1、BRITISH STANDARD BS EN 60870-2-1:1996 IEC 870-2-1: 1995 Telecontrol equipment and systems Part 2: Operating conditions Section 1. Power supply and electromagnetic compatibility The European Standard EN 60870-2-1:1996 has the status of a British Standard ICS 29.020; 33.200 Licensed Copy: sheffieldun

2、sheffieldun, na, Sat Nov 11 09:38:29 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60870-2-1:1996 This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 December 199

3、6 BSI 11-1998 The following BSI references relate to the work on this standard: Committee reference PEL/57 Draft for comment 89/27224 DC ISBN 0 580 26041 0 Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee PEL/57, Power sys

4、tems control and associated communications, upon which the following bodies were represented: BEAMA Metering Association (BMA) Building Automation second edition, published by the International Electrotechnical Commission (IEC). This British Standard supersedes BS 7404-2.1:1991 which is withdrawn. I

5、t implemented HD 546.2.1 S1 which was based on IEC 870-2-1:1987. Other Parts of the IEC 870 series with their corresponding British Standards, which are necessary reading for those developing complete telecontrol systems, are as follows. IEC publicationCorresponding British Standard BS 7404 Telecont

6、rol equipment and systems Part 1 General considerations IEC 870-1-1:1988Section 1.1:1991 General principles IEC 870-1-2:1989Section 1.2:1991 Guide for specifications IEC 870-1-3:1990Section 1.3:1991 Glossary IEC 870-1-4:1994Section 1.4:1995 Guide for basic aspects of telecontrol data transmission an

7、d organization of standards BS 7404-5 and BS 7404-6 IEC 870-3:1989Part 3:1991 Specification for interfaces (electrical characteristics) Implements HD 546.3 S1:1990 IEC 870-4:1990Part 4:1991 Specification for performance Implements HD 546.4 S1:1992 BS EN 60870 Telecontrol equipment and systems Part 5

8、 Transmission protocols IEC 870-5-1:1990Section 5.1:1994 Transmission frame formats IEC 870-5-2:1992Section 5.2:1994 Link transmission procedures IEC 870-5-3:1992Section 5.3:1992 Specification for general structure of application data IEC 870-5-4:1993Section 5.4:1994 Definition and coding of applica

9、tion information elements IEC 870-5-5:1995Section 5.5:1996 Basic application functions IEC 870-5-101:1995Section 5.101:1996 Companion standard for basic telecontrol tasks Part 6 Telecontrol protocols compatible with ISO standards and ITU-T recommendations IEC 870-6-2:1995Section 6.2:1996 Use of basi

10、c standards (OSI layers 1-4) IEC 870-6-601:1994Section 6.601:1995 Functional profile for providing connection-oriented transport service in end system connected via permanent access to a packet switched data network Cross-references Publication referred toCorresponding British Standard HD 472 S1:198

11、9 (IEC 38 (mod) 1983) BS 7697:1993 Nominal voltages for low voltage public electricity supply system Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:38:29 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60870-2-1:1996 BSI 11-1998iii A British Standard does not purport to include all the n

12、ecessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Publication referred toCorresponding British Standard IEC 50(161):1990BS 4727 Glossary of electro

13、technical, power, telecommunication, electronics, lighting and colour termsPart 1 Terms common to power, telecommunications and electronics Group 09:1991 Electromagnetic compatibility HD 588.1 S1:1991BS 923 Guide on high-voltage testing techniques (IEC 60 series)Part 1:1990 General EN 60060-2BS EN 6

14、0060 High-voltage test techniques (IEC 602)Part 2:1995 Measuring systems IEC 664-1:1992BS 7822 Insulation coordination for equipment within low-voltage systems Part 1:1995 Principles, requirements and tests BS EN 61000 Electromagnetic compatibility (EMC) Part 3 Limits EN 61000-3-2:1995 (IEC 1000-3-2

15、:1995) Section 3.2:1995 Limits for harmonic current emissions (equipment input current up to and including 16 A per phase) EN 61000-3-3:1995 (IEC 1000-3-3:1994) Section 3.3:1995 Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current up to and in

