1、BRITISH STANDARD BS EN 62013-2:2001 IEC 62013-2:2000 Caplights for use in mines susceptible to firedamp Part 2: Performance and other safety-related matters The European Standard EN 62013-2:2000 has the status of a British Standard ICS 73.100.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED

2、BY COPYRIGHT LAW Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 14:15:44 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 62013-2:2001 This British Standard, having been prepared under the direction of the Electrotechnical Sector Committee, was published under the authority of the Standards

3、Committee and comes into effect on 15 April 2001 BSI 04-2001 ISBN 0 580 37139 5 National foreword This British Standard is the official English language version of EN 62013-2:2000. It is identical with IEC 62013-2:2000. It supersedes BS 4945:1989 which is withdrawn. The UK participation in its prepa

4、ration was entrusted by Technical Committee GEL/31, Electrical apparatus for use in explosive atmospheres, to Subcommittee GEL/31/14, Type of protection “e” and “n”, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary.

5、 From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-refer

6、ences Attention is drawn to the fact that CEN and CENELEC Standards normally include an annex which lists normative references to international publications with their corresponding European publications. The British Standards which implement these international or European publications may be found

7、 in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards

8、are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change,

9、 and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 13 and a back cover. The BSI copyright date displayed in this docum

10、ent indicates when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 14:15:44 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARDEN 62013-2 NORME EUROPENNE EUROPISCHE NORMDecember 2000 CENELEC Europ

11、ean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2000 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for

12、CENELEC members. Ref. No. EN 62013-2:2000 E ICS 29.260.20 English version Caplights for use in mines susceptible to firedamp Part 2: Performance and other safety-related matters (IEC 62013-2:2000) Lampes-chapeaux pour mines grisouteuses Partie 2: Performance et autres considrations concernant la scu

13、rit (CEI 62013-2:2000) Kopfleuchten fr schlagwettergefhrdete Grubenbaue Teil 2: Gebrauchstauglichkeit und Sicherheit (IEC 62013-2:2000) This European Standard was approved by CENELEC on 2000-08-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the cond

14、itions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in t

15、hree official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechn

16、ical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 14:15:44 GMT+00:00 2006, Uncontrol

17、led Copy, (c) BSI Foreword The text of document 31/325/FDIS, future edition 1 of IEC 62013-2, prepared by IEC TC 31, Electrical apparatus for explosive atmospheres, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 62013-2 on 2000-08-01. The following dates were fixed:

18、 latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement(dop) 2001-05-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 2003-08-01 Annexes designated “normative“ are part of

19、the body of the standard. In this standard, annexes A and ZA are normative. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 62013-2:2000 was approved by CENELEC as a European Standard without any modification. _ Page 2 EN 620132:2000 Licensed Copy:

20、 sheffieldun sheffieldun, na, Fri Nov 10 14:15:44 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BSI 04-2001 CONTENTS Page Clauses 1Scope 4 2Normative references. 4 3Definitions . 4 4General . 5 5Light output . 5 5.1Light sources 5 5.2Light source holder. 5 5.3Illumination cut-off angle. 5 5.4Illuminanc

21、e of main source . 6 5.5Auxiliary light source 6 5.6Focus . 6 6Reliability. 6 6.1Lamp life. 6 6.2Battery life (charge/discharge cycles) . 6 6.3Caplight useful working period 6 6.4Durability 6 7Ergonomics 7 7.1Mass. 7 7.2Ease of operation . 7 7.3Maintainability 7 8Type tests 7 8.1Illumination cut-off

22、 angle. 7 8.2Verification of the declared useful working period . 8 8.3Lamp life. 8 9Documentation. 9 10Marking . 9 Annex A (normative) Examples of the manufacturers instructions on user routine testing 10 A.1 Preparatory requirements 10 A.2 Evaluation procedure.10 A.3 Pass requirement 11 A.4 Specim

23、en test report .11 Annex ZA (normative) Normative references to international publications with their corresponding European publications 13 Figure A.1 Schematic drawing of a typical photometric sphere .11 Table 1 Illuminance of the main source . 6 Tabulation of tests.12 Page 3 EN 620132:2000 Licens

24、ed Copy: sheffieldun sheffieldun, na, Fri Nov 10 14:15:44 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BSI 04-2001 CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP Part 2: Performance and other safety-related matters 1 Scope This part of IEC 62013 details those performance and other safety features

25、not covered in IEC 62013-1, but which are nevertheless important for the safety and working conditions of the user. It may also be applied to caplights for use in mines not likely to be endangered by firedamp. When this part of the standard is used as a “stand-alone“ document for non-gassy mines, an

26、y relevent constructional requirements should be the subject of agreement between the supplier and the user and, where possible, be as described in IEC 62013-1. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of

27、 this part of IEC 62013. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However parties to agreements based on this part of IEC 62013 are encouraged to investigate the possibility of applying the most recent editions of the normative document

28、s indicated below. For undated references, the latest edition of the normative document referred to applies. Members of IEC and ISO maintain registers of currently valid International Standards. IEC 60050(845):1987, International Electrotechnical Vocabulary (IEV) Chapter 845: Lighting IEC 62013-1:19

29、99, Caplights for use in mines susceptible to firedamp Part 1: General requirements Construction and testing in relation to the risk of explosion IEC 60983, Miniature lamps ISO 1000, SI units and recommendations for the use of their multiples and of certain other units 3 Definitions For the purposes

