IEC-TR-61305-6-2005.pdf

上传人:哈尼dd 文档编号:3770811 上传时间:2019-09-23 格式:PDF 页数:26 大小:508.88KB
返回 下载 相关 举报
IEC-TR-61305-6-2005.pdf_第1页
第1页 / 共26页
IEC-TR-61305-6-2005.pdf_第2页
第2页 / 共26页
IEC-TR-61305-6-2005.pdf_第3页
第3页 / 共26页
IEC-TR-61305-6-2005.pdf_第4页
第4页 / 共26页
IEC-TR-61305-6-2005.pdf_第5页
第5页 / 共26页
亲,该文档总共26页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《IEC-TR-61305-6-2005.pdf》由会员分享,可在线阅读,更多相关《IEC-TR-61305-6-2005.pdf(26页珍藏版)》请在三一文库上搜索。

1、 TECHNICAL REPORT IEC TR 61305-6 First edition 2005-05 Household high-fidelity audio equipment and systems Methods of measuring and specifying the performance Part 6: Listening tests on loudspeakers Single stimulus ratings and paired comparisons Reference number IEC/TR 61305-6:2005(E) Publication nu

2、mbering As from 1 January 1997 all IEC publications are issued with a designation in the 60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1. Consolidated editions The IEC is now publishing consolidated versions of its publications. For example, edition numbers 1.0, 1.1 and 1.2 ref

3、er, respectively, to the base publication, the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2. Further information on IEC publications The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the cont

4、ent reflects current technology. Information relating to this publication, including its validity, is available in the IEC Catalogue of publications (see below) in addition to new editions, amendments and corrigenda. Information on the subjects under consideration and work in progress undertaken by

5、the technical committee which has prepared this publication, as well as the list of publications issued, is also available from the following: IEC Web Site (www.iec.ch) Catalogue of IEC publications The on-line catalogue on the IEC web site (www.iec.ch/searchpub) enables you to search by a variety o

6、f criteria including text searches, technical committees and date of publication. On-line information is also available on recently issued publications, withdrawn and replaced publications, as well as corrigenda. IEC Just Published This summary of recently issued publications (www.iec.ch/online_news

7、/ justpub) is also available by email. Please contact the Customer Service Centre (see below) for further information. Customer Service Centre If you have any questions regarding this publication or need further assistance, please contact the Customer Service Centre: Email: custserviec.ch Tel: +41 2

8、2 919 02 11 Fax: +41 22 919 03 00 TECHNICAL REPORT IEC TR 61305-6 First edition 2005-05 Household high-fidelity audio equipment and systems Methods of measuring and specifying the performance Part 6: Listening tests on loudspeakers Single stimulus ratings and paired comparisons PRICE CODE IEC 2005 C

9、opyright - all rights reserved No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box

10、131, CH-1211 Geneva 20, Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch R For price, see current catalogue Commission Electrotechnique Internationale International Electrotechnical Commission 2 TR 61305-6 IEC:2005(E) CONTENTS FOREWORD.3 INTRODUC

11、TION.5 1 Scope.6 2 Normative references .6 3 Test preparation .6 3.1 Characteristics of the listening room6 3.2 Loudspeaker position and seat arrangement .7 3.3 Electrical requirements8 3.4 Level setting8 3.5 Listening levels for programmes8 3.6 Programme material8 3.7 Qualification and number of li

12、steners.8 3.8 Test duration.8 4 Single stimulus ratings .9 4.1 Test procedure9 4.2 Questionnaire9 4.3 Test sequence.10 4.4 Reliability of judgements .10 4.5 Variance analysis 11 4.6 Factor analysis11 4.7 Quality judgement .12 4.8 Representation of the results.12 4.9 Computer programs.13 5 Paired com

13、parisons14 5.1 Test procedure14 5.2 Test criteria.14 5.3 Test sequence.15 5.4 Number of contradictory judgements .15 5.5 Determination of the scale values15 5.6 Variance analysis 15 5.7 Factor analysis15 Annex A (informative) Example calculation for tests using paired comparison16 Bibliography20 TR

14、61305-6 IEC:2005(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ HOUSEHOLD HIGH-FIDELITY AUDIO EQUIPMENT AND SYSTEMS METHODS OF MEASURING AND SPECIFYING THE PERFORMANCE Part 6: Listening tests on loudspeakers Single stimulus ratings and paired comparisons FOREWORD 1) The International Electrotechni

15、cal Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this

16、end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Co

17、mmittee interested in the subject dealt with may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in

18、 accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from a

19、ll interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held

20、responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any dive

21、rgence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication.

