BS-EN-60728-7-3-2005.pdf

上传人:小小飞 文档编号:3744342 上传时间:2019-09-22 格式:PDF 页数:32 大小:473.01KB
返回 下载 相关 举报
BS-EN-60728-7-3-2005.pdf_第1页
第1页 / 共32页
BS-EN-60728-7-3-2005.pdf_第2页
第2页 / 共32页
BS-EN-60728-7-3-2005.pdf_第3页
第3页 / 共32页
BS-EN-60728-7-3-2005.pdf_第4页
第4页 / 共32页
BS-EN-60728-7-3-2005.pdf_第5页
第5页 / 共32页
亲,该文档总共32页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-EN-60728-7-3-2005.pdf》由会员分享,可在线阅读,更多相关《BS-EN-60728-7-3-2005.pdf(32页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS EN 60728-7-3:2005 Cable networks for television signals, sound signals and interactive services Part 7-3: Hybrid Fibre Coax Outside Plant Status Monitoring Power supply to Transponder Interface Bus (PSTIB) Specification The European Standard EN 60728-7-3:2005 has the status of a

2、British Standard ICS 33.100.20; 33.160; 33.040 ? Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 07:42:24 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60728-7-3:2005 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 22 March 2005 BSI

3、 22 March 2005 ISBN 0 580 45596 3 National foreword This British Standard is the official English language version of EN 60728-7-3:2005. It is identical with IEC 60728-7-3:2003. The UK participation in its preparation was entrusted to Technical Committee EPL/100, Audio, video and multimedia systems

4、and equipment, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalo

5、gue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its corr

6、ect application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests inf

7、ormed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 29 and a back cover. The BSI copyright notice displayed in this document indicates when the docum

8、ent was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 07:42:24 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 60728-7-3 NORME EUROPENNE EUROPISCHE NORM February 2005 CENELEC European Committee for Electr

9、otechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. N

10、o. EN 60728-7-3:2005 E ICS 33.100.20; 33.160; 33.040 English version Cable networks for television signals, sound signals and interactive services Part 7-3: Hybrid Fibre Coax Outside Plant Status Monitoring Power supply to Transponder Interface Bus (PSTIB) Specification (IEC 60728-7-3:2003) Rseaux d

11、e distribution par cbles pour signaux de tlvision, signaux de radiodiffusion sonore et services interactifs Partie 7-3: Surveillance de ltat des installations extrieures des rseaux hybrides fibre optique et cble coaxial Spcification de lalimentation du bus dinterface du rpteur (CEI 60728-7-3:2003) K

12、abelnetze fr Fernsehsignale, Tonsignale und interaktive Dienste Teil 7-3: Zustandsberwachung Hybrid-Faser-Koax-Netze (HFC) Festlegung Schnittstellenbus von Fernspeise-Stromversorgung zu Transponder (PSTIB) (IEC 60728-7-3:2003) This European Standard was approved by CENELEC on 2004-12-01. CENELEC mem

13、bers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applicat

14、ion to the Central Secretariat or to any CENELEC member. This European Standard exists in one official version (English). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status

15、 as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slov

16、akia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 07:42:24 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 62708-7-3:0250 - - 2 Foreword The text of the International Standard IEC 60728-7-3:2003, prepared by technical area 5: Cable ne

17、tworks for television signals, sound signals and interactive services, of IEC TC 100, Audio, video and multimedia systems and equipment, was submitted to the formal vote and was approved by CENELEC as EN 60728-7-3 on 2004-12-01 without any modification. The following dates were fixed: latest date by

18、 which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2005-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-12-01 Annex ZA has been added by CENELEC. _ Endorsement notice

19、 The text of the International Standard IEC 60728-7-3:2003 was approved by CENELEC as a European Standard without any modification. _ Page 2 EN 6072873:2005 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 07:42:24 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 2 067-82-73 IE:C0023()E CONTENTS FOR

20、EWODR. 4 INTRODUCTION.5 1 Scope.6 2 Normative references .7 3 Terms, definitions and abbreviations 7 3.1 Terms and definitions7 3.7 Abbreviations 7 4 Reference architecture forward and return channel specifications 8 5 Power supply to transponder interface bus specification overview 8 5.1 Interface

21、compliance .9 5.2 Implementation compliance .9 5.3 Revision control 9 6 Power supply to transponder interface bus Physical layer specification .9 6.1 Interface requirements 9 6.2 Interface diagram 11 7 Power supply to transponder interface bus Data link layer specification.12 7.1 DLL packet structur

22、e .12 7.2 DLE sequence.14 7.3 Interface timing .14 7.4 DLL datagrams16 Figure 1 Reference architecture diagram .8 Figure 2 Sample PSTIB RS-485 interface 12 Figure 3 DLL packet structure13 Figure 4 PSTIB Data and timing diagram .15 Figure 5 DLL datagram structure16 Figure 6 Battery string naming conv

23、entions26 Table 1 Transponder type classifications .6 Table 2 RJ-45 Connector pin assignment.10 Table 3 Sample PSTIB RS-485 interface Reference signals12 Table 4 Generic DLL packet structure13 Table 5 Reserved destination address ranges13 Table 6 PSTIB Timing specifications15 Table 7 Generic DLL dat

24、agram structure17 Table 8 DLL datagrams18 Table 9 Command: Get_Configuration datagram19 Table 10 Response: Get_Configuration datagram 19 Table 11 Response: Get_Configuration datagram1 variable binding (General)19 Table 12 Response: Get_Configuration datagram1,2 variable binding (Power supply) .20 Ta

25、ble 13 Response: Get_Configuration Datagram1 Variable Binding (Generator).23 Table 14 Command: Get_Power_Supply_Data datagram .24 Page 3 EN 6072873:2005 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 07:42:24 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 067-82-73 IEC:20(30E) 3 Table 15 Respons

