1、BRITISH STANDARD BS EN 61347-2-3:2001 IEC 61347-2-3:2000 Incorporating Amendment No. 1, Amendment No. 2 and Corrigendum No. 1 Lamp controlgear Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps The European Standard EN 61347-2-3:2001, with the incorporation

2、 of amendment A1:2004 and amendment A2:2006, has the status of a British Standard ICS 29.140.99 ? Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 15:25:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 61347-2-3:2001 This British Standard, having been prepared under the direction of the Ele

3、ctrotechnical Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15 May 2001 BSI 2006 ISBN 0 580 37406 8 National foreword This British Standard is the official English language version of EN 61347-2-3:2001, including amendment A1:2004, amendment

4、A2:2006 and Corrigendum July 2003. It is identical with IEC 61347-2-3:2000 including amendment 1:2004 and amendment 2:2006. Together with BS EN 61347-1:2001 it supersedes BS EN 60928:1995 which will be withdrawn on 01 December 2006. The start and finish of text introduced or altered by amendment is

5、indicated in the text by tags !“. Tags indicating changes to IEC text carry the number of the IEC amendment. For example, text altered by IEC amendment 1 is indicated in the text by !“. The UK participation in its preparation was entrusted by Technical Committee CPL/34, Lamps and related equipment,

6、to Subcommittee CPL/34/3, Auxiliaries for lamps, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this do

7、cument may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contrac

8、t. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for

9、change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 33 and a back cover. The BSI copyright notice displayed in this

10、document indicates when the document was last issued. Sidelining in this document indicates the most recent changes by amendment. Amendments issued since publication Amd. No. DateComments 14669 Corrigendum No. 1 26 September 2003 Change to date of withdrawal in EN foreword 1543112 November 2004See n

11、ational foreword 1632731 May 2006See national foreword Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 15:25:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61347-2-3 January 2001 + A1 September 2004 + A2 February 2006 ICS 29.140.99Sup;ersede

12、s EN 60928:1995 Incorporating Corrigendum July 2003 English version Lamp controlgear Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps (includes amendments A1:2004 and A2:2006) (IEC 61347-2-3:2000 + A1:2004 + A2:2006) Appareillages de lampes Partie 2-3: Pr

13、escriptions particulires pour les ballasts lectroniques aliments en courant alternatif pour lampes fluorescentes (inclut les amendements A1:2004 et A2:2006) (CEI 61347-2-3:2000 + A1:2004 + A2:2006) Gerte fr Lampen Teil 2-3: Besondere Anforderungen an wechselstromversorgte elektronische Vorschaltgert

14、e fr Leuchtstofflampen (enthlt nderungen A1:2004 und A2:2006) (IEC 61347-2-3:2000 + A1:2004 + A2:2006) This amendment A2 modifies the European Standard EN 61347-2-3:2001; it was approved by CENELEC on 2000-11-01; amendment A1 was approved by CENELEC on 2006-02-01. CENELEC members are bound to comply

15、 with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat o

16、r to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the offic

17、ial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania,

18、Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 2001 CENELE

19、C All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61347-2-3:2001 + A1:2004 + A2:2006 E Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 15:25:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI Foreword The text of document 34C/500/FDIS, fu

20、ture edition 1 of IEC 61347-2-3 prepared by SC 34C, Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61347-2-3 on 2000-11-01. This European Standard, together with EN 61347-1, supersedes EN 60928:1995.

21、The following dates were fixed: This standard shall be used in conjunction with EN 61347-1:2001. NOTE In this standard, the following print types are used: requirements : in roman type; test specifications: in italic type; notes: in smaller type. Annexes designated normative are part of the body of

22、the standard. In this standard, Annexes A to J and ZA are normative. Annex ZA has been added by CENELEC. Endorsement notice The text of the International Standard IEC 61347-2-3:2000 was approved by CENELEC as a European Standard without any modification. Foreword to amendment A1 The text of document

23、 34C/636/FDIS, future amendment 1 to IEC 61347-2-3:2000, prepared by SC 34C, Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to EN 61347-2-3:2001 on 2004-09-01. The following dates were fixed

24、: Endorsement notice The text of amendment 1:2004 to the International Standard IEC 61347-2-3:2000 was approved by CENELEC as an amendment to the European Standard without any modification. Foreword to amendment A2 The text of document 34C/707/FDIS, future amendment 2 to IEC 61347-2-3:2000, prepared

25、 by SC 34C, Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC- CENELEC parallel vote and was approved by CENELEC as amendment A2 to EN 61347-2-3:2001 on 2006-02-01. The following dates were fixed: latest date by which the amendment has to be implemented at na

26、tional level by publication of an identical national standard or by endorsement(dop) 2006-11-01 latest date by which the national standards conflicting with the amendment have to be withdrawn(dow) 2009-02-01 Endorsement notice The text of amendment 2:2006 to the International Standard IEC 61347-2-3:

27、2000 was approved by CENELEC as an amendment to the European Standard without any modification. latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2001-08-01 latest date by which the national standards conflict

28、ing with the EN have to be withdrawn(dow) 2006-12-01 latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2005-06-01 latest date by which the national standards conflicting with the amendment have to be wi

29、thdrawn(dow) 2007-09-01 EN 6134723:2001 Page 2 Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 15:25:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI CONTENTS FOREWORD.2 INTRODUCTION5 1 Scope. 6 2 Normative references . 6 3 Definitions 6 4 General requirements. 7 5 General notes on tests . 7 6 C

