1、Subjects 294 (205, 205A, 365, 603, 606, 609, 634, 636, 639, 681, 827, 864, 985, 1023, 1037, 1076, 1610, 1635, 1637, 1641) (in reply, refer to Subject 294) TO: 1655 Scott Blvd. Santa Clara, CA 95050 July 30, 2004 Standards Technical Panel (STP) for Burglary Protection Systems and Services, STP Standa

2、rds Technical Panel (STP) for Burglary Protection Equipment, STP 205A; Subscribers to ULs Standards Service for 205; Access Control System Units; Police Station Connected Burglar Alarm Units and Systems; Power Supplies for Use with Burglar-Alarm Systems; Linings and Screens for Use with Burglar-Alar

3、m Systems; Local Burglar Alarm Units and Systems; Connectors and Switches for Use with Burglar-Alarm Systems; Holdup Alarm Units and Systems; Intrusion-Detection Units; Installation and Classification of Burglar and Holdup Alarm Systems; Central-Station Alarm Services; Control Units and Accessories

4、for Fire Alarm Systems; Household Fire Warning System Units; Household Burglar-Alarm System Units; Antitheft Alarms and Devices; Proprietary Burglar Alarm Units and Systems; Central-Station Burglar-Alarm Units; Digital Alarm Communicator System Units; Home Health Care Signaling Equipment; Installati

5、on and Classification of Residential Burglar Alarm Systems; Other Interested Parties SUBJECT: Report of the Meeting of the Standards Technical Panels of UL for Burglary Protection Equipment and Burglary Protection Systems and Services; Summary of Topics The following topics were discussed at the mee

6、ting: 1. Comments received regarding the proposal bulletin dated September 29, 2003 2. Comments received regarding the ANSI ballot for UL 1641 dated October IO, 2003 3. Comments received regarding the ANSI ballot for UL 1037 dated March 19, 2004 4. Proposed revision to the Standard for Connectors an

7、d Switches for Use with Burglar- Alarm Systems, UL 634 5. ANSI Recognition update 6. Mechanical Strength Test for Metal Enclosures and Guards Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 22:20:10 M

8、DTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 294 -2- JULY 30,2004 7. Dielectric Voltage Withstand Test 8. Transient Test 9. Jarring Test IO. Fail Safe Egress I I . Remote Station Service 12. Request for Working Groups for UL 294 13. Manual backup at subsidiary loc

9、ations 14. Harmonization with IEC standards 15. False Alarms 16. Enhanced Call Verification 17. Voice Over Internet Protocol (VolP) 18. EMC/EM1 requirements 19. Proposed changes to the Standard for .:cess Con o 20. Signaling across the internet 21. Makeup of STP 205 and STP 205A System Units, UL 294

10、 22. Consistency of standards covered under STP 205 and STP 205A COMMENTS DUE: September 3,2004 A meeting of the Standards Technical Panels of UL for Burglary Protection Systems and Services, STP 205 and Burglary Protection Equipment, STP 205A was held on June 22 and 23, 2004 at the Hilton Northbroo

11、k. The purpose of the meeting was to discuss comments received on the Subject 1610 bulletin dated September 29, 2003, the STP 205 bulletin dated October IO, 2003 and the STP 205A bulletin dated March 19, 2004. The meeting was also held to discuss several proposals that were received. Comments should

12、 be made in writing and may be sent by fax to (408) 556-6045 or by mail to the attention of Jeline Gonzaga at ULs Santa Clara office, 1655 Scott Blvd., Santa Clara, CA 95050. Comments may also be sent via E-mail to Jeline.G. Please reference all correspondence to Subject 294. Note all comments recei

13、ved are public and may be circulated to others. If you respond by fax or E-mail, please include your full name and company name and address to ensure a reply. Attached as Appendices A, B, and C for your review and comment are the comment matrices for the proposal bulletins dated September 29, 2003,

14、October IO, 2003 and March 19, 2004, respectively. Attached as Appendices D - G for your review and comment are proposed requirements for UL 365, UL 1076, UL 1610 and UL 1641 as referenced in the comment matrices. Attached as Appendix H Copyright Underwriters Laboratories Inc. Provided by IHS under

15、license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 22:20:10 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 294 -3- JULY 30,2004 Standard UL 365 UL 609 UL 1023 UL 1076 UL 1610 UL 1635 UL 1641 is information regarding Working Groups.

