BS-EN-61300-2-17-1997 IEC-61300-2-17-1995.pdf

上传人:来看看 文档编号:3743642 上传时间:2019-09-22 格式:PDF 页数:10 大小:278.25KB
返回 下载 相关 举报
BS-EN-61300-2-17-1997 IEC-61300-2-17-1995.pdf_第1页
第1页 / 共10页
BS-EN-61300-2-17-1997 IEC-61300-2-17-1995.pdf_第2页
第2页 / 共10页
BS-EN-61300-2-17-1997 IEC-61300-2-17-1995.pdf_第3页
第3页 / 共10页
BS-EN-61300-2-17-1997 IEC-61300-2-17-1995.pdf_第4页
第4页 / 共10页
BS-EN-61300-2-17-1997 IEC-61300-2-17-1995.pdf_第5页
第5页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-EN-61300-2-17-1997 IEC-61300-2-17-1995.pdf》由会员分享,可在线阅读,更多相关《BS-EN-61300-2-17-1997 IEC-61300-2-17-1995.pdf(10页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 61300-2-17: 1997 IEC 61300-2-17: 1995 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-17: Tests Cold The European Standard EN 61300-2-17:1997 has the status of a British Standard ICS 33.180.20 Licensed Copy: sheffieldun s

2、heffieldun, na, Sat Nov 11 12:37:11 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61300-2-17:1997 This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 October 1997

3、 BSI 09-1999 ISBN 0 580 28567 7 National foreword This British Standard is the English language version of EN 61300-2-17:1997. It is identical with IEC 61300-2-17:1995. The UK participation in its preparation was entrusted by Technical Committee EPL/86, Fibre optics, to Subcommittee EPL/86/2, Interc

4、onnecting devices and passive components, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international

5、 and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 6

6、0027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references Attention is drawn to the fact that CEN and CENELEC Standards normally include an annex which lists normative references to internation

7、al publications with their corresponding or European publications. The British Standards which implement these international or European publications may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility

8、 of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligation

9、s. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendm

10、ent table on the inside front cover. Amendments issued since publication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:37:11 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61300-2-17:1997 BSI 09-1999i Contents Page National forewordInside front cover Foreword 2 Tex

11、t of EN 61300-2-173 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:37:11 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ii blank Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:37:11 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 6130

12、0-2-17 July 1997 ICS 33.180.20 English version Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-17: Tests Cold (IEC 61300-2-17:1995) Dispositifs dinterconnexion et composants passifs fibres optiques Mthodes fondamentales dessais et de mesures Pa

13、rtie 2-17: Essais Froid (CEI 61300-2-17:1995) Lichtwellenleiter Verbindungselemente und passive Bauteile Grundlegende Prf- und Meverfahren Teil 2-17: Prfungen: Klte (IEC 61300-2-17:1995) This European Standard was approved by CENELEC on 1997-07-01. CENELEC members are bound to comply with the CEN/CE

14、NELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any

15、 CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official vers

16、ions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standa

17、rdization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1997 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-17:1997

18、 E Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:37:11 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 61300-2-17:1997 2 BSI 09-1999 Foreword The text of the International Standard IEC 61300-2-17:1995, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC T

19、C 86, Fibre optics, was submitted to the formal vote and was approved by CENELEC as EN 61300-2-17 on 1997-07-01 without any modification. The following dates were fixed: Annexes designated “normative” are part of the body of the standard. In this standard, Annex ZA is normative. Annex ZA has been ad

20、ded by CENELEC. Endorsement notice The text of the International Standard IEC 61300-2-17:1995 was approved by CENELEC as a European Standard without any modification. Contents Page Foreword2 1General3 1.1Scope and object3 1.2General description3 1.3Normative references3 2Apparatus3 3Procedure3 4Seve

21、rity4 5Details to be specified4 Annex ZA (normative) Normative references to international publications with their corresponding European publicationsInside back cover latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorseme

22、nt(dop) 1998-06-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 1998-06-01 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:37:11 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 61300-2-17:1997 BSI 09-19993 1 General 1.1 Scope and object The pu

23、rpose of this part of IEC 1300 is to determine the suitability of a fibre optic device to withstand the environmental condition of extended low temperature (cold) which may occur in actual use, storage and/or transport. The procedure does not permit the assessment of the ability of these devices to

24、withstand or operate during temperature variations; in this case, IEC 1300-2-22 would be used. 1.2 General description This procedure is conducted in accordance with IEC 68-2-1, test Ab. The specimen is placed in a chamber at ambient temperature. The temperature is then lowered to test temperature a

