BS-ISO-6020-1-2007.pdf

上传人:爱问知识人 文档编号:3756272 上传时间:2019-09-22 格式:PDF 页数:22 大小:471.62KB
返回 下载 相关 举报
BS-ISO-6020-1-2007.pdf_第1页
第1页 / 共22页
BS-ISO-6020-1-2007.pdf_第2页
第2页 / 共22页
BS-ISO-6020-1-2007.pdf_第3页
第3页 / 共22页
BS-ISO-6020-1-2007.pdf_第4页
第4页 / 共22页
BS-ISO-6020-1-2007.pdf_第5页
第5页 / 共22页
亲,该文档总共22页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《BS-ISO-6020-1-2007.pdf》由会员分享,可在线阅读,更多相关《BS-ISO-6020-1-2007.pdf(22页珍藏版)》请在三一文库上搜索。

1、BRITISH STANDARD BS ISO 6020-1:2007 Hydraulic fluid power Mounting dimensions for single rod cylinders, 16 MPa (160 bar) series Part 1: Medium series ICS 23.100.20 ? Licensed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c)

2、BSI BS ISO 6020-1:2007 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2007 BSI 2007 ISBN 978 0 580 55042 3 National foreword This British Standard is the UK implementation of ISO 6020-1:2007. It supersedes BS ISO 6020-1:1998 and B

3、S ISO 8135:1999, which are withdrawn. The UK participation in its preparation was entrusted by Technical Committee MCE/18, Fluid power systems and components, to Panel MCE/18/-/3, Cylinders. A list of organizations represented on this committee can be obtained on request to its secretary. This publi

4、cation does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard cannot confer immunity from legal obligations. Amendments issued since publication Amd. No. DateComments Licensed Copy: London South Ba

5、nk University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI Reference number ISO 6020-1:2007(E) INTERNATIONAL STANDARD ISO 6020-1 Third edition 2007-08-15 Hydraulic fluid power Mounting dimensions for single rod cylinders, 16 MPa (160 bar) series Part

6、1: Medium series Transmissions hydrauliques Dimensions dinterchangeabilit des vrins 16 MPa (160 bar) simple tige Partie 1: Srie moyenne BS ISO 6020-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI ii Lice

7、nsed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI iii Contents Page Foreword iv Introduction v 1 Scope 1 2 Normative references1 3 Terms and definitions .2 4 Dimensions.2 5 Bore sizes.2 6 Stroke tolerances.2 7 Mounti

8、ng types 2 8 Piston rod characteristics.3 9 Identification statement (reference to this part of ISO 6020) .3 Bibliography12 BS ISO 6020-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI iv Foreword ISO (th

9、e International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committ

10、ee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechn

11、ical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member

12、bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying

13、any or all such patent rights. ISO 6020-1 was prepared by Technical Committee ISO/TC 131, Fluid power systems, Subcommittee SC 3, Cylinders. This third edition cancels and replaces the second edition (ISO 6020-1:1998) and ISO 8135:1999, which have been technically revised. ISO 6020 consists of the f

14、ollowing parts, under the general title Hydraulic fluid power Mounting dimensions for single rod cylinders, 16 MPa (160 bar) series: Part 1: Medium series Part 2: Compact series Part 3: Compact series with bores from 250 mm to 500 mm BS ISO 6020-1:2007 Licensed Copy: London South Bank University, Lo

15、ndon South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI v Introduction In hydraulic fluid power systems, power is transmitted and controlled through a liquid under pressure within an enclosed circuit. One component of such systems is the fluid power cylinder. This

16、is a device that converts power into linear mechanical force and motion. It consists of a movable element, i.e. a piston and piston rod, operating within a cylindrical bore. BS ISO 6020-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 20

17、07, Uncontrolled Copy, (c) BSI blank Licensed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 1 Hydraulic fluid power Mounting dimensions for single rod cylinders, 16 MPa (160 bar) series Part 1: Medium series 1 Scope T

18、his part of ISO 6020 establishes metric mounting dimensions for medium series cylinders, 16 MPa 160 bar 1), as required for interchangeability of commonly used hydraulic cylinders. The medium series dimensions are applicable to round head cylinders with bores from 25 mm to 200 mm and to both round a

19、nd square head cylinders with bores larger than 200 mm, thus allowing a wider range of applications. NOTE This part of ISO 6020 allows manufacturers of hydraulic equipment flexibility in the design of 16 MPa (160 bar) cylinders and does not restrict technical development; however, it does provide ba

20、sic guidelines. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1179-1

21、, Connections for general use and fluid power Ports and stud ends with ISO 228-1 threads with elastomeric or metal-to-metal sealing Part 1: Threaded ports ISO 3320:1987, Fluid power systems and components Cylinder bores and pistons rod diameters Metric series ISO 4395, Fluid power systems and compon

