BS-EN-60939-2-2005.pdf

上传人:来看看 文档编号:3743690 上传时间:2019-09-22 格式:PDF 页数:50 大小:803.99KB
返回 下载 相关 举报
BS-EN-60939-2-2005.pdf_第1页
第1页 / 共50页
BS-EN-60939-2-2005.pdf_第2页
第2页 / 共50页
BS-EN-60939-2-2005.pdf_第3页
第3页 / 共50页
BS-EN-60939-2-2005.pdf_第4页
第4页 / 共50页
BS-EN-60939-2-2005.pdf_第5页
第5页 / 共50页
亲,该文档总共50页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-EN-60939-2-2005.pdf》由会员分享,可在线阅读,更多相关《BS-EN-60939-2-2005.pdf(50页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 60939-2:2005 Incorporating Corrigendum No. 1 Passive filter units for electromagnetic interference suppression Part 2: Sectional specification: Passive filter units for which safety tests are appropriate Test methods and general requirements The European Standard EN 60939-2:20

2、05 has the status of a British Standard ICS 31.160 ? Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60939-2:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 19 August 2005

3、BSI 2006 ISBN 0 580 46032 0 National foreword This British Standard is the official English language version of EN 60939-2:2005. It is identical with IEC 60939-2:2005, including corrigendum November 2005. It supersedes BS EN 133200:1999 which will be withdrawn on 1 March 2008. The start and finish o

4、f text introduced or altered by corrigendum is indicated in the text by tags . Tags indicating changes to IEC text carry the number of the corrigendum. For example, text altered by IEC corrigendum 1 is indicated in the text by . The UK participation in its preparation was entrusted to Technical Comm

5、ittee EPL/40X, Capacitors and resistors for electronic equipment, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred

6、 to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provision

7、s of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or

8、proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 46, an inside back cover and a back cover. The

9、 BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments 16255 Corrigendum No. 1 31 August 2006 See national foreword Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontr

10、olled Copy, (c) BSI EUROPEAN STANDARD EN 60939-2 NORME EUROPENNE EUROPISCHE NORM April 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 10

11、50 Brussels ICS 31.160 Supersedes EN 133200:1999 English version Passive filter units for electromagnetic interference suppression Part 2: Sectional specification: Passive filter units for which safety tests are appropriate Test methods and general requirements (IEC 60939-2:2005) Filtres passifs dan

12、tiparasitage Partie 2: Spcification intermdiaire: Filtres passifs pour lesquels des essais de scurit sont appropris Mthodes dessai et rgles gnrales (CEI 60939-2:2005) Passive Filter fr die Unterdrckung von elektromagnetischen Strungen Teil 2: Rahmenspezifikation: Filter, fr die Sicherheitsprfungen v

13、orgeschrieben sind Prfverfahren und allgemeine Anforderungen (IEC 60939-2:2005) This European Standard was approved by CENELEC on 2005-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a

14、 national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A vers

15、ion in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Repub

16、lic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. 2005 CENELEC - All rights of exploitation in any form and by any

17、means reserved worldwide for CENELEC members. Ref. No. EN 60939-2:2005 E Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60939-2:2005 - 2 - Foreword The text of document 40/1510/FDIS, future edition 2 of IEC 60939-2, prepared by IEC TC 40

18、, Capacitors and resistors for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60939-2 on 2005-03-01. This European Standard supersedes EN 133200:1999. The following dates were fixed: latest date by which the EN has to be implemented at national

19、 level by publication of an identical national standard or by endorsement (dop) 2005-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2008-03-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 609

20、39-2:2005 was approved by CENELEC as a European Standard without any modification. _ Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 3 EN 60939-2:2005 CONTENTS 1 General7 1.1 Scope7 1.2 Normative references 7 1.3 Information to be given in a

21、 detail specification 8 1.3.1 General .8 1.3.2 Outline drawing and dimensions.8 1.3.3 Mounting8 1.3.4 Ratings and characteristics 9 1.3.5 Marking .9 1.4 Terms and definitions 9 1.5 Marking.10 1.5.1 See 2.4 of IEC 60939-1 with the following details:.10 1.5.2 The filter shall be clearly marked with th

