1、BRITISH STANDARD BS EN 61169-24:2002 IEC 61169-24:2001 Radio-frequency connectors Part 24: Sectional specification Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable distribution systems (type F) The European Standard EN 61169-24:2001 has the status of a Britis

2、h Standard ICS 29.120.20; 33.120.30 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Licensed Copy: London South Bank University, London South Bank University, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 61169-24:2002 This British Standard, having been

3、prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 13 February 2002 BSI 13 February 2002 ISBN 0 580 38972 3 National foreword This British Standard is the official English lang

4、uage version of EN 61169-24:2001. I t is identical with IEC 61169-24:2001. The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires, waveguides, RF connectors and accessories for communication and signalling, to Subcommittee EPL/46/2, RF connectors and waveg

5、uides, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a peri

6、od of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue und

7、er the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct a

8、pplication. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed

9、; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 18, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates

10、 when the document was last issued. Amendments issued since publication Amd. No. DateComments Licensed Copy: London South Bank University, London South Bank University, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EUROPEAN STANDARDEN 61169-24 NORME EUROPENNE EUROPISCHE NORMDecember

11、 2001 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2001 CENELEC -All rights of exploitation in any form and by any means rese

12、rved worldwide for CENELEC members. Ref. No. EN 61169-24:2001 E ICS 31.220.10 English version Radio-frequency connectors Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable distribution systems (type F) (IEC 61169-24:2001) Conn

13、ecteurs pour frquences radiolectriques Partie 24: Spcification intermdiaire - Connecteurs coaxiaux pour frquences radiolectriques avec couplage viss, spcifiquement utiliss dans les systmes de distribution des cbles 75 ohm (srie F) (CEI 61169-24:2001) Hochfrequenz-Steckverbinder Teil 24 Rahmenspezifi

14、kation - Koaxiale Hochfrequenzsteckverbinder mit Schraubkupplung, vorzugsweise fr den Einsatz in 75 Ohm Kabelverteilnetzen (Typ F) (IEC 61169-24:2001) This European Standard was approved by CENELEC on 2001-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which sti

15、pulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Stand

16、ard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the nation

17、al electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: London South Bank University, London South Bank Univ

18、ersity, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61169-24:2001- 2 - Foreword The text of document 46D/338/FDIS, future edition 1 of IEC 61169-24:2001, prepared by SC 46D, RF connectors, of IEC TC 46, Cables, wires, waveguides, RF connectors, and accessories for communication

19、 and signalling, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-24 on 2001-12-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement(dop) 2002-0

20、9-01 latest date by which the national standards conflicting with the EN have to be withdrawn(dow) 2004-12-01 Annexes designated “normative“ are part of the body of the standard. In this standard, annex ZA is normative Annex ZA has been added by CENELEC. _ Endorsement notice The text of the Internat

21、ional Standard IEC 61169-24:2001 was approved by CENELEC as a European Standard without any modification. _ Page 2 EN 6116924:2001 BSI 13 February 2002 Licensed Copy: London South Bank University, London South Bank University, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI -961161002

22、:CEI 42 3 CONTENTS 1Scope 4 2Normative reference 4 3Interface dimensions 4 3.1Dimensions . 4 3.2Mechanical gauges 7 4Quality assessment procedures 7 4.1General . 7 4.2Ratings and characteristics 7 4.3Test shedule and ispection requirements . 9 4.4Procedures 10 5Instructions for preparation of detail

23、 specifications . 11 5.1General . 11 5.2Identification of the detail specification. 11 5.3Identification of the component 11 5.4Performance 12 5.5Marking, ordering information and related matters 12 5.6Selection of tests, test conditions and severities. 12 5.7Blank detail specification pro-forma for

24、 type F connector 13 Annex ZA (normative) Normative references to international publications with their corresponding European publications . 18 Page 3 EN 6116924:2001 BSI 13 February 2002 Licensed Copy: London South Bank University, London South Bank University, Wed Jan 10 01:43:05 GMT+00:00 2007,

25、Uncontrolled Copy, (c) BSI -961161002:CEI 42 4 RADIO-FREQUENCY CONNECTORS Part 24: Sectional specification Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable distribution systems (type F) 1 Scope This part of IEC 61169, which is a sectional specification (SS),

26、provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with screw coupling, typically for use in 75 ? cable distribution systems (type F). It describes the interface dimensions for general purpose grade 2 connectors, dimensional details for standar

27、d test connectors, grade 0, together with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all DS relating to type F connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules a

28、nd inspection requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies

29、. IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods 3 Interface dimensions 3.1 Dimensions Millimetres are original dimensions. All undimensioned pictorial configurations are for reference purposes only. Page 4 EN 6116924:2001 BSI 13

30、 February 2002 Licensed Copy: London South Bank University, London South Bank University, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI -961161002:CEI 42 5 3.1.1 Connector with pin centre contact For notes 1, 2 and 3, see next page. mmin Reference Min.Max.Min.Max. a4,956,860,1950,27

31、0 b7,290,287 c0,250,010 d0,511,630,0200,064 e12,950,510 f3,80,149 Figure 1 Connector with pin centre contact IEC 2204/01 Page 5 EN 6116924:2001 BSI 13 February 2002 Licensed Copy: London South Bank University, London South Bank University, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) B

32、SI -961161002:CEI 42 6 3.1.2 Connector with socket centre contact mmin Reference Min.Max.Min.Max. g h3,860,152 i0,300,012 j5,560,219 k7,00,273 l7,590,299 m4,700,185 Figure 2 Connector with socket centre contact Notes relative to figures 1 and 2 NOTE 1 Protrusion of the dielectric beyond the referenc

