1、J IS JAPANESE I N D USTR IAL STA N DA R D Translated and Published by Japanese Standards Association Air conditioning units for rolling stock ICs 23.120; 45.060.01 Reference number : JIS E 6602 : 2004 (E) PROTECTED BY COPYIEIGHT 9s Copyright Japanese Standards Association Provided by IHS under licen

2、se with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/14/2007 08:16:34 MDTNo reproduction or networking permitted without license from IHS -,-,- E 6602 : 2004 Foreword This translation has been made based on the original Japanese Industrial Standard revised by the Minist

3、er of Land, Infrastructure and Transport and the Minister of Economy, Trade and Industry through deliberations at the Japanese Industrial Standards Committee, as the result of proposal for revision of Japanese Industrial Standard submitted by Japan Association of Rolling Stock Industries (JARI)/Japa

4、nese Standards Association (JSA) with the draft being attached, based on the provision of Article 12 Clause 1 of the Industrial Standardization Law applicable to the case of revision by the provision of Article 14. Consequently JIS E 6602 : 1989 is replaced with this Standard. Attention is drawn to

5、the possibility that some parts of this Standard may conflict with a patent right, application for a patent after opening to the public, utility model right or application for registration of utility model after opening to the public which have technical properties. The relevant Minister and the Jap

6、anese Industrial Standards Committee are not responsible for identifying the patent right, application for a patent after opening to the public, utility model right or application for registration of utility model after opening to the public which have the said technical properties. Date of Establis

7、hment: 1982-02-15 Date of Revision: 2004-04-25 Date of Public Notice in Official Gazette: 2004-04-26 Investigated by: Japanese Industrial Standards Committee Standards Board Technical Committee on Railways and Rolling Stock JIS E 6602 : 2004, First English edition published in 2004-10 Translated and

8、 published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, Tokyo, 107-8440 JAPAN In the event of any doubts arising as to the contents, the original JIS is to be the final authority. O JSA 2004 All rights reserved. No part of this publication may be reproduced or utilized in any form

9、or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. Printed in Japan PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bern

10、ie Not for Resale, 03/14/2007 08:16:34 MDTNo reproduction or networking permitted without license from IHS -,-,- E 6602 : 2004 1 2 3 4 5 6 6.1 6.2 6.3 7 8 9 1 0 11 Contents Page Scope Normative references Definitions Items designated by the purchaser Performance Construction . Construction . Shape a

11、nd dimensions Appearance . Test Inspections Packaging Designation of product . Marking . 1 1 1 1 2 5 5 5 5 5 9 11 11 11 (i PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/14/

12、2007 08:16:34 MDTNo reproduction or networking permitted without license from IHS -,-,- JAPANESE INDUSTRIAL STANDARD JIS E 6602 : 2004 Installing position Air conditioning units for rolling stock a T _ _ J Ej j 1 This Japanese Industrial Standard specifies air conditioning units which are installed

13、in rolling stocks to carry out cooling and/or heating by circulating the air inside the rolling stock (hereafter referred to as ?air conditioner?). Scope 2 Normative references The following standards contain provisions which, through reference in this Standard, constitute provisions of this Standar

14、d. The most recent editions of the standards (including amendments) indicated below shall be applied. JIS C 1502 Sound level meters JIS C 1505 Precision sound level meters JIS E 4001 Railway rolling stock-Vocabulary JIS E 4014 Test methods for insulation resistance and withstand voltage of railway r

15、olling stock JIS E 4031 Railway rolling stock parts-Test methods for vibration JIS Z 8704 Temperature measurement-Electrical methods 3 Definitions 4001 apply. For the purposes of this Standard, the definitions given in JIS E 4 Items designated by the purchaser The purchaser shall designate the fol-

16、lowing items in a deal or an order. The final specification shall be subject to agree- ment between the interested parties. a) The class, type and the like of the rolling The division based on the part to which an air conditioner Classification of rolling stock stock to which an air conditioner is t