22、e information in 1.5.1 a), b), c), d) and f), and also e) if this is not implied by b). .11 1.5.3 The package containing the filter(s) shall be clearly marked with all the information listed in 1.5.1. 11 1.5.4 Any additional marking shall be so applied that no confusion can arise11 2 Preferred ratin

23、gs and characteristics.11 2.1 Preferred characteristics11 2.1.1 General .11 2.1.2 Preferred climatic categories11 2.2 Preferred values of ratings.11 2.2.1 Rated voltage (UR).11 2.2.2 Category voltage (UC)11 2.2.3 Rated temperature .12 2.2.4 Passive flammability 12 3 Quality assessment procedures 12

24、3.1 Primary stage of manufacture 12 3.2 Structurally similar filters .12 3.3 Certified records of released lots12 3.4 Approval testing.12 3.4.1 Safety tests only approval 12 3.4.2 Qualification approval 12 3.4.3 Sampling .13 3.4.4 Tests .13 3.5 Quality conformance inspection .14 3.5.1 General .14 3.

25、5.2 Formation of inspection lots .14 3.5.3 Test schedule 15 3.5.4 Delayed delivery 15 4 Test and measurement procedures .19 4.1 Earth inductors incorporated in filters.19 4.2 Capacitance and tan measurements19 4.3 Visual examination and check of dimensions19 4.3.1 General .19 4.3.2 Creepage distance

26、s and clearances .19 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60939-2:2005 4 4.4 Voltage proof.20 4.4.1 Test circuit for d.c. tests.20 4.4.2 Applied voltage 20 4.4.3 Requirements 21 4.5 Insulation resistance21 4.5.1 Temperature cor

27、rection21 4.5.2 Requirements 21 4.6 DC line resistance or voltage drop at rated current .21 4.6.1 DC line resistance21 4.6.2 Voltage drop at rated current22 4.7 Insertion loss.22 4.8 Discharge resistance .22 4.9 Robustness of terminations23 4.10 Resistance to soldering heat23 4.10.1 Test conditions

28、23 4.10.2 Intermediate inspection, measurements and requirements 23 4.11 Solderability 23 4.11.1 Test conditions 23 4.11.2 Requirements 23 4.12 Rapid change of temperature.23 4.12.1 Intermediate inspection 24 4.13 Vibration24 4.13.1 Test conditions 24 4.13.2 Intermediate inspection 24 4.14 Bump24 4.

29、14.1 Test conditions 24 4.14.2 Intermediate inspection, measurements and requirements 24 4.15 Shock.25 4.15.1 Test conditions 25 4.15.2 Intermediate inspection, measurements and requirements 25 4.16 Container sealing 25 4.16.1 Test conditions 25 4.16.2 Requirements 25 4.17 Climatic sequence .26 4.17

30、.1 Initial measurements26 4.17.2 Dry heat26 4.17.3 Damp heat, cyclic, first cycle26 4.17.4 Cold26 4.17.5 Low air pressure 26 4.17.6 Damp heat, cyclic, remaining cycles .26 4.17.7 Final inspection, measurements and requirements26 4.18 Damp heat, steady state 27 4.18.1 Test conditions 27 4.18.2 Final

31、inspection, measurements and requirements27 4.19 Temperature rise .27 4.19.1 Test method.28 4.19.2 Requirements 29 4.20 Impulse voltage .29 4.20.1 Initial measurements29 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 5 EN 60939-2:2005 4.20.

