ETSI EN-300-086-2-V1.2.1-2008.pdf

上传人:哈尼dd 文档编号:3757062 上传时间:2019-09-22 格式:PDF 页数:18 大小:98.32KB
返回 下载 相关 举报
ETSI EN-300-086-2-V1.2.1-2008.pdf_第1页
第1页 / 共18页
ETSI EN-300-086-2-V1.2.1-2008.pdf_第2页
第2页 / 共18页
ETSI EN-300-086-2-V1.2.1-2008.pdf_第3页
第3页 / 共18页
ETSI EN-300-086-2-V1.2.1-2008.pdf_第4页
第4页 / 共18页
ETSI EN-300-086-2-V1.2.1-2008.pdf_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《ETSI EN-300-086-2-V1.2.1-2008.pdf》由会员分享,可在线阅读,更多相关《ETSI EN-300-086-2-V1.2.1-2008.pdf(18页珍藏版)》请在三一文库上搜索。

1、 ETSI EN 300 086-2 V1.2.1 (2008-09) Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Radio equipment with an internal or external RF connector intended primarily for analogue speech; Part 2: Harmonized EN co

2、vering essential requirements under article 3.2 of the R Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the E

3、TSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Forewo

4、rd This Harmonized European Standard (Telecommunications series) has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio spectrum Matters (ERM). The present document has been produced by ETSI in response to a mandate from the European Commission issued under Council Dir

5、ective 98/34/EC (as amended) i.2 laying down a procedure for the provision of information in the field of technical standards and regulations. The present document is intended to become a Harmonized Standard, the reference of which will be published in the Official Journal of the European Communitie

6、s referencing the Directive 1999/5/EC i.1 of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (“the R Radio equipment with an internal or external RF connector intended primarily for

7、 analogue speech, as identified below: Part 1: “Technical characteristics and methods of measurement“; Part 2: “Harmonized EN covering essential requirements under article 3.2 of the R mobile station (equipment fitted with an antenna connector, normally used in a vehicle or as a transportable); and

8、those hand portable stations: a) fitted with an antenna connector; or b) without an external antenna connector, but fitted with a permanent internal or a temporary internal 50 Radio Frequency (RF) connector which allows access to the transmitter output and the receiver input. Hand portable equipment

9、 without an external or internal RF connector and without the possibility of having a temporary internal 50 RF connector is not covered by the present document. NOTE: Hand portable equipment without an external or internal RF connector and without the possibility of having a temporary internal 50 RF

10、 connector is not covered by the present document (integral antenna equipment is covered by EN 300 296 i.4). 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For a specific reference, subsequent revisions do not

11、apply. Non-specific reference may be made only to a complete document or a part thereof and only in the following cases: - if it is accepted that it will be possible to use all future changes of the referenced document for the purposes of the referring document; - for informative references. Referen

12、ced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. ETSI ETSI EN 300 086-2 V1.2.1 (2008-09) 7 For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, th

13、e primary source of the referenced document should be cited, in order to ensure traceability. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network ad

14、dress, with the same punctuation and use of upper case and lower case letters. NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are indispensable for th

15、e application of the present document. For dated references, only the edition cited applies. For non-specific references, the latest edition of the referenced document (including any amendments) applies. 1 ETSI EN 300 086-1 (V1.3.1): “Electromagnetic compatibility and Radio spectrum Matters (ERM); L

16、and Mobile Service; Radio equipment with an internal or external RF connector intended primarily for analogue speech; Part 1: Technical characteristics and methods of measurement“. 2 ETSI TR 100 028 (all parts) (V1.4.1): “Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties

17、in the measurement of mobile radio equipment characteristics“. 2.2 Informative references The following referenced documents are not essential to the use of the ETSI deliverable but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the

18、referenced document (including any amendments) applies. i.1 Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R A guide to the production of candidate Harmoniz

19、ed Standards for application under the R Land Mobile Service; Radio equipment using integral antennas intended primarily for analogue speech“. 3 Definitions, symbols and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in EN 300 086-1 1 apply. 3

20、.2 Symbols For the purposes of the present document, the symbols given in EN 300 086-1 1 apply. 3.3 Abbreviations For the purposes of the present document, the abbreviations given in EN 300 086-1 1 apply. ETSI ETSI EN 300 086-2 V1.2.1 (2008-09) 8 4 Technical requirements specifications 4.1 Environme

21、ntal profile The technical requirements of the present document apply under the environmental profile for operation of the equipment, which shall be declared by the manufacturer of the equipment. The equipment shall comply with all the technical requirements of the present document at all times when