33、e plane is applicable only to the 0,146 in nominal dielectric core diameter cables. When larger core diameter cables are used, no protrusion of the dielectric beyond the reference plane is permitted. NOTE 2 Shape of coupling nut is optional; however, provision for wrench tightening should be made. F

34、or example, wrench flats. NOTE 3 Applicable only to the 0,146 in nominal dielectric core diameter cables. The 3,8 mm maximum diameter is not applicable when larger core diameter cables are used. NOTE 4 Length of full thread. NOTE 5 Shape of connector body is optional; however, provision for wrench t

35、ightening should be made. For example, wrench flats. NOTE 6 Socket contact accepts a pin contact of 0,51 mm to 1,63 mm (0,020 in to 0,064 in); this will be satisfied at dimension m. IEC 2205/01 Page 6 EN 6116924:2001 BSI 13 February 2002 Licensed Copy: London South Bank University, London South Bank

36、 University, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI -961161002:CEI 42 7 3.2 Mechanical gauges Millimetres are original dimensions. All undimensioned pictorial configurations are for reference purposes only. ?a R0,5 8 0 0,1 +0,2 0 IEC 2206/01 Gauge CGauge D Reference mmmm Min.

37、Max.Min.Max. ?a2,1002,1200,5700,580 Figure 3 Gauge pins for centre contact of socket connector Test sequence a) Steel test pin (C) (figure 3) shall be inserted once into the centre contact. b)A second steel test pin (D) (figure 3) shall be inserted into the centre contact. This gauge when in a verti

38、cal downward attitude shall be retained by the contact. This gauge will have a mass (weight) of 0,30 N. 4 Quality assessment procedures 4.1 General The following subclauses provide recommended ratings, performance and test conditions to be considered when writing a detail specification (DS). They al

39、so provide an appropriate schedule of tests with minimum levels of conformance inspection. 4.2 Ratings and characteristics The RF connectors defined in this standard are designed for use with a variety of flexible and semi-rigid coaxial cables and in microwave integrated circuits and similar uncable

40、d applications. Page 7 EN 6116924:2001 BSI 13 February 2002 Licensed Copy: London South Bank University, London South Bank University, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI -961161002:CEI 42 8 Ratings and characteristics IEC 61169-1 Subclause Value Remarks including any devi

41、ations from standard test methods Electrical Nominal impedanceShall meet the requirements of 9.2.1.1 of IEC 61169-1 when terminating a Zc = 75 ? cable Frequency range0-2 GHzSee DS Reflection factor49.2.14. - straight styles ?7 7 % % - right angle stylesSee DS - solder bucket and PCB mounting styleUn

42、der consideration Centre contact resistance9.2.3 - initial 1 M? Proof voltage at sea level + ?.9.2.6750 V86-106 kPa Screening effectiveness.9.2.8as ? 90 dBZt Discharge test (Corona).9.2.9na Mechanical Gauge retention force (resilient contacts)9.3.4See 3.2 of IEC 61169-1 Contact captivation axial for

43、ce torque 9.3.5 30 N na Captivated contacts only Engagement and separation Coupling torque friction coupling proof 9.3.6 0,066 Nm max. 0,46-0,69 Nm 1,7 Nm Screw coupling connectors To overcome friction of a coupling nut Mechanical tests on cable cable pulling cable torsion 9.3.8 9.3.10 120 N 0,1 Nm

44、Tensile strength of coupling mechanism9.3.11300 N Bending moment9.3.122 NmRelative to reference plane Environmental Vibration9.3.398 m/s 10-500 Hz 10 g acceleration Climatic sequence9.4.240/70/21 Sealing9.4.51 cm3/h max.100-110 kPa pressure Salt mist9.4.648 h Endurance Mechanical0,19.57.101 000 cycl

45、es High temperature9.601 000 h NOTES ? These values apply to basic connectors. They depend on the cable used. Relevant values are given in the DS. + Voltage values are r.m.s. values at 50-60 Hz, unless otherwise specified. # Cables used with these connectors may have values of lower performance than

46、 those given in this table. Page 8 EN 6116924:2001 BSI 13 February 2002 Licensed Copy: London South Bank University, London South Bank University, Wed Jan 10 01:43:05 GMT+00:00 2007, Uncontrolled Copy, (c) BSI -961161002:CEI 42 9 4.3 Test schedule and inspection requirements 4.3.1 Acceptance tests N

47、OTE For details of symbols, abbreviations and procedures, see 4.4.2. Assessment level M (higher)Assessment level H (lower)Test method IEC 61169-1 Subclause Test required ILAQL %Period Test required ILAQL %Period Group A1 Visual examination9.1.2aII1,0aS31,5 Group B1 Outline dimensions9.1.3.1aS40,4aS3

48、4,0 Mechanical compatibility9.1.3.3aII1,0aS31,5 Engagement and separation9.3.6aS40,40LotaS31,5Lot Gauge retention (resilient contact) 9.3.4iaII1,0iaS31,5 Sealing, non-hermetic9.4.5.1iaII0,65byiaS31,0by Sealing, hermetic9.4.5.2iaII0,015iaS30,025 Voltage proof9.2.6aS40,40lotaII4,0lot Solderability pie

49、ce parts9.3.2.1.1iaS40,40iaS34,0 Insulation resistance9.2.5aS40,40aS34,0 4.3.2 Periodic tests There are no group C tests for levels H and M. NOTE For details of symbols, abbreviations and procedures, see 4.4.2. Assessment level M (higher)Assessment level H (lower) Test method IEC 61169-1 SubclauseTest required Number of specimens Permitted failures per group PeriodTest required Number of specimens Permitted failures per group Period