BS-EN-60966-2-1-2003.pdf

上传人:来看看 文档编号:3743548 上传时间:2019-09-22 格式:PDF 页数:22 大小:351.51KB
返回 下载 相关 举报
BS-EN-60966-2-1-2003.pdf_第1页
第1页 / 共22页
BS-EN-60966-2-1-2003.pdf_第2页
第2页 / 共22页
BS-EN-60966-2-1-2003.pdf_第3页
第3页 / 共22页
BS-EN-60966-2-1-2003.pdf_第4页
第4页 / 共22页
BS-EN-60966-2-1-2003.pdf_第5页
第5页 / 共22页
亲,该文档总共22页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-EN-60966-2-1-2003.pdf》由会员分享,可在线阅读,更多相关《BS-EN-60966-2-1-2003.pdf(22页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 60966-2-1:2003 Radio frequency and coaxial cable assemblies Part 2-1: Sectional specification for flexible coaxial cable assemblies The European Standard EN 60966-2-1:2003 has the status of a British Standard ICS 33.120.10 ? Licensed Copy: sheffieldun sheffieldun, na, Mon Nov

2、13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60966-2-1:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 17 November 2003 BSI 17 November 2003 ISBN 0 580 42920 2 National foreword This British Standard is the official Engli

3、sh language version of EN 60966-2-1:2003. It is identical with IEC 60966-2-1:2003. It supersedes BS EN 60966-2-1:1996 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive compon

4、ents and accessories, to Subcommittee EPL/46/1, Coaxial cables, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referre

5、d to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisio

6、ns of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for

7、 change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 19 and a back cover. The BSI copyright notice displayed in

8、this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 60966-2-1 NORME EUROPENNE EUROPISCHE NORM October 2003

9、CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENELEC - All rights of exploitation in any form and by any means reserved

10、worldwide for CENELEC members. Ref. No. EN 60966-2-1:2003 E ICS 33.120.10 Supersedes EN 60966-2-1:1995 + A1:1997 English version Radio frequency and coaxial cable assemblies Part 2-1: Sectional specification for flexible coaxial cable assemblies (IEC 60966-2-1:2003) Ensembles de cordons coaxiaux et

11、de cordons pour frquences radiolectriques Partie 2-1: Spcification intermdiaire pour cordons coaxiaux souples (CEI 60966-2-1:2003) Konfektionierte Koaxial- und Hochfrequenzkabel Teil 2-1: Rahmenspezifikation fr flexible konfektionierte Koaxialkabel (IEC 60966-2-1:2003) This European Standard was app

12、roved by CENELEC on 2003-10-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nat

13、ional standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own langua

14、ge and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Luxembourg, Malta, Nether

15、lands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60966-2-1:2003 - 2 - Foreword The text of document 46A/545/FDIS, future edition 2 of IEC 60966-2-1, prepared

16、 by SC 46A, Coaxial cables, of IEC TC 46, Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60966-2-1 on 2003-10-01. This European Standard supersedes EN 60966-2-1:1995 +

17、 A1:1997. The major change with respect to EN 60966-2-1:1995 is the reference to the 1999 edition of the generic specification EN 60966-1. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endors

18、ement (dop) 2004-07-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2006-10-01 This sectional specification is to be read with EN 60966-1:1999, Radio frequency and coaxial cable assemblies Part 1: Generic specification - General requirements and test

19、 methods. Annexes designated “normative“ are part of the body of the standard. In this standard, annex ZA is normative. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60966-2-1:2003 was approved by CENELEC as a European Standard without any modifi

20、cation. _ Page 2 EN 6096621:2003 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 60966-2-1 IEC:2003 3 CONTENTS 1 Scope.4 2 Normative references4 3 Definitions 5 4 Design and manufacturing requirements .5 4.1 Cable design and construction .5

21、4.2 Connector design and construction 5 4.3 Outline and interface dimensions .5 5 Workmanship, marking and packaging6 6 Quality assessment.7 7 Test methods General7 8 Electrical tests7 9 Mechanical robustness tests.8 10 Environmental tests 8 11 Specialized test methods 9 12 Test schedules .9 Annex Z

22、A (normative) Normative references to international publications with their corresponding European publications18 Bibliography19 Figure 1 Length definition of cable assemblies6 Figure 2 Example of a cable assembly6 Figure 3 Preferred arrangement for the vibration test8 Table 1 Grouping of tests for

23、specification purposes.10 Table 2 Test schedule11 Page 3 EN 6096621:2003 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 60966-2-1 IEC:2003 4 RADIO FREQUENCY AND COAXIAL CABLE ASSEMBLIES Part 2-1: Sectional specification for flexible coaxial

24、 cable assemblies 1 Scope This part of IEC 60966 is a sectional specification that relates to flexible coaxial cable assemblies operating in the transverse electromagnetic mode (TEM). It establishes uniform requirements for testing the electrical, mechanical and climatic properties of flexible cable

25、 assemblies composed of flexible coaxial cables and coaxial connectors. NOTE 1 The numbering of the clauses is the same as in the generic specification. NOTE 2 For the purpose of this sectional specification, a cable assembly is always regarded as an integral unit. All specifications apply to the fi

26、nished assembly and not to individual and non-assembled parts thereof. NOTE 3 This sectional specification should be supplemented with detail specifications giving additional details as required by the particular application. This application will not necessarily require all tests. 2 Normative refer

27、ences The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60068-2-6: Environmental testing Part 2

28、: Tests Test Fc: Vibration (sinusoidal) IEC 60096-2:1988, Radio-frequency cables Part 2: Relevant cable specifications IEC 60169 (all parts), Radio-frequency connectors IEC 60410:1973, Sampling plans and procedures for inspection by attributesIEC 60966- 1:1999, Radio-frequency and coaxial cable asse

