JIS-C-7525-2003-ENG.pdf

上传人:西安人 文档编号:3783727 上传时间:2019-09-23 格式:PDF 页数:24 大小:739.03KB
返回 下载 相关 举报
JIS-C-7525-2003-ENG.pdf_第1页
第1页 / 共24页
JIS-C-7525-2003-ENG.pdf_第2页
第2页 / 共24页
JIS-C-7525-2003-ENG.pdf_第3页
第3页 / 共24页
JIS-C-7525-2003-ENG.pdf_第4页
第4页 / 共24页
JIS-C-7525-2003-ENG.pdf_第5页
第5页 / 共24页
亲,该文档总共24页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《JIS-C-7525-2003-ENG.pdf》由会员分享,可在线阅读,更多相关《JIS-C-7525-2003-ENG.pdf(24页珍藏版)》请在三一文库上搜索。

1、J IS JAPANESE I NDUSTRIAL STANDARD Translated and Published by Japanese Standards Association (JELMA/ JSA) Reflector incandescent lamps ICs 29.140.20 Reference number : JIS C 7525 : 2003 (E) PROTECTED EIY COPYRIGHT 13 S Copyright Japanese Standards Association Provided by IHS under license with JSAL

2、icensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 20:56:23 MDTNo reproduction or networking permitted without license from IHS -,-,- C 7525 : 2003 Foreword This translation has been made based on the original Japanese Industrial Standard revised by the Minister of Econom

3、y, Trade and Industry through deliberations at the Japanese Industrial Standards Committee, as the result of proposal for revision of Japanese Industrial Standard submitted by the Japan Electric Lamp Manufacturers Association (JELMA)/the Japanese Standards Association (JSA) with the draft being atta

4、ched, based on the provision of Article 12 Clause 1 of the Industrial Standardization Law applicable to the case of revision by the provision of Article 14. Consequently JI$ C 7525 : 1992 is replaced with this Standard. JIS C 7525 : 1992 specified the performances of these lamps together with their

5、safety, but such a revision has been made at this time, in order to make conformity of Japanese Industrial Standard and International Standard (IEC) in their systems, that this Standard specifies only the performance requirements and dimensions, and JIS C 7551-1 : 1999 shall be referred for the safe

6、ty requirements. Attention is drawn to the possibility that some parts of this Standard may conflict with a patent right, application for a patent after opening to the public, utility model right or application for registration of utility model after opening to the public which have technical proper

7、ties, The relevant Minister and the Japanese Industrial Standards Committee are not responsible for identifying the patent right, application for a patent after opening to the public, utility model right or application for registration of utility model after opening to the public which have the said

8、 technical properties. Date of Establishment: 1964-03-01 Date of Revision: 2003-03-20 Date of Public Notice in Official Gazette: 2003-03-20 Investigated by: Japanese Industrial Standards Committee Standards Board Technical Committee on Electricity technology JIS C 7525 : 2003, First English edition

9、published in 2003-09 Translated and published by: Japanese Standards Association 4-1-24, Akasaka, Minato-ku, Tokyo, 107-8440 JAPAN In the event of any doubts arising as to the contents, the original JIS is to be the final authority. O JSA 2003 All rights reserved. Unless otherwise specified, no part

10、 of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. Printed in Japan PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under lic

11、ense with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 20:56:23 MDTNo reproduction or networking permitted without license from IHS -,-,- C 7525 : 2003 Contents Page 1 1 1 2 2 3 3 3 3 4 4 4 4 4 6 6 6 7 9 Section 1 General 1.1 Scope 1.2 Normative references 1.3 D

12、efinitions . 1.4 Classification Section 2 Data sheet of lamp 2.1 Type designation and data sheet number of lamp Section 3 3.1 Performances 3.2 Dimensions 3.3 Safety . Performances, dimensions and safety Section 4 Acceptance criteria 4.1 Tests . 4.2 Inspections Section 5 Designation of product and ma

13、rking . 5.1 Designation of product 5.2 Marking . Annex 1 (normative) Test methods . Annex 2 (normative) Maximum outline dimensions of lamps . (i) PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie

14、 Not for Resale, 03/15/2007 20:56:23 MDTNo reproduction or networking permitted without license from IHS -,-,- JAPANESE INDUSTRIAL STANDARD JIS C 7525 : 2003 Reflector incandescent lamps Section 1 General 1.1 Scope This Japanese Industrial Standard specifies reflector incandescent lamps which comply

15、 with the safety requirements for general lighting incandescent lamps specified in Section 2 Safety requirements of JIS C 7551-1 and also satisfy the fol- lowing conditions: Rated power consumption 40 W or over up to and including 200 W Rated voltage 100 v Shape of glass bulb Type R Remarks : The sh