16、cluding 16 A. Part 4 Testing and measurement techniques EN 61000-4-1:1994 (IEC 1000-4-1:1992) Section 4.1:1994 Overview of immunity tests. Basic EMC publication EN 61000-4-2:1995 (IEC 1000-4-2:1995) Section 4.2:1995 Electrostatic discharge immunity tests Basic EMC publication EN 61000-4-4:1995 (IEC

17、1000-44:1995) Section 4.4:1995 Electrical fast transient/burst immunity test. Basic EMC publication EN 61000-4-5:1995 (IEC 1000-4-5:1995) Section 4.5:1995 Surge immunity test EN 61000-4-8:1993 (IEC 1000-4-8:1993) Section 4.8:1994 Power frequency magnetic field immunity test. Basic EMC publication EN

18、 61000-4-9:1993 (IEC 1000-4-9:1993) Section 4.9:1994 Pulse magnetic field immunity test. Basic EMC publication EN 61000-4-10:1993 (IEC 1000-4-10:1993) Section 4.10:1994 Damped oscillatory magnetic field immunity test. Basic EMC publication EN 61000-4-11:1994 (IEC 1000-4-11:1994) Section 4.11:1994 Vo

19、ltage dips, short interruptions and voltage variations immunity tests EN 55022:1994 (CISPR 22:1993) BS EN 55022:1995 Limits and methods of measurement of radio disturbance characteristics of information technology equipment Summary of pages This document comprises a front cover, an inside front cove

20、r, pages i to iv, the EN title page, pages 2 to 18, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Licensed Copy: sheffieldun sheffieldun, na

21、, Sat Nov 11 09:38:29 GMT+00:00 2006, Uncontrolled Copy, (c) BSI iv blank Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:38:29 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60870-2-1 January 1996 ICS 29.020; 33.200Supersedes HD 546.2.1 S1:

22、1991 Descriptors: Telecontrol, electric power supply, electromagnetic compatibility, earthing, operating condition, environmental condition, immunity, emission, harmonic content, insulation withstand voltage, data transmission, teleprotection, distribution line carrier system, distribution automatio

23、n system English version Telecontrol equipment and systems Part 2: Operating conditions Section 1: Power supply and electromagnetic compatibility (IEC 870-2-1:1995) Matriels et systmes de tlconduite Partie 2: Conditions de fonctionnement Section 1: Alimentation et compatibilit lectromagntique (CEI 8

24、70-2-1:1995) Fernwirkeinrichtungen und -systeme Teil 2: Betriebsbedingungen Hauptabschnitt 1: Stromversorgung und elektromagnetische Vertrglichkeit (IEC 870-2-1:1995) This European Standard was approved by CENELEC on 1995-11-28. CENELEC members are bound to comply with the CEN/CENELEC Internal Regul

25、ations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. Thi

26、s European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC member

27、s are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Euro

28、pen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1996 Copyright reserved to CENELEC members Ref. No. EN 60870-2-1:1996 E Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:38:29 GMT+00:00 2006, Unco

29、ntrolled Copy, (c) BSI EN 60870-2-1:1996 BSI 11-1998 2 Foreword The text of document 57/217/FDIS, future edition 2 of IEC 870-2-1, prepared by IEC TC 57, Power system control and associated communications, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60870-2-1 on

30、1995-11-28. The following dates were fixed: Annexes designated “normative” are part of the body of the standard. In this standard, annex ZA is normative. Annex ZA has been added by CENELEC. Contents Page Introduction3 1Scope and object3 2Normative references3 3Definitions4 4Power supply5 4.1General5

31、 4.2AC supply5 4.2.1AC voltage tolerances5 4.2.2Frequency tolerances5 4.2.3Harmonic content5 4.3DC supply5 4.3.1DC voltage tolerances6 4.3.2Earthing arrangements for d.c. supply6 4.3.3Voltage ripple of the d.c. supply6 5Electromagnetic compatibility6 5.1General6 5.2Immunity tests6 5.3Acceptance crit

32、eria for immunity tests7 5.4Emission tests7 5.5Protection techniques and installation guidelines7 6Insulation withstand voltages16 Annex ZA (normative) Normative references to international publications with their corresponding European publications17 Page Table 1 AC nominal voltages (Volts r.m.s.:

