EN-60335-2-9-2003-A2-2007.pdf

上传人:哈尼dd 文档编号:3755959 上传时间:2019-09-22 格式:PDF 页数:35 大小:331.24KB
返回 下载 相关 举报
EN-60335-2-9-2003-A2-2007.pdf_第1页
第1页 / 共35页
EN-60335-2-9-2003-A2-2007.pdf_第2页
第2页 / 共35页
EN-60335-2-9-2003-A2-2007.pdf_第3页
第3页 / 共35页
EN-60335-2-9-2003-A2-2007.pdf_第4页
第4页 / 共35页
EN-60335-2-9-2003-A2-2007.pdf_第5页
第5页 / 共35页
亲,该文档总共35页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《EN-60335-2-9-2003-A2-2007.pdf》由会员分享,可在线阅读,更多相关《EN-60335-2-9-2003-A2-2007.pdf(35页珍藏版)》请在三一文库上搜索。

1、EUROPEAN STANDARD EN 60335-2-9: 2003+A2 NORME EUROPENNE +A12 November 2007 EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 105

2、0 Brussels 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60335-2-9:2003 ICS 13.120; 97.040.50 Supersedes EN 60335-2-9:1995 + A1:1998 + A2:2000 + A11:2000 + A12:2002 + A13:2002 English version Household and similar electrica

3、l appliances Safety Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances (IEC 60335-2-9:2002, modified) Appareils lectrodomestiques et analogues Scurit Partie 2-9: Rgles particulires pour les grils, grille-pain et appareils de cuisson mobiles analogues (CEI

4、60335-2-9:2002, modifie) Sicherheit elektrischer Gerte fr den Hausgebrauch und hnliche Zwecke Teil 2-9: Besondere Anforderungen fr Grillgerte, Brotrster und hnliche ortsvernderliche Kochgerte (IEC 60335-2-9:2002, modifiziert) This European Standard was approved by CENELEC on 2003-03-01. CENELEC memb

5、ers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applicati

6、on to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat h

7、as the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Pola

8、nd, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Foreword The text of document 61/2100/FDIS, future fifth edition of IEC 60335-2-9, prepared by the IEC Technical Committee 61, was submitted to the IEC-CENELEC parallel vote. A proposal for an amendment, document CLC/TC

9、 61(SEC)1371, was discussed during the Kista meeting of CENELEC TC 61 in May 2002, when it was decided to submit a draft amendment prA11 to the formal vote. As a result of the Kista meeting, a draft amendment prAA containing the relevant existing common modifications was also submitted to the formal

10、 vote. The texts of the FDIS, prA11 and prAA were approved by CENELEC as a new edition of EN 60335-2-9 on 2003-03-01. This European Standard replaces EN 60335-2-9:1995 + A1:1998 + A2:2000 + A11:2000 + A12:2002 + A13:2002. The following dates are applicable: - latest date by which the EN has to be im

11、plemented at national level by publication of an identical national standard or by endorsement (dop) 2004-03-01 - date on which national standards conflicting with the EN have to be withdrawn (dow) 2006-03-01 This part 2 has to be used in conjunction with EN 60335-1, Household and similar electrical

12、 appliances Safety Part 1: General requirements. It was established on the basis of the 2002 edition of that standard. Amendments and revisions of Part 1 have also to be taken into account and the dates when such changes become applicable will be stated in the relevant amendment or revision of Part

13、1. This part 2 supplements or modifies the corresponding clauses of EN 60335-1, so as to convert it into the European Standard: Safety requirements for electric grills, toasters and similar portable cooking appliances. When a particular subclause of Part 1 is not mentioned in this part 2, that subcl

14、ause applies as far as is reasonable. When this standard states “addition“, “modification“ or “replacement“, the relevant text of Part 1 is to be adapted accordingly. NOTE 1 The following numbering system is used: - subclauses, tables and figures that are numbered starting from 101 are additional to

15、 those in Part 1; - unless notes are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including those in a replaced clause or subclause; - additional annexes are lettered AA, BB, etc.; -subclauses, notes and annexes that are additional to those in the IEC standard