17、o be installed. Loading position is to be installed. It shall be as given in table 1. b) Table 1 Classification by the installing position of air conditioner k&ification I On the roof I Underfloor I In floor I On floor I c) The number of loaded conditioners The division of an air conditioner based o

18、n the number of loaded conditioners. It shall be as given in table 2. PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/14/2007 08:16:34 MDTNo reproduction or networking permit

19、ted without license from IHS -,-,- 2 E 6602 : 2004 Classification Centralization system One air conditioner Semi centralization system Dispersed system Two air conditioners Three air conditioners or more d) Structure of an air conditioner The division based on the structure of an air conditioner. It

20、 shall be as given in table 3. Classification Table 3 Division based on the structure of an air conditioner Unit type Separate type That composed of single body as an air conditioner That wherein functional parts are separately arranged and connected by piping I b I Structure Types of air conditione

21、rs The types of air conditioners shall be as follows. 1) 2) 3) Capacity Cooling capacity and/or heating capacity. Air condition specified in 7 a) i), they shall be individually specified. Voltage and frequency The rated voltage, frequency of main circuit and control circuit which become the input po

22、wer source of an air conditioner and their fluc- tuation ranges, and the time and frequency of power discontinuance. Track condition Conditions necessary for designing an air conditioner such as the maximum cant, the maximum gradient, presence of a tunnel and the like. Air conditioner for cooling on

23、ly Cooling and heating air conditioner heat pump Heater heating type cooling heater When there are requests for air conditions other than those 5 Performance The performance of an air conditioner shall be as follows. a) to h) and u) to aa) apply to air conditioners for cooling exclusive use, a) to o

24、) and u) to aa) to heat pump heating type cooling heaters, and a) to h) and o) to aal to heater heating type cooling heaters. a) Cooling capacity rated cooling capacity or higher. Power consumption when cooling When the test of 7 c) is carried out, the result shall be 110 % or less of the rated powe

25、r consumption. When the test in 7 b) is carried out, the result shall be the b) PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/14/2007 08:16:34 MDTNo reproduction or network

26、ing permitted without license from IHS -,-,- 3 E 6602 : 2004 c) Overload performance when cooling When the test of 7 d) is carried out, the protection device of electric current, temperature, pressure and the like shall not operate. Further, the protection device shall be free from abnormality. Over

27、load power consumption when cooling When the test of 7 e) is car- ried out, the power consumption shall not exceed the value agreed between the interested parties. Low temperature performance when cooling When the test of 7 f) is car- ried out, the protection device of electric current, temperature,

28、 pressure and the like shall not operate. Further, the protection device shall be free from ab- normality. Furthermore, there shall be no ice blocks, water droplets or the like falling from the air conditioner into the car. Enclosure sweat When the test of 7 g) is carried out, the protection device

29、for electric current, temperature, pressure and the like shall not operate. Fur- ther? no abnormality shall be found in the protection device. Furthermore, there shall be no dripping or blowing out and the like of dew from the air conditioner into the car. Voltage fluctuation performance when coolin

30、g When the test of 7 h) is car- ried out, the protection device for electric current, temperature, pressure or the like shall not operate. Further, no abnormality shall be found in the protection device. d) e) f) g) h) Winding temperature of motor in cooling When the test of 7 i) is carried out, the

31、 winding temperature of the motor shall be the value in table 4 or lower. Table 4 Upper limit of winding temperature of motor Unit: “C I Classification of insulation I Temperature I Class A Class E Class B Class F 150 I I I I Class H I 170 I (See JIS C 4003 for insulation class) i) Heating capacity

32、shall be at least the rated value. Power consumption when heating When the test in 7 k) is carried out, the heating consumed power shall be at most 110 % of the rated value. Overload performance when heating When the test of 7 1) is carried out, the protection device for electric current, temperatur

33、e? pressure and the like shall not operate. Further, the protection device shall be free from abnormal- ity. When the test of 7 j) is carried out, the heating capacity j) k) PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1

34、111111001, User=Wing, Bernie Not for Resale, 03/14/2007 08:16:34 MDTNo reproduction or networking permitted without license from IHS -,-,- 4 E 6602 : 2004 Overload power consumption when heating When the test of 7 m) is car- ried out, the power consumption shall be at most the value agreed between t

