ISO-647-1974.pdf

上传人:小小飞 文档编号:3778164 上传时间:2019-09-23 格式:PDF 页数:8 大小:472.05KB
返回 下载 相关 举报
ISO-647-1974.pdf_第1页
第1页 / 共8页
ISO-647-1974.pdf_第2页
第2页 / 共8页
ISO-647-1974.pdf_第3页
第3页 / 共8页
ISO-647-1974.pdf_第4页
第4页 / 共8页
ISO-647-1974.pdf_第5页
第5页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《ISO-647-1974.pdf》由会员分享,可在线阅读,更多相关《ISO-647-1974.pdf(8页珍藏版)》请在三一文库上搜索。

1、INTERNATIONAL STANDARD INTERNATIONAL ORGANlZ4TlON FOR STANDARDlZATlON.MEXAYHAPOAHAJl OPI-AHSALViII IT0 CrAHAPTM3A.ORGANlSATlON INTERNATIONALE DE NORMALISATION Brown coals and lignites - Determination of the yields of tar, water, gas and coke residue by low temperature distillation Charbons bruns et

2、lignites - D these documents are now in the process of being transformed into International Standards. As part of this process, Technical Committee ISO/TC 27 has reviewed IS0 Recommendation R 647 and found it technically suitable for transformation. International Standard IS0 647 therefore replaces

3、IS0 Recommendation R 647.1968 to which it is technically identical. IS0 Recommendation R 647 was approved by the Member Bodies of the following countries : Australia Austria Belgium Brazil Canada Chile Czechoslovakia Denmark Egypt, Arab Rep, of France Germany India Ireland Italy Japan Korea, Rep. of

4、 Netherlands New Zealand Poland Portugal Romania South Africa, Rep. of Spain Sweden Switzerland Turkey United Kingdom U.S.S.R. Yugoslavia No Member Body expressed disapproval of the Recommendation. No Member Body disapproved the transformation of ISO/R 647 into an International Standard, 0 Internati

5、onal Organization for Standardization, 1974 l Printed in Switzerland INTERNATIONAL STANDARD IS0 647-1974 (E) Brown coals and lignites - Determination of the yields of tar, water, gas and coke residue by low temperature distillation 0 INTRODUCTION The yield of the distillation products by low tempera

6、ture distillation, especially the yield -of tar, forms the basis for the classification of brown coal and lignite for use in low temperature carbonization. 1 SCOPE AND FIELD OF APPLICATION This International Standard specifies a method for the determination of the yields of tar, water, gas and coke

7、residue obtained from brown coal and lignite by d.istillation to a final temperature of 520 C. 2 REFERENCE ISO/R 1015, Determination of moisture in brown coals and lignites by the direct volumetric method. 3 PRINCIPLE The sample is heated in an aluminium retort to a temperature of 520 C during a per

8、iod of 80 min. The products of decomposition pass into a water-cooled receiver; the tar and water are condensed while gaseous products pass to atmosphere. The coke residue remaining in the retort is weighed. The receiver and its contents are also weighed and the mass of the water in it determined by

9、 entrainment with toluene or xylene : the mass of tar is obtained by difference. The total water in the receiver includes the moisture in the coal as well as that from the decomposition of the coal. A separate determination of moisture in the coal, also by entrainment with toluene or xylene, is made

10、 so that the decomposition water can be calculated. The percentage of gas (plus errors) is obtained by sub- tracting from 100 the sum of the percentages of coke residue, of tar and decomposition water. The results are reported on the “as analysed” and on the “dry” basis. 4 REAGENTS 4.1 Graphite past

11、e, ground dry and made into a suitable paste with water or thick lubricating oil. 4.2 or Xylene, boiling point 135 to 140 C; Toluene, boiling point 110 “C. 5 APPARATUS 5.1 Retort, of aluminium, with the dimensions shown in figure 1; with the cover fitted, its capacity with the outlet tube shall be 1

