1、Subject 81 7 TO: SUBJECT: 1285 Walt Whitman Road Melville, L.I., NY 11747 November 7, 2001 Standards Technical Panel (STP) for Cord Sets and Power-Supply Cords, UL 817 Subscribers to ULs Standards Service for Other Interested Parties Cord Sets and Power-Supply Cords, UL 817 Request for Comments on P

2、roposed Requirements for the Eleventh Edition of the Standard for Cord Sets and Power-Supply Cords, UL 817; PROPOSED EFFECTIVE DATES INSTRUCTIONS STP Members: If you are a voting member of the STP, complete the attached ballot with your vote on the standard or proposals. Please note that all negativ

3、e ballots must be accompanied by supporting written reasons and, where possible, proposals for a solution to the problem raised. Impact statements and effective dates information are not subject to letter ballot. Therefore, comments regarding impact statements and effective dates may be made and sho

4、uld be sent to the STP Secretary separate from the letter ballot. Subscribers and other interested parties: If you are a subscriber or other interested party, you are requested to send comments on the proposed requirements, impact statement, and proposed effective date to the STP Secretary. The STP

5、member ballot should not be used to submit your comments. Comments should be made in writing and may be sent by fax to (631) 439-6021 or by mail to the attention of Mr. Kevin G. Mullahy at ULs Melville. Comments may also be sent via E-mail to Kevin.G.Mullahyus.uI.com. Please reference all correspond

6、ence to Subject 817. Note all comments received are public and may be circulated to others. If you respond by fax or E-mail, please include your full name and company name and address to ensure a reply. STP BALLOTS AND ALL COMMENTS DUE: JANUARY 7,2002 SUMMARY OF TOPICS This bulletin proposes the fol

7、lowing changes in requirements: Revised Requirements for Adapter Cord Sets Attached as Appendix A for your review and comment are proposed requirements for UL 817. Attached as Appendix B for your review and comment are the impact statement and proposed effective dates. Attached as Appendix C is the

8、membership roster. Appendix D and E are the STP ballot instructions COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services SUBJECT 817 -2- NOVEMBER 7,2001 and the STP ballot, respectively.

9、Questions regarding interpretation of requirements should be directed to the responsible UL Staff. Please see Appendix F of this bulletin regarding designated responsibility for the subject product category. Please note that proposed requirements are of a tentative and early nature and are for revie

10、w and comment only. Current requirements are to be used to judge a product until these requirements are published in final form. PRODUCTSANDINDUSTRIESAFFECTED BYTHE PROPOSAL UL requests your assistance in identifying other products or industries that might be affected by the requirements contained i

11、n this bulletin. UL suggests that all suppliers or customers for these products and industries be made aware of these requirements prior to their proposed effective date. Also, please forward your suggestions to UL so that these products and industries may be identified in future bu I let ins. RATIO

12、NALE The Standard for Cord Sets and Power-Supply Cords, UL 817 contains requirements for adapter cord sets which are intended for use at locations such as construction sites. As such, these cord sets are subject to cord type and length requirements specific to use in these types of locations. Accord

13、ingly, the length of such cord sets is restricted to 2 feet unless one of the following conditions is met: 1. On an adapter cord set having 2 single-outlet load fittings, the face of one of the load fittings is located no more than 2 feet from either the line or load fitting. 2. On an adapter cord s

14、et having 3 single-outlet load fittings, the face of one load fitting is located no more than 2 feet from the face of the line fitting and the faces of the other load fittings are no more than 2 feet apart. 3. The adapter cord set employs in-line fittings. UL has decided to propose to revise the len

15、gth requirements for adapter cord sets by permitting such cord sets to be up to 100 feet in length without meeting the criteria as described above. This will allow the power interconnection point at construction sites to be possibly located indoors affording protection from rain and UV exposure. In

16、addition, the additional length may reduce the risk of the user connecting cord sets together end-to-end. UL has also received inquiries from manufacturers to permit adapter cord sets employing in-line fittings to be provided with No. 14 AWG cord for lengths up to 50 feet and No. 12 AWG for lengths

17、over 50 but less than 100 feet. Presently, an adapter cord set employing in-line fittings is required to be provided with No. 12 AWG flexible cord for lengths up to 50 feet and No. 10 AWG for lengths over 50 but less than 100 feet. However, after further investigation, UL has decided to propose to p

18、ermit adapter cord sets employing in-line fittings to be provided with No. 14 AWG cord for lengths up to 50 feet and No. 12 AWG for lengths over 50 but less than 100 feet. This change is consistent with the present requirements for adapter cord sets that do not employ in-line fittings. Paragraph 37.

