电信EWSD PAD Vanguard 6435.doc

上传人:土8路 文档编号:10252971 上传时间:2021-05-03 格式:DOC 页数:12 大小:56KB
返回 下载 相关 举报
电信EWSD PAD Vanguard 6435.doc_第1页
第1页 / 共12页
电信EWSD PAD Vanguard 6435.doc_第2页
第2页 / 共12页
电信EWSD PAD Vanguard 6435.doc_第3页
第3页 / 共12页
电信EWSD PAD Vanguard 6435.doc_第4页
第4页 / 共12页
电信EWSD PAD Vanguard 6435.doc_第5页
第5页 / 共12页
点击查看更多>>
资源描述

《电信EWSD PAD Vanguard 6435.doc》由会员分享,可在线阅读,更多相关《电信EWSD PAD Vanguard 6435.doc(12页珍藏版)》请在三一文库上搜索。

1、Procedure of Install PAD Vanguard 64351. Database for creating X.25 link for PAD EWSD V9 onward in CP113 or CP113C/*/* CREATE I/O PROCESSORS FOR LAU */*/CMDFILE;SETCFOPT:ACKCFS=ERROR,DANCMD=EXEC,ACKREQ=POS;/CRIOP:IOC=1,BIOC=11,IOP=IOPLAU-0,IOPR=IOPLAU-1,BIOCR=11,LOADTP=100,LDPRTY=LOW;CONFIOP:IOP=IOP

2、LAU-0,OST=MBL;CONFLAU:LAU=0,OST=MBL;/* X25 LINK FOR PVC DIALOG FUNCTION VIA PAD/CRX25LINK:X25LINK=1,LAU=0,CHAN=1,NET=X25LC,PRTCL=BX25,L1BAUD=B64000,L1DTT=DTE,#L1IF=V24,L1MCA=1,L2DTT=DCE,L2LAM=INITIA,L2N2=10,L2N1=135,L3DTT=DCE,L3T25=1500;(L1IF=X21/V35 when PAD using X21/V35 DIM module interface)/CONF

3、X25LINK:X25LINK=1,OST=MBL;/CONFIOP:IOP=IOPLAU-0,OST=ACT;/CONFLAU:LAU=0,OST=ACT;/* LOCAL OSI ADDRESS AND TH25 APPLICATION CROSIADR:ADRNAM=OSILOCH,NSADR=48-0-02,NET=X25LC;CRAPPL:APPLID=TH25,PRONAM=CP02,ADRNAM=OSILOCH; ( CP02 : CP processors name)/* REMOTE OSI-ADDRESSES FOR TH25CROSIADR:ADRNAM=OSIRTH01

4、,NSADR=48-0-50,NET=X25LC,LOCADR=OSILOCH;CROSIADR:ADRNAM=OSIRTH02,NSADR=48-0-51,NET=X25LC,LOCADR=OSILOCH;CROSIADR:ADRNAM=OSIRTH03,NSADR=48-0-52,NET=X25LC,LOCADR=OSILOCH;CROSIADR:ADRNAM=OSIRTH04,NSADR=48-0-53,NET=X25LC,LOCADR=OSILOCH;/* REMOTE PROCESSORS FOR TH25CRPRO:PRONAM=TH2501,PROTYP=OMTA; (EWSD-

5、OMT)CRPRO:PRONAM=TH2502,PROTYP=OMTA;CRPRO:PRONAM=TH2503,PROTYP=OMTA;CRPRO:PRONAM=TH2504,PROTYP=OMTA; /* REMOTE TH25 APPLICATIONSCRAPPL:APPLID=DIAL1,PRONAM=TH2501,ADRNAM=OSIRTH01,AUT=1;CRAPPL:APPLID=DIAL1,PRONAM=TH2502,ADRNAM=OSIRTH02,AUT=1;CRAPPL:APPLID=DIAL1,PRONAM=TH2503,ADRNAM=OSIRTH03,AUT=1;CRAP

6、PL:APPLID=DIAL1,PRONAM=TH2504,ADRNAM=OSIRTH04,AUT=1; ( APPLID=DIAL2,when processors used for ALARM data output and TRAFFIC data output)/*PVC FOR LINKSCRX25PVC:PVCNAM=THPVC001,ADRNAM=OSIRTH01,X25LINK=1,CHNO=11,PCKSZ=128-128;CRX25PVC:PVCNAM=THPVC002,ADRNAM=OSIRTH02,X25LINK=1,CHNO=12,PCKSZ=128-128;CRX2

