UL-17-1994.pdf

上传人:哈尼dd 文档编号:3801740 上传时间:2019-09-23 格式:PDF 页数:66 大小:3.92MB
返回 下载 相关 举报
UL-17-1994.pdf_第1页
第1页 / 共66页
UL-17-1994.pdf_第2页
第2页 / 共66页
UL-17-1994.pdf_第3页
第3页 / 共66页
UL-17-1994.pdf_第4页
第4页 / 共66页
UL-17-1994.pdf_第5页
第5页 / 共66页
亲,该文档总共66页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《UL-17-1994.pdf》由会员分享,可在线阅读,更多相关《UL-17-1994.pdf(66页珍藏版)》请在三一文库上搜索。

1、 Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 08:29:00 MDTNo reproduction or networking permitted without license from IHS -,-,- Underwriters Laboratories 1nc.s Northbrook, Illinois * (847) 272-880

2、0 Melville, New York. (516) 271-6200 Santa Clara, California (408) 985-24GO Research Triangle Park, North Carolina * (919) 549-1400 Camas, Washington. (360) 817-5500 Underwriters Laboratories Inc., founded in 1894, is chartered as a not-for-profit organization without capital stock, under the laws o

3、f the State of Delaware, to establish, maintain, and operate laboratories for the examination and testing of devices, systems and materials to determine their relation to hazards to life and property, and to ascertain, define and publish standards, classifications and specifications for materials, d

4、evices, products, equipment, constructions, methods, and systems affecting such hazards. UL Standards for Safety are developed under a procedure which provides for participation and comment from the affected public as well as industry. The procedure takes into consideration a survey of known existin

5、g standards and the needs and opinions of a wide variety of interests concerned with the subject matter of the standard. Thus manufacturers, consumers, individuals associated with consumer-oriented organizations, academicians, government officials, industrial and commercial users, inspection authori

6、ties, insurance interests and others provide input to UL in the formulating of UL Standards for Safety, to keep them consonant with social and technological advances. A not for profit organization dedicated to public safety and committed to quality service Copyright Underwriters Laboratories Inc. Pr

7、ovided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 08:29:00 MDTNo reproduction or networking permitted without license from IHS -,-,- SEPTEMBER 3.1999 - UL 17 t i l Underwriters Laboratories Inc. (UL) 333 Pfingsten Road Northbrook, IL 60062-2096

8、UL Standard for Safety for Vent or Chimney Connector Dampers for Oil-Fired Appliances, UL 17 Third Edition, Dated May 12, 1994 Revisions: This Standard contains revisions through and including September 3, 1999. UL is in the process of converting its Standards for Safety to the Standard Generalized

9、Markup Language (SGML), and implementing an SGML compliant document management and publishing system. SGML - an international standard (IS0 8879-1 986) - is a descriptive markup language that describes a documents structure and purpose, rather than its physical appearance on a page. Significant bene

10、fits that will result from ULs use of SGML and these new systems include increased productivity, reduced turnaround times, and data and information consistency, reusability, shareability, and portability. However, the fonts, pagination, and general formatting of ULs new electronic publishing system

11、differ from that of ULs previous publishing system. Consequently, when revision pages are issued for a Standard with the new publishing system, these differences may result in the printing of pages on which no requirements have been changed - these additional pages result from relocation of text due

12、 to repagination and reformatting of the Standard with the new publishing system. Text that has been changed in any manner is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the dat

13、e of publication or the date on which the changed requirement becomes effective. The revisions dated September 3, 1999 include a reprinted title page (pagel) for this Standard. The revisions dated September 3, 1999 were issued for editorial corrections. These corrections include any combination of t

14、he following: Updated Foreword (item D); Updated Scope; title changes to UL 489 and/or UL 1950; Removal of the “94“ flammability classification. These revisions may also include other miscellaneous editorial corrections. The revisions dated September 8, 1998 include changing references to UL 519, St

15、andard for lmpedance-Protected Motors, and UL 547, Standard for Thermal Protection for Motors, to UL 2111, Standard for Overheating Protection for Motors. UL 519 and UL 547 have been withdrawn and replaced by UL2111. As indicated on the title page (page l), this UL Standard for Safety is an American