16、are prefixed with the letter Z. NOTE 2 The following print types are used: -requirements: in roman type; -test specifications: in italic type; - notes: in small roman type. Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and the associated no

17、un are also in bold. There are no special national conditions causing a deviation from this European Standard, other than those listed in Annex ZA to EN 60335-1. There are no national deviations from this European Standard, other than those listed in Annex ZB to EN 60335-1. _ EN 60335-2-9:2003+A2+A1

18、2:2007- 2 - Introduction An investigation by CENELEC TC 61 has shown that all risks from products within the scope of this standard are fully covered by the Low Voltage Directive, 73/23/EEC. For products having mechanical moving parts, a risk assessment in accordance with the Machinery Directive, 98

19、/37/EC, has shown that the risks are mainly of electrical origin and consequently this directive is not applicable. However, the relevant essential safety requirements of the Machinery Directive are covered by this standard together with the principal objectives of the Low Voltage Directive. _ Endor

20、sement notice The text of the International Standard IEC 60335-2-9:2002 was approved by CENELEC as a European Standard with agreed common modifications . Foreword to amendment A1 The text of document 61/2535/FDIS, future amendment 1 to IEC 60335-2-9:2002, prepared by the IEC Technical Committee 61,

21、Safety of household and similar electrical appliances, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to EN 60335-2-9:2003 on 2004-03-01. The following dates are applicable: - latest date by which the amendment has to be implemented at national level by pu

22、blication of an identical national standard or by endorsement (dop) 2004-12-01 - date on which national standards conflicting with the amendment have to be withdrawn (dow) 2007-03-01 This amendment supplements or modifies the corresponding clauses of EN 60335-2-9:2003. There are no special national

23、conditions causing a deviation from this amendment. There are no national deviations from this amendment. NOTE In this document, p is used in the margin to indicate instructions for preparing the printed version. _ Endorsement notice The text of amendment 1:2004 to the International Standard IEC 603

24、35-2-9:2002 was approved by CENELEC as an amendment to the European Standard without any modification. EN 60335-2-9:2003+A2+A12:2007- 3 - Foreword to amendment A2 The text of document 61/2946/FDIS, future amendment 2 to IEC 60335-2-9:2002, prepared by IEC Technical Committee 61, Safety of household

25、and similar electrical appliances, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to EN 60335-2-9:2003 on 2006-04-01. The following dates are applicable: - latest date by which the amendment has to be implemented at national level by publication of an iden

26、tical national standard or by endorsement (dop) 2007-01-01 - date on which national standards conflicting with the amendment have to be withdrawn (dow) 2009-04-01 This amendment supplements or modifies the corresponding clauses of EN 60335-2-9:2003. As a consequence of endorsing amendment 2:2006 to

27、IEC 60335-2-9:2002, the common modifications in EN 60335-2-9:2003 are replaced by IEC text and therefore withdrawn, with the exception of the addition of 19.11.2 which remains valid. There are no special national conditions causing a deviation from this amendment. There are no national deviations fr

28、om this amendment. _ Endorsement notice The text of amendment 2:2006 to the International Standard IEC 60335-2-9:2002 was approved by CENELEC as an amendment to the European Standard without any modification. _ Foreword to amendment A12 A proposal to amend EN 60335-2-9:2003, document CLC/TC 61(SEC)1

29、553, was discussed during the Malaga meeting of CENELEC TC 61 in June 2006, when it was decided to submit a draft for an amendment to the Unique Acceptance Procedure. The draft was circulated in February 2007 and was approved by CENELEC as amendment A12 to EN 60335-2-9:2003 on 2007-10-01. The follow

30、ing dates are applicable: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-10-01 date on which national standards conflicting with the amendment have to be withdrawn (dow) 2010-10-01 _ EN 60335-2-9:2003+

31、A2+A12:2007- 4 - CONTENTS INTRODUCTION.6 1 Scope 7 2 Normative references .8 3 Definitions8 4 General requirement.11 5 General conditions for the tests 11 6 Classification12 7 Marking and instructions.12 8 Protection against access to live parts 14 9 Starting of motor-operated appliances.14 10 Power