7、5PVC:PVCNAM=THPVC003,ADRNAM=OSIRTH03,X25LINK=1,CHNO=13,PCKSZ=128-128;CRX25PVC:PVCNAM=THPVC004,ADRNAM=OSIRTH04,X25LINK=1,CHNO=14,PCKSZ=128-128;/CONFX25LINK:X25LINK=1,OST=ACT;RESETCFOPT;ENDFILE;2. Upgrade PAD FW (54p01a to 54p0fa)1). Requirementa. CD ( Motorola Vanguard 6435/6455 IP 5.4P01A) which is

8、delivered together with PAD 6435. b. Floppy disk (with three files - v54p0fa.exe ,54P0FAo01.DES and STANDARD.MEM ) which is provided by SE_TS1;c. PC using your own notebook PC or using any desk PC with CD_ROM.2).Install configuration toolsa. Insert cd(Motorola Vanguard 6435/6455 IP 5.4P01A) into cd-

9、rom;b. Execute file E:installvgsetup;c. Select directory c:motorola;d. Select “NEXT” until installation finished. 3).Install upgrade filea. Insert floppy disk to Drive A;b. execute file a:v54p0fa.exe;c. Select cd-rom drive E: ;d. Select install directory c:motorola;e. Select “NEXT” until installatio

10、n finished;f.Copy a:54P0Fao01.des to c:motorolasfw_imgsv6400.4).Upgrade PAD FWa.Execute file c:motorolasfw_imgsv640054P0FAo01.des,Vanguard Software Builder window will occurred;b.After input the corret licenses number(CD licenses) ,fill the options:Release : 5.4.p0fa;Product : Vanguard 6400;Memory S

11、ize: 32M Bytes;Flash Size: 4M Bytes;Image Name : BISC;Option Number: 01;Software Licenses Available: IP.c.Click “Create Option” button, and wait a few minutes;d.When “Do you want to load” window occur, selected Yes;e.Vanguard Software Loader window will occur, fill options:Drive: C: ;Product: V6400

12、;Release: r54pp0fa;Image Name: 54P0Fao01.zip;Comm Port: COM1 or COM2;Speed: 115200.( you can change the speed by Win NT Control panel/ports )f.Connect the PC COM to PAD port4 with Cable 5, then click the “LOAD”Button. So the 540fa APS will load to the PAD. After click the ButtonOf “OK”, the upgrade

13、working finished.3.Configure PAD database automaticallyIf PADs configuration is standard, you can upload the standard database from file A:STANDARD.MEM. Else you must configure the PADs database by hand. a. Copy a:STANDARD.MEM c:MOTOROLACONFIGS/V6400Uploadb. Execute file c:motorolavanguidecmem32.exe

14、;c. Vanguard Configuration Loader window will occur, fill options:Drive: C: ;Product: V6400;Application: upload;d. Select STANDARD.MEM as the configuration file and click “LOAD” Button,PAD database will be configure automatically.4. Setting PAD Parameter Values By Hand1). PAD motorola 6435Port1 -for

15、 X.25 link connection to EWSD IOPSCDP.-DIM V.24 or DIM X.21,V.35 also can be used -port 1,2 physical address must be set to DCE location when PAD directly connecte to IOPSCDP, when via modem it must be set to DTE. -If only one X.25 link used the other port can be used for connection terminal VT100 o

16、r OMT, then the DIM must be set to DCE location. Port3-5only port4 used to connect PC for modify PAD parameter . Port2,7,10,13 PAD port connection OMT or VT100 . evey port must haveR232 DIM chip inside for V24 protocal , under the DIM chip where are 8 swith , switch1-5 set to “ on “ and switch6-8 se

17、t to “ off “ .Front view of PAD LCD DISPLAY Rear view of PAD Port13Port10Port7 543Port2Port1 Power power Switch cable3.) Setting PAD Parameter ValusLink PAD with PC 5 PORT4 COM16435 VT100 terminal connection cable form port4 to PC is supplied by MOTOROLA .Connection the VT100 (or use Vaguard Termina

18、l)to PAD port4 and power on PAD and PC,the VT100 terminal will show OK , type ATDS , then input Password ( type ENTER)the main menu appears.A. Node setupMenu 6: CONFIGURESubmenu 1: NODENode Address1B. Port setupSubmenu2: PortPort configuration 1Port Address1Port typeX25Clock SourceINT ( EXT when X25