16、 National Standard. Attention is directed to the note on the title page of this Standard outlining the procedures to be followed to retain the approved text of this ANSI/UL Standard. The master for this Standard at ULs Northbrook Office is the official document insofar as it relates to a UL service

17、and the compliance of a product with respect to the requirements for that product and service, or if there are questions regarding the accuracy of this Standard. ULs Standards for Safety are copyrighted by UL. Neither a printed copy of a Standard, nor the distribution diskette for a Standard-on-Disk

18、ette and the file for the Standard on the distribution diskette should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. Copyright Underwriters Laboratories Inc. Provided by IHS under l

19、icense with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 08:29:00 MDTNo reproduction or networking permitted without license from IHS -,-,- STD-UL 17-ENGL 1994 9275775 079b735 707 = tR SEPTEMBER 3.1999 - UL 17 All rights reserved. No pari of this publication may be reprodu

20、ced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. Revisions of UL Standards for Safety are issued from time to time. A UL Standard for Safety is current only if it incorporates the

21、most recently adopted revisions. UL provides this Standard “as is“ without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or fitness for any purpose. In no event will UL be liable for any special, incidental, consequential,

22、indirect or similar damages, including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability

23、for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. UL will attempt to answer support requests concerning Wordperfect, Envoy, and Standards-on-Diskette. However, this support service is offered on a reasonable efforts basis only, and UL may not be able t

24、o resolve every support request. UL supports a Standards-on-Diskette only if it is used under the conditions and operating systems for which it is intended. U r s support policies may change from time-to-time without notif ication. UL reserves the right to change the format, presentation, file types

25、 and formats, delivery methods and formats, and the like of both its printed and electronic Standards without prior notice. Standards-on-Diskette purchasers agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgement (including reasonab

26、le attorneys fees) resulting from any error or deviation introduced while purchaser is storing a Standard-on-Diskette on the purchasers computer system. If a single-user version Standards-on-Diskette was purchased, one copy of this Standard may be stored on the hard disk of a single personal compute

27、r, or on a single LAN file-server or the permanent storage device of a multiple-user computer in such a manner that this Standard may only be accessed by one user at a time and for which there is no possibility of multiple concurrent access. The original distribution diskette should be stored in a s

28、afe place. If a multiple-user version Standards-on-Diskette was purchased, one copy of the Standard may be stored on a single LAN file-server, or on the permanent storage device of a multiple-user computer. The number of concurrent users shall not exceed the number of users authorized for the Standa

29、rds-on-Diskette version. The original distribution diskette should be stored in a safe place. Standards-on-Diskette are intended for on-line use, such as for viewing the requirements of a Standard, conducting a word search, and the like. Only one copy of the Standard may be printed from each single-

30、user version of a Standards-on-Diskette. Only one copy of the Standard may be printed for each authorized user of a multiple-user version of a Standards-on-Diskette. An employee of an organization purchasing a Standard-on-Diskette can make a copy of the page or pages being viewed for their own fair

31、and/or practical internal use. Because of differences in the computer/software/printer setup used by UL and those of Standards-on-Diskette purchasers, the printed copy obtained by a purchaser may not look exactly like the on-line screen view or the printed Standard. Copyright Underwriters Laboratori

32、es Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 08:29:00 MDTNo reproduction or networking permitted without license from IHS -,-,- SEPTEMBER 3.1999 - UL 17 tr3 The requirements in this Standard are now in effect, except for those par

33、agraphs, sections, tables, figures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded

34、by a “SUPERSEDED REQUIREMENTS notice. New product submittals made prior to a specified future effective date will be judged under all of the requirements in this Standard including those requirements with a specified future effective date, unless the applicant specifically requests that the product

35、be judged under the current requirements. However, if the applicant elects this option, it should be noted that compliance with all the requirements in this Standard will be required as a condition of continued Listing, Recognition, and Follow-Up Services after the effective date, and understanding

36、of this should be signified in writing. Copyright O 1999 Underwriters Laboratories Inc. This Standard consists of pages dated as shown in the following checklist: Page Date 1 . September 3, 1999 2 . September 8, 1998 2A-5. . September 3, 1999 6-12 . May 12, 1994 13-1 48 . September 8, 1998 15-20 May