16、ape and name of glass bulb are in accordance with JIS C 7710. Cap E26/25 Remarks : The type and dimensions of cap are in accordance with JIS C 7709-1. 1.2 Normative references The following standards contain provisions which, through reference in this Standard, constitute provisions of this Standard

17、. If the indication of the year of coming into effect is given to these referred standards, only the edition of indicated year constitutes the provision of this Standard but the revi- sion and amendment made thereafter are not applied. The normative references without the indication of the year of c

18、oming into effect (or the year of publication) apply lim- iting only to the most recent edition (including amendments). JIS B 7507 JIS C 7551-1 Safety specifications for incandescent lamps-Part 1 : Tungsten fila- ment lamps for domestic and similar general lighting purposes Remarks : IEC 60432-1 : 1

19、993 Safety specifications for incandescent lamps- Part 1 : Tungsten filament lamps for domestic and similar general lighting purposes and Amendment 1 : 1995 are equivalent to the said standard. JIS C 7709-1 Lamp caps and holders together with gauges for the control of in- terchangeability and safety

20、-Part 1 : Lamp caps Remarks : IEC 60061-1 Lamp caps and holders together with gauges for the control of interchangeability and safety-Part I : Caps is equivalent to the said standard. JIS C 7709-3 Lamp caps and holders together with gauges for the control of in- terchangeability and safety-Part 3 :

21、Gauges Remarks : IEC 60061-3 Lamp caps and holders together with gauges for the control of interchangeability and safety-Part 3 : Gauges is equiva- lent to the said standard. Vernier, dial and digital callipers JIS C 7710 Designation method for glass bulbs of lamps PROTECTED BY COPYRIGHT Copyright J

22、apanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 20:56:23 MDTNo reproduction or networking permitted without license from IHS -,-,- 2 C 7525 : 2003 Remarks : IEC/TR 60887 : 1988 Glass bulb designation

23、system for lamps is equivalent to the said standard. JIS C 7801 General rules of testing method for lamps JIS C 8302 Edison screw lampholders JIS Z 8113 Lighting vocabulary IEC 60061-3 Lamp caps and holders together with gauges for the control of in- terchangeability and safety-Part 3 : Gauges IEC 6

24、1126 : 1992 Procedure for use in the preparation of maximum lamp outlines 1.3 stated in JIS Z 8113, the following principal definitions apply: Definitions For the purposes of this Standard, in addition to the definitions rated voltage rated wattage initial luminous flux The total luminous flux at th

25、e rated voltage after age- ing. rated initial luminous flux reference for service. maximum luminous intensity The maximum luminous intensity in the light distribution of a lamp. beam spread The angle made by two directions where the relative value of luminous intensity on the polar coordinate on the

26、 plain specified for the lumi- nous intensity distribution characteristic of a lamp, takes 50 % of the maximum luminous intensity. beam flux The luminous flux existing within the beam spread with the light centre of the luminous intensity distribution of a lamp being the apex. lumen maintenance The

27、percentage ratio of the total luminous flux after op- eration of the specified hours to the initial luminous flux. life The operating hours until the filament breaks. rated life of the same type lamps manufactured for a long period of time. Classification Classification is made by the type designati

28、on as stated in 2.1. The voltage marked on a lamp. The power consumption marked on a lamp. The initial luminous flux which is used as the The hours officially announced based on the mean value of the lives The type designation is formed in the order shown below. PROTECTED BY COPYRIGHT Copyright Japa

29、nese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 20:56:23 MDTNo reproduction or networking permitted without license from IHS -,-,- 3 C 7525 : 2003 Type designation RF 1 OOV40W RF 1 OOV60W RF 1 oov1 oow R

30、FlOOV150W RF 100v200w W 1 OOV90WH RF100V135WH RFI oov 1 sow 1 Symbol denoting reflector incandescent lamp I Data sheet number C7525-JIS-25OOJ-1 C7525-JIS-25 1 OJ-1 C7525-JIS-252OJ- 1 C7525-JIS-25303- 1 C7525-JIS-254OJ- 1 C7525-JIS-255OJ-1 C7525-JIS-2560E 1 C7525-JIS-257OJ-1 2 Symbol denoting beam sp

31、read rated voltage rated wattage 5 Symbol denoting material of glass bulb beam spread of 35“ or more (mainly for indoor H: lamps of hard 135 W 150 W 180 W glass (mainly for 200 w outdoor use) Remarks : Symbols and numerals denoting further identification may be added to the end of this type designat

32、ion. Section 2 Data sheet of lamp 2.1 Type designation and data sheet number of lamp The type designation of lamp and the data sheet number by which the lamp is specified shall be as stated in Table 1. Section 3 Performances, dimensions and safety 3.1 a b) Performances The performances shall be as f

