1、BRITISH STANDARD BS EN 60874-19:1997 IEC 60874-19: 1995 QC 912100: 1996 Connectors for optical fibres and cables Part 19: Sectional specification for fibre optic connector Type SC-D (Duplex) The European Standard EN 60874-19:1997 has the status of a British Standard ICS 33.180.20 Licensed Copy: shef

2、fieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BS EN 60874-19:1997 This British Standard, having been prepared under the direction of the Electrotechnical Sector Board, was published under the authority of the Standards Board and comes into effect on 15 Augus

3、t 1997 BSI 09-1999 ISBN 0 580 27785 2 National foreword This British Standard is the English language version of EN 60874-19:1997. It is identical with IEC 60874-19:1995. This standard is a harmonized specification within the IEC quality assessment system for electronic components (IECQ). In the IEC

4、Q system, this specification is numbered QC 912100. The UK participation in its preparation was entrusted by Technical Committee EPL/86, Fibre optics, to Subcommittee EPL/86/2, Interconnecting devices and passive components, which has the responsibility to: aid enquirers to understand the text; pres

5、ent to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee ca

6、n be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain

7、identifiers from both systems. Cross-references Attention is drawn to the fact that Annex ZA lists normative references to international publications with their corresponding European publications. The British Standards which implement these international or European publications may be found in the

8、 BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are respon

9、sible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 8, an inside back cover and a back cover. Th

10、is standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No.DateComments Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006

11、, Uncontrolled Copy, (c) BSI BS EN 60874-19:1997 BSI 09-1999i Contents Page National forewordInside front cover Foreword2 Text of EN 60874-193 Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI ii blank Licensed Copy: sheffieldun sheffieldun, n

12、a, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60874-19 May 1997 ICS 33.180.20 Descriptors: Sectional specification for fibre optic connector, type SC-D(uplex) English version Connectors for optical fibres and cables Part 19: Se

13、ctional specification for fibre optic connector Type SC-D(uplex) (IEC 874-19:1995 + corrigendum 1996) Connecteurs pour fibres et cbles optiques Partie 19: Spcification intermdiaire pour connecteur pour fibres optiques Type SC-D(uplex) (CEI 874-19:1995 + corrigendum 1996) Steckverbinder fr Lichtwelle

14、nleiter und LWL-Kabel Teil 19: Rahmenspezifikation fr LWL-Steckverbinder Typ SC-D(uplex) (IEC 874-19:1995 + Corrigendum 1996) This European Standard was approved by CENELEC on 1997-03-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for

15、 giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three offic

16、ial versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical commi

17、ttees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Eur

18、opisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1997 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60874-19:1997 E Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55

19、:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60874-19:1997 BSI 09-1999 2 Foreword The text of the International Standard IEC 874-19:1995 and its corrigendum May 1996, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the

20、 formal vote and was approved by CENELEC as EN 60874-19 on 1997-03-11 without any modification. The following dates were fixed: Annexes designated “normative” are part of the body of the standard. In this standard, Annex ZA is normative. Annex ZA has been added by CENELEC. Endorsement notice The tex

21、t of the International Standard IEC 874-19:1995 and its corrigendum May 1996 was approved by CENELEC as a European Standard without any modification. Contents Page Foreword2 1General3 1.1Scope3 1.2Normative references3 1.3Definitions3 2Requirements3 2.1Classification3 2.2Reference components3 2.3Gau

22、ges3 2.4Non-flammable materials3 3Quality assessment procedures7 3.1Qualification approval7 3.2Quality conformance inspection7 Annex ZA (normative) Normative references to international publications with their corresponding European publicationsInside back cover Figure 1 Plug mating face dimensions4

23、 Figure 2 Adaptor mating face dimensions6 latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement(dop) 1997-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 1997-12-01 Li

24、censed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60874-19:1997 BSI 09-19993 1 General 1.1 Scope This sectional specification is part of the relevant specification for Type SC-D(uplex) connectors. The specification, along with the appropriate

25、 blank detail specification, defines the requirements and the quality assessment procedures for the subfamily. Type SC-D(uplex) is a subfamily of two-way optical fibre connectors utilizing a push-pull coupling mechanism and cylindrical ferrules of 2,5 mm nominal diameter. 1.2 Normative references Th

26、e following normative documents contain provisions which, through reference in this text, constitute provisions of this part of IEC 874. At the time of publication, the editions indicated were valid. All normative documents are subject to revision and parties to agreements based on this part of IEC

27、874 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. NOTEReferences to specific clauses or subclauses include all subclauses to the refe

28、rence unless otherwise specified. IEC 874-1:1993, Connectors for optical fibres and cables Generic specification. IEC 874-14:1993, Connectors for optical fibres and cables Part 14: Sectional specification for fibre optic connectors Type SC. 1.3 Definitions None. 2 Requirements The requirements speci

29、fied herein and in section 2 of IEC 874-1 apply. 2.1 Classification The connectors covered by this specification are classified as: Type: name: SC-D; coupling: push-pull; configurations: plug-adapter-plug; plug-socket. The single limit (maximum or minimum) mating face dimensions for each connector s

30、et configuration are given in Figure 1 and Figure 2. The detail specification defines the mating face dimensions, arrangement, style, variants, climatic category, environmental category, and assessment level(s). 2.2 Reference components The detail specification shall define reference components when