37、 12, 1994 21-24 . September8, 1998 25-32. . May 12, 1994 33-34 . September 3, 1999 35-43. . May 12, 1994 44-45 December 12, 1995 46 May 12, 1994 47 . ApriI7, 1995 48-50. . May 12, 1994 Al -A2 September 8, 1998 Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Arm

38、y Northwestern Div./7838506130 Not for Resale, 08/29/2006 08:29:00 MDTNo reproduction or networking permitted without license from IHS -,-,- STD*UL 17-ENGL 1994 9275775 077b737 581 E SEPTEMBER 3,1999 - UL 17 tr4 No Text on This Page Copyright Underwriters Laboratories Inc. Provided by IHS under lice

39、nse with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 08:29:00 MDTNo reproduction or networking permitted without license from IHS -,-,- STD-UL 27-ENGL L77Li 7275795 077b738 928 MAY 12,1994 (Title Page Reprinted: September 3, 1999) , I ANSUUL 17-1995 I 1 UL 17 Standard for

40、 Vent or Chimney Connector Dampers for Oil-Fired Appliances First Edition - July, 1982 Second Edition - November, 1988 Third Edition May 12,1994 Approval as an American National Standard (ANSI) covers the numbered paragraphs on pages dated May 12, 1994, April 7, 1995, September 8,1998, and September

41、 3, 1999 . These pages should not be discarded when revised or additional pages are issued if it is desired to retain the ANSI approved text. An effective date included as a note immediately following certain requirements is one established by Underwriters Laboratories Inc. Approved as ANSI/UL 17-19

42、95, February 13, 1995 Revisions of this Standard will be made by issuing revised or additional pages bearing their date of issue. A UL Standard is current only if it incorporates the most recently adopted revisions, all of which are itemized on the transmittal notice that accompanies the latest set

43、of revised requirements. ISBN 1-55989-586-1 COPYRIGHT Q 1982,1999 UNDERWRITERS LABORATORIES INC. I Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 08:29:00 MDTNo reproduction or networking permitted w

44、ithout license from IHS -,-,- STD-UL L7-ENGL L77l W 7275775 079b737 354 2 VENT OR CHIMNEY CONNECTOR DAMPERS FOR OIL-FIRED APPLIANCES - UL 17 SEPTEMBER 8.1998 No Text on This Page Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130

45、Not for Resale, 08/29/2006 08:29:00 MDTNo reproduction or networking permitted without license from IHS -,-,- STD*UL 17-ENGL 1994 7275775 079b79O 076 M SEPTEMBER 3. 1999 VENT OR CHIMNEY CONNECTOR DAMPERS FOR OIL-FIRED APPLIANCES . UL 17 2A CONTENTS FOREWORD 4 INTRODUCTION 1 Scope . 5 2 Glossary . 5

46、3 Components 6 4 Units of Measurement . 6 CONSTRUCTION 5 Assembly 7 5.1 General . 7 5.2 Electrical circuits . 8 6 Materials . 8 7 Springs 8 8 Enclosure 9 8.1 General . 9 8.2 Doors and covers . 9 8.3 Openings . 12 9 Supply Connections 15 9.1 General 15 9.2 Lead wires 16 9.3 Terminals . 16 9.4 Wiring

47、space 17 1 O Current-Carrying Parts 17 11 Mounting of Electrical Components . 17 12 Internal Wiring 18 13 Separation of Circuits . 19 14 Bonding for Grounding 19 15 Motors and Motor Overload Protection 21 16 Insulating Material 24 17 Spacings 24 17.1 General . 24 17.2 High-voltage circuits 24 17.3 L

48、ow-voltage circuits . 26 PERFORMANCE 18 General 27 19 Input 28 20 Heating Test . 28 20.1 Test installation 28 20.2 Temperature measurements on other than electrical parts . 30 20.3 Temperature measurement on electrical components. thermocouple method 33 20.4 Test method . 34 20.5 Assembly intended for installation in flue pipe system . 34 20.6 Remote control assembly . 34 21 Special Heating Test 38 22 Increased and Undervoltage Tests 39 Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Nor