22、ents Cylinders Piston rod thread dimensions and types ISO 5598, Fluid power systems and components Vocabulary ISO 6099:2001, Fluid power systems and components Cylinders Identification code for mounting dimensions and mounting types ISO 6149-1, Connections for hydraulic fluid power and general use P

23、orts and stud ends with ISO 261 metric threads and O-ring sealing Part 1: Ports with truncated housing for O-ring seal ISO 6162-1, Hydraulic fluid power Flange connectors with split or one-piece flange clamps and metric or inch screws Part 1: Flange connectors for use at pressures of 3,5 MPa (35 bar

24、) to 35 MPa (350 bar), DN 13 to DN 127 ISO 6162-2, Hydraulic fluid power Flange connectors with split or one-piece flange clamps and metric or inch screws Part 2: Flange connectors for use at pressures of 35 MPa (350 bar) to 40 MPa (400 bar), DN 13 to DN 51 1) 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/m

25、m2. BS ISO 6020-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 2 ISO 6164, Hydraulic fluid power Four-screw, one-piece square-flange connections for use at pressures of 25 MPa and 40 MPa (250 bar and 40

26、0 bar) ISO 8132, Hydraulic fluid power Single rod cylinders, 16 MPa (160 bar) medium and 25 MPa (250 bar) series Mounting dimensions for accessories 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 5598 apply. 4 Dimensions 4.1 The mounting dimensions

27、for cylinders manufactured in accordance with this part of ISO 6020 shall be selected from Figures 1 to 6 and Tables 1 to 6 inclusive. 4.2 The dimensions for ports and flanges shall be selected from Table 7 and the relevant International Standards cited therein. 4.3 All dimensions and mounting types

28、 in this part of ISO 6020 are labelled with codes in accordance with ISO 6099. 5 Bore sizes This part of ISO 6020 covers the following bore sizes, expressed in millimetres, in accordance with ISO 3320:1987, Table 1: 25 32 40 50 63 80 100 125 160 200 250 320 400 500 6 Stroke tolerances Tolerances on

29、stroke shall be in accordance with Table 9. 7 Mounting types This part of ISO 6020 includes the following mounting types, identified in accordance with ISO 6099:2001, Table 2: a) MF 1 Head, rectangular flange; b) MF 2 Cap, rectangular flange; c) MF 3 Head, circular flange; d) MF 4 Cap, circular flan

30、ge; e) MP 3 Cap, fixed plain eye; f) MP 4 Cap, detachable plain eye; g) MP 5 Cap, fixed eye with spherical bearing; h) MP 6 Cap, detachable eye with spherical bearing; i) MS 2 Side lugs; j) MT 4 Intermediate fixed or movable trunnion (male). BS ISO 6020-1:2007 Licensed Copy: London South Bank Univer

31、sity, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 3 8 Piston rod characteristics 8.1 This part of ISO 6020 covers piston rods that have a shouldered male thread end; see Figure 1 and Table 1 for basic dimensions. 8.2 For rod end types, see ISO 4395. 8

32、.3 Accessory mounting dimensions shall be selected in accordance with ISO 8132. 9 Identification statement (reference to this part of ISO 6020) It is strongly recommended to manufacturers who have chosen to conform to this part of ISO 6020 that the following statement be used in test reports, catalo

33、gues and sales literature: “Medium series hydraulic single rod cylinders for use at 16 MPa (160 bar) have been selected in accordance with ISO 6020-1:2007, Hydraulic fluid power Mounting dimensions for single rod cylinders, 16 MPa (160 bar) series Part 1: Medium series.” NOTE Rod end types are contr

34、olled by ISO 4395. Figure 1 General dimensions BS ISO 6020-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 4 Table 1 General dimensions Dimensions in millimetres Bore Rod ZJ a KK A Y a PJ a D OH b VE WF

35、a MM 6g max. max. max. 14 M12 1,25 16 M12 1,25 16 25 18 150 M14 1,5 18 58 77 56 25,5 15 28 18 M14 1,5 18 M14 1,5 18 32 22 170 M16 1,5 22 64 89 67 30 19 32 22 M16 1,5 22 M16 1,5 22 40 28 190 M20 1,5 28 71 97 78 35 19 32 28 M20 1,5 28 M20 1,5 28 50 36 205 M27 2 36 72 111 95 44 24 38 36 M27 2 36 M27 2

36、36 63 45 224 M33 2 45 82 117 116 54 29 45 45 M33 2 45 M33 2 45 80 56 250 M42 2 56 91 134 130 62 36 54 56 M42 2 56 M42 2 56 100 70 300 M48 2 63 108 162 158 75 37 57 70 M48 2 63 M48 2 63 125 90 325 M64 3 85 121 174 192 92 37 60 90 M64 3 85 M64 3 85 160 110 370 M80 3 95 143 191 238 115 41 66 110 M80 3