19、2 permits an attachment plug rated 15 A to be used in combination with a single outlet rated 20 A. However, in order to reduce the risk of overloading the attachment plug, UL has decided to propose to eliminate this type of construction. Also, UL proposes to revise the definition of adapter cord set

20、 in paragraph 2.1 and add an additional marking requirement to paragraph 41 .I to clarify the intended use of these cord sets. COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services SUBJECT

21、 817 -3- NOVEMBER 7,2001 Unless specifically requested to do so, UL will not acknowledge comments indicating concurrence with these proposals. UNDERWRITERS LABORATORIES INC. REVIEWED BY: KEVIN G. MULLAHY (Ext. 23254) Secretary for STP 817 Standards Department Fax: (631) 439-6021 E-mail: Kevin.G.M ht

22、tp:/ SR: LS GEORGE J. FECHTMANN (Ext. 22858) Chair for STP 817 Conformity Assessment Services 301 6HMEL UL 817 bulletin dated 11-07-01;KGM;cit COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling

23、Services SUBJECT 817 -Al- NOVEMBER 7,2001 APPENDIX A PROPOSED REQUIREMENTS FOR THE ELEVENTH EDITION OF THE STANDARD FOR CORD SETS AND POWER-SUPPLY CORDS, UL 817 For your convenience in review, proposed additions to existing requirements are shown underlined and proposed deletions are shown tmd-e.2(a

24、) a-d-tfp tecd i7 CCd 2c SA n / n c b V I VIIb . . Exception No. 2: Ts 3 o- be l%3fei%m A A4-A-A u /n c b V I VIIb Exception No. 3: g-wm f p : I,“,“ 8 f384rwf 40 Rating 40.1 Tables 115.1- 115.5 shall be applied to an adapter cord set. The values for cord-set lengths of 6 - 50 ft (1.8- 15.2 m) shall

25、be used for adapter cord sets less than 50 ft (15.2 m) long. COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services SUBJECT 817 -A6- NOVEMBER 7,2001 41 Marking 41.1 Each adapter cord set sh

26、all be legibly marked with all of the following: a) The type letter designation for the cord shall appear on the cord jacket. See 30.1 b) The word “outdoor” may also appear on the jacket. See 30.3. c) The electrical ratings (see Ratings, Section 40). d) The wording ”Suitable for use with outdoor app

27、liances - store indoors while not in use” (see 35.l(d) and 35.2). e) The wordina ”Intended for use on construction sites or similar locations” COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling

28、Services SUBJECT 817 Paragraphs 2.1, 36.2, 36.3, 37.1, 38.1, 38.2 and 40.1; Tables 36.1 and 36.2; Figures 36.1, 36.2, 36.3 and 36.4 Paragraphs 37.2 and 41 .I -BI- APPENDIX B Date of publication 24 months after publication IMPACT STATEMENTS AND PROPOSED EFFECTIVE DATES NOVEMBER 7,2001 I Proposed Effe

29、ctive Date I Paragraphs, Tables, Figures, or I Section Number Standard Number I UL 817 IMPACT Adoption of the proposals to eliminate adapter cord sets employing 15 A rated attachment plugs in combination with 20 A rated load fittings and the additional marking requirement would require a review of p

30、resently Listed adapter cord sets to verify compliance with the revised requirement. Therefore, UL proposes that these requirements become effective 24 months after publication. Adoption of the proposal to revise the requirements for the flexible cord length and gauge would not require a review or r

31、etest of presently Listed adapter cord sets. Therefore, UL proposes that these requirements become effective upon date of publication. COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services

32、 SUBJECT 817 Jonel Barbu George J. Fechtmann Paul A. Hedrick JoseDh A. Hertel -CI- Underwriters Laboratories Inc. User Underwriters Laboratories Inc. Non Voting State of Wisconsin. DeDartment User NIA General NOVEMBER 7,2001 Dr. M. Virginia Peart Robert Spehalski Nicholas F. Spinello Rob L. Tavlor A

33、PPENDIX C STP ROSTER FOR CORD SETS AND POWER-SUPPLY CORDS NIA General Lutron Electronics Co., Inc User Leviton Mfg. Co. Inc. Producer Panel ComDonents CorDoration Producer Name I Company I Interest Category Richard G. Alford Citv of Seattle User of Commrce Kevin G. Mullahv I Underwriters Laboratorie

