1、Subject 60730-2-7 (917, 8730-2-7) 333 Pfingsten Road Northbrook, IL 60062 February 8, 2002 TO: Electrical Council of Underwriters Laboratories Inc. Consumer Advisory Council of Underwriters Laboratories Inc. Fire Council of Underwriters Laboratories Inc. Subscribers to ULs Standards Service for Auto

2、matic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Timers and Time Switches Clock-Operated Switches SUBJECT: Request for Comments on Proposed Requirements for the First Edition of the Standard for Automatic Electrical Controls for Household and Similar Use;

3、Part 2: Particular Requirements for Timers and Time Switches, UL 60730-2-7; PROPOSED EFFECTIVE DATE SUMMARY OF TOPICS This bulletin proposes the following changes in requirements Revise UL 8730-2-7 to update that standard to the first edition of UL 60730-2-7 to be used in conjunction with the third

4、edition of UL 60730-IA. Proposed effective date schedule for the replacement of requirements for Timers and Time Switches Contained in UL 917 and UL 8730-2-7. COMMENTS DUE: March 8,2002 Attached as Appendix A for your review and comment are proposed requirements for UL 60730-2-7 Questions regarding

5、interpretation of requirements should be directed to the responsible UL Staff. Please see Appendix B of this bulletin regarding designated responsibility for the subject product categories. Please note that proposed requirements are of a tentative and early nature and are for review and comment only

6、. Current requirements are to be used to judge a product until these requirements are published in final form. PRODUCTSANDINDUSTRIESAFFECTED BYTHE PROPOSAL UL requests your assistance in identifying other products or industries that might be affected by the requirements contained in this bulletin. U

7、L suggests that all suppliers or customers for these products and industries be made aware of these requirements prior to their proposed effective date. Also, please forward your suggestions to UL so that these products and industries may be identified in future bu I let ins. Copyright Underwriters

8、Laboratories Inc. Provided by IHS under license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 10/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 60730-2-7 Date April 3, 1995 Februarv 11, 2002 -2- Activity UL published th

9、e first edition of UL 8730-2-7 UL Dublishes the first edition of UL 60730-2-7. FEBRUARY 8,2002 Until December 31, 2003 December 31, 2003 PROPOSED EFFECTIVE DATE Manufacturers have the option of investigating products to UL 917 or UL 60730-2-7. Existing products Listed or Recognized to UL 917 may ret

10、ain their Listing or Recognition. All timers and time switches covered under other categories will be transfered to the UL 60730-2-7 category. All products must comply with UL 60730-2-7. UL 917 will be withdrawn. These proposed requirements will not necessitate a review or additional testing of curr

11、ently Listed or Recognized products. Therefore, UL proposes that the new requirements become effective upon publication. However, the replacement of UL 917 with UL 60730-2-7, as explained in the Subject 917 (8730-2-7) Industry Bulletin dated February 3, 1999, will require a review of currently Liste

12、d or Recognized products. Since UL is proposing to replace UL 917 with UL 60730-2-7, which is to be used in conjunction with the third edition of UL 60730-IA (which replaced the first edition of UL 8730-I), UL is proposing the following effective date schedule for the replacement of the requirements

13、 in UL 917 with the requirements in UL 60730-2-7. UL is proposing this schedule so that product investigations take into account the updated requirements in the third edition of UL 60730-IA. This can be achieved with this schedule and a single file review. The third edition of the Standard for Autom

14、atic Electrical Controls for Household and Similar Use, Part 1: General Requirements, UL 60730-1A, was published on January 28, 2002. The proposed requirements in Appendix A would update UL 60730-2-7 to correlate that standard with the third edition O f UL 60730-IA. IMPACT The proposed revisions cla

15、rify the requirements in UL 60730-2-7. If they are adopted, they will not necessitate a review of currently Listed or Recognized products. The proposed withdrawal of UL 917 and its replacement with UL 60730-2-7 will require a review of presently Listed and Recognized timers and and time switches by

16、the effective date of December 31, 2003. Also, all timers and time switches covered under other categories will be transfered to Category Control Numbers (CCNs) WGZR, Clock-Operated Switches, and WGZR2, Clock-Operated Switches - Component. REQUEST FOR COMMENTS ON PROPOSALS Please provide the followi

17、ng: 1. Your comments concerning the proposed requirements; and 2. Your comments concerning the proposed effective date, should the proposals be adopted Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 10