30、lassification 8 7 Marking 8 7.1 Mandatory markings 8 7.2 Information to be provided, if applicable 8 8 Protection against accidental contact with live parts . 8 9 Terminals . 8 10 Provisions for earthing 8 11 Moisture resistance and insulation 9 12 Electric strength . 9 13 Thermal endurance test for

31、 windings 9 14 Fault conditions 9 15 Protection of associated components . 9 16 Abnormal conditions.10 17 Behaviour of the ballast at end of lamp life .11 17.1 End of lamp life effects11 17.2 Asymmetric pulse test .12 17.3 Asymmetric power test 14 17.4 Open filament test .15 18 Construction.19 19 Cr

32、eepage distances and clearances .19 20 Screws, current-carrying parts and connections19 21 Resistance to heat, fire and tracking.19 22 Resistance to corrosion 19 Annexes .24 Figure 1a Circuit for testing20 Figure 1b Recovery time trr of the diode 20 Figure 1 Rectifying effect test 20 Figure 2 Limits

33、 for capacitive leakage current of HF-operated fluorescent lamps 23 Page 3 EN 6134723:2001 Bibliography .33 Figure 2a Range 10 ms 100 ms 21 Figure 2b Range 100 ms 1 000 ms 22 Figure 2c Range 1 000 ms 10 000 ms 23 Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 15:25:50 GMT+00:00 2006, Uncontr

34、olled Copy, (c) BSI Figure 5a Open filament test circuit; electrode (1) check18 Figure 5b Open filament test circuit; electrode (2) check18 Figure 5c Detection of lamp current .18 Figure 5 Open filament test circuits18 Figure I.1 Test arrangement.26 Table 1 Relation between r.m.s. working voltage an

35、d maximum peak voltage 9 Table J.1 Pulse voltages30 Table K.1 Material specification .31 Table K.2 Transformer specification.31 Page 4 EN 6134723:2001 Figure 3 Asymmetric pulse test circuit13 Figure 4 Asymmetric power detection circuit 15 Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 15:25:

36、50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI INTRODUCTION This first edition of IEC 61347-2-3, published in conjunction with IEC 61347-1, represents an editorial review of IEC 60928. The formatting into separately published parts provides for ease of future amendments and revisions. Additional requ

37、irements will be added as and when a need for them is recognized. This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of IEC 61347-1, specify the extent to which such a clause is applicable and the order in which the tests are to be performed; they also include

38、 additional requirements, as necessary. All parts which make up IEC 61347-2 are intended to be self-contained and, therefore, do not include references to each other. However, for the case of emergency lighting lamp controlgear, some cross-referencing has been necessary. Where the requirements of an

39、y of the clauses of IEC 61347-1 are referred to in this standard by the phrase ”The requirements of clause n of IEC 61347-1 apply”, this phrase is interpreted as meaning that all requirements of the clause in question of part 1 apply, except any which are clearly inapplicable to the specific type of

40、 lamp controlgear covered by this particular part of IEC 61347-2. Page 5 EN 6134723:2001 Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 15:25:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI LAMP CONTROLGEAR Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent

41、 lamps 1 Scope This part of IEC 61347 specifies particular safety requirements for electronic ballasts for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, a

42、nd other fluorescent lamps for high-frequency operation. Particular requirements for electronic ballasts with means of protection against overheating are given in annex C. Particular requirements for a.c./d.c. supplied electronic ballasts for maintained emergency lighting are given in annex J. Perfo

43、rmance requirements are the subject of IEC 60929. 2 Normative references For the purpose of this part of IEC 61347, the normative references given in clause 2 of IEC 61347-1 which are mentioned in this standard apply, together with the following normative references. IEC 60598-2-22, Luminaires Part

44、2-22: Particular requirements Luminaires for emergency lighting IEC 61347-1, Lamp controlgear Part 1: General and safety requirements IEC 61347-2-7, Lamp controlgear Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency lighting1) 3 Definitions For the purpose of this

45、 part of IEC 61347, the definitions of clause 3 of IEC 61347-1 apply, together with the following: 3.1 a.c. supplied electronic ballast mains-supplied a.c. to a.c. invertor including stabilizing elements for starting and operating 1) To be published. Page 6 EN 6134723:2001 one or more #fluorescent l

46、amps$, generally at high frequency. Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 15:25:50 GMT+00:00 2006, Uncontrolled Copy, (c) BSI maximum value of lamp power (of a controllable ballast) lamp power (light output) which complies with 8.1 of IEC 60929, unless otherwise declared by the manu

47、facturer or responsible vendor maximum allowed peak voltage highest permitted peak voltage across any insulation under open-circuit condition and any normal and abnormal operating conditions. The maximum peak voltage is related to the declared r.m.s. working voltage; see table 1 minimum value of lam

48、p power (of a controllable ballast) lowest percentage of the lamp power defined in 3.3 declared by the manufacturer or responsible vendor a.c./d.c. supplied electronic ballast for maintained emergency lighting cathode dummy resistor cathode substitution resistor as specified on the relevant lamp dat

49、a sheet of IEC 60081 or IEC 60901 or as declared by the relevant lamp manufacturer or by the responsible vendor 4 General requirements The requirements of clause 4 of IEC 61347-1 apply, together with the following additional requirement: Page 7 EN 6134723:2001 #3.2$ #3.3 $ #3.4$ #3.5$ Mains/battery-supplied a.c./d.c. to a.c. invertor including stabilizing elements for starting and operating one o