37、95 M80 3 95 200 140 450 M100 3 112 190 224 285 138 45 75 140 M100 3 112 M100 3 112 250 180 550 M125 4 125 365 64 96 180 M125 4 125 M125 4 125 320 220 660 M160 4 160 455 71 108 220 M160 4 160 M160 4 160 400 280 740 M200 4 200 565 90 130 280 M200 4 200 M200 4 200 500 360 890 M250 6 250 645 110 163 NOT

38、E If other piston rod diameters or other threads are required, use those identified in ISO 3320 and ISO 4395. a Tolerances for dimensions ZJ, WF, Y and PJ are dependent on stroke; see Table 8. b Dimension OH is optional and only pertains to threaded ports. BS ISO 6020-1:2007 Licensed Copy: London So

39、uth Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 5 a Optional. Figure 2 MF 1 Head, rectangular flange and MF 2 Cap, rectangular flange Table 2 Dimensions of rectangular flange mounting types MF 1 and MF 2 Dimensions in millimetres Bore

40、 FB TF R VD ZB BA, B UF E MF H13 js13 js13 min. W a ZF a max. H8/f8 max. max. js13 25 6,6 69,2 28,7 3 16 162 158 32 85 60 12 32 9 85 35,2 3 16 186 178 40 105 70 16 40 9 98 40,6 3 16 206 198 50 115 80 16 50 11 116,4 48,2 4 18 225 213 60 140 100 20 63 13,5 134 55,5 4 20 249 234 70 160 120 25 80 17,5 1

41、52,5 63,1 4 22 282 260 85 185 135 32 100 22 184,8 76,5 5 25 332 310 106 225 160 32 125 22 217,1 90,2 5 28 357 335 132 255 195 32 a Tolerances for dimensions W and ZF are dependent on stroke; see Table 8. BS ISO 6020-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fr

42、i Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 6 a Optional. Figure 3 MF 3 Head, circular flange and MF 4 Cap, circular flange Table 3 Dimensions of circular flange mounting types MF 3 and MF 4 Dimensions in millimetres Bore FB FC VD ZB BA, B UC NF H13 js13 min. WC a ZP a max. H8/f8 ma

43、x. js13 25 8 6,6 75 3 16 162 158 32 90 12 32 8 9 92 3 16 186 178 40 110 16 40 8 9 106 3 16 206 198 50 125 16 50 8 11 126 4 18 225 213 60 150 20 63 8 13,5 145 4 20 249 234 70 170 25 80 8 17,5 165 4 22 282 260 85 195 32 100 8 22 200 5 25 332 310 106 240 32 125 8 22 235 5 28 357 335 132 275 32 160 8 22

44、 280 5 30 406 380 160 320 36 200 8 26 340 5 35 490 480 200 385 40 250 8 33 420 8 40 606 580 250 490 56 320 8 39 520 8 45 723 710 320 600 63 400 8 45 640 10 50 820 790 400 730 80 500 12 45 720 10 63 990 940 500 810 100 a Tolerances for dimensions WC and ZP are dependent on stroke; see Table 8. BS ISO

45、 6020-1:2007 Licensed Copy: London South Bank University, London South Bank University, Fri Nov 16 07:28:01 GMT+00:00 2007, Uncontrolled Copy, (c) BSI 7 Figure 4 MP 3 Cap, fixed plain eye, MP 4 Cap, detachable plain eye, MP 5 Cap, fixed eye with spherical bearing, MP 6 Cap, detachable eye with spher

46、ical bearing Table 4 Dimensions of cap eye mountings MP 3, MP 4, MP 5 and MP 6 Dimensions in millimetres Bore CD b CX c EW b or EX c L b or LT c MR b or MS c XC, XD, XO or XN a, d Tilting angle Z H9 H7 h12 min. max. min. 25 12 12 12 16 16 178 4 32 16 16 16 20 20 206 4 40 20 20 20 25 25 231 4 50 25 2

47、5 25 32 32 257 4 63 32 32 32 40 40 289 4 80 40 40 40 50 50 332 4 100 50 50 50 63 63 395 4 125 63 63 63 71 71 428 4 160 80 80 80 90 90 505 4 200 100 100 100 112 112 615 4 250 125 125 125 160 160 773 4 320 160 160 160 200 200 930 4 400 200 200 200 250 250 990 4 500 250 250 250 320 320 1210 4 a Toleran

48、ces for dimensions XC, XD, XO and XN are dependent on stroke; see Table 8. b The dimensions CD, EW, L and MR are valid for mounting types MP 3 and MP 4. c The dimensions CX, EX, LT and MS are valid for mounting types MP 5 and MP 6. d The dimension XC is valid for mounting type MP 3, the dimension XD is valid for mounting type MP 4, the dimension XO and XC are valid for mounting type MP 5, and the dimension XN is valid for mounting type MP 6. BS ISO 6020-1:2007 Licensed Copy: London South Bank University,