1、BRITISH STANDARD BS EN 61169-16:2007 Radio-frequency connectors Part 16: Sectional specification RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling Characteristic impedance 50 ohms (75 ohms) (type N) The European Standard EN 61169-16:2007 has the status

2、of a British Standard ICS 33.120.30 ? Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI BS EN 61169-16:2007 This British Standard was published under the authority of the Standards Policy and Strategy Committee o

3、n 31 May 2007 BSI 2007 ISBN 978 0 580 50828 8 National foreword This British Standard was published by BSI. It is the UK implementation of EN 61169-16:2007. It is identical with IEC 61169-16:2007. It supersedes BS QC222100:1997 which is withdrawn. The UK participation in its preparation was entruste

4、d by Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling, to Subcommittee EPL/46/2, Radio frequency connectors and waveguides. A list of organizations represented on this committee can be obtained on request to its sec

5、retary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. DateComments Licensed Cop

6、y: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EUROPEAN STANDARD EN 61169-16 NORME EUROPENNE EUROPISCHE NORM April 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electr

7、otechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61169-16:2007 E ICS 33.120.30 English version Radio-freque

8、ncy connectors - Part 16: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling - Characteristic impedance 50 ohms (75 ohms) (type N) (IEC 61169-16:2006) Connecteurs pour frquences radiolectriques - Partie 16: Spcification intermdi

9、aire - Connecteurs coaxiaux pour frquences radiolectriques avec diamtre intrieur du conducteur extrieur de 7 mm (0,276 in) verrouillage vis - Impdance caractristique de 50 ohms (75 ohms) (Type N) (CEI 61169-16:2006) Hochfrequenz-Steckverbinder - Teil 16: Rahmenspezifikation - Koaxiale Hochfrequenzst

10、eckverbinder mit 7 mm (0,276 in) Innendurchmesser des Auenleiters und Schraubverbindung - Wellenwiderstand 50 Ohm (75 Ohm) (Typ N) (IEC 61169-16:2006) This European Standard was approved by CENELEC on 2007-03-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which sti

11、pulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Stand

12、ard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the nation

13、al electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,

14、 Switzerland and the United Kingdom. Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61169-16:2007 2 Foreword The text of document 46F/54/FDIS, future edition 1 of IEC 61169-16, prepared by SC 46F, R.F. and

15、microwave passive components, of IEC TC 46, Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61169-16 on 2007-03-01. The following dates were fixed: latest date by which

16、 the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-03-01 Annex ZA has been added by CENELEC. _ Endorsement notice The t

17、ext of the International Standard IEC 61169-16:2006 was approved by CENELEC as a European Standard without any modification. _ Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 3 EN 61169-16:2007 CONTENTS 1 Scope

18、 5 2 Normative references .5 3 IEC type designation 6 4 Interface dimensions 6 4.1 Dimensions General purpose connectors Grade 2 6 5 Mechanical gauges and standard test connectors11 5.1 Mechanical gauges11 5.2 Standard test connectors Grade 0.12 6 Overall dimensions.16 7 Quality assessment procedure

19、s 16 7.1 General.16 7.2 Ratings and characteristics16 7.3 Test schedule and inspection requirements19 7.4 Procedures21 8 Instructions for preparation of detail specifications 21 8.1 General.21 8.2 Identification of the Detail specification 21 8.3 Identification of the component 22 8.4 Performance22

20、8.5 Marking, ordering information and related matters 22 8.6 Selection of tests, test conditions and severities.22 8.7 Blank detail specification pro-forma for type N connector23 Annex A (informative) Guidance information for interface dimensions of 75 characteristic impedance general purpose connec

21、tors .28 Annex ZA (normative) Normative references to international publications with their corresponding European publications31 Bibliography .30 Figure 1 Connector with pin centre contact 7 Figure 2 Details of pin centre contact 7 Figure 3 Connector with socket centre contact .9 Figure 4 Details o

22、f socket centre contact .9 Figure 5 Gauge rings for outer contact of pin connector 11 Figure 6 Gauge and test pins for socket centre contact 12 Figure 7 Standard test connector with pin centre contact .13 Figure 8 Details of pin centre contact 13 Figure 9 Standard test connector with socket centre c

23、ontact 15 Figure 10 Details of socket centre contact .15 Figure A.1 Details of pin centre contact 28 Table 1 Dimensions for connector with pin centre contact .8 Table 2 Dimensions for connector with socket centre contact10 Licensed Copy: London South Bank University, London South Bank University, Fr

24、i Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61169-16:2007 4 Table 3 Dimensions for test pins for socket centre contact12 Table 4 Dimensions for standard test connector with pin centre contact 14 Table 5 Dimensions for standard test connector with socket centre contact.16 Table 6

25、Ratings and characteristics17 Table 7 Acceptance tests.19 Table 8 Periodic tests 20 Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 5 EN 61169-16:2007 RADIO-FREQUENCY CONNECTORS Part 16: Sectional specification

26、 RF coaxial connectors with inner diameter of outer conductor 7 mm (0,276 in) with screw coupling Characteristics impedance 50 (75 ) (type N) 1 Scope This part of IEC 61169, which is a Sectional Specification (SS), provides information and rules for the preparation of Detail Specifications (DS) for

27、pin and socket R.F. coaxial connectors, with screw coupling mechanism, for low to medium power applications. The connector is commonly known as the “type N“. Three versions of the 50 characteristic impedance type N connector are included, each version being mateable with each of the others. The gene

28、ral purpose connector (grade 2) derived from the specifications MIL-C17B and MIL- C-39012 may preferably be used with R.F. cable 60096 IEC 50-7 up to about 12 GHz maximum frequency. The high performance connector (grade 1) is particularly suitable for microwave applications when lower reflection fac

