1、 Reference number ISO 15012-2:2008(E) ISO 2008 INTERNATIONAL STANDARD ISO 15012-2 First edition 2008-04-01 Health and safety in welding and allied processes Requirements, testing and marking of equipment for air filtration Part 2: Determination of the minimum air volume flow rate of captor hoods and

2、 nozzles Hygine et scurit en soudage et techniques connexes Exigences, essais et marquage des quipements de filtration dair Partie 2: Dtermination du dbit volumique minimal dair des bouches de captage Copyright International Organization for Standardization Provided by IHS under license with ISO Lic

3、ensee=Boeing Co/5910770001 Not for Resale, 07/25/2008 04:01:25 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15012-2:2008(E) PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but

4、 shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this a

5、rea. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use

6、 by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2008 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in a

7、ny form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 7

8、49 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2008 All rights reserved Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Boeing Co/5910770001 Not for Resale, 07/25/2008 04:01:25 MDTNo reproduction or networking

9、 permitted without license from IHS -,-,- ISO 15012-2:2008(E) ISO 2008 All rights reserved iii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carri

10、ed out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. I

11、SO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare Internati

12、onal Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the el

13、ements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 15012-2 was prepared by the European Committee for Standardization (CEN) Technical Committee CEN/TC 121, Welding, in collaboration with Technical Committe

14、e ISO/TC 44, Welding and allied processes, Subcommittee SC 9, Health and safety, in accordance with the Agreement on technical cooperation between ISO and CEN (Vienna Agreement). ISO 15012 consists of the following parts, under the general title Health and safety in welding and allied processes Requ

15、irements, testing and marking of equipment for air filtration: Part 1: Testing of the separation efficiency for welding fume Part 2: Determination of the minimum air volume flow rate of captor hoods and nozzles The following part is under preparation: Part 3: Determination of the capture efficiency

16、of welding fume extraction devices using tracer gas Requests for official interpretations of any aspect of this part of ISO 15012 should be directed to the Secretariat of ISO/TC 44/SC 9 via your national standards body. A complete listing of these bodies can be found at www.iso.org. Copyright Intern

17、ational Organization for Standardization Provided by IHS under license with ISO Licensee=Boeing Co/5910770001 Not for Resale, 07/25/2008 04:01:25 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15012-2:2008(E) iv ISO 2008 All rights reserved Introduction Welding and all

18、ied processes generate fume and gases, which, if inhaled, can be harmful to human health. Control is often required to maintain exposure at acceptable levels and this can be achieved by capturing the fume and gases using local exhaust ventilation (LEV), which consists of a capture device, such as a

19、captor hood or nozzle, connected, via ducting, to an exhaust system. The plume of welding fume rises at a velocity of about 0,3 m/s and the air draughts commonly encountered in workshops are of the same order and can be higher. Effective capture of welding fume and gases can only be achieved when th

20、e extracted air velocity at the emission point exceeds the resulting velocity of the draught and the plume, so a velocity of 0,4 m/s has been selected for testing. For a particular capture device, this capture velocity can only be achieved by applying a minimum air volume flow rate, which is depende

21、nt upon the aspect ratio, the cross-sectional area of the device and its distance from the emission point. Consequently, capture devices need to be used with exhaust systems that provide, at least, the minimum air volume flow rate. The design of capture devices can be very different. Aspect ratios r

22、ange from those applicable to circular hoods to those of slots, so the size and shape of the area (capture zone) where fume and gases are captured, while using the minimum air volume flow rate, also varies considerably. Therefore, this part of ISO 15012 requires manufacturers of capture devices to m

23、easure the minimum air volume flow rate at measurement points selected to give an estimate of the size and shape of the capture zone. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Boeing Co/5910770001 Not for Resale, 07/25/2008 04:01:25 MDTN

24、o reproduction or networking permitted without license from IHS -,-,- INTERNATIONAL STANDARD ISO 15012-2:2008(E) ISO 2008 All rights reserved 1 Health and safety in welding and allied processes Requirements, testing and marking of equipment for air filtration Part 2: Determination of the minimum air

25、 volume flow rate of captor hoods and nozzles 1 Scope This part of ISO 15012 specifies a method for establishing the minimum air volume flow rate required for captor hoods and nozzles to effectively capture fume and gases from welding and allied processes. The method can be used with capture devices

26、 of any aspect ratio and cross-sectional area, but it is not applicable to on-gun extraction systems and down draught tables. This part of ISO 15012 also specifies the test data to be marked on the capture devices. 2 Normative references The following referenced documents are indispensable for the a

27、pplication of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 12100-1, Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, metho

28、dology ISO 12100-2, Safety of machinery Basic concepts, general principles for design Part 2: Technical principles Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Boeing Co/5910770001 Not for Resale, 07/25/2008 04:01:25 MDTNo reproduction or n

29、etworking permitted without license from IHS -,-,- ISO 15012-2:2008(E) 2 ISO 2008 All rights reserved 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 12100-1 and ISO 12100-2 and the following apply. 3.1 capture device equipment for capturing welding