16、 Attached as Appendix I is a list of those who attended the meeting. Questions regarding interpretation of requirements should be directed to the responsible UL Staff. Yes No Abstain 29 3 O 28 2 O 16 O O 27 3 O 16 1 O 17 1 O 17 1 O The attached comment matrices provide the proposed comment dispositi

17、ons from the ballot of the proposal bulletins dated September 29, 2003, October IO, 2003 and March 19, 2004. The ballots were due to the Project Manager by November 28, 2003, December 9, 2003 and May 18, 2004 respectively. The matrices contain all of the comments that were received. The effective da

18、tes are the same as stated in the proposal bulletins dated September 29, 2003, October IO, 2003 and March 19, 2004 unless noted otherwise. UL has determined that consensus has been achieved regarding the ANSI approval of the proposed revisions to UL 365, UL 609, UL 1023, UL 1076, UL 1610, UL 1635 an

19、d UL 1641. The initial consensus count is as follows: If you wish to change your vote in light of the dispositions/actions or the proposed changes, please respond to us in writing by September 3, 2004. If we do not hear from you by this date, your original vote will be maintained. If the STP concurs

20、 with the dispositions/actions, UL plans to adopt the revised versions of UL 365, UL 609, UL 1023, UL 1076, UL 1610, UL 1635 and UL 1641 as ANSI standards. Once UL has determined that consensus has been achieved regarding the ANSI approval of UL 1037 and the STP concurs with the actions/dispositions

21、, UL plans to adopt the revised version of UL 1037 as an ANSI standard. The initial consensus count is 10 yes, 1 no, and O abstain. If you wish to change your vote in light of the dispositions/actions or the proposed changes, please respond to us in writing by September 3, 2004. If we do not hear fr

22、om you by this date, your original vote will be maintained. Anyone who has submitted an objection has the right to appeal this action on a procedural basis through UL?s Appeals Process. If you wish to appeal, please respond by September 3,2004. Please note only appeals based on a procedural issue wi

23、ll be heard, technical issues should be resolved at the consensus body level. Guidelines on how to register an appeal can be obtained on http:/ ulstandardsinfonet.uI.com or by contacting the STP Project Manager. Please note that proposed requirements are of a tentative and early nature and are for r

24、eview and comment only. Current requirements are to be used to judge a product until these requirements are published in final form. * * * * * * The following report is not intended to be a verbatim transcript of the discussion at the meeting, but is intended to record the significant features of th

25、ose discussions. Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 22:20:10 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 294 -4- JULY 30,2004 CALL TO ORDER, ANNOUNCE

26、MENTS, INTRODUCTION OF MEMBERS, GUESTS, OBSERVERS The STP Chair welcomed the STP members and reviewed the standards for which the STPs were responsible. He reminded members that all voting will be done by ballot. Each member was asked to briefly introduce themselves. A roster was circulated to membe

27、rs to review for accuracy and to sign, indicating their presence at the meeting. ADDITIONS OR CORRECTIONS TO THE AGENDA STP members added the following items to the May 24, 2004 agenda: Robert Bonifas wanted to focus on the false alarm portion of Larry Dicherts proposal. Louis Fiore wanted to discus

28、s Voice Over Internet Protocol (VoiP). David Terrett wanted to discuss UL strengthening the EMC requirements in its standards. Louis Chavez wanted to discuss revisions for UL 294. Robert Bonifas wanted to discuss signaling across the internet. Ian Pasco wanted to discuss harmonization with IEC stand

29、ards. Dan Ryan wanted to discuss the makeup of STP 205 and STP 205A. ANNOUNCEMENTS FROM THE STP PROJECT MANAGER The interim project manager for STP 205 and STP 205A gave a presentation on the STP regulations. These regulations can be found at http:/ DISCUSSION OF AGENDA ITEMS 1. Comments received re

30、garding the proposal bulletin dated September 29, 2003 Discussion The comments were discussed by the STP members and responses were developed. Please see Appendix A. 2. Comments received regarding the ANSI ballot for UL 1641 dated October I O , 2003 Discussion The comments were discussed by the STP

31、members and responses were developed. Please see Appendix B. 3. Comments received regarding the ANSI ballot for UL 1037 dated March 19, 2004 Discussion The comments were discussed by the STP members and responses were developed. Please see Appendix C. Copyright Underwriters Laboratories Inc. Provide

32、d by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 22:20:10 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 294 -5- JULY 30,2004 4. Proposed revision to the Standard for Connectors and Switches for Use with Burglar-Al

33、arm Systems, UL 634 Discussion A proposal was submitted to UL by Larry Dischert of ADT Security Services Inc. He said that the standard makes reference to the ”maximum acceptable gap of separation” which is based upon the parameters of field installation. This gap does not have a basic minimum, othe

