AS 3823-2-2005 Performance of electrical appliances— Airconditioners and heat pumps Part 2 Energy labelling and minimum energy performance standard (MEPS) requirements.pdf

上传人:韩长文 文档编号:3641869 上传时间:2019-09-19 格式:PDF 页数:73 大小:1.59MB
返回 下载 相关 举报
AS 3823-2-2005 Performance of electrical appliances— Airconditioners and heat pumps Part 2 Energy labelling and minimum energy performance standard (MEPS) requirements.pdf_第1页
第1页 / 共73页
AS 3823-2-2005 Performance of electrical appliances— Airconditioners and heat pumps Part 2 Energy labelling and minimum energy performance standard (MEPS) requirements.pdf_第2页
第2页 / 共73页
AS 3823-2-2005 Performance of electrical appliances— Airconditioners and heat pumps Part 2 Energy labelling and minimum energy performance standard (MEPS) requirements.pdf_第3页
第3页 / 共73页
AS 3823-2-2005 Performance of electrical appliances— Airconditioners and heat pumps Part 2 Energy labelling and minimum energy performance standard (MEPS) requirements.pdf_第4页
第4页 / 共73页
AS 3823-2-2005 Performance of electrical appliances— Airconditioners and heat pumps Part 2 Energy labelling and minimum energy performance standard (MEPS) requirements.pdf_第5页
第5页 / 共73页
亲,该文档总共73页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《AS 3823-2-2005 Performance of electrical appliances— Airconditioners and heat pumps Part 2 Energy labelling and minimum energy performance standard (MEPS) requirements.pdf》由会员分享,可在线阅读,更多相关《AS 3823-2-2005 Performance of electrical appliances— Airconditioners and heat pumps Part 2 Energy labelling and minimum energy performance standard (MEPS) requirements.pdf(73页珍藏版)》请在三一文库上搜索。

1、 AS/NZS 3823.2:2005 Australian/New Zealand Standard Performance of electrical appliances Airconditioners and heat pumps Part 2: Energy labelling and minimum energy performance standard (MEPS) requirements AS/NZS 3823.2:2005 AS/NZS 3823.2:2005 This Joint Australian/New Zealand Standard was prepared b

2、y Joint Technical Committee EL-015, Quality and Performance of Household Electrical Appliances. It was approved on behalf of the Council of Standards Australia on 8 December 2005 and on behalf of the Council of Standards New Zealand on 21 December 2005. This Standard was published on 30 December 200

3、5. The following are represented on Committee EL-015: Australian Association of Certification Bodies Australian Consumers Association Australian Electrical and Electronic Manufacturers Association Australian Industry Group Australian Retailers Association Business New Zealand Consumer Electronic Sup

4、pliers Association Department of Minerals and Energy, Qld Department of Industrial Relations, Qld Electrical Compliance Testing Association Energy Efficiency and Conservation Authority New Zealand Ministry of Energy and Utilities, New South Wales National Appliance and Equipment Energy Efficiency Co

5、mmittee National Association of Testing Authorities Australia New Zealand Manufacturers Federation Office of the Chief Electrical Inspector, Victoria Office of the Technical Regulator, South Australia Additional Interests: Air Conditioning and Refrigeration Equipment Manufacturers Association Instit

6、ute of Refrigeration Heating and Air Conditioning Engineers of New Zealand Institution of Professional Engineers New Zealand Primary Industries and Resources, South Australia Testing Interest Australia Keeping Standards up-to-date Standards are living documents which reflect progress in science, tec

7、hnology and systems. To maintain their currency, all Standards are periodically reviewed, and new editions are published. Between editions, amendments may be issued. Standards may also be withdrawn. It is important that readers assure themselves they are using a current Standard, which should includ

8、e any amendments which may have been published since the Standard was purchased. Detailed information about joint Australian/New Zealand Standards can be found by visiting the Standards Web Shop at .au or Standards New Zealand web site at www.standards.co.nz and looking up the relevant Standard in t

9、he on-line catalogue. Alternatively, both organizations publish an annual printed Catalogue with full details of all current Standards. For more frequent listings or notification of revisions, amendments and withdrawals, Standards Australia and Standards New Zealand offer a number of update options.

