ISO-15512-1999.pdf

上传人:爱问知识人 文档编号:3775381 上传时间:2019-09-23 格式:PDF 页数:18 大小:152.37KB
返回 下载 相关 举报
ISO-15512-1999.pdf_第1页
第1页 / 共18页
ISO-15512-1999.pdf_第2页
第2页 / 共18页
ISO-15512-1999.pdf_第3页
第3页 / 共18页
ISO-15512-1999.pdf_第4页
第4页 / 共18页
ISO-15512-1999.pdf_第5页
第5页 / 共18页
亲,该文档总共18页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《ISO-15512-1999.pdf》由会员分享,可在线阅读,更多相关《ISO-15512-1999.pdf(18页珍藏版)》请在三一文库上搜索。

1、A Reference number ISO 15512:1999(E) INTERNATIONAL STANDARD ISO 15512 First edition 1999-07-01 Plastics Determination of water content Plastiques Dosage de leau ISO 15512:1999(E) ISO 1999 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in an

2、y form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Organization for Standardization Case postale 56 CH-1211 Genve 20 Switzerland Internetisoiso.ch Printed in Switzerland ii Contents 1 Scope1 2 Normat

3、ive references1 3 Method A Extraction with anhydrous methanol 2 4 Method B Water vaporization.4 5 Method C Manometric method.8 6 Test report12 -,-,- ISOISO 15512:1999(E) iii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO

4、member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, govern

5、mental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Di

6、rectives, Part 3. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. International Standard ISO 15512 was prepared by Techni

7、cal Committee ISO/TC 61, Plastics, Subcommittee SC 5, Physical-chemical properties. -,-,- INTERNATIONAL STANDARD ISOISO 15512:1999(E) 1 Plastics Determination of water content 1 Scope 1.1 This International Standard specifies methods for the determination of the water content of plastics in the form

8、 of granules and finished articles. These methods do not test for water absorption (kinetics and equilibrium) of plastics as measured by ISO 62. The methods are suitable for the determination of water content as low as the following levels: Method A0,1 % or better; Method B0,01 % or better; Method C

9、0,01 % or better. Water content is an important parameter for processing materials, and should remain below the level specified in the appropriate material standard. 1.2 Three alternative methods are specified in this International Standard. a) Method A is an extraction method using anhydrous methan

10、ol followed by a Karl-Fischer titration of the extracted water. It can be used for all plastics and is applicable to granules having a maximum size of 4 mm 4 mm 3 mm. b) Method B is a vaporization method using heated, dry air or nitrogen gas to evaporate the water, followed by a Karl-Fischer titrati

11、on of the collected water. It can be used for all plastics and is applicable to granules smaller than 4 mm 4 mm 3 mm. c) Method C is a manometric method. The water content is determined from the increase in pressure which results when the water is evaporated under a vacuum. This method is not applic

12、able to plastic samples containing volatile compounds, other than water, in amounts contributing significantly to the vapour pressure at room temperature. Checks for the presence of large amounts of volatile compounds should be carried out periodically, for example by gas chromatography. Such checks

13、 are particularly required for new types or grades of material. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this International Standard. For dated references, subsequent amendments to, or revisions of, an

14、y of these publications do not apply. However, parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative documen

15、t referred to applies. Members of ISO and IEC maintain registers of currently valid International Standards. ISO 62, Plastics Determination of water absorption. ISO 760:1978, Determination of water Karl Fischer method (General method). -,-,- ISO 15512:1999(E) ISO 2 3 Method A Extraction with anhydro

16、us methanol 3.1 Principle A test portion is extracted with anhydrous methanol and the extracted water determined by titration using the Karl Fischer method. 3.2 Reagents During the analysis, use only reagents of recognized analytical grade. 3.2.1 Methanol, anhydrous, having a water content less than

17、 0,1 % by mass. 3.2.2 Karl Fischer reagent, with an equivalence factor of approximately 3 mg/ml to 5 mg/ml of water. If the reagent is prepared, check its equivalence factor as specified in ISO 760. 3.3 Apparatus Ordinary laboratory apparatus and the following: 3.3.1 Glass flasks, 250 ml capacity, p

18、rovided with ground-glass or rubber stoppers. 3.3.2 Conical titration flasks, 150 ml capacity, with standard ground necks and provided with ground-glass stoppers. 3.3.3 Reflux condensers, with ground neck capable of being fitted on to the flasks (3.3.2) and on to the tubes (3.3.4). 3.3.4 Water-absor

