1、EIA 520D000 87 3234600 0073536 T = O O O O Cu u I w c i 0 EIA SPEC I F I CAT ION ANSVEIA- 520OOO- 1987 APPROVED: APRIL 10, 1987 - . . Sectional Specif ication for Toggle, Paddle and Rocker Switches of Certified Quality EIA-520D000 SEPTEMBER 1987 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTME

2、NT Copyright Electronic Components, Assemblies b) select t h e appropriate tests which may be applicable t o t h i s family of switches; and c) prescribe general performance requirements for these switches. T e s t s e v e r i t i e s and performance requirements prescribed i n Detail Specifications

3、 referring t o t h i s Sectional Specification s h a l l be equal t o o r greater than those specified herein; degradations a r e not permitted. Copyright Electronic Components, Assemblies but, i n no case, shall t h e r e be less than four test specimens t o t a l 121 = The appropriate electrical e

4、ndurance test(s) s h a l l be selected based upon the specified electrical r a t i n g s 31 = The appropriate electrical endurance test(s) shall be selected based upon the specified electrical and O tempera t u r e r a t i n g s Copyright Electronic Components, Assemblies & Materials Association Pro

5、vided by IHS under license with ECA Licensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 01:41:03 MDTNo reproduction or networking permitted without license from IHS -,-,- EIA 520D000 87 3234b00 0073547 4 EIA-520D0BD Page 8 3.2 Q u a l i t y Conformance Inspection Quality

6、conformance inspection shall be as prescribed by EIA-5200000 and t h e following requirements: a) Lot-By-Lot Inspection T e s t : The lot-by-lot inspection tests a r e prescribed i n Table II herein. The sequence of tests is optional, unless otherwise specified by the Detail Specification. b) Period

7、ic Inspection T e s t s : The periodic inspection t e s t s a r e prescribed i n Table I I I herein. Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 01:41:03 MDT

8、No reproduction or networking permitted without license from IHS -,-,- E I A 520D000 87 = 3234600 0073548 b EIA-520D000 Page 9 TABLE II Lo t-By-Lo t In spec t ion T e s t s T e s t Methods and T e s t T e s t Groups ( T e s t Frequency) .No . Acceptance T e s t s Group A (lot-by-lot) V i s u a l Exa

9、mination 1-1 Major Minor Functional Operation 1-5 Switch Resistance 2-1 Vol tage Proof 3-1 Operating Characteristics 1-6 Assessments L e v e l s D or Lev e 1 I1 CI1 i 1 ND I L AQL ND ND ND ND ND I II s3 s 3 53 1.5 4.0 4.0 1.5 1.0 2.5 Assessment level C per paragraph 3.4 i n EIA-5200000, with the l i

10、 s t e d Inspection Levels ( I L ) and Acceptable Quality Level (AQL) , is t h e minimum acceptable level. Additional, higher l e v e l s can be developed, as required for s p e c i f i c Detail Speci f i c a t ions . Copyright Electronic Components, Assemblies & Materials Association Provided by IH

11、S under license with ECA Licensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 01:41:03 MDTNo reproduction or networking permitted without license from IHS -,-,- E I A 520D000 87 = 3234b00 O073549 EIA-520B000 Page 10 TABLE III Per iodic T e s t Methods and T e s t Groups (

12、T e s t Frequency) Group X (every 12 months) Visual Examina t i o n Dimen s i 01-1s Opera ti ng Character i stics Switch Resistance Insulation Resistance Solder ab il i t y Strength of Terminations Strength of Actuator Overloa Electrical Endurance Temperature R i s e Voltage P K Q O f Group B (every

13、 36 months) Over 1 oad Electrical Endurance Temperature R i s e V o l tage Proof Sealing Group C (ev,ery 36 months) Thermal Shock A c c e l er a t is n Vibration Shock Hum id i t y Operating Charas ter istics Voltage Proof Panel Seal Sealing inspection T e s t s T e s t No. 1-1 1-2 1-6 2-2 2-5 11-1

14、6-4 6-1 9-1 8 4-1 3-1 .9-1 8 4-1 3-1 14 10-2 5-1 5-3 5-2 10-1 1-6 3-1 13-1 14 Group D (every 36 months) Strength of Mounting Bushing 6-2 Strength of Screw Mounting 6-3 immersion in Solvents 15-1 Random V i bra ti on 5-4 O p r a t ing Character istics 1-6 Voltage PE-QOE 3-1 D or ND ND ND ND ND ND D D