19、 link via modem)Clock Speed64000Link AddressDTENumber of PVC C hannels5Starting PVC Channels Number11Number of SVC Channels0X.25 OptionsCausePort Address1Port Configuration 2-13Port Address2Port typePADConnection TypeDTRData Bits per Character7Device ParityEVENProfile NameEWSD-OMT or VT100 or DEFAUT

20、C. PVC table setupMenu 6.3.2 : PVC SETUP TABLEEntry Number 1Source X25-1(11)DestinationPAD-2Entry Number 2Source X25-1(12)DestinationPAD-7Entry Number 3Source X25-1(13)DestinationPAD-10Entry Number 4Source X25-1(14)DestinationPAD-13D. Profile Table SetupMenu 6.10:PAD Profile TableEntry Number 1Profi

21、le NameDEFAUTEntry Number 2Profile NameEWSD-OMT#1 PAD Recall0#2 Echo0#3 Data Forwarding Character4+16#5 Device Flow Control1#6 Service Control Signals0#7 Break Signal Operating0#13 Line Feed Insertion after CR0#15 Editing0#16 Charater Delete0#17 Line Delete0#18 Line Display0#19 Editing Type0#21 Pari

22、ty Treatment3#106 Network Parity1#110 ESC Forwardind Delay0Entry Number 3Profile NameVT100#3Data Forwarding Character2+16+32#5Device Flow Control1#6Service Control Signals0#7Break Signal Operating0#17Line Delete127#20Echo Mask16+32+128#21Parity Treatment3#106Network Parity1E. BOOTMenu 7.5 NODE(Cold)

23、 3. Cable list 1 OR 8V24(DCE)V24(DTE)X21(DCE)X21(DTE)V35(DCE)V35(DTE)PADIOP:SCDPX25M:LAUMM 1OR8 6 OR 7 3 2 4 5 TMNMM 2OR9 6 OR 7 13 11or 14 10MM 11/14 6 OR 7 12CABLE CODE NUMBER Supplied byLength 1S38228-Z77-A150 (floor)BISC15M 2S38228-Z76-A150 (floor)BISC 15M 3V24-M-A15 Motorola 15M 4X21-C-A05 Moto

24、rola5M 5V24-C-A15Motorola15M 6a/b x2 Customer12KM 7a/b Customer8KM 8S38228-Z47-A150 (w/o floor)BISC15M 9S38228-Z46-A150 (w/o floor)BISC 15M10 V35-C-A05Motorola5M11 S38228-Z49-A150 (floor)BISC15M12 V35-M-A15Motorola15M13 X21-M-A15Motorola15M14 S38228-Z48-A150 (w/o floor)BISC15MCable 5 : V.24 DB9F-DB2

25、5M( RS-232C)DTEDCE 1 8CD 2 3RD 3 2TD 4 20DTR 5 7SG 6 6DSR 7 4RTS 8 5CTS 9 22RIfemalemaleCable 3 : V.24 DB25M-DB25M Crossover 1 1 2 3 3 2 4 8 5 14 6 20 7 7 8 4 14 5 15 18 17 24 18 15 20 6 22 25 24 17 25 22 16 21 21 16 male maleCable 4 : X.21 DB15F-DB25M Cable 13 : X.21 DB15M-DB25M 2 2 3 4 4 3 5 8 6 1

26、5 8 7 9 14 10 20 11 16 12 6 13 21femalemale ( cable 4 )malemale ( cable 13 )Cable 10 : V.35 DB25M-DB34FCable 12 : V.35 DB25M-DB34M2-P14-S3-R16-T15-Y21-AA17-V18-X24-U22-W4-C5-D6-E7-B8-F20-H25-Nmalefemale (cable 10 )malemale (cable 12 )5. Insert PADs SoftWare Keya. Connect PAD to PC COM port with VT10

27、0 or Vanguard Terminal; b. Type “entr” and ATDS to enter main menu;c. Select 6-Configuration ;d. Select 15-Software Key Table;e. Type key value nx849nzlk2w84b9pdchw at entry number:1/ ;f. Type “ESC” return to main menu and prepare to check the result;a. Select 5 Status/Statistics 12 Software option statisics. If you see “00005 PVCS send Reset to reflect Eia state”, the SW-KEY hasbeen added successfully. Please contact SE_TA1 Mr. Liu Ruixin Tel. 578 or Mr. Wu Xjianfeng Tel. 578 if you have any question or you find any problem during your operation and maintenance of PAD 6435.

展开阅读全文