30、 of this part of IEC 62013, the definitions of ISO 1000 and IEC 60050(845) and the following apply: 3.1 evaluation area circle with a diameter of 100 mm ? 2 mm on a plane parallel to the headpiece protective cover, positioned 1 000 mm ? 5 mm from it and having its centre fixed by the point of maximu

31、m illumination 3.2 useful working period period in hours during which the caplight may be continuously used with the current drain specified by the manufacturer and comply with the minimum illumination requirements of this part of IEC 62013 Page 4 EN 620132:2000 Licensed Copy: sheffieldun sheffieldu

32、n, na, Fri Nov 10 14:15:44 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BSI 04-2001 3.3 average illumination, Eave average value of illumination on the evaluation area 3.4 minimum illumination, Emin lowest measured value of illumination within the evaluation area 3.5 maximum illumination, Emax highest

33、 measured value of illumination within the evaluation area 3.6 cut-off angle solid angle formed by the illumination from the headpiece 4 General The caplight shall be designed in accordance with good engineering practice. It shall be fit for purpose and shall provide sufficient light for the user th

34、roughout the duration of the working period specified by the manufacturer. 5 Light output 5.1 Light sources 5.1.1 Every headpiece shall have a minimum of two light sources, at least one of which shall be the main source and meet the requirements of this part of IEC 62013. 5.1.2 Where a caplight is f

35、itted with two lamps or filaments, each of which is capable of being the main source, the manufacturer shall designate which of these shall be the main source and which the auxiliary source; otherwise, both sources shall meet the requirements for the main source. 5.1.3 Filament lamps for main and au

36、xiliary sources shall comply with IEC 60983. Where the relevant data sheet is not given in IEC 60983, an equivalent shall be provided by the caplight manufacturer. 5.2 Light source holder The holder for the main light source shall be capable of locating and retaining it securely in a focused positio

37、n with respect to the reflector profile in accordance with 5.6. 5.3 Illumination cut-off angle The luminous intensity from the main light source in a fully assembled headpiece shall not be less than 1 cd over a solid angle of 120 when tested in accordance with 8.1. Page 5 EN 620132:2000 Licensed Cop

38、y: sheffieldun sheffieldun, na, Fri Nov 10 14:15:44 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BSI 04-2001 5.4 Illuminance of main source The illuminance of the main source over the evaluation area shall not be less than the values given in table 1 when tested in accordance with 8.2. Table 1 Illumin

39、ance of the main source EmaxEaveEmin 1 500 lx750 lx150 lx 5.5 Auxiliary light source The auxiliary light source is primarily intended for emergency use if the main source fails and is exempt from the type tests in clause 8. It shall be rated at a minimum 1 W. 5.6 Focus The main light source shall be

40、 focused, or capable of being focused, so that the light pattern is not impaired by distortion. 6 Reliability 6.1 Lamp life The life of the main and auxiliary lamps shall comply with the values given in the data sheets in 5.1.3 when tested in accordance with 8.3. The minimum life shall be not less t

41、han 200 h for the main source and 50 h for the auxiliary source. 6.2 Battery life (charge/discharge cycles) It is not possible to specify a cyclic life for the battery due to the multiplicity of battery types, charging regimes and conditions of use. It is therefore important that the manufacturer pr

42、ovides instructions to the user on the recharge time and routine checks which are necessary to ensure that the battery is capable of performing its intended duties during the actual working period. See clause 9 and annex A. NOTE The choice of battery charging equipment will depend on the time availa

43、ble between successive actual working periods. When the recharge time is insufficient to fully recharge the battery, the manufacturer may need to advise the user to provide additional caplights. 6.3 Caplight useful working period The manufacturer shall declare the useful working period of the caplig

44、ht when new, taking into account the current drawn by the main light source and, if appropriate, the average current drawn by any accessories during that period. The test requirements are given in 8.2. 6.4 Durability 6.4.1 Fasteners and connectors Fasteners and connectors shall be designed so that t

45、hey do not loosen in normal use. Page 6 EN 620132:2000 Licensed Copy: sheffieldun sheffieldun, na, Fri Nov 10 14:15:44 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BSI 04-2001 6.4.2 Resistance to abrasion The caplight shall be constructed from materials which are resistant to abrasion in normal use. 6

46、.4.3 Operability after mechanical tests Following completion of the drop tests described in 10.3 of IEC 62013-1, at least one light source shall still be operable and there shall be no leakage of electrolyte. 7 Ergonomics 7.1 Mass Unless otherwise agreed between the manufacturer and the user, the ma

47、ss of the battery and container shall not exceed 2 750 g and the total mass of the complete caplight assembly shall not exceed 3 250 g. 7.2 Ease of operation The switch shall be easily accessible to the wearer with the caplight in the position normally worn. The switch shall be positive in action an

48、d shall have an “off“ position and such “on“ positions as are appropriate. NOTE The switch should be operable while wearing protective gloves. 7.3 Maintainability The caplight shall be constructed in such a manner that user replaceable parts are easily accessible after operation or removal of any sp

49、ecial fasteners. If necessitated by the battery design, means shall be provided for initial filling, subsequent topping up and changing of electrolyte. 8 Type tests 8.1 Illumination cut-off angle The following test shall be carried out in a darkened room where any reflected light will not influence the results, at a temperature of 20 C ? 5 C. Disconnect the headpiece and cable from the battery and connect it to a d.c. power source with a residual ripple not greater than 3 mV and capable of maintaining the voltage within