25、t a rate not to exceed 1 C/min averaged over a maximum period of 5 min, and maintained at that temperature for the specified duration, The chamber temperature is then raised to ambient and the specimen is allowed to attain ambient temperature before final measurements are made. 1.3 Normative referen

26、ces The following normative documents contains provisions which, through reference in this text, constitute provisions of this part of IEC 1300. At the time of publication, the edition indicated were valid. All normative documents are subject to revision, and parties to agreements based on this part

27、 of IEC 1300 are encouraged to investigate the possibility of applying the most recent edition of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. IEC 68-2-1:1990, Environmental testing Part 2: Tests Test A: Cold. IEC 1300

28、-2-22:1995, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2: Tests Change of temperature. 2 Apparatus 2.1 Chamber The apparatus consists of an environmental chamber in accordance with IEC 68-2-1, test Ab. The chamber shall be capable of housing

29、 the specimen and of allowing access for measurement during conditioning, if required. It shall also be capable of maintaining the specified temperature and tolerance. Forced air circulation may be used to maintain homogeneous conditions. Care shall be taken to ensure that the specimen is not direct

30、ly exposed to the heating or cooling elements. 2.2 Other apparatus Additional apparatus may be necessary to perform the measurements specified by the detail specification. 3 Procedure Conduct the procedure in accordance with IEC 68-2-1, test Ab. 3.1 Preconditioning If specified, precondition the spe

31、cimen as required by the detail specification. 3.2 Initial measurements If specified, take initial examinations and measurements as required by the detail specification. 3.3 Conditioning 3.3.1 Stabilize the chamber and the specimen to standard atmospheric conditions. Place the specimen in the chambe

32、r in its normal operating position including hook-ups to peripheral equipment (when required). 3.3.2 Adjust the chamber temperature to the specified severity. The. rate of change of temperature shall not exceed 1 C/min, averaged over a maximum period of 5 min. Allow the specimen to reach temperature

33、 stability and maintain the temperature for the duration specified. 3.3.3 At the completion of the test, allow the specimen to remain in the chamber while the temperature is gradually raised to standard atmospheric conditions. The rate of change of temperature shall not exceed 1 C/min, averaged over

34、 a maximum period of 5 minutes. The detail specification may call for measurements during conditioning. If required, the detail specification shall specify the measurements to be taken and when to take them. Do not remove the specimen(s) from the chamber when taking these measurements. 3.4 Recovery

35、Remove water droplets by shaking the specimen or by using a blast of air at laboratory temperatures for a short time. Allow the specimen to remain under standard atmospheric conditions for a period of greater than 1 h. The detail specification may call for measurements during recovery. If required,

36、the detail specification shall specify the measurements to be taken and when to take them. 3.5 Final measurements Take final measurements as required by the detail specification. Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:37:11 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 61300-2-17:

37、1997 4 BSI 09-1999 4 Severity The severity consists of the combination of the temperature and duration of exposure. Temperature deviation shall be less than 3 C. The following preferred severities are non-mandatory severities which may be specified for this procedure: 5 Details to be specified The f

38、ollowing details, as applicable, shall be specified in the detail specification: Temperature Duration of exposure Specimen optically functioning or non-functioning Specimen mated or unmated Pre-conditioning procedure Recovery procedure Initial examinations and measurements and performance requiremen

39、ts Examinations and measurements during test and performance requirements Final examinations and measurements and performance requirements Deviations from test procedure Additional pass/fail criteria Temperature C Duration h 652 5516 4024 2572 1096 5240 + 5500 Licensed Copy: sheffieldun sheffieldun,

40、 na, Sat Nov 11 12:37:11 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 61300-2-17:1997 BSI 09-1999 Annex ZA (normative) Normative references to international publications with their corresponding European publications This European Standard incorporates by dated or undated reference, provisions from

41、 other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendmen

42、t or revision. For undated references the latest edition of the publication referred to applies (including amendments). NOTEWhen an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. PublicationYearTitleEN/HDYear IEC 60068-2-11990Envi

43、ronmental testing Part 2: Tests Test A: Cold EN 60068-2-11993 IEC 61300-2-221995Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-22: Tests Change of temperature EN 61300-2-221997 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 12:37:11 GM

44、T+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61300-2-17: 1997 IEC 61300-2-17: 1995 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the

45、international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and servic

46、es. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: 020 8996 9000. Fax: 020 8996 7400. BSI offers members an indiv

47、idual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001. In respons

48、e to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through i

49、ts Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: 020 8996 7111. Fax: 020 8996 7048. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: 020 8996 7002. Fa

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1