33、50 Hz or 60 Hz)5 Table 2 AC voltage tolerance classes5 Table 3 Frequency tolerances5 Table 4 Harmonic level classes5 Table 5 DC nominal voltages (V)5 Table 6 DC voltage tolerance classes6 Table 7 DC supply earthing condition classes6 Table 8 Ripple classes6 Table 9 List of immunity tests for electro

34、nic equipment considered by IEC basic publications and applicability to the various components of the systems considered in this section.8 Table 10 List of emission tests for electronic equipment considered by IEC basic publications and applicability to the various components of the systems consider

35、ed in this section9 Table 11 Low frequency disturbances: main parameters for the immunity tests on the various components of the systems, according to the applicability defined in Table 910 Table 12 Conducted transients and HF disturbances: main parameters for the immunity tests on the various compo

36、nents of the systems, according to the applicability defined in Table 911 Table 13 Electrostatic discharge: main parameters for the immunity tests on the various components of the systems, according to the applicability defined in Table 912 Table 14 Magnetic fields: main parameters for the immunity

37、tests on the various components of the systems, according to the applicability defined in Table 913 Table 15 Radiated electromagnetic field: main parameters for the immunity tests on the various components of the systems, according to the applicability defined in Table 914 Table 16 Evaluation criter

38、ia for test results14 Table 17 Conducted and radiated disturbances: main parameters for the emission tests on the various components of the systems, according to the applicability defined in Table 1015 Table 18 Withstand voltage classes16 latest date by which the EN has to be implemented at national

39、 level by publication of an identical national standard or by endorsement (dop) 1996-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 1996-09-01 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:38:29 GMT+00:00 2006, Uncontrolled Copy, (c) B

40、SI EN 60870-2-1:1996 BSI 11-19983 Introduction Telecontrol systems are used for monitoring and control of geographically widespread processes and have to work under a wide range of environmental conditions. To ensure optimal performance under all possible conditions, it is absolutely necessary to es

41、tablish requirements for the apparatus and systems in respect of the different environmental conditions. This section of IEC 870-2 considers all the electrical environmental aspects, i.e. power supply and electromagnetic compatibility (EMC) requirements. The general indications given in IEC Guides1)

42、 106 and 107 have been followed in the preparation of this section, which has to be considered as a product family standard, based on IEC basic publications. 1 Scope and object This section of IEC 870-2 applies to telecontrol equipment and systems with coded bit serial data transmission for monitori

43、ng and control of geographically widespread processes. It is also a reference document for teleprotection equipment and systems and for equipment included in a distribution line carrier (DLC) system supporting a distribution automation system (DAS). This standard specifies, with reference to the var

44、ious components of the systems defined above: 1) the characteristics of the power supply to which these components are connected during the normal operation; 2) the EMC minimum requirements, expressed in terms of immunity and emission test levels. With reference to EMC, the test levels have been sel

45、ected among the classes established by the IEC basic publications on EMC, taking into account the particular environmental conditions under which the various types of equipment considered by this section operate; test procedures, test circuits and acceptance criteria are briefly indicated, making re

46、ference for detailed information to the IEC basic publications on the various subjects; reference is also made to basic publications on protection techniques and installation practices. 2 Normative references The following normative documents contain provisions which, through reference in this text,

47、 constitute provisions of this section of IEC 870-2. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this section of IEC 870-2 are encouraged to investigate the possibility of applying the most recent

48、editions of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. IEC 38:1983, IEC standard voltages. IEC 50(161):1990, International Electrotechnical Vocabulary (IEV) Chapter 161: Electromagnetic compatibility. IEC 60: High-vo

49、ltage test techniques. IEC 664-1:1992, Insulation coordination for equipment within low-voltage systems Part 1: Principles, requirements and tests. IEC 1000-3-2:1995, Electromagnetic compatibility (EMC) Part 3: Limits Section 2: Limits for harmonic current emissions (equipment input current 16 A per phase). IEC 1000-3-3:1994, Electromagnetic compatibility (EMC) Part 3: Limits Section 3: Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current 16 A. IEC 1000-4-1