26、e: Get_Power_Supply_Data datagram .24 Table 16 Response: Get_Power_Supply_Data Datagram variable binding .24 Table 17 Command: Power_Supply_Control datagram.26 Table 18 Command: Get_Generator_Data datagram27 Table 19 Response: Get_Generator_Data datagram 27 Table 20 Response: Get_Generator_Data Data

27、gram variable binding27 Table 21 Command: Generator_Control datagram .28 Table 22 Response: Invalid_Request datagram .28 Table 23 Response: Request_Processed datagram .28 Page 4 EN 6072873:2005 Annex ZA (normative) Normative references to international publications with their corresponding European

28、publications . 29 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 07:42:24 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 6 067-82-73 IE:C0023()E INTRODUCTION Standards of the IEC 60728 series deal with cable networks for television signals, sound signals and interactive services including equipm

29、ent, systems and installations for head-end reception, processing and distribution of television and sound signals and their associated data signals, and processing, interfacing and transmitting all kinds of signals for interactive services using all applicable transmission media. All kinds of netwo

30、rks like CATV-networks, MATV-networks and SMATV-networks, individual receiving networks and all kinds of equipment, systems and installations installed in such networks, are within this scope. The extent of this standardization work is from the antennas, special signal source inputs to the head-end

31、or other interface points to the network up to the system outlet or the terminal input, where no system outlet exists. The standardization of any user terminals (i.e. tuners, receivers, decoders, multimedia terminals, etc.) as well as of any coaxial and optical cables and accessories therefore is ex

32、cluded. Page 5 EN 6072873:2005 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 07:42:24 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 067-82-73 IEC:20(30E) 7 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES Part 7-3: Hybrid Fibre Coax Outside Plant Status Monitoring

33、Power Supply to Transponder Interface Bus (PSTIB) specification 1 Scope This part of IEC 60728 specifies requirements for the Hybrid Fibre Coax (HFC) Outside Plant (OSP) Power Supplies (PS). This standard is part of a series developed to support the design and implementation of interoperable managem

34、ent systems for evolving HFC cable networks. The purpose of the standards is to support the design and implementation of interoperable management systems for evolving HFC cable networks. The Power Supply to Transponder Interface Bus (PSTIB) specification describes the physical (PHY) interface and re

35、lated messaging and protocols implemented at the Data Link Layer (DLL), layers 1 and 2 respectively in the 7-layer ISO-OSI reference model, that support communications between compliant transponders and the managed OSP power supplies and other related power equipment to which they interface. This st

36、andard describes the PSTIB PHY and DLL layer requirements and protocols that must be implemented to support reliable communications between all type 2 and type 3 compliant OSP transponders on the HFC plant and managed OSP power supplies and related hardware. Any exceptions to compliance with this st

37、aneard will be specifically noted as necessary. Refer to Table 1 for a full definition of the type classifications. Transponder type classifications referenced within the HMS series of standards are defined in Table 1. Table 1 Transponder type classifications Type Description Application Type 0 Refe

38、rs to legacy transponder equipment which is incapable of supporting the specifications This transponder interfaces with legacy network equipment through proprietary means. This transponder could be managed through the same management applications as the other types through proxies or other means at

39、the head-end Type 1 Refers to stand-alone transponder equipment (legacy or new), which can be upgraded to support the specifications This transponder interfaces with legacy network equipment through proprietary means. Type 1 is a standards-compliant transponder (either manufactured to the standard o

40、r upgraded) that connects to legacy network equipment via a proprietary interface Type 2 Refers to a stand-alone, compliant transponder This transponder interfaces with network equipment designed to support the electrical and physical specifications defined in the standards. It can be factory or fie

41、ld-installed. Its RF connection is independent of the monitored NE Type 3 Refers to a stand-alone or embedded, compliant transponder This transponder interfaces with network equipment designed to support the electrical specifications defined in the standards. It may or may not support the physical s

42、pecifications defined in the standards. It can be factory-installed. It may or may not be field- installed. Its RF connection is through the monitored NE Page 6 EN 6072873:2005 Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 13 07:42:24 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 8 067-82-73 IE:C

43、0023()E 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EIA RS-485, Electr

44、ical Characteristics of Generators and Receivers for Use in Balanced Digital Multipoint Systems 3 Terms, definitions and abbreviations 3.1 Terms and definitions For the purposes of this document, the following definitions apply. 3.2 data link layer (DLL) layer 2 in the Open System Interconnection (O

45、SI) architecture; the layer that provides services to transfer data over the physical transmission link between open systems 3.3 network element (NE) an active element in the outside plant (OSP) that is capable of receiving commands from a head-end element (HE) in the head-end and, as necessary, pro

46、viding status information and alarms back to the HE 3.4 open system interconnection (OSI) framework of International Organization for Standardization (ISO) standards for communication between multi-vendor systems that organizes the communication process into seven different categories that are place

47、d in a layered sequence based on the relationship to the user. Each layer uses the layer immediately below it and provides services to the layer above. Layers 7 through 4 deal with end-to-end communication between the message source and destination, and layers 3 through 1 deal with network functions

48、 3.5 physical (PHY) layer layer 1 in the Open System Interconnection (OSI) architecture; the layer that provides services to transmit bits or groups of bits over a transmission link between open systems and which entails electrical, mechanical and handshaking procedures 3.6 transponder device that i

49、nterfaces to outside plant (OSP) NEs and relays status and alarm information to the HE. It can interface with an active NE via an arrangement of parallel analogue, parallel digital and serial ports 3.7 Abbreviations DLL Data Link Layer EMS Element Management System Gnd Grund HE Head-end Element HFC