and U-type fluorescent lamp luminaires18 Figure 2 Insertion loss measurement on circular fluorescent lamp luminaires19 Figu

42、re 3 Insertion loss measurement on luminaires for single-capped fluorescent lamps with integrated starter20 Figure 4a Configuration of linear and U-type dummy lamps21 Figure 4b Configuration of circular dummy lamps22 Figure 4c Dummy lamp for 15 mm fluorescent lamps23 Figure 4d Dummy lamp for 15 mm s

43、ingle capped fluorescent lamps24 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 07:48:14 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 55015:1996 4 BSI 01-2001 Page Figure 4e Dummy lamp for single-capped fluorescent lamps linear shaped, twin tube, tube diameter 12 mm25 Figure 4f Dummy lamp f

44、or single-capped fluorescent lamps linear shaped, quad tube, tube diameter 12 mm26 Figure 5 Measuring arrangements for an independent light regulating device, transformer or convertor27 Figure 6 Measuring arrangements28 Figure 7 Conical metal housing for self-ballasted fluorescent lamps29 Figure A.1

45、 Isolation test configuration31 Figure A.2a Balance-to-unbalance transformer circuit32 Figure A.2b Details of transformer core construction33 Figure A.2c Details of transformer core construction33 Figure A.2d Construction of transformer34 Figure B.1 Test set-up for measuring magnetic fields in X, Y

46、and Z direction (frequency range 9 kHz and 30 MHz)36 Figure B.2 Large-loop construction37 Figure B.3 Example of a slit construction for the large-loop antenna38 Figure B.4 Test set-up for verification of the large-loop antenna39 Figure C.1 Sensitivity of LLAs with a diameter of 1,0, 1,5, 3,0 and 4,0

47、 m relative to an LLA having a diameter of 2,0 m40 Figure C.2 Correlation between the current in the 2 m loop antenna and the magnetic field at the indicated distances41 Page Table 1 Minimum values of insertion loss6 Table 2a Disturbance voltage limits at mains terminals6 Table 2b Disturbance voltag

48、e limits at load and control terminals6 Table 3 Radiated electromagnetic disturbance limits7 Table 4 Limits of disturbance field strengths at frequencies designated for use by ISM equipment7 Table 5 Sample size and corresponding k factor in a non-central t-distribution17 Licensed Copy: sheffieldun s

49、heffieldun, na, Mon Nov 06 07:48:14 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 55015:1996 BSI 01-20015 1 Scope This standard applies to the emission (radiated and conducted) of radiofrequency disturbances from: all lighting equipment with a primary function of generating and/or distributing light intended for illumination purposes, and intended either for connection to the low voltage electricity supply or for battery operation; the lighting p