34、r than when it is mounted on a 1/4 inch mild steel plate. Most magnetic contacts are mounted on doors and windows whose tolerance levels vary, and are subject to change over time and weather. Therefore, a problem arises in the event of a door and window movement. This problem is well recognized and

35、even the ”Model Ordinance” includes language that deals with the movement. Mr. Dischert explained that the proposed revisions should reduce the amount of false alarms that occur. The STP members agreed to move the proposal to ballot. This will be included in a future proposal bulletin. 5. ANSI Recog

36、nition update Discussion The Chair informed the STP that UL wants to pursue ANSI approval on the following UL standards: a) Power Supplies for Use with Burglar-Alarm Systems, UL 603 b) Linings and Screens for Use with Burglar-Alarm Systems, UL 606 c) Connectors and Switches for Use with Burglar-Alar

37、m Systems, UL 634 d) Holdup Alarm Units and Systems, UL 636 e) Intrusion-Detection Units, UL 639 f) Installation and Classification of Burglar and Holdup Alarm Systems, UL 681 g) Central-Station Alarm Services, UL 827 h) Home Health Care Signaling Equipment, UL 1637 There were no objections to pursu

38、ing ANSI approval. These standards will be balloted at a later date. 6. Mechanical Strength Test for Metal Enclosures and Guards Discussion UL proposed that the mechanical strength test for metal enclosures and guards, currently found in the Standard for Control Units and Accessories for Fire Alarm

39、Systems, UL 864, be incorporated into the following standards: a) Access Control System Units, UL 294 b) Police Station Connected Burglar Alarm Units and Systems, UL 365 Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for R

40、esale, 08/29/2006 22:20:10 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 294 -6- JULY 30,2004 c) Power Supplies for Use with Burglar Alarm Systems, UL 603 d) Local Burglar Alarm Units and Systems, UL 609 e) Holdup Alarm Units and Systems, UL 636 f) Intrusion-Detec

41、tion Units, UL 639 g) Household Fire Warning System Units, UL 985 h) Household Burglar-Alarm System Units, UL 1023 i) Antitheft Alarms and Devices, UL 1037 j) Proprietary Burglar Alarm Units and Systems, UL 1076 k) Central-Station Burglar-Alarm Units, UL 161 O I) Digital Alarm Communicator System Un

42、its, UL 1635 m) Home Health Care Signaling Equipment, UL 1637 UL proposes to add this test to provide an alternative means of examining products that do not comply with the metallic enclosure thickness parameters that are currently outlined in the standards. There was some concern that the table for

43、 spacing requirements was missing from the proposed text in the agenda. UL said that they would include the table before submitting the proposal for ballot. 7. Dielectric Voltage Withstand Test Discussion UL submitted a proposal to editorially modify the Dielectric Voltage Withstand Test, Section 40

44、, in the Standard for Central-Station Burglar-Alarm Units, UL 1610. This would make the wording consistent with the wording used in the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864. The STP members agreed to advance the proposal to ballot. This will be included in a futu

45、re proposal bu Ilet in. 8. Transient Test Discussion There was some discussion regarding transient testing for the following standards: a) Access Control System Units, UL 294 b) Police Station Connected Burglar Alarm Units and Systems, UL 365 c) Power Supplies for Use with Burglar Alarm Systems, UL

46、603 d) Local Burglar Alarm Units and Systems, UL 609 e) Holdup Alarm Units and Systems, UL 636 Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=Army Northwestern Div./7838506130 Not for Resale, 08/29/2006 22:20:10 MDTNo reproduction or networking permitted witho

47、ut license from IHS -,-,- SUBJECT 294 -7- JULY 30,2004 f) Intrusion-Detection Units, UL 639 g) Household Fire Warning System Units, UL 985 h) Household Burglar-Alarm System Units, UL 1023 i) Antitheft Alarms and Devices, UL 1037 j) Proprietary Burglar Alarm Units and Systems, UL 1076 k) Central-Stat

48、ion Burglar-Alarm Units, UL 161 O I) Digital Alarm Communicator System Units, UL 1635 Dan Nita of Digital Security Controls Ltd., suggested that the IEC requirements be adopted instead of making the suggested revisions. Larry Dischert suggested that the transient test also be added to the Standard for Connectors and Switches for Use with Burglar-Alarm Systems, UL 634. A Working Group was formed to discuss the transient test and to develop a proposal. 9. Jarring Test Discussion UL proposed that the jarring test be modified in the following standards: a) Access Control System Uni