35、he interested parties. Low temperature performance when heating When the test of 7 n) is carried out, the protection device for electric current, temperature, pressure and the like shall not be operated. Further, there shall not be any abnormality in the protection device. Furthermore, the outdoor h

36、eat exchanger shall be free from hazardous enclosure sweat. Voltage fluctuation performance when heating When the test of 7 o) is carried out, the protection device for electric current, temperature, pressure and the like shall not be operated. Further, the protection device shall be free from abnor

37、mality. Winding temperature of motor in heating When the test of 7 p) is carried out, the winding temperature of motor shall be at most the value given in table 4. Rated heating capacity of heater When the test of 7 q) is carried out, the heating capacity of heater shall be at least the rated value.

38、 Heating voltage fluctuation performance of heater When the test of 7 r) is carried out, the protection device for electric current, temperature, pressure and the like shall not be operated. Further, an abnormality shall not be found in the protection device. The temperature of components adjacent t

39、o heat insu- lating material shall not exceed the tolerable value. Heating power consumption of heater When the test of 7 s) is carried out, the power consumption shall not exceed the value agreed between the inter- ested parties. Confirmation of heating temperature of heater When the test of 7 t is

40、 carried out, the temperature of a structure around the heater, heat insulating material and the like shall not exceed the tolerable value. Winding temperature of motor in heating of heater When the test of 7 u) is carried out, the winding temperature of the motor shall not exceed the value in table

41、 4. Resistance to vibration When the test of 7 v) is carried out, abnormalities such as leakage of refrigerant, falling down of screws and the like shall not occur. Insulation resistance When the test of 7 w) is carried out, the insulation resistance shall be 2 MQ or over. Withstand voltage shall wi

42、thstand the test voltage for 1 min. Starting characteristics When the test of 7 y) is carried out, the protection device for electric current, temperature, pressure and the like shall not be op- erated. Further, the protection device shall be free from abnormality. Leakage of refrigerant refrigerant

43、 shall be found at any part of the refrigerant circuit. When the test of 7 x) is carried out, the air conditioner When the test of 7 z) is carried out, no leakage of PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/111111100

44、1, User=Wing, Bernie Not for Resale, 03/14/2007 08:16:34 MDTNo reproduction or networking permitted without license from IHS -,-,- 5 E 6602 : 2004 Dry-bulb temperature z) Waterproof performance When the test of 7 aa) is carried out, no water shall leak into a part corresponding to the inside of a ca

45、r from the air conditioner. aa) Noise When the test of 7 ab) is carried out, the noise shall not exceed the noise value agreed between the interested parties. In that case, it shall be confirmed that there is no abnormal sound such as roars, resonance and the like. The measuring point should prefera

46、bly be determined by the consultation between the interested parties. Wet-bulb Dry-bulb Wet-bulb temperature temperature temperature 6 Construction Cooling 6.1 pressor, blower, heat exchanger and the like. Construction The construction of an air conditioner consists of a body, com- Standard conditio

47、n 28 k 1.0 23 f 1.0 33 k 1.5 - Overload condition 35 i 1.0 28 * 1.0 45 i 1.5 - Low temperature 20 2 c 1.0 14+1.0 20 * 1.0 - condition 6.2 be subjected to agreement between the interested parties. Shape and dimensions The shape and dimensions of an air conditioner shall Heating 6 . 3 from such defect

48、s as scratches detrimental to service. Appearance Every part of an air conditioner shall be finished well and free Enclosure sweat 28 i 1.0 25 i 1.0 28 f 1.0 - condition Standard condition 21 k 1.0 - 7 i 1.5 6 i 1.5 7 Test Tests of b) to i) and v) to ab) for an air conditioner of exclusive cooling use, b) to p) and v) to ab) for heat pump heating type cooling heater and b) to i) and q) to ab) for heater heating type cooling heater, respectively, shall be carried out. a) Test conditions The test conditions for an air conditioner shall be as follows: i) Air conditions shall be as gi