34、s Inc I Non Votina Donald A. Voltz I Mustang Engineering, I nc. I General George Zelazny I Sears Roebuck and Company I User COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services SUBJECT 81

35、7 -DI- NOVEMBER 7,2001 APPENDIX D STP BALLOT FOR UL 817 (FOR STP MEMBERS ONLY) STP Ballot Instructions The STP voting member should fill out the attached ballot and send it to the STP Secretary by the stated ballot and comment due date. Only the STP member shall return the accompanied ballot. Non-vo

36、ting members should not return a ballot but may send in comments on the proposal. STP members who have indicated that they represent the general interest group comprise a category of independent consultants and experts who are generally unallied with any particular business or commercial interest. O

37、n occasion, however, independent consultants in this category may be retained by a client to advocate on behalf of the client with regard to a specific issue or issues before the STP. As to these specific issues, the STP member should not be regarded as general interest because to do so could result

38、 in a balance of interests that was not intended. Therefore, STP members categorized as general interest who have been retained to represent the interest of another with respect to a specific issue or issues which are to be addressed by an STP shall declare those interests to the Panel and record an

39、 ”abstain” vote on any proposal, comment, or matter relating to those issues. Comments that do not address proposals accompanying this ballot will either be logged for future consideration by the STP or addressed outside of the consensus process. Those comments include certification issues, includin

40、g effective dates. All negative ballots not supported by a reason will be categorized as ”negative without comment” and will not be responded to, circulated to the STP, or notified of right to appeal. COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underw

41、riters Laboratories Inc. Licensed by Information Handling Services SUBJECT 817 -El- NOVEMBER 7,2001 APPENDIX E Ballot (FOR STP MEMBERS ONLY) November 7, 2001 STP 817 Deadline for Receipt: January 7, 2002 TOPIC: Recognition of Eleventh Edition of the Standard for Safety for Cord Sets and Power-Supply

42、 Cords, UL 817 as an American National Standard QUESTION: Should this proposal be recognized for ANSI approval? YES NO ABSTAIN PROPOSAL o o o 1) Revised Requirements for Adapter Cord Sets “NO” VOTES: In accordance with ANSI procedures, in order to receive consideration, objections must be accompanie

43、d by supporting written reason. Where possible, proposals for a solution to the problem raised should be submitted. A negative ballot not accompanied by supporting written reasons will be recorded as a ”negative without comment” and is not required to be circulated. Supporting written reasons should

44、 be provided on a separate sheet. ABSTENTIONS: If you cannot vote affirmatively or negatively and want to be recorded as abstaining, please state and explain the reasons for your abstention on a separate sheet. Sianature: RETURN TO: Pieasetype or Kevin G. Mullahy print name Organization Represented

45、Secretary for STP 817 Underwriters Laboratories Inc. 1285 Walt Whitman Road Melville NY 11 747 Phone: (631) 271-6200 Fax: (631) 439-6021 Kevin.G .Mulla Phone Number (Ext. 23254) Date E-mail: COPYRIGHT Underwriters Laboratories Inc. Licensed by Information Handling Services COPYRIGHT Underwriters La

46、boratories Inc. Licensed by Information Handling Services SUBJECT 817 CCN -FI- OfficelAffiliate Responsible Engineer Extension Camas J. Glueckert 55649 Melville J. BARBU 22378 NOVEMBER 7,2001 RTP Santa Clara Guanazhou APPENDIX F B. Baker 11487 J. Herschbach 32381 Basil Shamsid-Deen 86-20-8387-7427 D

47、ESIGNATED RESPONSIBILITY FOR UL PRODUCT CATEGORY ELBZ ELBZ, CORD SETS AND POWER SUPPLY CORDS Hong Kong ChiKuen Wong 852-2695-9599 Taiwan K. Chen 886-2-891 -7642 Shang ha J. Shyu 86-21 -6279-8276 Denmark D. P. Madsen 45-44-85-65-65 Araentina G. Movano O1 1-54-1 1-4316-8210 The individuals shown in th

48、e following table are involved with the investigation of products covered under the subject category. The Primary Designated Engineer (shown in UPPERCASE letters) coordinates the establishment and uniform interpretation of UL requirements applicable to the product category. The Designated Engineers

49、(shown in lowercase letters) work with the Primary Designated Engineer to interpret requirements and maintain standards. Should you have questions regarding the interpretation of the requirements proposed in this bulletin or any adopted requirements that affect your product, you are encouraged to contact the individual at the office to which you normally submit your products. The following individual is involved with the investigation of products covered under the subject category. As the Primary Designated Engineer,