33、ollows: Initial characteristics When the tests are carried out in accordance with An- nex 1 (normative), the initial characteristics shall be such that the maximum luminous intensity and the beam flux shall be not less than 80 % of those speci- fied in the data sheet. However, they shall be not less

34、 than 75 % for white coated lamps. The wattage shall not exceed 104 % of the rated wattage specified in the data sheet plus 0.5 W. Life When the test is carried out in accordance with Annex 1 (normative), the life shall be such that the individual value is not less than 70 % of, and the mean value i

35、s not less than 96 % of the rated life specified in the data sheet. PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 20:56:23 MDTNo reproduction or networking permitte

36、d without license from IHS -,-,- 4 C 7525 : 2003 c) Lumen maintenance The total luminous flux is measured after burning for 75 % of the rated life and the ratio to initial luminous flux is obtained, the lumen main- tenance so obtained shall be not less than the value specified in the data sheet. 3 .

37、 2 sheet. Dimensions The dimensions shall be as stated in Fig. 1 and the relevant data 3 . 3 Safety The safety shall be as stated in Section 2 of JIS C 7551-1. The test of 2 . 3 in JIS C 7551-1, may be carried out by using either the gauge specified in IEC 60061-3 or the lampholder specified in JIS

38、C 8302. Section 4 Acceptance criteria 4 . 1 mative). Tests The test conditions and test methods shall be as stated in Annex 1 (nor- 4 . 2 Inspections 4 . 2 . 1 Type inspection The type inspection shall be carried out on the same speci- men in accordance with the methods stated in 4 . 1 for the follo

39、wing items: a) Dimensions b) Initial characteristics c) Life d) Lumen maintenance 4 . 2 . 2 Lot inspection a) Inspection items The lot inspection shall be carried out in accordance with the methods stated in 4 . 1 for the following items: 1) Dimensions 2) Initial characteristics 3) Life 4) Lumen mai

40、ntenance Sampling inspection The sampling inspection shall be made according to either of the plans given below: 1) Sampling inspection A The sample size, acceptance number and qual- ity criterion shall be as stated in Table 2. b) PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provi

41、ded by IHS under license with JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 20:56:23 MDTNo reproduction or networking permitted without license from IHS -,-,- 5 C 7525 : 2003 Inspection item number Table 2 Sample size and acceptance number I I l I Quality criteri

42、on Wattage Maximum luminous intensity Beam flux Initial character- istics 1 Dimension O I As given in 3.2. Life (mean value) Life (individual value) Lumen maintenance 20 - 3 (12) (1) 2 I As given in 3.1 a). Initial character- istics As given in 3.1 a). 1 Wattage 100 Maximum luminous 10 intensity Bea

43、m flux I As given in 3.1 a). Life (mean value) Life (individual value) Lumen maintenance 50 As given in 3.1 b). A s given in 3.1 b). As given in 3.1 c ) . Remarks 1 A part of lamps for dimensional test may be used for initial characteristic tests. 2 The life inspection shall be carried out on the la

44、mps sampled at random from the lamps accepted in the initial character- istic tests. The sample size shall be 20 as the standard, but n = 12 may be taken if it is difficult to prepare the said size due to unavoidable reason. 2) Sampling inspection B The sample size and acceptance number shall be as

45、stated in Table 3. Table 3 Sample size and acceptance number Inspection item Sample size Acceptance number 1 (n) I (c) Quality criterion 1 Dimension I 50 I 4 I As given in 3.2. I I I As given in 3.1 a). I 12 2 As given in 3.1 a). As given in 3.1 a). As given in 3.1 b). 8 Remarks 1 A part of lamps fo

46、r dimensional test may be used for initial characteristic tests. 2 The life inspection shall be carried out on the lamps sampled at random from the lamps accepted in the initial character- istic tests. PROTECTED BY COPYRIGHT Copyright Japanese Standards Association Provided by IHS under license with

47、 JSALicensee=IHS Employees/1111111001, User=Wing, Bernie Not for Resale, 03/15/2007 20:56:23 MDTNo reproduction or networking permitted without license from IHS -,-,- 6 C 7525 : 2003 Section 5 Designation of product and marking 5 . 1 type (designation). Designation of product A product shall be desi

48、gnated by the name and the Example : Reflector incandescent lamp RF100V100W 5.2 Marking 5.2.1 Marking on product The following items shall be marked on the conspicuous part of glass bulb or cap of each lamp: a) Type designation (items other than rated voltage and rated wattage may be omitted) b) Manufacturers name or abbreviation 5.2.2 Marking on package The following items shall be marked on each pack- aging container: a) Type designation b) Manufacturers name or abbreviation c) Identification of indoor service or