22、 operating within the boundary limits of the declared operational environmental profile. 4.2 Transmitter requirements 4.2.1 Frequency error 4.2.1.1 Definition The frequency error is defined in EN 300 086-1 1, clause 7.1.1. 4.2.1.2 Limit The frequency error shall not exceed the limits in EN 300 086-1

23、 1, clause 7.1.3. 4.2.1.3 Conformance Conformance tests as defined in clause 5.3.1 shall be carried out. 4.2.2 Transmitter power (conducted) 4.2.2.1 Definition The transmitter power (conducted) is defined in EN 300 086-1 1, clause 7.2.1. 4.2.2.2 Limit The transmitter power (conducted) shall not exce

24、ed the limits in EN 300 086-1 1, clause 7.2.3. 4.2.2.3 Conformance Conformance tests as defined in clause 5.3.2 shall be carried out. 4.2.3 Maximum effective radiated power 4.2.3.1 Definition The maximum effective radiated power is defined in EN 300 086-1 1, clause 7.3.1. 4.2.3.2 Limit The maximum e

25、ffective radiated power shall not exceed the limits in EN 300 086-1 1, clause 7.3.3. 4.2.3.3 Conformance Conformance tests as defined in clause 5.3.3 shall be carried out. ETSI ETSI EN 300 086-2 V1.2.1 (2008-09) 9 4.2.4 Adjacent and alternate channel power 4.2.4.1 Definition The adjacent and alterna

26、te channel power is defined in EN 300 086-1 1, clause 7.5.1. 4.2.4.2 Limit The adjacent and alternate channel power shall not exceed the limits in EN 300 086-1 1, clause 7.5.3. 4.2.4.3 Conformance Conformance tests as defined in clause 5.3.4 shall be carried out. 4.2.5 Unwanted emissions in the spur

27、ious domain 4.2.5.1 Definition The unwanted emissions in the spurious domain are defined in EN 300 086-1 1, clause 7.6.1. 4.2.5.2 Limit The unwanted emissions in the spurious domain shall not exceed the limits in EN 300 086-1 1, clause 7.6.4. 4.2.5.3 Conformance Conformance tests as defined in claus

28、e 5.3.5 shall be carried out. 4.2.6 Intermodulation attenuation 4.2.6.1 Definition The intermodulation attenuation is defined in EN 300 086-1 1, clause 7.7.1. 4.2.6.2 Limit The intermodulation attenuation shall not exceed the limits in EN 300 086-1 1, clause 7.7.3. 4.2.6.3 Conformance Conformance te

29、sts as defined in clause 5.3.6 shall be carried out. 4.3 Receiver requirements 4.3.1 Maximum usable receiver sensitivity 4.3.1.1 Definition The maximum usable receiver sensitivity is defined in EN 300 086-1 1, clause 8.1.1 (conducted) and clause 8.2.1 (field strength). In addition, for duplex equipm

30、ent (equipment providing simultaneous transmission and reception), the receiver desensitization is defined in EN 300 086-1 1, clause 9.1.1. ETSI ETSI EN 300 086-2 V1.2.1 (2008-09) 10 4.3.1.2 Limit The sensitivity shall not exceed the limits in EN 300 086-1 1, clause 8.1.3 (conducted) and clause 8.2.

31、3 (field strength). In addition, for duplex equipment (equipment providing simultaneous transmission and reception), the receiver desensitization shall meet the requirements of EN 300 086-1 1, clause 9.1.4. 4.3.1.3 Conformance Conformance tests as defined in clause 5.3.9 may be carried out. 4.3.2 Co

32、-channel rejection 4.3.2.1 Definition The co-channel rejection is defined in EN 300 086-1 1, clause 8.3.1. 4.3.2.2 Limit The co-channel rejection shall not exceed the limits in EN 300 086-1 1, clause 8.3.3. 4.3.2.3 Conformance Conformance tests as defined in clause 5.3.10 may be carried out. 4.3.3 A

33、djacent channel selectivity 4.3.3.1 Definition The adjacent channel selectivity is defined in EN 300 086-1 1, clause 8.4.1. 4.3.3.2 Limit The adjacent channel selectivity shall not exceed the limits in EN 300 086-1 1, clause 8.4.3. 4.3.3.3 Conformance Conformance tests as defined in clause 5.3.11 ma

34、y be carried out. 4.3.4 Spurious response rejection 4.3.4.1 Definition The spurious response rejection is defined in EN 300 086-1 1, clause 8.5.1. In addition, in the case of duplex equipment (equipment providing simultaneous transmission and reception), the receiver spurious response rejection is d

