《【BS英国标准】BS EN 523-1997 Steel strip sheaths for prestressing tendons. Terminology, requirements, quality control.doc》由会员分享,可在线阅读,更多相关《【BS英国标准】BS EN 523-1997 Steel strip sheaths for prestressing tendons. Terminology, requirements, quality control.doc(18页珍藏版)》请在三一文库上搜索。
1、国内外标准大全豆丁网国内外标准下载地址 http:/ Copy: sheffieldun sheffieldun, na, Mon Nov 06 02:02:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSIBRITISH STANDARD BS EN523:1997Steel strip sheaths for prestressing tendons Terminology, requirements, quality controlThe European Standard EN 523:1997 has the status of aBritis
2、h StandardICS 01.040.77; 01.040.91; 77.140.75; 91.080.40BS EN 523:1997National forewordThis British Standard is the English language version of EN 523:1997. The UK participation in its preparation was entrusted by Technical Committee B/525, Building and civil engineering structures, to Subcommittee
3、B/525/2, Structural use of concrete, which has the responsibility to: aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European devel
4、opments and promulgate them in the UK.A list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogu
5、e under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue.A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their corre
6、ct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages 2 to 10 and a back cover.This standard has been updated (see copyright da
7、te) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 02:02:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSIAmd. No.DateCommentsThis British Standard, having been prepared under the di
8、rection of the Sector Board for Materials and Chemicals, was published under the authorityof the Standards Board and comes into effect on15 November 1997 BSI 04-2000ISBN 0 580 28665 7Amendments issued since publicationLicensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 02:02:53 GMT+00:00 2006, Un
9、controlled Copy, (c) BSIBS EN 523:1997ContentsPage National forewordInside front cover Foreword2Test of EN 5233 BSI 04-2000iiiblankLicensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 02:02:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSIEUROPEAN STANDARD NORME EUROPENNEEUROPISCHE NORMEN 523March 199
10、7ICS 77.140.75; 91.080.40Descriptors: Prestressed concrete, cables, ropes, sheaths, protectors, strips, steels, plastics, classifications, specifications, quality control, markingEnglish versionSteel strip sheaths for prestressing tendons Terminology, requirements, quality controlGaines en feuillard
11、 dacier pour cbles de prcontrainte Terminologie, prescriptions, contrle de qualitHllrohre aus Bandstahl fr Spannglieder Begriffe, Anforderungen, GteberwachungThis European Standard was approved by CEN on 1997-01-27. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stip
12、ulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exi
13、sts in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions.CEN members are the national standards bod
14、ies of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.CENEuropean Committee for Standardization Comit Europen de Normalisation Europisches Komitee fr NormungCentral Secreta
15、riat: rue de Stassart 36, B-1050 BrusselsLicensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 02:02:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI 1997 Copyright reserved to CEN members.Ref. No. EN 523:1997 EEN 523:19979 BSI 04-2000Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 02:02:53 GMT
16、+00:00 2006, Uncontrolled Copy, (c) BSIForewordThis European Standard has been prepared by Technical Committee CEN/TC 104, Concrete (performance, production, placing and compliance criteria), the Secretariat of which is held by DIN.This European Standard shall be given the status of a national stand
17、ard, either by publication of an identical text or by endorsement, at the latest by September 1997, and conflicting national standards shall be withdrawn at the latest by September 1997.This European Standard applies together with the standards of the EN 524 series which comprises test methods for s
18、heaths.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Sp
19、ain, Sweden, Switzerland and the United Kingdom.ContentsPageForeword21Scope32Normative references33Definitions 34Classification35Requirements36Marking, technical documents,delivery note57Storage68Quality control procedures6Annex A (informative) Explanatory notes9Figure 1 Dimensions of couplers6Table
20、 1 Minimum requirements4Table 2 Routine checks as specified inclause 8.2.3 and 8.2.4 7Table 3 Testing of characteristics asspecified in clause 5 81 ScopeThis standard is applicable to uncoated cylindrical steel sheaths with a corrugated profile and with a nominal internal diameter of up to 130 mm1)
21、and their connectors (couplers) which are assembledto form ducts for prestressing tendons inpost-tensioned prestressed concrete elements. It isonly applicable to sheaths and connectors made of interlocked or welded steel strip2)3).The seals required between sheaths and couplers are not covered by th
22、is standard4).2 Normative referencesThis European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendment
23、s to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.EN 524-1, Steel strip sheaths for prestressing tendons Methods of test Part 1: Determ
24、ination of shape and dimensions.EN 524-2, Steel strip sheaths for prestressing tendons Methods of test Part 2: Determination of flexural behaviour.EN 524-3, Steel strip sheaths for prestressing tendons Methods of test Part 3: To-and-fro bending test.EN 524-4, Steel strip sheaths for prestressing ten
25、dons Methods of test Part 4: Determination of lateral load resistance.EN 524-5, Steel strip sheaths for prestressing tendons Methods of test Part 5: Determination of tensile load resistance.EN 524-6, Steel strip sheaths for prestressing tendons Methods of test Part 6: Determination of leaktightness