10、 For information about these services, users should contact their respective national Standards organization. We also welcome suggestions for improvement in our Standards, and especially encourage readers to notify us immediately of any apparent inaccuracies or ambiguities. Please address your comme

11、nts to the Chief Executive of either Standards Australia or Standards New Zealand at the address shown on the back cover. This Standard was issued in draft form for comment as DR 05316. The Standard is downloaded from Standard Sharing AS/NZS 3823.2:2005 Australian/New Zealand Standard Performance o

12、f electrical appliances Airconditioners and heat pumps Part 2: Energy labelling and minimum energy performance standard (MEPS) requirements COPYRIGHT Standards Australia/Standards New Zealand All rights are reserved. No part of this work may be reproduced or copied in any form or by any means, elect

13、ronic or mechanical, including photocopying, without the written permission of the publisher. Jointly published by Standards Australia, GPO Box 476, Sydney, NSW 2001 and Standards New Zealand, Private Bag 2439, Wellington 6020 ISBN 0 7337 7077 0 Originated as AS/NZS 3823.2:1998. Previous edition AS/

14、NZS 3823.2:2003. Fifth edition 2005. AS/NZS 3823.2:2005 2 PREFACE This Standard was prepared by the Joint Standards Australia/Standards New Zealand Committee EL-15, Quality and Performance of Household Electrical Appliances, to supersede AS/NZS 3823.2:2003 (including Amendment 1). The AS/NZS 3823 se

15、ries comprises five Parts, as follows: AS/NZS 3823 Performance of electrical appliancesAirconditioners and heat pumps 3823.1.1 Part 1.1: Test methodsNon-ducted airconditioners and heat pumpsTesting and rating for performance 3823.1.2 Part 1.2: Test methodsDucted airconditioners and air-to-air heat p

16、umps Testing and rating for performance 3823.1.3 Part 1.3 Water-source heat pumpsTesting and rating for performance: Water-to-air and brine-to-air heat pumps 3823.2 Part 2: Energy labelling and minimum energy performance standard (MEPS) requirements (this Standard) 3823.3 Part 3: Calculation of perf

17、ormance for minimum energy performance standard (MEPS) requirements The overall objective of the AS/NZS 3823 series of Standards is to promote high levels of performance and energy efficiency in airconditioners and heat pumps. The Parts of the AS/NZS 3823 series are summarized as follows: (a) Part 1

18、.1 includes performance test procedures for rating non-ducted airconditioners and heat pumps, to be used in conjunction with Part 2. (b) Part 1.2 includes performance test procedures for rating ducted airconditioners and heat pumps, to be used in conjunction with Part 2. (c) Part 1.3 includes perfor

19、mance test procedures for rating water-to-air heat pumps and airconditioners with water cooled condensers, to be used in conjunction with Part 2. (d) Part 2 specifies minimum energy performance standard (MEPS) requirements and includes algorithms for the calculation of the energy efficiency star rat

20、ing, performance requirements, details of energy labels and requirements for valid applications for registration. (e) Part 3 specifies procedures for calculating the performance (simulation) of airconditioners of the vapour compression type up to a rated cooling capacity of 65 kW, for minimum energy

21、 performance standard (MEPS) requirements, in lieu of physical tests. The main changes in this Standard are the introduction of a revised timetable and levels for minimum energy performance standard requirements for single-phase units in the years up to 2008 and the notification of a revised energy

22、labelling algorithm for introduction from 2008. This edition also includes references to Part 1.3 for water sourced heat pumps. The Standard is downloaded from Standard Sharing 3 AS/NZS 3823.2:2005 Similar to the previous revisions of this Standard it is possible to use either physical tests or sim

23、ulated performance tests (described in AS/NZS 3823.3) to demonstrate compliance with the minimum energy performance standard requirements for three-phase and some single- phase units (units which do not carry an energy label). Only physical tests can be used to demonstrate compliance with energy lab

24、elling. Suppliers of three-phase, single-phase ducted and single-phase commercial units may choose to fix energy labels to products; if so, then all of the usual requirements for energy labelling will apply (including the requirement for a physical test). The status of energy labelling and minimum e

25、nergy performance standard (MEPS) Australian regulatory programs and their date of implementation, for the various airconditioning equipment configurations, is provided in Appendix E. This Standard is published with the approval of the combined state and territory regulatory authorities and is struc