35、efined in EN 300 086-1 1, clause 9.2.1. 4.3.4.2 Limit The spurious response rejection shall not exceed the limits in EN 300 086-1 1, clause 8.5.4. In addition, in the case of duplex equipment (equipment providing simultaneous transmission and reception), the receiver spurious response rejection shal

36、l not exceed the limits in EN 300 086-1 1, clause 9.2.3. ETSI ETSI EN 300 086-2 V1.2.1 (2008-09) 11 4.3.4.3 Conformance Conformance tests as defined in clause 5.3.12 may be carried out. 4.3.5 Intermodulation response rejection 4.3.5.1 Definition The intermodulation response rejection is defined in E

37、N 300 086-1 1, clause 8.6.1. 4.3.5.2 Limit The intermodulation response rejection shall not exceed the limits in EN 300 086-1 1, clause 8.6.3. 4.3.5.3 Conformance Conformance tests as defined in clause 5.3.12 may be carried out. 4.3.6 Blocking or desensitization 4.3.6.1 Definition The blocking or de

38、sensitization is defined in EN 300 086-1 1, clause 8.7.1. 4.3.6.2 Limit The blocking or desensitization shall not exceed the limits in EN 300 086-1 1, clause 8.7.3. 4.3.6.3 Conformance Conformance tests as defined in clause 5.3.13 may be carried out. 4.3.7 Spurious radiations 4.3.7.1 Definition The

39、spurious radiations are defined in EN 300 086-1 1, clause 8.8.1. 4.3.7.2 Limit The spurious radiations shall not exceed the limits in EN 300 086-1 1, clause 8.8.4. 4.3.7.3 Conformance Conformance tests as defined in clause 5.3.8 shall be carried out. ETSI ETSI EN 300 086-2 V1.2.1 (2008-09) 12 5 Test

40、ing for compliance with technical requirements 5.1 Environmental conditions for testing Tests defined in the present document shall be carried out at representative points within the boundary limits of the declared operational environmental profile. Where technical performance varies subject to envi

41、ronmental conditions, tests shall be carried out under a sufficient variety of environmental conditions (within the boundary limits of the declared operational environmental profile) to give confidence of compliance for the affected technical requirements. 5.1.1 Normal and extreme test-conditions Me

42、asurements shall be made under normal test conditions, and also, where stated, under extreme test conditions. The test conditions and procedures shall be as specified in EN 300 086-1 1, clauses 5.3 to 5.5. 5.1.2 Test power source The test power source shall meet the requirements of EN 300 086-1 1, c

43、lause 5.2. 5.1.3 Choice of samples for test suites Measurement shall be performed, according to the present document, on samples of equipment defined in EN 300 086-1 1, clause 4.1. 5.2 Interpretation of the measurement results The interpretation of the results recorded in a test report for the measu

44、rements described in the present document shall be as follows: the measured value related to the corresponding limit shall be used to decide whether an equipment meets the requirements of the present document; the value of the measurement uncertainty for the measurement of each parameter shall be in

45、cluded in the test report; the value of the measurement uncertainty shall be, for each measurement, equal to or lower than the figures given in clause 10 (table 13) in EN 300 086-1 1. For the test methods, according to the present document, the measurement uncertainty figures shall be calculated in

46、accordance with TR 100 028 2 and shall correspond to an expansion factor (coverage factor) k = 1,96 or k = 2 (which provide confidence levels of respectively 95 % and 95,45 % in the case where the distributions characterizing the actual measurement uncertainties are normal (Gaussian). The particular

47、 expansion factor used for the evaluation of the measurement uncertainty shall be stated. The absolute measurement uncertainties are given in clause 10 (table 13) in EN 300 086-1 1. 5.3 Essential radio test suites Essential test suites are referred to in annex III of R it provides a statement of all

48、 the test procedures corresponding to those essential requirements by cross reference to (a) specific clause(s) in the present document or to (a) specific clause(s) in (a) specific referenced document(s); it qualifies each requirement to be either: - Unconditional: meaning that the requirement appli

49、es in all circumstances; or - Conditional: meaning that the requirement is dependent on the manufacturer having chosen to support optional functionality defined within the schedule; in the case of Conditional requirements, it associates the requirement with the particular optional service or functionality; it qualifies each test procedure to be either: - Essential: meaning that it is included with the Essential Radio Test Suite and therefore the requirement shall be

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1