31、 they are required. 2.3 Gauges The detail specification shall define gauges when they are required. 2.4 Non-flammable materials The detail specification shall define non-flammable materials when they are required. Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncont

32、rolled Copy, (c) BSI EN 60874-19:1997 4 BSI 09-1999 Figure 1 Plug mating face dimensions Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60874-19:1997 BSI 09-19995 Reference DimensionsNotes Min.Nom.Max. Y12,2513,153 PC12,51 DimensionsMMFa

33、SMFaNotes PA2,7 max.1,8 max.4 PBR 1,35 max.R 0,9 max.4 NOTE 1The projection of drawings is in third angle. NOTE 2Original dimensions are in millimetres. NOTE 3Individual plugs may be aligned in a sleeve or by a clamp that allows for deviations from this dimension. NOTE 4This dimension applies typica

34、lly to both keys and shall be specified in the relevant detail specification. a MMF: Multimode fibre SMF: Single-mode fibre Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60874-19:1997 6 BSI 09-1999 Figure 2 Adaptor mating face dimension

35、s Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60874-19:1997 BSI 09-19997 3 Quality assessment procedures The quality assessment procedures specified herein and in section 3 of IEC 874-1 apply. 3.1 Qualification approval 3.1.1 Fixed sa

36、mple procedure When specified, the fixed sample procedure shall be in accordance with 3.3.1 of IEC 874-1. The relevant blank detail specification contains the minimum mandatory test schedules and performance requirements for qualification by the fixed sample procedure. The complete set of mandatory

37、test schedules and performance requirements shall be specified in the detail specification. Upon successful completion of the tests, qualification approval will be granted for the complete range of variants submitted as structurally similar. 3.1.1.1 Sample size The sample size for qualification by t

38、he fixed sample procedure shall be specified in the detail specification. The specimens shall be complete connector sets of a variant for the fibre core diameter specified in the detail specification. In addition, the following samples shall be provided: one specimen of each plug variant to be quali

39、fied by structural similarity to the one used for group “0”; one specimen of each adaptor variant to be qualified by structural similarity to the one used for group “0”; one specimen of each socket variant to be qualified by structural similarity to the one used for group “0”. Following completion o

40、f the group “0” tests, the specimens for the other groups shall be randomly selected from the group “0” sample. 3.1.1.2 Preparation of specimens Test specimens for kit arrangements shall be terminated using the smallest core diameter specified in the detail specification. The fibre/cable type and le

41、ngths to be used for all arrangements shall be as specified in the detail specification. 3.1.1.3 Testing The tests shall be conducted in the order given, in accordance with the method specified and the specimens shall satisfy the performance requirements of the detail specification. The additional v

42、ariant specimens (see 3.1.1.1) shall be tested to all group “0” tests and shall meet the requirements of the detail specification. 3.1.2 Lot-by-lot and periodic procedure When specified, the lot-by-lot plus periodic qualification procedure shall be in accordance with 3.3.1 of IEC 874-1 (see 3.2.1 an

43、d 3.2.2 for test schedules). Upon successful completion of the tests, qualification approval will be granted for the complete range of variants submitted as structurally similar. 3.2 Quality conformance inspection 3.2.1 Lot-by-lot inspection The minimum mandatory inspection schedules for lot-by-lot

44、inspection are specified in the relevant blank detail specification. The complete set of mandatory test schedules and performance requirements shall be specified in the detail specification. Reference DimensionsNotes Min.Nom.Max. Y12,6512,75 AO35 AP30,0 AQ25,9 AR2,3 AS9,43 AT21,7 AU3,7 AD7,47,5 AE9,

45、09,1 AF3,725Basic AG4,525 Basic DimensionsMMFaSMFaNotes AA2,9 min.2,0 min.4 ABR 1,45 min.R 0,95 min.4 NOTE 1The projection of drawings is in third angle. NOTE 2Original dimensions are in millimetres. NOTE 3This dimension is the true position of the centres of the alignment sleeves. NOTE 4This dimens

46、ion applies typically to both keyways and shall be specified in the relevant detail specification. a MMF: Multimode fibre SMF: Single-mode fibre Licensed Copy: sheffieldun sheffieldun, na, Sat Nov 11 09:55:08 GMT+00:00 2006, Uncontrolled Copy, (c) BSI EN 60874-19:1997 8 BSI 09-1999 3.2.2 Periodic in

47、spection The minimum mandatory periodic test schedules are specified in the relevant specification. The complete set of mandatory test schedules and performance requirements shall be specified in the detail specification. Upon successful completion of the tests, periodic inspection approval will be

48、granted for the complete range of variants submitted as structurally similar. 3.2.2.1 Sample size The sample size for periodic inspection shall be as specified in the detail specification. The specimens shall be complete connector sets of a variant for the smallest fibre core diameter specified in t

49、he detail specification. In addition, the following samples shall be provided: one specimen of each plug variant to be qualified by structural similarity to the one used for group “C0” or D0”; one specimen of each adaptor variant to be qualified by structural similarity to the one used for group “C0” or “D0”; one specimen of each socket variant to be qualified by structural similarity to the one used for group “C0” or “D0”. Following completion of the group “C0” or “D0” tests, the specim