30、fume at source See Figure 1. Key 1 entry plane (cross-sectional area for capture devices without flange) 2 nozzle 3 duct 4 nozzle with flange 5 cross-sectional area of a flanged capture device ( W 30) 6 hood 7 hood with flange angle between entry plane and nozzle/hood angle between entry plane and f

31、lange Figure 1 Entry plane and cross-sectional area of different designs of capture device 3.2 capture zone three-dimensional space in front of the entry plane of a capture device in which the air velocity is greater than or equal to the minimum air velocity required for effective capture of welding

32、 fume 3.3 entry plan outermost area of a capture device 3.4 cross-sectional area area of the opening of a capture device in the entry plane (for a nozzle or hood without a flange), or, area of a capture device in the plane in which the flange is attached, excluding the area of any obstructions in th

33、e entry plane (for a nozzle or hood with a flange) See Figure 1. 3.5 aspect ratio ratio of the lengths, x and y, in the entry plane, with x1 W y1 See Figure 2. NOTE The aspect ratio is 1 for a circular device and greater than 1 for other shapes. Copyright International Organization for Standardizati

34、on Provided by IHS under license with ISO Licensee=Boeing Co/5910770001 Not for Resale, 07/25/2008 04:01:25 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15012-2:2008(E) ISO 2008 All rights reserved 3 Key x0, y0, z0 centre point of the entry plane and origin for the m

35、easurement point co-ordinates x1 length of the entry plane of the capture device in the x-direction (x1 W y1) y1 length of the entry plane of the capture device in the y-direction (x1 W y1) Figure 2 Schematic layout for a capture device 3.6 measurement plane plane, parallel to the entry plane, in wh

36、ich measurements of air velocity are made See Figure 1. 3.7 nozzle capture device with an angle, , smaller than 60 between the side of the device and the entry plane See Figure 1. 3.8 flange surface extending outwards from, and almost parallel to ( 30), the entry plane of a capture device, providing

37、 a barrier to unwanted air flow from behind See Figure 1. 3.9 hood capture device with an angle, , greater than or equal to 60 between the side of the device and the entry plane See Figure 1. 3.10 minimum air volume flow rate air volume flow rate required for effective capture of welding fume NOTE T

38、he minimum air volume flow rate depends on the type and the geometric dimensions of the capture device and the test positions selected to demonstrate the extent of the capture zone (see 7.2). Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Boe

39、ing Co/5910770001 Not for Resale, 07/25/2008 04:01:25 MDTNo reproduction or networking permitted without license from IHS -,-,- ISO 15012-2:2008(E) 4 ISO 2008 All rights reserved 4 Principle Tests are performed to determine the air volume flow rate required to achieve an air velocity of 0,4 m/s at a

40、 minimum of two measurements points in front of the capture device on a measurement plane parallel to the entry plane of the capture device. Three tests are performed at each measurement point with air volume flow rates that provide approximate velocities of 0,3 m/s, 0,4 m/s and 0,5 m/s. The air vol

41、ume flow rate that provides a velocity of exactly 0,4 m/s at each measurement point is calculated from linear regression of the results. The minimum air volume flow rate of the capture device is taken to be the highest of the values obtained at the different measurement points. NOTE The minimum air

42、volume flow rate is determined in this manner because it is difficult to set an air volume flow rate that gives an air velocity of exactly 0,4 m/s at a given measurement point. 5 Requirement The manufacturer of a hood or nozzle shall use the results of these tests to specify and mark the device with

43、 the minimum air volume flow rate required to achieve an air velocity of 0,4 m/s in the measurement plane, the distance of the measurement plane from the entry plane and the position of the measurement points selected to demonstrate the extent of the capture zone of the device. The measurement point

44、s shall be identified by their (x, y)-co-ordinates projected from the entry plane. NOTE A hood or nozzle is expected to achieve effective capture of welding fume if it is operated with an air volume flow rate greater than or equal to the determined minimum air volume flow rate and, in addition, if i

45、t is positioned at a distance less than or equal to the distance between the measurement plane and the entry plane of the device. 6 Equipment 6.1 Anemometer, suitable for measuring air velocities in the range 0,3 m/s to 0,5 m/s with a maximum uncertainty of 0,02 m/s, with a response time less than o

46、r equal to 1 s and having a calibration that is traceable to national standards. 6.2 Flow meter, or other suitable device, capable of measuring air volume flow rate with a maximum uncertainty of 5 % and having a calibration that is traceable to national standards. 6.3 Measure, suitable for measuring

47、 distances with an uncertainty of 1 mm. 7 Test method 7.1 Test conditions Position the hood or nozzle so that it is free standing and sited away from any obstructions. Take care to minimise the influence of any disturbing air draughts. 7.2 Position of the measurement plane 7.2.1 Hoods and nozzles wi

48、th an aspect ratio of less than or equal to 4 Determine the required distance, zi, in centimetres, between the measurement plane and the entry plane of the hood or nozzle of the capture device using Equation (1): zi = A + 7,5 (1) where A is the cross-sectional area, in centimetres squared, of the hood or nozzle. Copyright International Organization for Standardization Provided by IHS under license with ISO Licensee=Boeing Co/5910770001 Not for Resale, 07/25/2008 04:01:25 MDTNo reproduc