18、/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 60730-2-7 -3- FEBRUARY 8,2002 Written comments should be sent by regular mail, fax, or e-mail to the attention of Alan McGrath at ULs Northbrook office, 333 Pfingsten Road, Northbrook, IL 60062. Pleas

19、e reference all correspondence to Subject 60730-2-7. If you respond by fax or e-mail, please include your full name and company address to ensure a reply. All comments should be sent by March 8, 2002. Unless specifically requested to do so, UL will not acknowledge comments indicating concurrence wit

20、h these proposals. UNDERWRITERS LABORATORIES INC. REVIEWED BY: ALAN MCGRATH (Ext. 43038) Staff Engineer Standards Department Fax: (847) 509-6217 E-mail: Alan.T.McG KENNETH BART0 (Ext. 22573) Staff Engineer Engineering Services 301 5J SR: JM Copyright Underwriters Laboratories Inc. Provided by IHS un

21、der license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 10/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 60730-2-7 -Al- FEBRUARY 8,2002 APPENDIX A PROPOSED REQUIREMENTS AND PROPOSED EFFECTIVE DATES FOR THE FIRST EDIT

22、ION OF THE STANDARD FOR AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE; PART 2: PARTICULAR REQUIREMENTS FOR TIMERS AND TIME SWITCHES, UL 60730-2-7 For your convenience in review, proposed additions to existing requirements are shown underlined and proposed deletions are shown tmd-ek. TT

23、 ef !JL ; fie, 4keck i- , . . RATIONALE UL proposes the following revision to the UL deviation contained in clause 11.9A. This revision would result in identical requirements as are required for similar type equipment like photo controls and a ppl ia nce control s. Copyright Underwriters Laboratorie

24、s Inc. Provided by IHS under license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 10/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 60730-2-7 -A2- FEBRUARY 8,2002 IMPACT If the revision is adopted, it would not require

25、 a review, retest, or modifications to currently Listed or Recognized products. PROPOSAL 11.9DV D2 Modification to 11.9 of the UL part I by adding the following: 11.9DV.1 Independently mounted 11.9DV.1.1 The flexible cord is to be of jacketed construction not lighter than Type SJ; except that a devi

26、ce having a maximum rating of 2,000 VA, 1 hp, or 300 V, may be provided with a cord not lighter than Type SP-2. The flexible cord shall have a minimum length of 4-8 6 inch (152 mm) and shall not exceed 10 ft (3.05 m). RATIONALE UL proposes to add the following UL deviations to clause 11. This added

27、section was originally in UL 917 and should remain in UL 60730-2-7. IMPACT If the proposed added requirements are adopted, they would not require a review, retest, or modifications to currently Listed or Recognized products. PROPOSAL (NEW SECTION) 11 .I O1 DV D2 Addition: 11.1OIDV.I Plug-in devices

28、11.101 DV.l .I A clock-operated switch having attachment-plug blades for plug-in connection to a receptacle outlet rated 15 A, 125 V, and having the ANSIINEMA WD6-1988 slot configuration shall have a mass of 28 oz (0.79 kg) or less. The moment, center of gravity, and dimensions shall not exceed the

29、limits specified in 11 .I O1 DV.1.2. 11 .IO1 DV.1.2 The moment, center of gravity, and dimensions of a clock-operated switch, see Figure 11.1OIDV.1, shall comply with each of the following: a) The quotient of W I Z shall not exceed 48 oz (1.36 kg). b) The quotient of WYIS shall not exceed 48 oz. c)

30、The product of WX shall not exceed 80 oz-inch (0.56 N-m). d) The dimension Z3 shall not exceed 3-II4 inches (82.6 mm). e) The dimensions SI, Spi Z, and Z, shall not exceed 5 inches (127 mm). Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=North Carolina State U

31、niversity/5618801100 Not for Resale, 10/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 60730-2-7 -A3- FEBRUARY 8,2002 11.101DV.1.3 Definitions for the symbols used in 11.101DV.1.2 are as follows: W is the weight of the switch in ounces (kg), Y is i

32、n inches (mm), Z is the smaller of Z, or Z, in inches (mm), S is the smaller of SI or S2 in inches (mm), and X is the larger of XI or X2 in inches (mm). Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 1

33、0/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 60730-2-7 -A4- FEBRUARY 8,2002 Figure 11.1OIDV.I Plug-in device limits of dimensions I- J z, - X,+ - z2 - SIDE VIEW C.G. = Center of Gravity CP1 O0 Copyright Underwriters Laboratories Inc. Provided b

34、y IHS under license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 10/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 60730-2-7 -A5- FEBRUARY 8,2002 RATIONALE UL proposes to delete the following UL deviation to clause 12.