26、tured to be suitable for reference in legislation calling up minimum energy performance standards and also for reference in energy labelling regulatory legislation. Key regulatory dates in this Standard and other changes are as follows: (a) The change in scope of the mandatory energy labelling progr

27、am for household airconditioners and heat pumps from a 7.5 kW cooling requirement to a single-phase requirement was 1 October 2001. (b) Introduction of MEPS for three-phase airconditioners was 1 October 2001. (c) Introduction of MEPS for single-phase airconditioners was 1 October 2004. (d) Single-ph

28、ase ducted units, which are registered to any relevant MEPS level under this Standard, may carry an energy label on a voluntary basis. (e) Revised three-phase MEPS levels will be introduced on 1 October 2007 (no change from 2003 edition of this Standard). (f) Single-phase MEPS levels for some catego

29、ries of products originally proposed for 1 October 2007 have been advanced to 1 April 2006 and an additional MEPS level for 1 October 2008 has also been included. (g) Class A efficiency levels will be valid for the next iteration of MEPS after 2008. (h) A minor change to the wording on the energy la

30、bel for variable output compressors. Section 4 of this Standard sets out the transition provisions for energy labelling and MEPS under this Standard. New Zealand Energy Efficiency (Energy Using Products) Regulations 2002 had a commencement date of 1 April 2002 for energy performance labelling of sin

31、gle-phase airconditioners and 1 July 2002 for MEPS for three-phase airconditioners which currently includes only the requirements of the 2003 edition of this Standard. The revised MEPS levels and introductory dates for single phase units in New Zealand will be addressed by an amendment to this Stand

32、ard, which is expected in early 2006. The terms normative and informative have been used in this Standard to define the application of the appendix to which they apply. A normative appendix is an integral part of a Standard, whereas an informative appendix is only for information and guidance. State

33、ments expressed in mandatory terms in notes to figures, are deemed to be requirements of this Standard. AS/NZS 3823.2:2005 4 CONTENTS Page SECTION 1 SCOPE AND GENERAL 1.1 SCOPE 6 1.2 EXCLUSIONS 6 1.3 APPLICATION.7 1.4 OBJECTIVE7 1.5 REFERENCED DOCUMENTS 7 1.6 DEFINITIONS 8 1.7 MEASURED QUANTITIES. 1

34、0 1.8 ROUNDING 10 1.9 CLAIMS OF CAPACITY AND ENERGY CONSUMPTION 10 SECTION 2 CALCULATIONS FOR THE ENERGY LABEL 2.1 SCOPE 11 2.2 GENERAL 11 2.3 NUMBER OF TESTS AND PROCESSING OF DATA 11 2.4 COMPARATIVE ENERGY CONSUMPTION (CEC) 12 2.5 STAR RATING INDEX (SRI) 12 2.6 STAR RATING. 13 2.7 EXAMPLE OF ENERG

35、Y EFFICIENCY CALCULATIONS . 13 2.8 ENERGY LABEL VALIDITY (CHECK TESTING) 13 2.9 MAXIMUM COOLING TEST 14 2.10 TOP ENERGY SAVER AWARD. 14 SECTION 3 PERFORMANCE CRITERIA 3.1 GENERAL 15 3.2 MINIMUM ENERGY PERFORMANCE STANDARD 15 3.3 CLASS A EFFICIENCY AIRCONDITIONERS. 18 3.4 TEST CONDITIONS FOR DETERMIN

36、ING MINIMUM ENERGY PERFORMANCE STANDARDS AND HIGH EFFICIENCY CLAIMS. 19 3.5 NUMBER OF TESTS AND PROCESSING OF DATA 19 3.6 MINIMUM ENERGY PERFORMANCE STANDARD REQUIREMENTS COMPLIANCE . 20 3.7 MEPS VALIDITY (CHECK TESTING). 20 3.8 VARIABLE OUTPUT COMPRESSORS 21 3.9 COEFFICIENT OF PERFORMANCE AT LOW TE

37、MPERATURE. 21 3.10 STANDBY POWER AND CRANK CASE HEATERS 21 3.11 LOAD CONTROL CAPABILITY 21 3.12 POWER FACTOR. 21 SECTION 4 APPLICATION AND TEST RESULT FORMATS 4.1 APPLICATION FOR REGISTRATION . 22 4.2 HOLDING OF RECORDS 23 4.3 DATE OF MANUFACTURE INFORMATION 24 The Standard is downloaded from Stand