32、2 Test conditions 29 4.20.3 Requirements 30 4.21 Endurance.30 4.21.1 Test conditions current test .30 4.21.2 Test conditions voltage test, terminations/case 31 4.21.3 Test conditions voltage test between terminations31 4.21.4 Test conditions combined voltage/current tests32 4.21.5 Final inspection,

33、measurements and requirements32 4.22 Charge and discharge32 4.22.1 Initial measurements33 4.22.2 Test conditions 33 4.22.3 Final measurements and requirements .33 4.23 Passive flammability 33 4.24 Current overload33 4.25 Solvent resistance of the marking 33 4.26 Component solvent resistance .34 4.27

34、 Active flammability.34 Annex A (normative) Test schedule for qualification approval Assessment level D / DZ35 Annex B (normative) Test schedule for safety requirements only39 Annex C (normative) Circuit for the impulse voltage test .41 Annex D (normative) Circuit for the endurance test.43 Annex E (

35、normative) Declaration of design.44 Annex ZA (normative) Normative references to international publications with their corresponding European publications45 Figure 1 Impulse wave form .30 Figure C.1 Impulse voltage test circuit41 Table 1 Classification of class X capacitors 9 Table 2 Classification

36、of class Y capacitors 10 Table 3 Tests concerning safety requirements only.15 Table 4 Sampling plan Safety and performance tests qualification approval Assessment level D / DZ.16 Table 5 Lot-by-lot-tests Assessment level D / DZ.17 Table 6 Lot-by-lot test Safety tests only approval.17 Table 7 Periodi

37、c tests Assessment level D / DZ .18 Table 8 Creepage distances and clearances.19 Table 9 Voltage proof.20 Table 10 Insulation resistance21 Table 11 Preferred severities .25 Table 12 Measurements and requirements after charge and discharge32 Table A.1 Test schedule for qualification approval Assessme

38、nt level D / DZ.35 Table B.1 Test schedule for safety requirements only .39 Table C.1 Values of CX, CT, RP, RS, CP.41 Table C.2 Values and tolerances of Cx, tr, td.42 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI blank Licensed Copy: sheff

39、ieldun sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 7 EN 60939-2:2005 PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION Part 2: Sectional specification Passive filter units for which safety tests are appropriate Test methods and general requirements

40、 1 General 1.1 Scope This Sectional specification applies to passive filter units for electromagnetic interference suppression which fall within the scope of the Generic Specification IEC 60939-1. The scope of this Sectional specification is restricted to passive filter units for which safety tests

41、are appropriate. This implies that filters specified according to this Sectional specification will either be connected to mains supplies, when compliance with the mandatory tests of Table 3 is necessary, or used in other circuit positions where the equipment specification prescribes that some or al

42、l of these safety tests are required. This Sectional specification applies to passive filter units which will be connected to an a.c. mains or other supply with a nominal voltage not exceeding 1 000 V a.c., with a nominal frequency not exceeding 400 Hz, or 1 000 V d.c. 1.2 Normative references The f

43、ollowing referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE Components other than inductors and capacitors in

44、 the filter unit should fulfil requirements in the relevant IEC Standard. IEC 60060-1, High-voltage test techniques Part 1: General definitions and test requirements IEC 60062, Marking codes for resistors and capacitors IEC 60068-1, Environmental testing Part 1: General and guidance IEC 60068-2-17,

45、Basic environmental testing procedures Part 2: Tests Test Q: Sealing IEC 60085, Thermal evaluation and classification of electrical insulation IEC 60335-1, Safety of household and similar electrical appliances Part 1: General requirements IEC 60384-9, Fixed capacitors for use in electronic equipment

46、 Part 9: Sectional specification: Fixed capacitors of ceramic dielectric, Class 2 IEC 60384-14, Fixed capacitors for use in electronic equipment Part 14: Sectional specification: Fixed capacitors for electromagnetic interference suppression and connection to the supply mains Licensed Copy: sheffield

47、un sheffieldun, na, Sat Nov 11 02:13:26 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60939-2:2005 8 IEC 60664 (all parts), Insulation coordination for equipment within low-voltage systems IEC 60938-1, Fixed inductors for electromagnetic interference suppression Part 1: Generic specification IEC 609

48、39-1, Passive filter units for electromagnetic interference suppression Part 1: Generic specification IEC 60940, Guidance information on the application of capacitors, resistors, inductors and complete filter units for radio interference suppression IEC 61140, Protection against electric shock Commo

49、n aspects for installation and equipment 1.3 Information to be given in a detail specification 1.3.1 General The detail specifications shall be derived from the relevant blank detail specification. Detail specifications shall not specify requirements inferior to those of the generic, sectional or blank detail specification. When more severe req