15、 D D D D ND D D D ND D ND D D ND D ND ND D D D D D D ND ND t.s. 2 2 2 2 4 n.a. nea. n.a. 4 1 4 1 i4 1 i4 1 14 1 i4 1 4 1 i4 1 i4 1 4 n.a. n.a. 4 4 4 4 4 4 4 4 4 n.a. n.a. n.a. 4 4 1 Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=IH

16、S Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 01:41:03 MDTNo reproduction or networking permitted without license from IHS -,-,- E I A 520D000 87 = 323Yb00 0073550 Y EIA-520D000 Page 11 T e s t Methods and T e s t Groups ( T e s t Frequency) Group E (every 36 months) Capacitan

17、ce Contact Bounce Mec han i c a 1 Endurance Capacitance Operating Character ist ics Panel Seal Sealing Group F (every 36 months) S a l t Spray Group G (every 36 months) Fungus Resistance Group H (every 36 months) F1 ammab i 1 i t y Group K (every 36 months) Fluid Resistance Key: D ND t.s. t.d. g.d.

18、n.a. NOTES: i i31 4 1 i51 T e s t No . 17-1 1-7 7-1 17-1 12-1 13-1 1 4 D o r ND ND ND D ND ND D D Level “CIt 151 t.s. t.d. g.d. 3 10-5 D n.a. 10-4 D n.a. 16 15-2 n.a. n.a. = destructive test = non-destructive test = minimum number of test samples = maximum permissible defective u n i t s per test =

19、maximum permissible defective u n i t s per group = testing is not applicable i f no changes have been made t o t h e design or manufacturing process The r e s i l i e n t and hermetic seal tests may be performed as in- process inspections, and t h e acceptance inspection may then be limited t o t h

20、 e watertight test f o r gross leaks. The electrical endurance test s h a l l be limited to the maximum current raing a t standard atmospheric conditions The appropriate electrical endurance test(s) s h a l l be selected based upon t h e specified electrical ratings. The q u a l i t y of test specim

21、ens s h a l l be t h e same as required for q u a l i f i c a t i o n approval tests. Assessment level C per paragraph 3.4 i n EIA-5200000, with the l i s t e d Inspection Levels ( I L ) and Acceptable Quality Level (AQL) , is t h e miniinum acceptable level. Additional, higher l e v l e s can be de

22、veloped, as required for s p e c i f i c Detail Specifications. /-7 Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 01:41:03 MDTNo reproduction or networking per

23、mitted without license from IHS -,-,- EIA 520D000 87 i 3234b00 0073551 b EIA-520D000 Page 1 2 , 4.0 TEST METHODS & REQUIREMENTS This section supplements t h e test methods and requirements of EIA-5200000. 4.1 Voltage Proof The t e s t i n g s h a l l be per test 3-1 of EIA-5200000. The following d e

24、 t a i l s shall apply: Switch Voltage Rating Voltage Proof T e s t Voltage less than 50 v o l t s no less than 250 v o l t s 50 t o 250 v o l t s 1000 volts ac greater than 250 v o l t s 500 v o l t s a6 Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under licen

25、se with ECA Licensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 01:41:03 MDTNo reproduction or networking permitted without license from IHS -,-,- E I A 520D000 87 m 323YbOO 0073552 8 m EIA-520D000 Page 13 APPENDIX A Toggle, Paddle and Rocker Terminology The following ter

26、minology is common t o these switches. Toggle Switch: A switch manually operated by moving a projecting lever through a small arc. Paddle Switch: A switch manually operated by moving a projecting paddle lever through a small arc. Rocker Switch: A switch manually operated by moving a projecting rocke

27、r button through a small arc . Position: ( A mechanical location referring t o actuator position.) A s e t t i n g of the operator results i n a p a r t i c u l a r circuit condition. A position may be momentary o r maintained when the externally applied actuating force is removed. Operating Force:

28、The externally applied force required t o move t h e switch actuator from one position to an adjacent position. O Throw: Any toggle position where a moving contact(s) makes contact with a stationary contact(s) . A single-throw switch makes contact i n only one operator position. A double-throw switc

29、h makes contact i n two Oper a t o r pos i t ions. Electrical Ratings: The combinations of voltage and c u r r e n t under which the switch s h a l l operate s a t i s f a c t o r i l y under specified conditions for testing. Copyright Electronic Components, Assemblies & Materials Association Provided by IHS under license with ECA Licensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/30/2007 01:41:03 MDTNo reproduction or networking permitted without license from IHS -,-,-