19、ption tubes with ground joints, containing calcium chloride or other drying agent. 3.3.5 Electrical or hot-air heaters, for the flasks (3.3.2). 3.3.6 Pipettes, 50 ml capacity. (Automatic filling pipettes are acceptable.) 3.3.7 Woulfe bottles, with two tubes. 3.3.8 Curved or U-shaped water-absorption

20、 tubes, filled with calcium chloride. 3.3.9 Rubber pipette filler. 3.3.10 Pipette, 10 ml capacity. 3.3.11 Desiccator, containing calcium chloride. 3.3.12 Analytical balance, accurate to 0,2 mg. 3.3.13 Karl Fischer apparatus, for determining water content in accordance with ISO 760. 3.4 Preparation o

21、f test sample 3.4.1 Granules Take a representative sample of approximately 100 g. Put the sample into a pre-dried glass flask (3.3.1) and immediately close it with a stopper. NOTE It is desirable to pre-dry the container in an oven, then cool it over a suitable water absorbent, for instance silica g

22、el. 3.4.2 Finished articles Cut or saw the sample into pieces of appropriate size, i.e. having a maximum size of 4 mm 4 mm 3 mm. Proceed quickly to minimize moisture absorption. ISOISO 15512:1999(E) 3 3.5 Procedure 3.5.1 Precautions Due to the low quantities of water measured, maximum care shall be

23、exercised at all times to avoid contaminating the sample with water from the sample container, the atmosphere or transfer equipment. Hygroscopic resin samples shall be protected from the atmosphere. 3.5.2 Preparation of test portions Conduct the test on two test portions from the same sample. Use te

24、st portions containing 10 mg to 20 mg of water based on the estimated water content of the sample. 3.5.3 Determination 3.5.3.1 Carefully dry the apparatus. 3.5.3.2 Weigh each test portion to the nearest 1 mg into a conical titration flask (3.3.2) fitted with a ground-glass stopper. Pipette 50 ml (3.

25、3.6) of anhydrous methanol (3.2.1) into the conical flask containing the test portion. At the same time, add 50 ml of anhydrous methanol to another conical flask for a blank test. Stopper the flasks. Keep the stoppered flasks in the desiccator (3.3.11) pending continuation of the test. 3.5.3.3 Unsto

26、pper the flasks and quickly attach them to reflux condensers (3.3.3) fitted with calcium chloride tubes (3.3.4). Reflux the contents of the conical flasks for 3 h, then leave them for 45 min to cool to room temperature. Separate the flasks from the condensers, quickly stopper them and place them in

27、the desiccator. 3.5.3.4 Use the Karl Fischer apparatus (3.3.13) to titrate the contents of each flask with Karl Fischer reagent (3.2.2). 3.6 Expression of results 3.6.1 The water content w, expressed as a percentage by mass, for each of the two determinations is given by the following formula: () w

28、VVT m = 12 100 where: V1is the volume, expressed in millilitres, of Karl Fischer reagent used for the determination; V2is the volume, expressed in millilitres, of Karl Fischer reagent used for the blank test; Tis the water equivalent, expressed in grams of water per millilitre of reagent, of Karl Fi

29、scher reagent; mis the mass, in grams, of the test portion. 3.6.2 The two values for the water content shall not differ by more than 10 % relative or 0,02 % absolute, whichever is the greater. If the difference is greater, repeat the measurements until acceptable consecutive values are obtained and

30、discard all unacceptable results. 3.6.3 The result is expressed as the average of these two determinations, rounded to the nearest 0,01 % by mass. 3.7 Precision The precision of this test method is not known because interlaboratory data are not available. If and when interlaboratory data are obtaine

31、d, a precision statement will be added at a subsequent revision. ISO 15512:1999(E) ISO 4 4 Method B Water vaporization 4.1 Principle The sample is weighed then placed in an oven. The water contained in the test portion is vaporized and carried to the titration cell by a dry nitrogen carrier gas. The

32、 water is then titrated using the coulometric Karl Fischer method. This method is based on the reduction of iodine by sulfur dioxide in the presence of water to form sulfur trioxide and hydroiodic acid as follows: I2 + SO2 + H2O 2HI + SO3 Unlike the conventional Karl Fisher reagents that include iod

33、ine, the coulometric technique generates the iodine electrolytically from iodide 2I- I2 + 2e- with 10,71 C of generating current corresponding to 1 mg of water in accordance with Faradays law. 4.2 Reagents During the analysis, use only reagents of recognized analytical grade and only distilled water

34、 or water of equivalent purity. 4.2.1 Anode solution, containing iodide ions (to generate iodine in the reaction mixture), pyridine (or another base such as dipyridylpropane, alkylaminopyridine, imidazole or diethanolamine), sulfur dioxide and methanol (or another suitable organic solvent), prepared