38、ard Sharing 5 AS/NZS 3823.2:2005 Page SECTION 5 PRINTING AND PLACEMENT OF ENERGY LABELS 5.1 PLACEMENT. 25 5.2 MATERIAL AND SHAPE 25 5.3 COLOURS 25 5.4 LABEL REQUIREMENTS. 26 5.5 SAMPLE LABELS 26 APPENDICES A EXAMPLES OF ENERGY EFFICIENCY CALCULATIONS . 31 B FORMAT OF APPLICATION FOR REGISTRATION OF

39、AN AIRCONDITIONER FOR ENERGY LABELLING AND MEPS. 35 C FORMAT OF SUMMARY TEST RESULTS FOR AN ENERGY LABELLING AND/OR MEPS APPLICATION WHERE FULL TEST REPORTS ARE NOT PROVIDED. 53 D ENERGY LABEL DIMENSIONS 57 E ENERGY LABELLING AND MEPS REQUIREMENTS FOR VARIOUS AIRCONDITIONING EQUIPMENT CONFIGURATIONS

40、. 62 F NEW ENERGY LABELLING ALGORITHMS 66 AS/NZS 3823.2:2005 6 COPYRIGHT STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND Australian/New Zealand Standard Performance of electrical appliancesAirconditioners and heat pumps Part 2: Energy labelling and minimum energy performance standard (MEPS) requirements S

41、 E C T I O N 1 S C O P E A N D G E N E R A L 1.1 SCOPE This Standard specifies the energy labelling requirements for single-phase non-ducted airconditioners of the vapour compression type for household use and the minimum energy performance standard (MEPS) requirements for single-phase and three-pha

42、se airconditioners of the vapour compression type up to a rated cooling capacity of 65 kW and that fall within the scope of AS/NZS 3823.1.1 or AS/NZS 3823.1.2 or AS/NZS 3823.1.3. Particular regulatory requirements for different categories of airconditioning equipment and validity dates are summarize

43、d in Appendix E of this Standard. The revised MEPS levels and introductory dates for single phase units beyond 2004 in New Zealand will be addressed by an amendment to this Standard. This Standard does not specify electrical safety requirements. This Standard specifies the following values for cooli

44、ng and heating, as applicable: (a) Rated power (input). (b) Rated capacity (output). (c) Energy efficiency ratio (EER) for cooling. (d) Coefficient of performance (COP) for heating. (e) Comparative energy consumption (CEC). (f) Star Rating Index (SRI). (g) Star rating. (h) Some of the requirements f

45、or energy label validity. (i) The performance criteria for energy labelling validity. (j) Test report format. (k) Printing requirements for airconditioner appliance energy labels. (l) Minimum energy performance standard requirements. 1.2 EXCLUSIONS The following equipment is excluded from the scope

46、of this Standard: (a) Close controlled airconditioners, pending the development of MEPS levels for these products. (b) Multi-split systems (i.e., those having more than one indoor unit with an independent control for each indoor unit) pending the development of a suitable test method. The Standard i

47、s downloaded from Standard Sharing 7 AS/NZS 3823.2:2005 COPYRIGHT (c) Evaporative coolers or any other cooling systems that are not of the vapour compression type. (d) Ground-water-sourced or ground-loop-sourced heat pumps within the scope of Part 1.3. NOTE: Water loop heat pumps as defined in Part

48、 1.3 are included within the scope of this Standard. (e) Unbalanced airconditioners and spot coolers (these include many portable types). (f) Commercial chillers which are used in commercial buildings to provide chilled-water for space cooling equipment. (g) Models that have been granted exemption b

49、y the relevant Australian/New Zealand regulatory authority due to their specific design for applications such as process heating or cooling or for heating or cooling of spaces to conditions that are not intended for human comfort. 1.3 APPLICATION This Standard shall be read in conjunction with AS/NZS 3823.1.1, AS/NZS 3823.1.2, AS/NZS 3823.1.3 and AS/NZS 3823.3, as applicable. Products that have water-cooled condensers as well as water-source heat pumps fall within the scope of this Standard and