35、3. This requirement is already in UL 60730-1, the Part 1 standard, and does not need to be repeated. IMPACT If the deletion is adopted, it would not require a review, retest, or modifications to currently Listed or Recognized products. PROPOSAL (DELETED) RATIONALE UL proposes to delete the following

36、 UL deviation to clause 17.16.103.5A. This requirement is already in UL 60730-1A, the Part 1 standard, and does not need to be repeated. IMPACT If the deletion is adopted, it would not require a review, retest, or modifications to currently Listed or Recognized products. PROPOSAL (DELETED) A i n 17

37、I C -in13 r u II I I I I V IVU.U, a RATIONALE UL proposes to delete the following UL deviations to clause 18.9. These clauses are already in UL 60730-1A, the Part 1 standard, and they do not need to be repeated. IMPACT If the deletions are adopted, they would not require a review, retest, or modific

38、ations to currently Listed or Recognized products. PROPOSAL (DELETED) Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 10/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from

39、IHS -,-,- SUBJECT 60730-2-7 -A6- FEBRUARY 8,2002 RATIONALE UL proposes to add the following deviation to Annex H. This addition would clarify the current U.S practice for this category. IMPACT If the proposed addition is adopted, it would not require a review, retest, or modifications to currently L

40、isted or Recognized products. PROPOSAL H26.2.1 DV D2 Addition: For TvQe 1 devices. t he tests o f H26.8 and H26.9 are not a m licable in the US. RATIONALE UL proposes to delete Annex X3. This requirement is already in UL 60730-1A, the Part 1 standard, and it does not need to be repeated. IMPACT If t

41、he deletion is adopted, it would not require a review, retest, or modifications to currently Listed or Recognized products. PROPOSAL (DELETED) Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 10/21/2006

42、20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJECT 60730-2-7 -A7- FEBRUARY 8,2002 RATIONALE UL proposes to renumber Annex X8 to Annex X5 to align with the Annex numbering contained in the third edition of UL 60730-IA. Also, UL proposes to revise ?nonpolarized?

43、 to ?polarized? in the fourth ?dashed? sentence of clause X5.78. These are considered editorial corrections. IMPACT If the proposed revisions are adopted, they would not require a review, retest, or modifications to currently Listed or Recognized products. PROPOSAL Grounding DVE.1.8 X3+8 If the inte

44、gral blades of a plug-in switch are - not polarized, the receptacle(s) provided as part of the plug-in switch shall be of the nonpolarized type, - polarized, the receptacle(s) provided shall be of the polarized type, or - of the grounding type, the receptacle(s) provided shall be of the grounding ty

45、pe. If the power supply cord of a cord-connected switch has - a polarized attachment plug, the receptacle(s) provided as part of the plug-in switch shall be of the mmpolarized type, - a nonpolarized attachment plug, the receptacle(s) provided shall be nonpolarized, or - a grounding type attachment p

46、lug, the receptacle(s) shall be of the grounding type. Copyright Underwriters Laboratories Inc. Provided by IHS under license with ULLicensee=North Carolina State University/5618801100 Not for Resale, 10/21/2006 20:33:35 MDTNo reproduction or networking permitted without license from IHS -,-,- SUBJE

47、CT 60730-2-7 RTP Santa Clara UL Canada Asia -BI- Isaac Clark 11 608 Hung Nguyen 32751 Torn Mah 61 51 O Kent Chen +886 2 2896 7790 FEBRUARY 8,2002 Hong Kong Europe (RDE) Europe APPENDIX B Andy Leung +852 2695 9599 Harnid Syed Harnid Sved + 44 (O) 1483 302 130 + 44 (O) 1483 302 130 DESIGNATED RESPONSI

48、BILITY FOR UL PRODUCT CATEGORIES WDGW2, CLOCK-OPERATED SWITCHES EVALUATED IN ACCORDANCE WITH IEC PUBS - COMPONENT WGLT, AUTOMATIC SWITCHES W GZR , CLOCK- OP E RAT ED SWITCH ES WGZR2, CLOCK-OPERATED SWITCHES - COMPONENT SDFY, REFRIGERATION CONTROLLERS SDFY2, REFRIGERATION CONTROLLERS, COMPONENT XAPX, TEMPERATURE - INDICATING AND REGULATING EQUIPMENT XAPX2, TEMPERATURE - INDICATING AND REGULATING EQUIPMENT - COMPONENT XAWW2, TEMPERA