35、 in accordance with the equipment manufacurers instructions. 4.2.2 Cathode solution, containing a suitable salt in methanol (or another suitable organic solvent), prepared in accordance with the equipment manufacturers instructions. NOTE For the anode (4.2.1) and cathode solutions (4.2.2), hydranal

36、Karl Fischer reagents are recommended, as these reagents do not contain pyridine, are non-toxic, are very stable, and have no offensive odour. 4.2.3 Neutralization solution, consisting of approximately 4 mg/ml of water in propylene carbonate, ethylene glycol monomethyl ether, 2-methoxyethanol or met

37、hyl cellosolve. 4.2.4 Silica gel, in the form of granules of approximately 2 mm diameter, for use as a desiccant. 4.2.5 SICAPENT1) ) molecular sieve or phosphorus pentoxide, for use as a carrier-gas desiccant. 4.2.6 Grease, containing little or no water and having low water absorptivity, for lubrica

38、ting the ground-glass joints to maintain the airtightness of the system. 4.2.7 Nitrogen gas (N2), containing less than 5 g/g of water. 4.3 Apparatus Ordinary laboratory apparatus and the following: 4.3.1 Coulometric Karl Fischer titrator, consisting of a control unit, a titration-cell assembly (see

39、Figure 1) (equipped with a generator cell, a cathode solution cell, dual platinum sensing electrodes and a magnetic stirrer). The instrument is designed to coulometrically generate iodine that reacts stoichiometrically with the water present in the cell. The coulombs of electricity required to gener

40、ate the reagent are converted to micrograms of water and is given as a direct digital readout. 4.3.2 Water vaporizer, consisting of an oven capable of heating the sample to at least 300 C, a heating tube (see Figure 2), a temperature control unit, a carrier-gas flowmeter and carrier-gas drying tubes

41、 containing desiccant. 1) SICAPENT is a trade name of MERCK. ISOISO 15512:1999(E) 5 4.3.3 Microsyringe, capacity 10 ml, calibrated. 4.3.4 Sample boat: aluminium foil may be used to hand fashion a disposable boat large enough to contain the sample and small enough to fit into the heating tube. 4.4 Pr

42、eparation of sample 4.4.1 The test material may be in any form, such as granules, moulding powder, fabricated shapes or moulded items. 4.4.2 Cut fabricated shapes and moulded items to a suitable size. Granules shall be smaller than 4 mm 4 mm 3 mm. 4.4.3 Take a representative sample of 10 g. Due to t

43、he small size of the sample, care shall be taken to ensure that it is in fact representative. Key 1Coulometric Karl Fischer meter6Water vaporizer10 Flowmeter 2Exhaust gas7Oven11 Temperature controller 3Titration cell8Heating tube12 N2 gas 4Titration controller 5Power supply 9Water-absorption tubes (

44、filled with desiccant, for example P2O5) Figure 1 Flow chart of system used for the determination of water content using method B -,-,- ISO 15512:1999(E) ISO 6 a) Push-bar type b) Magnet type Key 1Sample boat3Sample-boat inlet 2Sample inlet4Magnet Figure 2 Heating tubes 4.5 Procedure 4.5.1 Precautio

45、ns Due to the low quantities of water measured, maximum care shall be exercised at all times to avoid contaminating the sample with water from the sample container, the atmosphere or transfer equipment. Hygroscopic resin samples shall be protected from the atmosphere. 4.5.2 Preparation of apparatus

46、4.5.2.1 Refer to Figure 1 for the following procedure. 4.5.2.2 Assemble the water vaporizer (4.3.2) and coulometric Karl Fischer titrator (4.3.1) as directed in the manufacturers instructions. 4.5.2.3 Fill the absorption tubes with desiccating agent (see 4.3.2) as directed in the manufacturers instr

47、uctions. 4.5.2.4 Pour approximately 200 ml (adjust for the container size) of the anode solution (4.2.1) into the generator cell and 10 ml of the cathode solution (4.2.2) into the cathode solution cell (see 4.3.1). The surface of the cathode solution shall be below the level of the anode solution to

48、 prevent backflow contamination of the cathode solution. 4.5.2.5 Turn the cell power switch on. If the cell potential shows a negative value, indicating that the anode solution contains an excess of iodine, add 50 ml to 200 ml of the neutralization solution (4.2.3). 4.5.2.6 Disconnect the tube connecting the vaporizer unit to the titration cell. Set the carrier-gas flow to (200 to 300) ml/min and heat the oven to the desired temperature to remove any residual water from the vaporizer (4.3.2). 4.5.2.7 Lift the titration cell and agitate the solution by gently swirling the cell t

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1