12、70 + 10 ml; the outlet tube shall be made of brass and its internal wall shall be clean and polished. A new assembly shall be heated at 520 “C for 20 min before use. If, through wear, the upper edge of the conical portion of the cover is below the top surface of the retort, its free volume will be l

13、ess than 160 ml and a new cover is required. The new oversize cover shall be ground so that when fitted the upper edge of the round portion is less than 7 mm above the top surface of the retort. This will ensure that the free volume of the retort does not exceed 180 ml. 5.2 Furnace, heated either el

14、ectrically or by gas. For electrical heating, a resistance wire furnace or a silicon carbide rod furnace may be used. 5.3 Thermocouple and millivoltmeter, or a nitrogen-filled mercury thermometer, calibrated and capable of indicating the temperatures up to 550 “C. NOTE - A new thermometer shall be a

15、ged and then calibrated before use and shall be rechecked at intervals of 1 month by comparing it with a standard thermometer in a manner approved by a national testing authority. 5.4 Receiver : round bottomed glass flask, capacity 750 ml, with conical ground joint and with either long or short neck

16、 depending on the method of connection to the retort (see figure 21, provided with a rubber or glass stopper. 5.5 Cooling bath, such that the distance between the receiver and the walls of the bath is not less than 20 mm. The water flow shall be adjusted to maintain a temperature of between 10 and 1

17、5 “C in the bath. 5.6 Distillation apparatus, suitable for the determination of moisture in brown coal or lignite, as specified in ISO/R 1015. 1 ISO647-1974 (E) 6 PREPARATION OF TEST SAMPLE Spread the laboratory sample on a tray and allow it to attain approximate moisture equilibrium with the atmosp

18、here. Carefully crush the sample so that at least 90 % passes through a sieve of 1 mm aperture whilst not more than 50 % passes through a sieve of 0,2 mm aperture, If the moisture content of the crushed sample is still greater than 20%, further air-drying should be carried out to reduce the moisture

19、 content to between 10 and 20 %. The test sample may be stored in a hermetically sealed container. Alternatively, the sample may be kept for a period not longer than 1 week in a stoppered container filled to more than 80 % of its capacity. NOTE - When samples are kept for longer than 1 week in conta

20、iners which are not hermetically sealed or are not entirely filled, the loss of tar yield can be up to 0,5 % and in certain cases the loss may be considerably greater, 7 PROCEDURE Weigh, to the nearest 0,05 g, about 50 g of the test sample and transfer it completely to the retort. Lightly smear the

21、conical portion of the cover with the graphite paste, replace the cover and seal by rotating it. Determine the moisture content of the test sample at the same time by the method given in ISO/R 1015. Weigh the receiver and stopper to the nearest 0,05 g and connect the receiver to the outlet tube of t

22、he retort by means of either a heat resistant stopper (see figure 2a) or a glass adapter tube (see figure 2bI. In the latter case insert the brass outlet tube about 8 mm into the glass adapter tube and seal it to it by means of a short length of rubber tubing. Wind the joint with cotton, asbestos, l

23、inen, filter paper or similar material and cool by a stream of water while the retort is being heated. Place the retort in the furnace (see note 1) and the receiver in the cooling bath (see note 2) and ensure that the apparatus is gastight. Start the flow of water through the cooling bath and heat t

24、he retort according to the following schedule : Time from start Temperature min OC 10 220 20 310 30 380 40 440 50 480 60 505 70 520 80 520 Maintain the rate of heating within the limits shown in figure 3, At the end of the above period stop the heating and remove the retort from the furnace with the

25、 receiver still connected; allow to stand for 10 min to enable the tar collected in the outlet tube to trickle down into the receiver. Disconnect the receiver from the retort and, if necessary, transfer the remaining tar from the outlet tube into the receiver with a small spatula (see note 3). Close