22、 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property da

23、mage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this pu

24、blication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all

25、 such patent rights. The main task of IEC technical committees is to prepare International Standards. However, a technical committee may propose the publication of a technical report when it has collected data of a different kind from that which is normally published as an International Standard, fo

26、r example “state of the art“. IEC 61305-6, which is a technical report, has been prepared by IEC technical committee 100: Audio, video and multimedia systems and equipment The text of this technical report is based on the following documents: Enquiry draft Report on voting 100/855/DTR 100/905/RVC Fu

27、ll information on the voting for the approval of this technical report can be found in the report on voting indicated in the above table. 4 TR 61305-6 IEC:2005(E) The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the

28、IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual version of this publication may be issued at a later date. -,-,- TR 61305-6 IEC:2005(E) 5 I

29、NTRODUCTION This technical report gives recommendations for establishing, conducting and evaluating listening tests. The tests described in this report are to be performed in a room, the size and acoustical properties are similar to those of an average living room. Specific recommendations about the

30、 room size, acoustical properties, arrangement of loudspeakers and listeners, and environmental conditions are given. This technical report describes experimental procedures, including recommendations on the choice of programme material and the processing and presentation of the final data. It may b

31、e useful to consider some of the recommendations in AES 20. It should be understood that the topics of experimental design, execution and statistical analysis are complex, and that only the most general guidelines can be given. It is recommended that professionals with expertise of experimental desi

32、gn and statistics should be consulted. The use of multichannel formats, principally for domestic presentation of surround audio and cinema is becoming more usual. The procedures described in this report are applicable to any number of channels. If the number of loudspeakers to be tested is high, the

33、 paired comparison listening test is lengthy because each loudspeaker has to be compared with the other. A shorter method is the single stimulus rating. With this method, each object is judged once. The rating is almost independent of the loudspeaker range in test. Each object is rated absolutely, w

34、hereas a paired comparison provides a relative ranking of the order of the loudspeakers in test. Another technical report for listening test has been published as IEC 60268-13 and it is expected that the two technical reports should be combined in the maintenance work -,-,- 6 TR 61305-6 IEC:2005(E)

35、HOUSEHOLD HIGH-FIDELITY AUDIO EQUIPMENT AND SYSTEMS METHODS OF MEASURING AND SPECIFYING THE PERFORMANCE Part 6: Listening tests on loudspeakers Single stimulus ratings and paired comparisons 1 Scope This technical report applies to loudspeakers conforming to IEC 61305-5 and intended for home use. Th

36、e purpose of this report is, in addition to objective testing according to IEC 60268-5, to establish standards for comparison of the sound characteristics of various loudspeakers with each other. Two test procedures are described: single stimulus ratings; paired comparisons. The procedures described

37、 in this report are applicable to any number of channels. NOTE The test procedures are specified for stereo systems. They can be applied to multichannel systems accordingly. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated re

38、ferences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61305-5, High fidelity audio equipment and systems; Minimum performance requirements Part 5: Loudspeakers. IEC 60268-5, Sound system equipment Part

39、5: Loudspeakers. ISO 3382, Acoustics Measurement of the reverberation time of rooms with reference to other acoustical parameters. 3 Test preparation 3.1 Characteristics of the listening room The volume of the listening room shall be 80 m3 20 m3 with a room height of 2,75 m 0,25 m. The room should h

40、ave a rectangular floor plan, whereby the ratio of the sides to each other should not exceed 2:1. A square floor plan is not permitted. TR 61305-6 IEC:2005(E) 7 1,0 0,8 0,6 0,4 0,2 100 1 00010 000 400 T s f Hz IEC 635/05 Figure 1 Range limits for the reverberation time The reverberation time of the

41、room shall be within the range limits shown in Figure 1. The reverberation time shall not change by more than +25 % or 20 % within one octave in the range from 400 Hz to 8 kHz. The reverberation time is to be measured with noise in 1/3 - octave intervals with listeners present as laid down in ISO 33

42、82. Conversion of the reverberation time measured without listeners to one with listeners is permitted. Relevant room resonance resulting from furnishings shall be avoided. The distribution of the absorbing material should be as uniform as possible for all frequencies. In particular, parallel walls

43、shall not be allowed to reflect sound to a significantly higher degree than the other walls. This also applies to the floor and the ceiling of the listening room. The AF-rated mean level of noise in the testing room may not exceed a value of LAFm = 25 dB. 3.2 Loudspeaker position and seat arrangemen

44、t The loudspeaker shall be hidden behind an acoustically transparent screen to avoid influencing the listener by its design. The loudspeakers shall be located and listened to in the positions in which they are used normally (as recommended of the manufacturer). This means, for example, loudspeakers

45、designed for placement in shelves shall be placed in shelves or in an acoustically equivalent position. The distances from the floor and the ceiling shall correspond to usual positioning. Unless otherwise specified, the distance from the walls shall be at least 0,5 m. The loudspeakers shall be teste

46、d in the stereo mode. The angle between the imaginary lines joining the loudspeakers and the listener should be not less than 45 for each listener. The loudspeakers shall be positioned so that the stereo base is constant in each case. Only the two sets of stereo loudspeaker (paired comparison) or th

47、e set of stereo loudspeakers to be tested (single stimulus rating) may be arranged to prevent feedback from other loudspeakers. When the paired comparison procedure is used, the centre and height of the line between the loudspeakers of each set shall not vary more than is necessary. If several liste

48、ners participate simultaneously in one test, the seats should be arranged so that all listeners can see the loudspeakers directly when the screen is taken away. 8 TR 61305-6 IEC:2005(E) 3.3 Electrical requirements The loudspeakers shall be fed by equipment with characteristics that do not affect the

49、 test results. The system shall consist of a source, level adjustment, and a power amplifier with a low output impedance and sufficient power (that is, clipping may not occur even at the highest signal levels). The tone control is to be set to a flat position both on the equipment as well as on the loudspeakers. Other settings sh

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1