29、tors than are offered by the general purpose connector are required. The connectors may also be suitable for microwave components. The tolerances of the interface dimensions lie between those for grade 0 and grade 2, and are chosen to give the performance required. Some grade 1 connectors conforming

30、 to this specification may be used up to 18 GHz maximum frequency. The standard test connector (grade 0) has a closely controlled interface to provide a reference for the measurement of connectors, cable assemblies, components and equipment with the above two interfaces. It may also be used as a mic

31、rowave connector in situations when the most precise interface for use up to 18 GHz maximum frequency is required. A 75 characteristic impedance connector is given in Annex A even though the use of 75 type N connectors is strongly deprecated. Accidental cross-coupling of 75 with 50 connectors can de

32、structively damage the 75 version, but in view of the extensive use of a number of marginally different 75 versions, the interface now given provides common design guidance. 75 connectors should be clearly identified. This specification indicates the recommended performance characteristics to be con

33、sidered when writing a DS and covers test schedules and inspection requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the r

34、eferenced document (including any amendments) applies. IEC 60068-1:1988, Environmental testing Part 1: General and guidance Amendment 1 (1992) Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61169-16:2007 6

35、IEC 60096-2:1988, Radio-frequency cables Part 2: Relevant cable specifications IEC 61169-1:1992, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods Amendment 1 (1996) Amendment 2 (1997) ISO 263:1973, ISO inch screw threads General plan and selection f

36、or screws, bolts and nuts Diameter range 0.06 to 6 in 3 IEC type designation Connectors conforming to this specification shall be designated by: a) the reference to this specification: 61169-16 IEC; b) characteristic impedance 50 (75 ); c) number of the grade : grade 0 = standard test connector = G

37、0; grade 1 = high performance connector = G 1; grade 2 = general purpose connector if grade 2 is required, no grade designation is necessary; d) a group of figures specifying the climatic category (see 7.2.5). Example: 61169-16 IEC-50-G 0 denotes a standard test connector, type N, 50 . 4 Interface d

38、imensions 4.1 Dimensions General purpose connectors Grade 2 4.1.1 General Inch dimensions are original dimensions. NOTE The values for dimensions in millimetres derived from those in inches are not necessarily exact (according to ISO 3701), but they should be considered as acceptable alternatives to

39、 the original values. All undimensioned pictorial configurations are for reference purposes only. _ 1 This document has been withdrawn. Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 7 EN 61169-16:2007 4.1.2 C

40、onnector with pin centre contact ab c h r (Note 9) k m n f Note 5 Note 3 Note 1 Note 6 H O M HM IEC 2246/06 Figure 1 Connector with pin centre contact (for notes and dimensions, see Table 1) p Note 1 e s g q d Note 7 ab IEC 2247/06 Figure 2 Details of pin centre contact (for notes and dimensions, se

41、e Table 1) Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61169-16:2007 8 Table 1 Dimensions for connector with pin centre contact mm inches Reference Min. Max. Min. Max. Note a 7,00 nom. 0,275 6 nom. 2, di

42、am. b 8,027 0,316 3/10, diam. c 5/8-24 UNEF-2B 4 d 3,04 nom. 0,120 nom. 2, diam. e f g h k m n p q r s ab 5.33 9,25 0,0 16,0 0,41 4,013 4,5 1,600 0,15 2,79 1,57 1,52 4,267 1,676 0,1 3,56 0,64 0.210 0,364 0,0 0,630 0,016 0,158 0,177 0,063 0,006 0,110 0,062 0,060 0,168 0,066 0,004 0,140 0,025 6 10, di

43、am. 8 10, diam. radius 9 7, radius NOTE 1 Mechanical and electrical reference plane. NOTE 2 Diameter of outer and centre contact to provide nominal (50 ) characteristic impedance to meet electrical performance requirements. NOTE 3 Slots or other forms of resilience optional. If slotted, indicated di

44、mension b should not exceed 8,38 mm (0,330 in). Gauging requirements (see 5.1.1) to be met. NOTE 4 Thread 5/8-24 UNEF-2B (according to ISO 263). NOTE 5 Compensation for inductance of inner conductor gap in mated pair of connectors optional. NOTE 6 Dimensions given assume no sealing gasket fitted. If

45、 sealing is required, dimension (Figure 1) should be arranged so that with the gasket chosen adequate pressure is applied to the front face (dimensions w and x) of the socket connector (Figure 2) to ensure adequate sealing. NOTE 7 Radius or chamfer, shape of tip optional. 0,25 mm (0,010 in) maximum

46、flat permitted. NOTE 8 Applies with nut biased forward. NOTE 9 External form of leading edge of outer contact optional, but connector should meet electrical and mechanical performance requirements. NOTE 10 Diameters b, h and p and thread c should be gauged to ensure that on MMC, each feature is on o

47、r can take up a common axis. Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 9 EN 61169-16:2007 4.1.3 Connector with socket centre contact a Note 1 H byxwc y h f e m ad n z k r (Note 5) Note 4 OMHM IEC 2248/06

48、Figure 3 Connector with socket centre contact (for notes and dimensions, see Table 2) d Note 6 s p IEC 2249/06 Figure 4 Details of socket centre contact (for notes and dimensions, see Table 2) Licensed Copy: London South Bank University, London South Bank University, Fri Jun 01 01:42:39 GMT+00:00 2007, Uncontrolled Copy, (c) BSI EN 61169-16:2007 10 Table 2 Dimensions for connector with socket centre contact mm inches Reference Min. Max. Min. Max. Note a 7,06 0,278 2, diam. b 8,027 8,13 0,316 0,320 diam. c 5/8-24 UNEF-2A 3 d 3,04 nom. 0,