32、 input and current14 11 Heating 15 12 Void .18 13 Leakage current and electric strength at operating temperature.18 14 Transient overvoltages .18 15 Moisture resistance 18 16 Leakage current and electric strength .19 17 Overload protection of transformers and associated circuits 20 18 Endurance20 19

33、 Abnormal operation 20 20 Stability and mechanical hazards22 21 Mechanical strength .22 22 Construction.23 23 Internal wiring.25 24 Components.25 25 Supply connection and external flexible cords .26 26 Terminals for external conductors .26 27 Provision for earthing26 28 Screws and connections .26 29

34、 Clearances, creepage distances and solid insulation .27 30 Resistance to heat and fire .27 31 Resistance to rusting27 32 Radiation, toxicity and similar hazards 28 Annexes .34 Bibliography .35 Figure 101 Examples of appliances 29 Figure 102 Load for testing rotating spits30 Figure 103 Vessel for te

35、sting hotplates.31 Figure 104 Vessel for testing induction hotplates 31 Table 101 Quantity of liquid in the vessel .9 Figure Z101 Probe for measuring flat surface temperatures 32 Figure Z102 Projection of the accessible part of a handle 32 Figure Z103 Front view of appliance with identification of e

36、xcluded areas33 Table Z101 Temperature rise limits for surfaces .17 EN 60335-2-9:2003+A2+A12:2007- 5 - INTRODUCTION It has been assumed in the drafting of this International Standard that the execution of its provisions is entrusted to appropriately qualified and experienced persons. This standard r

37、ecognizes the internationally accepted level of protection against hazards such as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal use taking into account the manufacturers instructions. ?It also covers abnormal situations that can be expected in practice

38、 and takes into account the way in which electromagnetic phenomena can affect the safe operation of appliances.? This standard takes into account the requirements of IEC 60364 as far as possible so that there is compatibility with the wiring rules when the appliance is connected to the supply mains.

39、 However, national wiring rules may differ. If an appliance within the scope of this standard also incorporates functions that are covered by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as is reasonable. If applicable, the influence of one function

40、 on the other is taken into account. This standard is a product family standard dealing with the safety of appliances and takes precedence over horizontal and generic standards covering the same subject. An appliance that complies with the text of this standard will not necessarily be considered to

41、comply with the safety principles of the standard if, when examined and tested, it is found to have other features which impair the level of safety covered by these requirements. An appliance employing materials or having forms of construction differing from those detailed in the requirements of thi

42、s standard may be examined and tested according to the intent of the requirements and, if found to be substantially equivalent, may be considered to comply with the standard. EN 60335-2-9:2003+A2+A12:2007- 6 - HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES SAFETY Part 2-9: Particular requirements for g

43、rills, toasters and similar portable cooking appliances 1 Scope This clause of Part 1 is replaced by the following. This International Standard deals with the safety of electric portable appliances for house- hold purposes that have a cooking function such as baking, roasting and grilling, their rat

44、ed voltage being not more than 250 V. NOTE 101 Examples of appliances that are within the scope of this standard are barbecues for indoor use; ? breadmakers;? contact grills (griddles); cookers; food dehydrators; hotplates; portable ovens; raclette grills; radiant grills; roasters; rotary grills; ro

45、tisseries; toasters; waffle irons; Examples are illustrated in Figure 101. As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account the use of appliance

46、s by young children or infirm persons without supervision; playing with the appliance by young children. NOTE 102 Attention is drawn to the fact that for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary; in many countries additional r

47、equirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities. NOTE 103 This standard does not apply to stationary ovens and stationary grills (IEC 60335-2-6); warming plates (IEC 60335-2-12); frying pans and d

48、eep fat fryers (IEC 60335-2-13); microwave ovens (IEC 60335-2-25); barbecues for outdoor use (IEC 60335-2-78); appliances intended for commercial catering; appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust,

49、 vapour or gas). EN 60335-2-9:2003+A2+A12:2007- 7 - 2 Normative references ?This clause of Part 1 is applicable except as follows. Addition: IEC 60068-2-52, Environmental testing Part 2: Tests Test Kb: Salt mist, cyclic (sodium chloride solution)? ?ISO 3864-1, Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs in workplaces and public areas? 3 Definitions This cla

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1