26、(Determination of water loss).ISO 6932, Cold-reduced carbon steel strip with a maximum carbon content of 0,25 %.3 Definitions3.1types of sheathsheaths are designated by the manufacturer according to type, each type having certain features, e.g. production procedure (welded or interlocked), shape of
27、profile, etc3.2connectors (couplers)connectors are specific devices to join sheath sections. They are usually made from cut ends of sheaths with the same profile type but with larger diameter (see 5.2)3.3 stiffenersstiffeners are additional components whose purpose is to increase the lateral load st
28、rength of the sheaths at supporting points, e.g. semi-circular sheathing sections placed between supports and tendons4 ClassificationSheaths are classified by the requirements as given in Table 1.Class 1 (normal sheaths) Class 2 (rigid sheaths)5 Requirements5.1 Sheaths5.1.1 General requirementsSheat
29、hs shall have sufficient strength to ensure that they are able to withstand varying degrees and types of mechanical loading.Sheaths shall have a corrugated profile to provide a sufficient mechanical bond with the concrete externally and the grout internally.The inner and outer surfaces of the sheath
30、s shall be free of any detrimental corrosion (see clause 7). Sheaths shall be leaktight (see 5.1.9). All joints between sheaths shall be sealed carefully(see Annex A). The sheaths and their connectors shall be designed in such a way to allow this propersealing of the joints.Licensed Copy: sheffieldu
31、n sheffieldun, na, Mon Nov 06 02:02:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI1) For diameters greater than 130 mm requirements should be drawn up on the basis of this standard and agreed upon by the parties involved.2) In case of coated or galvanized steel additional provisions have to be consid
32、ered, which are not covered by this standard.3) For plastic sheaths, see Annex A.4) The appropriate rules will be specified in a separate European Standard for concrete structures which is under preparation.5.1.2 Steel stripSheaths shall be made from rolled steel strip conforming to ISO 6932 or spec
33、ifies steel with similar properties. The nominal thickness of the steel strip shall be not less than the values given in Table 1, lines 1a and 1b.5.1.3 Tolerances (ovality)Deviations from the mean values of the internal diameter of any cross-section of the sheaths determined according to EN 524-1 sh
34、all notexceed 1 % or 0,5 mm, whichever is the greater.5.1.4 Relative volume of the profileThe relative volume of the profile Vrel determined in accordance with EN 524-1 shall be not lessthan 0,08 cm3/cm2. For nominal internal diameters greater than 25 mm, the height of the profile shallbe not less t
35、han 2,5 mm (see EN 524-1).5.1.5 Flexural behaviourThe relative load Frel = Fpl/d1 in N/mm and the load Fpl at the beginning of plastic deformation shall be determined in accordance with EN 524-2.The relative load Frel for class 2 shall not be less than the given values in Table 1, line 2.For class 1
36、 there are no requirements but test results shall be given for information to the user in the relevant documents (see 6.2).5.1.6 FlexibilityWhen tested by means of the to-and-fro bending test described in EN 524-3, flexibility is sufficient if, after the bending test, no significant deformations of
37、the corrugation appear so that the plunger can push in the specimen in whole length. A straighteningof the specimen by means of the tensile load test(see EN 524-5) is permitted.5.1.7 Lateral load resistanceThe irreversible reduction of the internal diameter shall not exceed 10 % or5 mm whichever is
38、the smaller when the loads given in Table 1, lines 4ato 4c are applied according to EN 524-4. If any type of sheaths of class 1 withstands the loadFl = 1 500 N without a stiffener a test with lower forces accordance to Table 1, line 4a is not required.5.1.8 Tensile load resistanceWhen loaded in acco
39、rdance with EN 524-5, the tensile load strength is sufficient if the sleeve coupling (comprising sheaths and the corresponding coupler) does not fall by complete separation under the test loads specified in Table 1, line 5.5.1.9 LeaktightnessWhen tested in accordance with EN 524-6, using a specimen
40、tested earlier for flexibility, lateral load resistance and tensile load resistance, the water loss shall not exceed the values given in Table 1, line 6.Licensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 02:02:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSITable 1 Minimum requirements1234567891011
41、CharacteristicClassNominal internal diameter d1 in mmk 25over 25 to 35over 35 to 45over 45 to 55over 55 to 65over 65 to 75over 75 to 85over 85 to 100over 100 to 1301aNominal thickness of steel strip in mm10,200,250,250,300,300,350,350,40U 0,401b20,400,450,450,500,500,60U 0,602Relative load Fpl/d1in
42、N/mm23,03,54,04,04,55,05,56,06,53aRadius r for the flexibility test,in mm (maximum values)17507507507507507507509001 0003b21 5001 5001 5001 5001 5001 5001 5001 8001 8004aLateral load Fl in Nwithout stiffeners15006007507509509509501 0501 0504bwith stiffeners11 5001 5001 5001 5001 5001 5001 5001 5001
43、5004cwithout stiffeners21 5001 5001 5001 5001 5001 5001 5001 5001 5005Tensile load F2 in N1 and 22504006009001 1001 4001 6001 9002 2006Tightness1 and 2Water loss k 1,5 % by volumeLicensed Copy: sheffieldun sheffieldun, na, Mon Nov 06 02:02:53 GMT+00:00 2006, Uncontrolled Copy, (c) BSI5.2 Connectors
44、(couplers)5.2.1 General requirementsCouplers made from corrugated metal strip sheaths shall fulfil the requirements given in 5.1.1.5.2.2 Minimum lengthThe length of the couplers shall be at least three times the nominal internal diameter of the sheaths, but not less than 150 mm.5.2.3 Nominal interna
45、l diameter and wall thickness of the couplersWhen measured in accordance with EN 524-1, the nominal internal diameter of the couplers d1,c shall not exceed a value ofd1,c = d1,s + 8ts + c (for interlocked sheaths)d1,c = d1,s + 3ts + c (for welded sheaths)where (see also Figure 1)d1,s is the nominal internal diameter of the sheath (in mm)tsis the nominal wall thickness of the