29、mblies Part 1: Generic specification General requirements and test methods IEC 60966-1:1999, Radio frequency and coaxial cable assemblies Part 1: Generic specification General requirements and test methods IEC 61169 (all parts), Radio-frequency connectors IEC 61196 (all parts), Radio-frequency cable

30、s ISO 9000, Quality management systems Fundamentals and vocabulary Page 4 EN 6096621:2003 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 60966-2-1 IEC:2003 5 3 Definitions For the purpose of this document, the definitions given in IEC 60966

31、-1 apply. 4 Design and manufacturing requirements The subclauses of Clause 4 of IEC 60966-1 are replaced by the following. 4.1 Cable design and construction Cables should conform to IEC 60096-2 or IEC 61196. Where cable designs deviating from these publications are required they shall comply with th

32、e requirements of the detail specification. If required, the manufacturer may use additional protective tubing or cable deviating from IEC 61196, in order to comply with the requirements of the detail specification. The materials used in the cable shall be given as engineering information in the det

33、ail specification. 4.2 Connector design and construction Connectors should conform to IEC 61169. Where connector designs deviating from IEC 61169 are required, the interface should conform to the relevant part of IEC 61169 where available and shall comply with the requirements of the detail specific

34、ation. The materials used in the connector shall be given as engineering information in the detail specification. 4.3 Outline and interface dimensions The outline and interface dimensions shall be in accordance with the detail specification of the cable assembly. The length, unless otherwise specifi

35、ed in the detail specification, is defined as between the reference planes of the connectors. In case of right angle connectors the length applies to the axis of the connectors (see Figure 1). If not indicated in the detail specification, the length tolerance shall be 1 % for cables equal to, or lon

36、ger than, 300 mm and 3 mm for cables shorter than 300 mm. Page 5 EN 6096621:2003 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 60966-2-1 IEC:2003 6 Length IEC 2031/03 Figure 1 Length definition of cable assemblies 5 Workmanship, marking an

37、d packaging Clause 5 of IEC 60966-1 applies, except for the following addition. Cable assemblies made in accordance with this sectional specification comprise a section of cable and two connectors. When specified in the detail specification, the assembly may additionally include markers for identifi

38、cation of the assembly and interconnecting ends. End caps and other accessories may also be specified. NOTE Occasionally the cable assembly will comprise only a cable and one connector. Flexible cable Connector 1Connector 2 Marking end 1a Marking end 2aIdentificationa IEC 2032/03 Figure 2 Example of

39、 a cable assembly a When specified. Page 6 EN 6096621:2003 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 60966-2-1 IEC:2003 7 6 Quality assessment Clause 6 of IEC 60966-1 applies. 7 Test methods General Clause 7 of IEC 60966-1 applies. 8 E

40、lectrical tests Clause 8 of IEC 60966-1 is applicable, except as follows. Addition: 8.1 Reflection properties Whilst the parameter return loss (Ar) is preferred, the reflection factor (r) or the VSWR may be specified where Ar = 20 log10 r and VSWR = (1 + r)/ (1 r). Replacement: 8.4 Insertion loss st

41、ability 8.4.1 Object To determine the change of insertion loss when the cable assembly is subjected to bending and twisting (separately). 8.4.2 Procedures 8.4.2.1 Bending The test is to be performed as in 8.6.2.1 of IEC 60966-1 by measurement of the insertion loss (not the phase). 8.4.2.2 Twisting T

42、he test is to be performed as in 8.6.2.2 of IEC 60966-1 by measurement of the insertion loss (not the phase). 8.4.3 Requirements Subclause 8.4.3 of IEC 60966-1 applies. Page 7 EN 6096621:2003 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 6

43、0966-2-1 IEC:2003 8 8.4.4 Information to be given in the detail specification a) Dynamic bending radius of the cable (radius of the mandrel). b) Whether method 1 or 2 is used for the bending test. c) Test frequencies. d) Maximum change of insertion loss. 9 Mechanical robustness tests Clause 9 of IEC

44、 60966-1 applies. 10 Environmental tests Clause 10 of IEC 60966-1 is applicable, except as follows. 10.2 Vibration, bumps and shock 10.2.1 Vibration 10.2.1.1 Procedure The tests shall be carried out in accordance with test Fc of IEC 60068-2-6. The vibration severity shall be chosen from D.2.1 of IEC

45、 60966-1, unless otherwise indicated in the detail specification Vibrating plate Fixed To measuring instrumentation IEC 2033/03 Figure 3 Preferred arrangement for the vibration test The preferred arrangement for the vibration test is described in Figure 3. The cable portion of the cable assembly sha

46、ll be vibrated in each of three perpendicular directions, one of which shall be parallel to the common axis of the connectors. The continuity of the inner and outer conductors shall be monitored during the test. 10.2.1.2 Requirements There shall be no evidence of cracking, breaking or loosening of p

47、arts of a component and there shall be no current discontinuity in excess of 1 s. After the test, the insertion loss and return loss shall not exceed the specified limits. Page 8 EN 6096621:2003 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 06:34:59 GMT+00:00 2006, Uncontrolled Copy, (c) BS

48、I 60966-2-1 IEC:2003 9 10.2.1.3 Information to be given in the detail specification a) Mounting and fixing details of the cable assembly. NOTE The length of the cable in relation to its diameter, between the mounting plate and the fixed plate is an important variable. The fixed plate should be rigid

49、. b) Profile and severity parameters for vibration. These should include duration, frequency and acceleration or displacement. 10.2.2 Bumps This test shall be specified, if necessary, in the detail specification. For the recommended severities, see D.2.2 of IEC 60966-1. 10.2.3 Shock This test shall be specified, if necessary, in the detail specification. For the recommend