26、 the receiver and the outlet tube of the retort with stoppers and cool the retort to room temperature. Remove the coke residue carefully and weigh it to the nearest 0,05 g in a previously counterpoised weighing bottle. Wipe off adhering water from the outside of the receiver and re-weigh to obtain t

27、he mass of the tar plus total water. Add 200 ml of toluene or xylene to the receiver and determine the total water content by the method given in ISO/R 1015, NOTES 1 It is necessary to pre-heat certain types of furnaces in order to reach 220C within 10 min of inserting the retort. 2 The receiver sha

28、ll be immersed in the cooling bath as far as possible, but the rubber stopper or the ground joint shall not touch the water, 3 Only a very small residue of tar will be found in a clean smooth brass tube, 8 EXPRESSION OF RESULTS The yields on the “as analysed” basisl) are given by the following formu

29、lae : Coke residue, % m4 x 100 = m0 Tar, % bn2 -ml -m3) x 100 = h Water (decomposition), % m3 xl00 = -M mQ Gas (plus errors), % = 100 - (coke t tar t total water) (m. t rn, -m2 -m4) x 100 =I mo where m. is the mass, in grams, of sample; ml is the mass, in grams, of empty receiver and stopper; m2 is

30、the mass, in grams, of receiver and stopper, plus tar plus total water; 1) Calculation of the results to other bases is dealt with in ISO/R 1170. 2 IS0 647-1974(E) m3 is the mass, in grams, of total water determined by entrainment; m4 is the mass, in grams, of coke residue; M is the moisture content

31、, in percent; of the sample. The yields on the “dry” basis are obtained by multiplying 100 the above results by - 100-M The result, preferably the mean of duplicate determinations (see clause 9), should be reported to the nearest 0,l %. Values for tar, coke residue, decomposition water and gas shoul

32、d be reported on the “as analysed” basis and on the “dry” basis. The tar content may also be calculated on the “dry, ash free” basis. 9 PRECISION OF THE METHOD Test parameter (dry basis) Tar Water Maximum acceptable differences between results Repeatability Reproducibility 0.5 % absolute 0.7 % absol

33、ute 0.4 % absolute 0,8 96 absolute I Coke residue I 0,7 % absolute I I,0 % absolute I 9.1 Repeatability The results of duplicate determinations, carried out at different times in the same laboratory, by the same operator, with the same apparatus, on representative portions taken from the same test s

34、ample, should not differ by more than the above values. 9.2 Reproducibility The means of the results of duplicate determinations, carried out in each of two laboratories on test portions taken from the same laboratory sample, should not differ by more than the above values. 10 TEST REPORT The test r

35、eport shall include the following particulars : a) the reference of the method used; b) the results and the method of expression used; cl any unusual features noted during the determination; d) any operation not included in this International Standard, or regarded as optional. 3 -,-,- IS0 647-1974 (

36、E) Dimensions in millimetres Depth of hole thermometer Screw thread M 12 Bearer bar G ! _-.- 3 for the : 85h ,A /?14*1 Materials : aluminium retort; aluminium content 99 % volume of retort : 170 f 10 ml outlet tube : brass. FIGURE 1 -Retort 4 IS0 647-1974 (E) Dimensions in millimetres Retort with ga

37、s outlet tube - a) I-A Extent of heating furnace W Glass adaoter tube Gas outlet tube Retort with Level of cooling water / Outlet - Heat resistant stopper Heat resistant stopper Level Level of cooling water. of cooling water. Receiver Cooling bath Extent of heating furnace - Receiver Cooling bath l-

38、 XOutlet 4 13,5 FIGURE 2 -Arrangement of the receiver in the cooling bath 5 IS0 647-1974 (El Total time for low temperature distillation between 20 and 520 C : 80 min Effective time for low temperature distillation between 310 and 520 “C : 60 min Temperature “C 500 400 300 200 100 0 Temperature graph against time - Limits 0 20 30 40 50 60 70 80 Time in minutes FIGURE 3 -Schedule of heating -,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 其他


经营许可证编号:宁ICP备18001539号-1